Loading...
HomeMy WebLinkAboutS-1343 Staff AnalysisItem No. 6 Nabholtz Port Industrial Park Preliminary Plat S-1343 Planning Staff Comments: 1. Provide notification of Public Hearing to abutting Property Owners. 2. Provide Source of Title. 3. Provide Vicinity Map to scale. 4. Provide Phasing Plan. 5. Indicate boundary lines in a heavy solid line around the perimeter of the property. 6. Provide means of wastewater disposal. — See Wastewater comment below. 7. Plat a 30-foot Building Line on all property lines not abutting a street right-o€way. 8. Will the gravel road remain or will the ingress/egress along the south property line become the point of access to natural facilities. Variance/Waivers: None requested. Public Works: 1. Fletcher Road is classified as an industrial road. Dedicate right-o€way from centerline a minimum of 34 feet. Dedicate 50' on Zueber Road as shown. Demonstrate adequacy of right-of-ways to handle ditch flows. 2. Construct one-half street improvements on Zueber and Fletcher Roads to industrial street standards of the Master Street Plan. Construct internal street to full width standards. 3. Plans of all work in right-of-way shall be submitted for approval prior to start of work. 4. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering at 501-340-4854 (Derrick Bergfield) for more information. Utilities and Fire Department/County Planning: Wastewater: Outside service boundary. No comment. ENTERGY: A 15-foot easement is necessary or aerial 8KV electrical circuit. A 50-foot setback should allow any tree clearing, if necessary. Note: If 30, 13KV circuit is requested or required by a customer then, a 30-foot right-of-way is necessary. Contact Entergy at 569-5448 for additional details. ARKLA: No comment received. Southwestern Bell: No comment received. Water: Execution of a Pre -Annexation Agreement, approval of the City of Little Rock, and a water main extension are required before water service is available to this property. An acreagecharge of $150 per acre currently applies in addition to normal charges in this area. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department for additional details at 918-3752. County Planning: 1. Source of Title. 2. Boundary line need to be thickened and solid. 3. Please provide development plan. 4. Describe any existing or proposed covenants. 5. Describe and show on the Plat drainage and Flood Control Plans. 6. Provide on Plat Certificate of Approval related to Pulaski County Planning. 7. Street Plan Profile —Need 50-foot radius and Curb and Gutter. 8. Provide Bill of Assurance. 9. Provide Letter of Wastewater Approval. 10. Conformation on Access Roads Meeting Right -of -Way Requirement as per the Master Highway Plan. 11. FEMA Panel Number and Floodway/Plain Designated. 12. Certification or approval by Fire District Servicing Development (Office of Emergency Service can confirm District Servicing Area and Contact Person — 340-6819). 13. Explain Erosion Control Methods. 14. Provide a copy of State Land Clearing Permit. 15. Show Basis for North. 16. Provide Road Plan. 17. Provide Drainage plan and calculations. 18. South Port Drive - a) Change 30-foot radius to 50-foot radius. b) Show right-of-way to be 70-foot — 44-feet asphalt with curb and gutter (class V C-Industrial). c) Show soil reports and road designs based upon those reports. 19. Fletcher Road - a) This Road is not designed for Industrial loading. b) It is a chip and seal surface. Owner will be required to bring Fletcher Road up to standards. c) Road right-of-way is currently 50-feet — Industrial developments according to Master Street Plan requires a 70-foot right-of-way for a minor street and 100-feet minimum for a major street. d) Show existing right-of-way from centerline to edge of right-of-way and show the proposed right -of way dedication. 20. Building setbacks should be 70-feet on major roads. No building line shall be less than 30-feet from all other property lines. — Show all building setback lines on plat. 21. Provide estimated traffic volumes onto Zueber Road and Fletcher Road. A traffic signal light at Zueber and Southport may be required in the future to accommodate additional traffic volume. If so, owner will be responsible for partial financing of the cost of the project. 22. Please recheck legal for proper closure. Staff recommendation: Staff cannot recommend approval of this plat at this time. Because of the many concerns expressed in this review, Staff recommends that the project representatives/owner schedule an appointment with County Staff and discuss this project. A copy of the County Industrial Development Requirements and Road Standards for Industrial Development may be obtained by calling 340-8260. CATA: Site is not located on a dedicated bus route and has not effect on bus radius, turnout and route. Planning Division: No comment. Landscape- No comment. Submit 4 copies of the revised site plan (to include additional information as noted above) to staff no later than Wednesday June 5, 2002. June 20, 2002 ITEM NO.: 6 NAME: Nabholtz Port Industrial Park Preliminary Plat LOCATION: Southwest corner of Zuber Road and Fletcher Road DEVELOPER: ENGINEER: FILE NO.: S-1343 Nabholz Properties, Inc. The Mehlburger Firm P.O. Box 127 201 South Izard Conway, AR 72033 Little Rock, AR 72201 AREA: 73.671 Acres NUMBER OF LOTS: 15 FT. NEW STREET: 2475 CURRENT ZONING: Not zoned; Within the ETJ; Subdivision Authority Only. PLANNING DISTRICT: 26 CENSUS TRACT: 40.07 VARIANCESANAIVERS REQUESTED: None requested. A. PROPOSAL/REQUEST: The applicant is proposing the subdivision of this 73.671 acre site into 15 industrial lots. The average lot size proposed is 4.661 acres with the minimum lot size being 3.046 acres and the largest lot being 6.360 acres. The applicant proposes the extension of an industrial street from Zuber Road to Fletcher Road with 36-foot of paving, open ditches on each side and 68-foot of dedicated right- of-way (South Port Drive). The applicant is proposing to construct one-half street improvements to Zuber Road and Fletcher Road as required by the Master Street Plan along with the dedication of right-of-way; 34-feet from centerline for Fletcher Road and 50-feet from centerline for Zuber Road. June 20, 2002 SUBDIVISION ITEM NO.: 6 FILE NO.: S-1343 B. EXISTING CONDITIONS: The site is a vacant relatively flat open field, which has been used for agriculture purposes in the past although not currently planted with row crops. The site contains a "stick -built" single-family home along with a manufactured home located near Zuber Road. The site also contains a large electrical transmission power line and an underground gas line both located near the eastern boundary running northeasterly/southwesterly. The area is predominately agricultural uses with the exception of scattered farm homes and shop buildings. To the northeast is the Little Rock Industrial Port; with industrial uses being within Y2 mile of the proposed site. Zuber Road and Fletcher Road are unimproved chip -seal roadways with Fletcher Road being a narrow roadway dead -ending into a single- family residence. Zuber Road extends from Fourche Dam Pike to Sloane Street near the entrance to College Station. C. NEIGHBORHOOD COMMENTS: The College Station and the Granite Mountain Neighborhood Associations were notified of the Public Hearing as well as all property owners abutting the site. As of this writing staff has not received any comment from the neighborhood. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Fletcher Road is classified as an industrial road. Dedicate right-of-way from the centerline a minimum of 34 feet. Dedicate 50 foot on Zuber Road as shown. Demonstrate adequacy of right-of-ways to handle ditch flows. 2. Construct one-half street improvements on Zuber and Fletcher Roads to industrial street standards of the Master Street Plan. Construct internal street to full width standards. 3. Plans of all work in right-of-way shall be submitted for approval prior to start of work. 4. Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any work in the right-of-way. Contact Traffic Engineering at 501-340-4854 (Derrick Bergfield) for more information. E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Outside service boundary. No comment. ENTERGY: A 15-foot easement is necessary or aerial 8KV electrical circuit. A 50-foot setback should allow any tree clearing, if necessary. Note: If 30, 13KV circuit is requested or required by a customer then, a 30-foot right-of- 2 June 20, 2002 SUBDIVISION ITEM FILE NO.: S-1343 way is necessary. Contact Entergy at 569-5448 for additional details. ARKLA: Approved as submitted. Southwestern Bell: No comment received. Water:Execution of a Pre -Annexation Agreement, approval of the City of Little Rock, and a water main extension are required before water service is available to this property. An acreage charge of $150 per acre currently applies in addition to normal charges in this area. Contact Central Arkansas Water at 992-2438 for additional details. Fire Department: Place fire hydrants per code. Contact the Little Rock Fire Department for additional details at 918-3752. County Planning; 1. Source of title. 2. Boundary line needs to be thickened and solid. 3. Please provide development plan. 4. Describe any existing or proposed covenants. 5. Describe and show on the plat drainage and flood control plans. 6. Provide on Plat Certificate of Approval related to Pulaski County Planning. 7. Street plan profile — Need 50-foot radius and curb and gutter. 8. Provide Bill of Assurance. 9. Provide letter of wastewater approval. 10. Conformation on access roads meeting right-of-way requirement as per the Master Highway Plan. 11. FEMA Panel Number and Floodway/Plain Designated. 12. Certification or approval by fire district servicing development (Office of Emergency Service can confirm district servicing area and contact person — 340-6819). 13. Explain erosion control methods. 14. Provide a copy of state land clearing permit. 15. Show basis for north. 16. Provide road plan. 17. Provide drainage plan and calculations. 18. South Port Drive - a) Change 30-foot radius to 50-foot radius. b) Show right-of-way to be 70-foot — 44-feet asphalt with curb and gutter (Class V C-Industrial). c) Show soil reports and road designs based upon those reports. 19. Fletcher Road - a) This road is not designed for industrial loading. b) It is a chip and seal surface. Owner will be required to bring Fletcher 3 June 20, 2002 SUBDIVISION ITEM NO.: 6 FILE NO.: S-1343 Road up to standards. c) Road right-of-way is currently 50-feet — Industrial developments according to Master Street Plan requires a 70-foot right-of-way for a minor street and 100-feet minimum for a major street. d) Show existing right-of-way from centerline to edge of right-of-way and show the proposed right-of-way dedication. 20. Building setbacks should be 70-feet on major roads. No building line shall be less than 30-feet from all other property lines. — Show all building setback lines on plat. 21. Provide estimated traffic volumes onto Zuber Road and Fletcher Road. A traffic signal light at Zuber and Southport may be required in the future to accommodate additional traffic volume. If so, owner will be, responsible for partial financing of the cost of the project. 22. Please recheck legal for proper closure. County Staff Recommendation: Staff cannot recommend approval of this plat at this time. Because of the many concerns expressed in this review, Staff recommends, that the project representatives/owner schedule an appointment with County Staff and discuss this project. A copy of the County Industrial Development Requirements and Road Standards for Industrial Development may be obtained by calling 340- 8260. CATA:Site is not located on a dedicated bus route and has no effect on bus radius, turnout and route. F. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. G. SUBDIVISION COMMITTEE COMMENT: May 30, 2002 The applicant was not present. Staff introduced the item indicating the proposed subdivision was located in the City's Extraterritorial Planning Jurisdiction for subdivision but the area did not have zoning. Staff stated the proposed industrial subdivision preliminary plat complied with the requirements for industrial subdivisions outside the City limits but within the City's Planning Jurisdiction. Staff stated there were some discrepancies between the County requirements and the City requirements and Staff, along with the applicant, would meet to 4 June 20, 2002 SUBDIVISION ITEM NO.: 6 FILE NO.: S-1343 discuss the discrepancies. There was no further discussion. The Committee then forwarded the item to the full Commission for final action. H. ANALYSIS: The applicant submitted a revised plat to staff addressing the issues raised. The applicant has platted a 70-foot platted building line from the centerline of the street as required by the City's Subdivision Ordinance. The applicant has agreed to construct Y2 street improvements to Fletcher Road and Zuber Road in accordance with the City's Master Street Plan requirement. The applicant has also platted a 30-foot platted building line along all property lines not adjacent to a street as required by the Subdivision Ordinance. The applicant has indicated the project will be developed in one Phase including all streets and utilities. Although County comments are extensive with regard to this application City Staff has had conversations with County Staff and many of the issues raised by the County are issues which were also raised by City Staff and requested to be included on the revised preliminary plat (most of which have been addressed). For the most part the issues have been resolved during the preliminary platting process or will be resolved during the final platting process. The applicant has indicated they will seek annexation to the City of Little Rock to receive sewer service to the site. This annexation request should be forth coming in the next 60 to 90 days. Should the applicant not receive city sewer service the applicant will be required to revise the preliminary plat indicating the means of wastewater disposal in accordance with all County and State Health Department requirements. The applicant will also be required to address the concerns of the County Staff with regard to the preliminary plat approval process noted in Section E should the proposed annexation not become reality. Staff is supportive of the proposed preliminary plat as filed. The proposed plat meets the minimum requirements as set forth in the Subdivision Ordinance for industrial subdivisions outside the City limits but within the City's Extraterritorial Planning Jurisdiction. STAFF RECOMMENDATION: Staff recommends approval of the proposed preliminary plat subject to compliance with the conditions outlined in paragraphs D, E, F and H of this report. 5