HomeMy WebLinkAboutS-1334 Staff AnalysisBARTLETT
Architects * Planners * Designers 6427 Miller Road
Alexander, AR 72002
501-847-6968
Jan. 30, 2002
To: the City of Little.Rock
Department of Planning and Development
723 West Markham
Little Rock, AR 72201
Attention: Donna James 501-371-6821
This letter is in response to the comments for the Greater Christ Temple
Pentecostal Church at 1200 Lewis Street (13' Street, Lewis Street & 12'
Street).
Planning Staff Comments
1.The seating capacity is 500 to 600.
2. The North and South elevations are attached.
3. The canopy material match the building (steel, brick, eifs & metal roof)
4, 5, 6. Added to drawing.
7. Maximum allowed by the city ordnance.
8, 9. Added to drawing.
10. Basketball court, fellowship area, classrooms, kitchen and platform area.
11. Hours of operation will be 9 am to 4 pm and occasionally 4 pm to 10 pm.
12, 13, 14, 15. Added to drawing.
16. No fence will be added to the property.
17. Property owners and proof of mailing attached.
Public Works
1, 2, 3, 4. Added to drawing.
5. Will be submitted before work is started.
6, 7. Grading plan and storm water are included in drawing set
8. The Street lights and on site lighting will be coordinated with the City Traffic Engineer
9. Added to drawing.
10. Access easement to 13 `h street was added, see drawing.
11. Access easement to 13`h street.
Fred Harris, Assistant Church Business Administrator; 501-563-1615
Daniel Bartlett, Architect; 501-847-6968
R ;7IN/ �
F u !� ��suZ
February 14, 2002
ITEM NO.: 8
FILE NO.: S-1334
NAME: Greater Christ Temple Pentecostal Church Subdivision
Site Plan Review
LOCATION: 1200 Lewis Street
nEVELOPER:
ENGINEER:
Greater Christ Temple Bartlett Architecture
Pentecostal Church 6427 Miller Road
1200 Lewis Street Alexander, AR 72002
Little Rock, AR 72204
AREA: 2.9 Acres NUMBER OF LOTS:-1 FT. NEW STREET: 0
CURRENT ZONING: C-3
PROPOSED ZONING: C-3
CURRENT ALLOWED USES: Church
PROPOSED USE: Church with Family Life Center
VARIANCES/WAIVERS REQUESTED: Variance for the side yard and
rear yard setbacks for the garage building.
A. PROPOSAL/REQUEST:
The applicant proposes to add a Family Life Center and
replace an existing garage building located on the church
property at 1200 Lewis Street. The proposed building will
include a basketball court, fellowship area, classrooms,
kitchen and platform area. The proposal includes the
addition of 50 off-street parking spaces and low ambient
February 14, 2002
SUBDIVISION
ITEM NO.: 8 (Cont.)
FILE NO.: S-1334
lighting directed away from residential areas. The new
Family Life Center will be approximately 14,000 square
feet while the new garage will be similar in size to the
existing garage located adjacent to West 12th Street (40 x
48) .
B. EXISTING CONDITIONS:
The property is currently zoned C-3 as is the area to the
west of the site. The site contains an existing church
facility and a garage adjacent to West 12th Street. Other
properties in the area along West 12th Street contain a mix
of residential and non-residential uses. To the northeast
of the site, there is a Harvest Foods, Auto Zone and
beauty shop. Areas to the east, south and southwest are
zoned R-3 and contain single-family residences. Abigail
Street, which is barricaded between West 12th Street and
West 13th Street and has been abandoned, runs through the
western portion of the property. This area will be
included in the proposed parking area.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received no comment from the
neighborhood. All property owners within 200 feet of the
site, all residents within 300 feet of the site who could
be identified and the Forest Hill, Hope, Stephens Area
Faith and the Pine to Woodrow Neighborhood Associations
were notified of the public hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. W. 12th Street is classified on the Master Street Plan
as a minor arterial. A dedication of right-of-way 35
feet from centerline will be required.
2. A 20 feet radial dedication of right-of-way is required
at all corners.
3. Property frontage needs to have the sidewalks and ramps
brought up to the current ADA standards.
4. Repair or replace any curb and gutter or sidewalk that
is damaged in the public right-of-way prior to
occupancy.
N
February 14, 2002
SUBDIVISION
ITEM NO.: 8 (Cont.
FILE NO.: 5-1334
5. Plans of all work in right-of-way shall be submitted
for approval prior to start of work.
6. Grading permit will be required on this development.
7. Storm water detention ordinance applies to this
property.
8. Prepare a letter of pending development addressing
streetlights as required by Section 31-403 of the
Little Rock Code. All requests should be forwarded to
Traffic Engineering.
9. Remove all existing radiuses on 12th and 13t' Streets
and restore curb and gutter. Abandon Abigail right-of-
way and easement rights of utilities as required.
10. Provide right-of-way and turn around for alley in block
2. Abandon alley within property boundaries.
11. Turn around must accommodate Waste Management trucks.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer is available on the site located under
existing building. Contact Little Rock Wastewater
Utility at 376-2903 for details.
Entergy: Approved as submitted. Alley right-of-way has
not been abandoned. Contact Entergy at 354-5165 for
details.
ARKLA: No comment received.
Southwestern Bell: Approved as submitted.
Water: Water facilities relocation will be done by the
developer at its expense to Central Arkansas Water
specifications. A contract with Central Arkansas Water
and an easement for relocated facilities will be
required. Contact Marie Dugan at 992-2438 for details.
Fire Department: Approved as submitted.
County Planning: No comment received.
CATA: Site is on Bus Route #3 and has no effect on bus
radius, turnout and route.
3
February 14, 2002
SUBDIVISION
ITEM NO.: 8 (Cont.)
F. ISSUES/TECHNICAL/DESIGN:
Plannina Division: No comment.
City Recognized Neighborhood Action Plan:
FILE NO.: S-1334
The proposed project lies in an area covered by the Oak
Forest Neighborhood Action Plan. Under the Economic
Development Goal the plan states a desire create a healthy
economic climate that encourages investment, reinvestment
and diversity of employment opportunities. Although the
Action Statements primarily deal with commercial type
establishments the construction of the new Family Life
Center by the Church could be seen as an act to promote
investment into the area.
Landscape Issues:
Six percent of the interior of the new vehicular use area
(688 square feet) must be landscaped with interior
islands. The plan submitted falls 328 square feet short
of fulfilling this requirement. These calculations are
based with the designated "mature area" reduction in mind.
A landscaping upgrade toward compliance with the landscape
ordinance equal to the building expansion proposed will be
required of existing vehicular use area.
Building Codes: No comment received.
G. SUBDIVISION COMMITTEE COMMENT: (January 24, 2002)
The applicant was present representing the application.
Staff presented the item and noted that additional
information was needed on the proposed building materials,
number of existing parking spaces and existing and
proposed building setbacks. Staff noted comments from the
utilities and Central Arkansas Water. Public Works
Comments were also presented.
The issue of the utility easement running from when
Abigail Street was abandoned was discussed at length.
Staff stated it would be necessary to abandon the existing
4
February 14, 2002
SUBDIVISION
ITEM NO.: 8 (Cont.)
FILE NO.: S-1334
utility easement and establish a new utility easement.
Staff stated the process would take Board of Directors'
action and the time frame would be approximately 30 days.
Staff stated the applicant would be required to file a
separate application for the process to begin.
The applicant stated there were no additional questions.
He stated the site plan would be revised and the
additional information submitted to staff. The Committee
then determined there were no other outstanding issues
associated with the proposed site plan review. The
Committee then forwarded the application to the full
Commission for final action.
H. ANALYSIS:
The applicant submitted to staff on January 30, 2002 a
revised site plan addressing the issues as raised by staff
and the Subdivision Committee. The applicant has shown
the total number of parking spaces to be 103 (54 existing
parking spaces and 49 parking spaces proposed), some of
which will be lost to landscaping requirements. Parking
requirements for churches constructed prior to November 1,
1988 require one space per five seats. The applicant
estimates the seating capacity of the sanctuary to be 500
to 600 persons, including the choir seating area. Since
the applicant is not increasing the sanctuary seating,
they are not required to provide any additional parking
spaces. With the proposal, they are bringing the total
number of required spaces (100 to 120 required parking
spaces) more in line with the Code.
The proposed setback for the new garage is 10-feet from
the side yard and 10-feet from the rear yard. In C-3
zoning the minimum side yard setback is 15-feet and the
rear yard setback is 25-feet. The proposed setbacks will
require a variance. Staff is supportive of this variance
request. All other setbacks meet with minimum Code
requirement.
The applicant is not requesting any additional ground
mounted sign area but will place wall signage on the new
building. The applicant has requested the maximum wall
signage allowable under the Ordinance, 10% of the fagade
February 14, 2002
SUBDIVISION
ITEM NO.: 8 (Cont.)
FILE NO.: 5-1334
area adjacent to the street. The applicant has requested
both street frontages (West 12t' and West 13t' Streets) have
a wall sign.
The applicant is proposing to relocate the utilities
located in Abigail Street (previously abandoned as a
street) and provide a service and access easement through
their property from the alley in Block 2. The dumpster
site has been located on the site plan, adjacent to West
13t' Street, with proper screening put in place.
Staff is supportive of the Subdivision Site Plan Review
for the Greater Christ Temple Pentecostal Church. Staff
feels the addition of a Family- Life Center to the church
property will have no adverse impact on the general area.
The hours of operation do not appear to be in conflict
with the neighborhood (9 am to- 4 pm daily activities with
occasional use to 10 pm for special events). Otherwise,
to staff 's knowledge, there are no outstanding issues
associated with the proposed application.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested site plan
review subject to compliance to the following conditions:
1. Compliance with the conditions as noted in paragraphs D,
E and F of this report.
2.The applicant must submit an application and be approved
for relocation of the utility easements located in the
former Abigail Street.
Staff is supportive of the requested variance for a reduced
side yard and rear yard setback.
PLANNING COMMISSION ACTION:
(FEBRUARY 14, 2002)
The applicant was present representing the application. Staff
presented the item with a recommendation of approval subject to
compliance with the conditions outlined in the "staff
recommendation" above.
February 14, 2002
SUBDIVISION
ITEM NO.: 8 (Cont.)
FILE NO.: 5-1334
There was no further discussion. The application was placed on
the consent agenda for approval as recommended by staff. The
vote passed by 10 ayes, 0 noes and 0 absent and 1 recuse.
7