HomeMy WebLinkAboutS-1280-P Staff AnalysisAugust 27, 2015
ITEM NO.: 2 FILE NO.: S-1280-P
NAME: LaMarche Garden Preliminary Plat
LOCATION: Located East of the Valley Falls Estates Subdivision and South of the
Gardens at Valley Falls Subdivision
DEVELOPER:
Bullwinkle, LLC
1501 North University Avenue
Little Rock, AR 72207
ENGINEER:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 16.1 acres NUMBER OF LOTS: 61 FT. NEW STREET: 2,500 LF
CURRENT ZONING: R-2, Single-family
PLANNING DISTRICT: 19 — Chenal
CENSUS TRACT: 42.12
VARIANCEM/AIVERS:
1. A variance from Section 36-245(d) (3) to allow a reduced rear yard setback.
2. A variance from Section 36-254(d) (2) to allow a reduced side yard setback.
3. A variance from Section 36-254(d) (1) to allow a reduced front yard setback.
4. A variance from the City's Land Alteration Ordinance to allow grading of the lots with
the development of the subdivision.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The proposed development contains 16.1-acres located on the west side of
LaMarche Drive and south of Taylor Loop Road. The project is adjacent to the
Gardens at Valley Falls Estates on the north and Valley Falls Estates on the west
and Chenal Valley to the south. The developer is proposing 61-lots that average
60-feet wide and 117-feet deep. A variance for 20-foot front and rear yard
August 27, 2015
SUBDIVISION
ITEM NO.: 2 (Cont.
FILE NO.: S-1280-P
setbacks along with 5-foot side yard setbacks is being requested. The setbacks
proposed are similar to those in the Gardens at Valley Falls and allow
construction of slightly larger homes to blend with the surrounding developments.
An emergency access is proposed to the west and will connect to Valley Creek
View within the Valley Falls Estates subdivision. This connection will provide
secondary access to the Valley Falls Estates subdivision to LaMarche Drive as
well as provide this proposed subdivision secondary access via Valley Falls
Estates. The access was indicated on the original plat for Valley Falls Estates
nearly 15-years ago. The access will be gated with a "knox-box" for emergency
personnel only.
The request includes a variance from the City's Land Alteration Ordinance to
allow advanced grading. This will allow the entire subdivision to be graded at
one time with all the infrastructure being completed as a single phase. The
developer is also proposing 15-foot tall slopes with 10-foot benches as opposed
to the typical 10-foot tall slopes. The total slope height will not exceed 30-feet.
This will allow additional areas to capture run-off on the south side of the project
where it will be piped to the proposed stormwater detention facility at the
northeastern corner of the development.
B. EXISTING CONDITIONS:
The site is a wooded site siting on the western side of the proposed LaMarche
Drive extension. A contact has been awarded for the construction of LaMarche
Drive and the roadway should be completed in early 2016. To the east of the site
are single-family homes located on 5 plus acre lots. West of the site are homes
constructed in the Valley Falls Estates Subdivision which has developed with
larger lots, for the most part one (1) acre and above, and to the north is a
single-family subdivision which has developed with attached and detached
single-family homes. The detached homes are located on lots which average
7,500 square feet.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area property owners.
All abutting property owners were notified of the public hearing. There is not an
active City of Little Rock recognized neighborhood association located in this
immediate area.
2
August 27, 2015
SUBDIVISION
ITEM NO.: 2 Cont. FILE NO.: S-1280-P
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS-
1. To comply with the Master Street Plan, LaMarche Garden Drive should be
constructed to a residential street standard with 50 foot right-of-way and
sidewalk on one (1) side from LaMarche Drive to the west intersection of
LaMarche Garden Loop.
2. Are the streets proposed to be public or private?
3. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Other
than residential subdivisions, site grading and drainage plans must be
submitted and approved prior to the start of construction. Is the subdivision
proposed to be phased? If phasing is desired, is a variance requested to
advance grade future phases of construction with construction of Phase 1?
5. Stormwater detention ordinance applies to this property.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
7. Streetlights are required by Section 31-403 of the Little Rock code. Provide
plans for approval to Traffic Engineering. Streetlights must be installed prior
to platting/certificate of occupancy. Contact Traffic Engineering
501.379.1813, Greg Simmons _qsimmons(d),fltt1erock.2rg for more
information.
8. An emergency access easement should be provided to the public right-of-
way. Using turn movement templates show the proposed emergency
access easement can be maneuvered by a firetruck (B-40).
9. The street name LaMarche Garden Drive should be changed to "court" or
"cove" do to possible confusion with LaMarche Drive.
10. Provide a letter prepared by a registered engineer certifying the sight
distance at the intersection(s) comply with 2004 AASHTO Green Book
standards.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements if new sewer
service is required for this project. Contact Little Rock Wastewater Utility for
additional information.
3
August 27, 2015
SUBDIVISION
ITEM NO.: 2 (Cont.) FILE NO.: S-1280-P
Entergy: Entergy does not object to this proposal. Underground facilities are in
the vicinity to the north and to the west of this development. Contact Entergy in
advance regarding future service requirements to the development, line
extensions, and future facilities locations as this project proceeds.
CenterPoint Energu: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional
review. Contact Central Arkansas Water regarding procedures for installation
of water facilities and/or fire service. Approval of plans by the Arkansas
Department of Health Engineering Division and the Little Rock Fire
Department is required.
3. A Capital Investment Charge based on the size of meter connection(s) will
apply to this project in addition to normal charges. This fee will apply to all
connections including metered connections off the private fire system.
4. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
5. Contact Central Arkansas Water regarding the size and location of water
meter.
6. Due to the nature of this facility, installation of an approved reduced pressure
zone backflow preventer assembly (RPZA) is required on the domestic water
service. This assembly must be installed prior to the first point of use.
Central Arkansas Water requires that upon installation of the RPZA,
successful tests of the assembly must be completed by a Certified Assembly
Tester licensed by the State of Arkansas and approved by Central Arkansas
Water. The test results must be sent to Central Arkansas Water's Cross
Connection Section within ten days of installation and annually thereafter.
Contact the Cross Connection Section at 501.377.1226 if you would like to
discuss backflow prevention requirements for this project.
7. The facilities on -site will be private. When meters are planned off private
lines, private facilities shall be installed to Central Arkansas Water's materials
and construction specifications and installation will be inspected by an
engineer, licensed to practice in the State of Arkansas. Execution of a
Customer Owned Line Agreement is required.
G1
August 27, 2015
SUBDIVISION
ITEM NO.: 2 (Cont.
FILE NO.: S-1280-P
8. Fire sprinkler systems which do not contain additives such as antifreeze shall
be isolated with a double detector check valve assembly. If additives area
used, a reduced pressure zone back flow preventer shall be required.
9. This development will have minor impact on the existing water distribution
system. Proposed water facilities will be sized to provide adequate pressure
and fire protection.
Fire Department: Maintain Access:
Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is located on a
fire apparatus access road, the minimum road width shall be 26 feet, exclusive of
shoulders.
Dead Ends. Maintain fire apparatus access roads at dead end locations as
per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet
shall be provided with width and turnaround provisions in accordance with Table
D103.4. Requirements for Dead-end fire apparatus access roads.
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two -Family dwelling residential developments.
Developments of one- or two-family dwellings where the number of dwelling units
exceeds 30 shall be provided with two separate and approved fire apparatus
access roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road
shall not be increased unless fire apparatus access roads will connect
with future development, as determined by the fire code official.
Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012
Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with
Central Arkansas Water (Jason Lowder 501.377.1245) and the Little Rock Fire
5
August 27, 2015
SUBDIVISION
ITEM NO.: 2 Cont. FILE NO.: S-1280-P
Marshal's Office (Captain Tony Rhodes 501.918.3757). Number and Distribution
of Fire Hydrants as per Table C105.1.
F.
Parks and Recreation: No comment received.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
ISSUES/TECHNICAL/DESIGN:
Buildin Code: No comment.
Planning Division: No comment.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (August 5, 2015)
Mr. Joe White of White-Daters and Associates was present. Staff presented the
item stating there were few outstanding technical issues associated with the
request in need of addressing. Staff stated the proposed preliminary plat did
include variances from the typical building setback standards established in the
R-2, Single-family Zoning District. Staff stated the variances were similar to
variance requests with other single-family developments in the area. Staff stated
the request included a secondary access to Valley Falls Estates. Staff stated the
secondary access was a condition of approval of the Valley Falls Estates
subdivision.
Public Works comments were addressed. Staff stated LaMarche Garden Drive
should be constructed to a residential street standard with a 50-foot right of way
and sidewalk on one (1) side from LaMache Drive to the west intersection of
LaMarche Garden Loop. Staff stated streetlights were required with the final
platting of the lots. Staff stated the City's Stormwater Detention Ordinance would
apply to the development of the subdivision. Staff questioned if the lots would be
developed in a single phase and if the applicant was requesting to advance
grade the site with the installation of the basic infrastructure.
Staff noted the comments from the various other agencies. There were no more
issues for discussion. The Committee then forwarded the item to the full
Commission for final action.
[1
August 27, 2015
SUBDIVISION
ITEM NO.: 2 (Cont.
H. ANALYSIS:
FILE NO.: S-1280-P
The applicant submitted a revised preliminary plat drawing to staff addressing
most of the technical issues associated with the request raised at the August 5,
2015, subdivision committee meeting. The revised plan indicates the corner lots
with a tract to be owned by the property owners association. The plat indicates
the streets with a 45-foot right of way and 27-feet of pavement. The plat
indicates the lots will be developed in a single phase but the applicant is
requesting to grade the future lots with the installation of the streets, water and
sewer.
Staff recommends LaMarche Garden Drive to be constructed to a residential
standard from LaMarche Drive to the east LaMarche Garden Loop intersection
and then construct LaMarche Garden Drive to a minor residential standard west
of the LaMarche Garden Loop intersection. A standard residential street is to
contain a 50-foot right of way, with 26-feet of pavement, back of curb to back of
curb and sidewalk on one (1) side. A minor residential street standard allows for
construction of 24-feet of pavement within a 45-foot right of way. No sidewalk is
required for a minor residential street. The applicant has agreed to revise the
preliminary plat to reflect the street standard as recommended by staff.
The proposed development contains 16.1-acres and is proposed for
development with 61 single-family lots. The lots are proposed with an average
width of 60-feet and an average depth of 117-feet for an average lot area of
7,020 square feet. The development is proposed 3.8-units per acre.
The proposed plan includes a variance to allow 20-foot front and rear yard
setbacks along with 5-foot side yard setbacks. The zoning ordinance (Section
36-245) establishes setbacks for R-2, Single-family zoned lots. The zoning
ordinance typically requires the placement of a 25-foot front and rear yard
setback. Side yard setbacks are typically ten (10) percent of the lot width, not to
exceed eight (8) feet. Staff is supportive of the setbacks as proposed. The
setbacks are similar to the setbacks approved for the Gardens at Valley Falls
located north of this site.
The request includes a variance from the City's Land Alteration Ordinance to
allow advanced grading. This will allow the entire subdivision to be graded at
one time with all the infrastructure being completed as a single phase. The
applicant is proposing two (2) 15-foot tall slopes (1:1 slopes) and a 10-foot wide
flat terrace. The ordinance allows 15-foot vertical cuts that are faced with
architectural stone the maximum wall height allowed is 30-feet. The applicant
has stated the total wall height will not exceed 30-feet. The applicant has stated
he will plant pine trees at the bottom edge and the flat terrace of the slope placed
7
August 27, 2015
SUBDIVISION
ITEM NO.: 2 Cont. FILE NO.: S-1280-P
15-feet on center. No seeding or vegetation is proposed to be provided on the
1:1 slope face due to exposed shale. The slope is located on the south property
line from LaMarche Drive to Valley Creek View.
Existing slopes across the site show a 140-foot elevation difference from the
north property line to the south property line. Four (4) defined flow paths enter
the property from the south. The flow paths are directed toward the back of the
lots adjacent to the south property line. Staff is concerned about drainage
coming from the south going down the 30-foot vertical slope and into the back
yards of the proposed new lots. The plat does not allow for access to this area
for maintenance of the diversion ditches that will be located behind the property
fences on the south property line. At the time of this writing staff has not been
provided a sketch grading and drainage plan. It was initially thought the
subdivision would conform to the existing grades. Due to the proposal for the
30-foot slopes staff feels the sketch grading and drainage plan must be provided
for review.
Staff is not supportive of the applicant's request. The purpose of the Land
Alteration Ordinance is to hide hillside scars. In addition based on the lack of
information regarding the grading and drainage for the subdivision there are a
number of questions and concerns which have not been addressed. In addition
the applicant has not provided staff with the sight distance certification as
requested within the subdivision committee comments dated August 5, 2016.
STAFF RECOMMENDATION:
Staff recommends denial of the request.
PLANNING COMMISSION ACTION: (AUGUST 27, 2015)
The applicant was present. There were no registered objectors present. Staff
presented the item stating the request included a variance from the City's Land
Alteration Ordinance to allow advanced grading of the development. Staff stated the
variance request included a cut along the south perimeter of the development. Staff
stated the cut was being proposed with two (2) ten (10) foot cuts at a 1:1 slope and an
additional cut was proposed less than ten (10) feet at a 1:1 slope. Staff stated a
3:1 slope was proposed at the top of the cut and two (2) ten (10) foot wide near flat
terraces were proposed between cuts. Staff stated they were supportive of the variance
for the 15-foot 1:1 slope terraces provided evergreen trees, pine and cedar were
planted on the flat terraces at 15-feet on center between the trees. Staff stated the
trees were to be three (3) to four (4) feet in height. Staff stated vegetation should be
planted on the slope portion of the terraces and temporary irrigation maybe needed to
sustain growth.
0
August 27, 2015
SUBDIVISION
ITEM NO.: 2 (Cont.) FILE NO.: S-1280-P
Staff stated a detail sketch grading plan was provided to staff. Staff stated the sketch
grading plan had not been confirmed nor was the approval of the preliminary plat
confirming the approval of the sketch grading and drainage plan. Staff stated all
drainage specifics and calculations would be reviewed at the time of request for a
grading permit. Staff stated swales were to be provided over all pipes located along the
rear and side lot lines and within the tract land. Staff stated the ten (10) foot wide
easement located between Lots 8 and 9 was to be maintained as access to the tract
lands. Staff stated the area was not to be fenced without approval from the POA. Staff
stated this condition should be reflected in the bill of assurance for the subdivision.
Staff stated all drainage that was not within the public right of way was to be placed
within tract land to be maintained by the POA and not by the City of Little Rock. Staff
stated the bill of assurance was to be drafted to identify and provide maintenance of the
tract lands. Staff stated all cut-off or diversion ditches were to be located within the
tract land or within the 20-foot grading/construction easement located on the southwest
portion of the site.
Staff stated based on the new information provided by the applicant staff was in support
of the request. Staff presented a recommends approval of the request subject to
compliance with the comments and conditions as outlined in paragraphs D, E and F of
the agenda staff report. Staff presented a recommendation of approval of the variance
requests from the subdivision ordinance to allow reduced front, rear and side yard
setbacks. Staff presented a recommendation of approval of the variance request from
the City's land alteration ordinance to allow the grading as proposed.
There was no further discussion. The item was placed on the consent agenda and
approved as recommended by staff by a vote of 11 ayes, 0 noes and 0 absent.
9
ITEM NO.: 2, S-1280-P
NAME: LaMarche Garden Preliminary Plat, located East of the Valley Falls Estates
Subdivision and South of the Gardens at Valley Falls Subdivision
LOCATION: located East of the Valley Falls Estates Subdivision and South of the
Gardens at Valley Falls Subdivision
Planning Staff Comments:
1. Provide notification of the abutting property owners of the development including the
certified abstract list, notice form with affidavit executed and proof of mailing. The
notice must be mailed no later than August 12, 2015. The Office of Planning and
Development must receive the proof of notice no later than August 21, 2015.
Variance/Waivers:
1. A variance from Section 36-245(d) (3) to allow a reduced rear yard setback.
2. A variance from Section 36-254(d) (2) to allow a reduced side yard setback.
3. A variance from Section 36-254(d) (1) to allow a reduced front yard setback.
4. A variance from Section 31-232(e) to allow a reduced width for a corner lot.
Public Works Conditions:
1. To comply with the Master Street Plan, LaMarche Garden Drive should be
constructed to a residential street standard with 50 foot right-of-way and sidewalk on
one (1) side from LaMarche Drive to the west intersection of LaMarche Garden
Loop.
2. Are the streets proposed to be public or private?
3. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
4. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction. Is the subdivision proposed to be phased? If phasing is
desired, is a variance requested to advance grade future phases of construction with
construction of Phase 1 ?
5. Stormwater detention ordinance applies to this property.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
7. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering 501.379.1813, Greg
Simmons (gsimmions@littlerock.org) for more information.
8. An emergency access easement should be provided to the public right-of-way.
Using turn movement templates show the proposed emergency access easement
can be maneuvered by a firetruck (B-40).
9. The street name LaMarche Garden Drive should be changed to "court" or "cove" do
to possible confusion with LaMarche Drive.
10. Provide a letter prepared by a registered engineer certifying the sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
Utilities and Fire Department/County Planning:
Wastewater:
Entergy: Entergy does not object to this proposal. Underground facilities are in
the vicinity to the north and to the west of this development. Contact Entergy in
advance regarding future service requirements to the development, line extensions, and
future facilities locations as this project proceeds.
CenterPoint Energy: No comment received.
AT & T: No comment received.
Central Arkansas Water:
1. All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
2. Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional review.
Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and the Little Rock Fire Department is required.
3. A Capital Investment Charge based on the size of meter connection(s) will apply to
this project in addition to normal charges. This fee will apply to all connections
including metered connections off the private fire system.
4. If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
5. Contact Central Arkansas Water regarding the size and location of water meter.
6. Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZA) is required on the domestic water service.
This assembly must be installed prior to the first point of use. Central Arkansas
Water requires that upon installation of the RPZA, successful tests of the assembly
must be completed by a Certified Assembly Tester licensed by the State of Arkansas
and approved by Central Arkansas Water. The test results must be sent to Central
Arkansas Water's Cross Connection Section within ten days of installation and
annually thereafter. Contact the Cross Connection Section at 501.377.1226 if you
would like to discuss backflow prevention requirements for this project.
7. The facilities on -site will be private. When meters are planned off private lines,
private facilities shall be installed to Central Arkansas Water's materials and
construction specifications and installation will be inspected by an engineer, licensed
to practice in the State of Arkansas. Execution of a Customer Owned Line
Agreement is required.
8. Fire sprinkler systems which do not contain additives such as antifreeze shall be
isolated with a double detector check valve assembly. If additives area used, a
reduced pressure zone back flow preventer shall be required.
9. This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and fire
protection.
Fire Department: Maintain Access:
Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access
road width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Dead Ends. Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4
Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1,
One- or Two -Family dwelling residential developments. Developments of one- or
two-family dwellings where the number of dwelling units exceeds 30 shall be provided
with two separate and approved fire apparatus access roads, and shall meet the
requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private
fire apparatus access road and al dwelling units are equipped throughout with
an approved automatic sprinkler system in accordance with Section
903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two
directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall not
be increased unless fire apparatus access roads will connect with future
development, as determined by the fire code official.
Fire Hydrants. Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water
(Jason Lowder 501.377.1245) and the Little Rock Fire Marshal's Office (Captain Tony
Rhodes 501.918.3757). Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comment received.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Building Code: No comment.
Planning Division: No comment.
Landscape- No comment.
Revised plat/plan: Submit four (4) copies of a revised preliminary plat/plan (to include
the additional information as noted above) to staff on Wednesday, August 12, 2015.