Loading...
HomeMy WebLinkAboutS-1221-F Staff AnalysisMarch 10, 2011 ITEM NO.: 1 FILE NO.: S-1221-F NAME: Chalamont — Chenal Valley Phase 18-K Revised Preliminary Plat LOCATION: Located North of Chalamont Drive, just South of Joe T. Robinson School DEVELOPER: Deltic Timber Corporation 7 Chenal Club Boulevard Little Rock, AR 72223 ENGINEER: White-Daters and Associates 24 Rahling Circle Little Rock, AR 72223 AREA: 26.8 acres CURRENT ZONING: NUMBER OF LOTS: 82 R-2, Single-family LANNING DISTRICT: 19 — Chenal CENSUS TRACT: 42.11 VARIANCESNI/AIVERS REQUESTED: FT. NEW STREET: 3170 LF 1. A variance from Section 31-256 to allow a front building line on a residential lot of twenty (20) feet. 2. A variance from Section 31-256 to allow a ten (10) foot front building line on residential Lots 9, 23, 24 and 63. 3. A variance from Section 36-254(2) to allow side yard setback on each side of the lot at five (5) feet. 4. A variance from the City's Land Alteration Ordinance to allow grading of future phases with the development of Phase I. A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT: The applicant is requesting to amend the previously approved preliminary plat for Phase 18 of the Chalamont Subdivision. The applicant is requesting three (3) variances from various City ordinances. The request includes a variance from March 10, 2011 SUBDIVISION ITEM NO.: 1 (Cont.) FILE NO.: S-1221-F the City's Subdivision Ordinance to allow a front building line of 20-feet and 5-foot side yard setbacks for all the lots proposed for development. Lots 9, 23, 24 and 63 are indicated with a 10-foot front building line. The request also includes a variance from the City's Land Alteration ordinance to allow grading of the entire development with the construction of street improvements in Phase I. The subdivision is proposed in four (4) phases with 20 lots developed in the first phase, 16 lots in the second phase, 20 lots in the third phase and 26 lots developed in the final phase. The average lot sizes proposed are 60-feet by 150-feet and 60-feet by 120-feet. The development is indicated with 3,170 linear feet of new public street constructed to residential street standard. A secondary emergency access is proposed to connect to an existing paved parking area located on the adjacent private recreational area and extend to this subdivision via a 16-foot all weather emergency access. B. EXISTING CONDITIONS: The site is wooded sloping upward from the street to the north. North of the site proposed for development is Joe T. Robinson School and to the west is a private recreational facility. East of the site is a developed single-family subdivision, Bronte Court. South of the site is Chalamont Drive, which as been constructed to Master Street Plan standard. Across Chalamont Drive is the Challain Place Subdivision. C. NEIGHBORHOOD COMMENTS: As of this writing, staff has not received any comment from area property owners. All abutting property owners of the site, the Coalition of West Little Rock Neighborhoods and the Duqesne Place Property Owners Association were notified of the public hearing. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. With site development, provide the design of the street conforming to the Master Street Plan. Construct street improvements to these streets with the planned development. 2. Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501) 379-1805 (Travis Herbner). 3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior to any land clearing or grading activities at the site. Other 2 March 10, 2011 SUBDIVISION ITEM NO.: 1 (Cont. E. FILE NO.: S-1221-F than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. A variance is being requested for advanced grading of future phases with the development of the first phase. 4. Stormwater detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. 5. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from the Arkansas Department of Environmental Quality prior to the start of construction. 6. Street Improvement plans shall include signage and striping. Traffic Engineering must approve completed plans prior to construction. 7. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans for approval to Traffic Engineering. Streetlights must be installed prior to platting/certificate of occupancy. Contact Traffic Engineer 379-1813 (Steve Philpott) for more information. 8. Since the streets are proposed to be 24 feet in width, show on the plan the area of streets where parking will be restricted to one side. 9. Hammerheads should be designed to be at least 80 feet in length and the same width as the street. A hammerhead built to this standard should be provided Caurel Court. 10. The applicant proposes an emergency access across another property. Provide proof of access granted by adjacent property owner. Today the emergency access route is barricaded, not permitting access. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING: Wastewater: Sewer main extension required with easements for this project. Contact Little Rock Wastewater Utility for additional information. Enter : Additional easements are required. A ten -foot easement is required to extend from the existing subdivision to the east to the proposed Caurel Lane. Center -Point Energy: Approved as submitted. AT & T: No comment received. Central Arkansas Water: All Central Arkansas Water requirements in effect at the time of request to water service must be met. A water main extension will be needed to provide water service to this property. Please submit plans for water facilities to Central Arkansas Water for review. Plan revision may be required after additional review. Contact Central Arkansas Water regarding procedures 3 March 10, 2011 SUBDIVISIO ITEM NO.: 1(Cont_ F. G FILE NO.: S-1221-F for installation of water facilities. Approval of plans by Central Arkansas Water, the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). Fire Department: Place fire hydrants per code. The proposed secondary access may not be adequate to serve the development. Contact the Little Rock Fire Department to discuss secondary access alternatives. County Planning: No comment. CATA: The site is not located near a dedicated CATA Bus Route. Parks and Recreation: No comment. ISSUES/TECHNICAL/DESIGN: Planning Division: No comment. Landscape: No comment. SUBDIVISION COMMITTEE COMMENT: (February 17, 2011) Mr. Joe White and Mr. Tim Daters of White-Daters and Associates were present representing the request. Staff presented an overview of the development stating there were few outstanding technical issues associated with the request in need of addressing prior to the Commission acting on the request. Staff questioned if the development would request a fence height variance for the lots abutting the school. Staff questioned if the development would request a variance to allow an increased size for the subdivision identification sign. Public Works comments were addressed. Staff questioned if advanced grading was being requested. Staff stated the hammerheads should be designed to allow at least an 80-foot length and to be the same width as the street to allow for proper maneuvering. Staff noted comments from the other reporting departments and agencies suggesting the applicant contact them individually for additional clarification. There was no further discussion of the item. The Committee then forwarded the item to the full Commission for final action, M March 10, 2011 SUBDIVISION ITEM NO_: 1 (Cont.) FILE NO.: S-1221-F H. ANALYSIS: The applicant submitted a revised preliminary plat to staff addressing the issues raised at the February 17, 2011, Subdivision Committee meeting. The applicant has indicated the subdivision identification sign will be a maximum of six (6) feet in height and thirty-two (32) square feet in area. The subdivision identification sign is consistent with signage allowed per the zoning ordinance. The applicant has indicated a fence height variance for the proposed subdivision will not be required. The revised site plan increases the length of the hammerhead turn arounds as requested by Public Works staff. The request includes a variance from the City's Land Alteration Ordinance to allow advanced grading of the lots with the installation of the basic infrastructure. The applicant has indicated the need to grade the entire site is to allow the site to balance eliminating the need to haul excess materials from the site. The request is to amend the previously approved preliminary plat for Phase 18 of the Chalamont Subdivision. The are variances from the City's Subdivision Ordinances to allow a front building line of 20-feet and 10-feet and 5-foot side yard setbacks. Lots 9, 23, 24 and 63 are indicated with a 10-foot front building line. The remaining lots are indicated with a 20-foot front building line. All lots are proposed with five (5) foot side yard setbacks. The subdivision is proposed in four (4) phases with 20 lots developed in the first phase, 16 lots in the second phase, 20 lots in the third phase and 26 lots developed in the final phase. The average lot sizes proposed are 60-feet by 150-feet and 60-feet by 120-feet. The development is indicated with 3,170 linear feet of new public street constructed to residential street standard. A secondary emergency access is proposed to connect to an existing paved parking area located on the adjacent private recreational area and extend to this subdivision via a 16-foot all weather emergency access. A portion of the subdivision is not located within the City limits of the City of Little Rock. The applicant has indicated Lots 9 - 19 will not be developed until the lots are annexed into the City of Little Rock. The applicant has indicated a number of the streets will be constructed to a minor residential street standard. These streets will be constructed with 24-feet of pavement within a 45-foot right of way. Although the Master Street Plan allows for streets to be constructed to this standard the City typically restricts parking to one side of a minor residential street. Public Works staff has requested the applicant include on the preliminary and final plats the location of the restricted parking. The applicant has not done so. Staff recommends the area of restricted parking be included on the preliminary and final plats. L March 10, 2011 SUBDIVISION ITEM NO.: 1 (Cont. FILE NO.: S-1221-F Staff is supportive of the request to allow the subdivision of this property. The development is proposed consistent with the City's Future Land Use plan for this site with an overall density of 3.06 units per acre. To staff's knowledge there are no remaining outstanding technical issues associated with the request. Staff feels the subdivision and the associated variances is appropriate for the area. STAFF RECOMMENDATION: Staff recommends approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. Staff recommends approval of the following variance request: 1. A variance from Section 31-256 to allow a front building line on a residential lot of twenty (20) feet. 2. A variance from Section 31-256 to allow a ten (10) foot front building line on residential Lots 9, 23, 24 and 63. 3. A variance from Section 36-254(2) to allow side yard setback on each side of the lot at five (5) feet. 4. A variance from the City's Land Alteration Ordinance to allow grading of future phases with the placement of the basic infrastructure within the development. Staff recommends the applicant provide on the preliminary and final plats the area of restricted parking on the streets proposed with 24-feet of pavement. PLANNING COMMISSION ACTION: (MARCH 10, 2011) Mr. Tim Daters and White Daters and Associates was present representing the request. Staff presented the item with a recommendation of approval of the request subject to compliance with the comments and conditions as outlined in paragraphs D, E and F of the agenda staff report. Staff presented a recommendation of approval of the following variance request: 1. A variance from Section 31-256 to allow a front building line on a residential lot of twenty (20) feet. 2. A variance from Section 31-256 to allow a ten (10) foot front building line on residential Lots 9, 23, 24 and 63. N March 10, 2011 SUBDIVISION ITEM NO.: 1 (Cont. FILE NO.: S-1221-F 3. A variance from Section 36-254(2) to allow side yard setback on each side of the lot at five (5) feet. 4. A variance from the City's Land Alteration Ordinance to allow grading of future phases with the placement of the basic infrastructure within the development. Staff also presented a recommendation the applicant provide on the preliminary and final plats the area of restricted parking on the streets proposed with 24-feet of pavement. There was no further discussion of the item. The chair entertained a motion for approval of the item as presented by staff. The motion carried by a vote of 11 ayes, 0 noes and 0 absent. 7