Loading...
HomeMy WebLinkAboutS-1220 Staff AnalysisOctober 15, 1998 ITEM NO.: 6 FILE NO.: S-1220 NAME: Boen Plaza Subdivision - Preliminary Plat LOCATION: Northwest corner of Colonel Glen and Bowman Roads DEVELOPER• ENGINEER: Boen Enterprises, LLC. McGetrick and McGetrick Engineers 10,600 Colonel Glenn Road 319 East Markham, Ste. 202 Little Rock, AR 72204 Little Rock, AR 72201 AREA: 25.5 acres NUMBER OF LOTS: 5 FT. NEW STREET: 300 ZONING• C-2/O-3 PLANNING DISTRICT: 18 CENSUS TRACT: 42.07 VARIANCES/WAIVERS REQUESTED: None A. PROPOSAL• The applicant proposes to subdivide 25.5 acres at the northwest corner of Colonel Glenn and Bowman Roads into five (5) lots. The lots range in size from 0.54 to 7.61 acres. Lots 1 and 2 are zoned C-2 with Lots 3-5 being zoned 0-3. The applicant is proposing to rezone Lots 1 and 2 to PCD (item 6.1 on this agenda) and a conditional use permit for an office-showroom/warehouse on Lot 4 (item 6.2 on this agenda). The applicant has stated that Lots 1, 2 and 4 will be final platted first, with the remaining lots being final platted as dictated by the market. B. EXISTING CONDITIONS: The site is undeveloped and partially wooded. It appears that some of the property, mainly the more level areas, was mostly cleared of trees some time in the past. October 15, 1998 SUBDIVISIO9 ITEM NO.: 6 Cont. FILE NO.: S-1220 The general area has a mixture of uses, including a mobile home park to the north and a few residential structures on large tracts to the west. A large office building is located at the northeast corner of Colonel Glenn and Bowman Roads. There are a couple of single-family structures to the south across Colonel Glenn Road, with a convenience food store and a building supply business located at the southeast and southwest corners of Colonel Glenn and Lawson Roads. There is also a large amount of vacant property in the general area. C. NEIGHBORHOOD COMMENTS: Staff has received no neighborhood comments as of this writing. All adjacent property owners were notified of the proposed preliminary plat. D. ENGINEERING COMMENTS: PUBLIC WORKS CONDITIONS: 1. Colonel Glenn is listed on the Master Street Plan as a principal arterial, dedication of right-of-way to 55 feet from centerline will be required. Minimum horizontal radius at 1,400 feet at centerline for new right-of-way line will be required. 2. Bowman Road is listed on the Master Street Plan as a minor arterial. A dedication of right-of-way to 45 feet from centerline is required plus 10 foot additional for right lane. 3. Driveways shall conform to Sec. 31-210 or Ordinance 16,577. 4. Plans of all work in right-of-way shall be submitted for approval prior to start of work. 5. Stormwater detention Ordinance applies to this property. 6. Easements for proposed stormwater detention facilities are required. 7. Bowman Court is a commercial street which requires sidewalks on both sides, minor commercial 50 foot right- of-way, 27 pavement if less than 300 feet is acceptable. 8. Must have 500 foot minimum sight distance for intersection with Lawson Road. 9. No access from Lot 3 or Lot 5 to Colonel Glenn. Check sight distance for Bowman Road. 10. Provide turn -around for service drive. E. UTILITIES AND FIRE DEPARTMENT COUNTY PLANNING: Wastewater: Sewer main extension required with easements to serve property. AP&L: No Comment received. Arkla: No Comment received. October 15, 1998 r SUBDIVISION ITEM NO.: 6 (Cont.) FILE NO.: S-1220 Southwestern Bell: Utility easements are requested along some internal and exterior property lines. Contact utility for details. Water: An acreage charge of $150 per acre applies in addition to normal charges. A water main extension and on site fire protection will be required for service to some lots. Fire Department: No Comment. County Planning: No Comment received. CATA: Not located on a CATA fixed -route. Site is near Route #14. F. ISSUES/TECHNICAL/RESIGN: Planning Division: No Comment. Landscape Issues: No Comment. G. ANALYSIS: As a result of the staff and Subdivision Committee reviews, staff is requiring that the following items be noted on a revised preliminary plat: a. Name/address of owner and subdivider. b. Need 40 foot building lines on Lots 1 and 2. c. Storm drainage analysis. d. Preliminary storm drainage plan. e. Names of owners of all abutting property. f. zoning of all abutting property. g. City limits line. h. Location of PAGIS Monuments. i. Show cross -access easements for Lots 1 and 2 and Lots 2 and 4. Lots 1 (1.63 acres) and 2 (7.61 acres) are zoned C-2. The minimum lot size for C-2 zoned property is 5 acres. However, Lots 1 and 2 are proposed to be rezoned to PCD which has no minimum lot size. Therefore, if the PCD is not approved or is never developed, then Lots 1 and 2 must be final platted as a single lot or the preliminary plat must be brought back to the Planning Commission to address the appropriate variances. Otherwise, staff can foresee no other outstanding issues associated with this plat. H. STAFF RECOMMENDATIONS: Staff recommends approval of the preliminary plat subject to compliance with paragraphs D, E and G of this report. 3 October 15, 1998 SUBDIVISION ITEM NO.: 6 Cont. FILE NO.: S-1220 SUBDIVISION COMMITTEE COMMENT: (SEPTEMBER 24, 1998) Pat McGetrick was present, representing the application. Staff gave a brief description of the preliminary plat, noting a list of items which need to be shown on a revised preliminary plat. Mr. McGetrick noted that Lots 1, 2 and 4 would be final platted first, with the remaining lots being final platted as they are sold. The need for cross -access easements between Lots 1 and 2 and Lots 2 and 4 was briefly discussed. The location of Bowman Court was also briefly discussed. Mr. McGetrick stated that the cul-de-sac would be located at a point as to create no sight/distance problems. He stated that whatever work necessary would be done to eliminate a potential sight/distance problem. The remaining Public works requirements were briefly discussed with the Committee and applicant. Mr. McGetrick indicated no problem with these requirements. After the presentation, the Committee forwarded the preliminary plat to the full Commission for final action. PLANNING COMMISSION ACTION: (OCTOBER 15, 1998) Staff presented a positive recommendation on this application, as there were no further issues for resolution. There were no objectors to this matter. The Chairman placed the item before the Commission for inclusion within the Consent Agenda for approval as recommended by staff. A motion to that effect was made. The motion passed by a vote of 8 ayes, 0 nays and 3 absent. 4