HomeMy WebLinkAboutResponse to Other Department Comments 012125Page 2 of 2 7. Z-9500-D Rezoning from R-2 to AF (3708 Garrison Road) 1. No comments 8. Z-10126 Orndorff #1 PD-R (1211/1215 College St.) 1. Repair or replace any curb, gutter, sidewalk and access ramps that are missing, damaged, or not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 2. Provide a revised plan showing the proposed driveway locations and widths. 3. With the proposed construction, sidewalk in conformance with ADA recommendations and per CLR details shall be constructed along College St. adjacent to the subject property in conformance with Sec. 31-175 of City code. 9. Z-10127 Orndorff #2 PD-R (1522 Hanger St.) 1. Repair or replace any curb, gutter, sidewalk and access ramps that are missing, damaged, or not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 2. Provide a revised plan showing the proposed driveway locations and widths. 3. A 20 feet radial dedication of right-of-way is required at the intersection of Hanger St. and E. 16th St. 10. Z-10128 Orndorff #3 PD-R (703 E. 21st St.) 1. Repair or replace any curb, gutter, sidewalk and access ramps that are missing, damaged, or not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 2. Provide a revised plan showing the proposed driveway locations and widths. 3. A 20 feet radial dedication of right-of-way is required at the intersection of Bragg St. and E. 21st St. 11. Z-10129 Orndorff #4 PD-R (1207 College St.) 1. Repair or replace any curb, gutter, sidewalk and access ramps that are missing, damaged, or not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 2. Provide a revised plan showing the proposed driveway locations and widths. 3. With the proposed construction, sidewalk in conformance with ADA recommendations and per CLR details shall be constructed along College St. adjacent to the subject property in conformance with Sec. 31-175 of City code. 12. Z-10130 Orndorff #5 PD-R (2117/2121 Rock St.) 1. Repair or replace any curb, gutter, sidewalk and access ramps that are missing, damaged, or not in compliance with ADA recommendations in the public right-of-way prior to occupancy. 2. Provide a revised plan showing the proposed driveway locations and widths. 3. A 20 feet radial dedication of right-of-way is required at the intersection of Rock St. and E. 22st St. Z File Number Z-10128 Orndorff #4 – PD-R 1207 College Street 1. The alley shall be brought to the City of Little Rock Alley Standard. 2. The driveway shall meet City Standard PW-30/32. 3. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard. Lots shall be graded to drain surface water away from foundation walls. The grade shall fall a minimum of 6 inches (152mm) within the first 10 feet (3048mm).Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet (3048mm) of the building foundation shall be sloped a minimum of 2 percent away from the building. Z File Number Z-10128 Orndorff #5 – PD-R 2117/2121 Rock Street 1. The driveway shall meet City Standard PW-30/32. 2. Existing drive apron shall be labeled as, “existing driveway apron to be removed.” 3. Elaborate on the note for 2ft wide swale with curbs. 4. You also can’t discharge to the street as shown. 5. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3 Drainage. Surface drainage shall be diverted to a storm sewer conveyance or other approved point of collection that does not create a hazard. Lots shall be graded to drain surface water away from foundation walls. The grade shall fall a minimum of 6 inches (152mm) within the first 10 feet (3048mm).Exception: Where lot lines, walls, slopes or other physical barriers prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales shall be constructed to ensure drainage away from the structure. Impervious surfaces within 10 feet (3048mm) of the building foundation shall be sloped a minimum of 2 percent away from the building. Contact Dylan Warner at 501-371-5348 Good morning, Here are LRWRA’s comments for the upcoming planning commission meeting. Please let me know if you have any questions. Little Rock Planning Commission – 2/13/25 File Number Title LRWRA Comments Z-10122 Martinez Accessory Dwelling 5301 Rinke Road No Comment Z-10123 Gamzu Duplex 2016 S. Van Buren St. No Comment Z-10124 Ducky’s Premium Auto 7011 Cantrell Road No Comment Z-10125 Pyramid Network Services 3800 Block of Carter Road Sewer is not shown on survey. Please ensure that no permanent structure is placed over LRWRA assets or within easement. Z-10126 Orndorff #1 1211/1215 College No Comments Z-10127 Orndorff #2 1522 Hanger St How will lots 7R2-7R4 receive sewer without crossing each other? Please explain. Z-10128 Orndorff #3 703 E 21st St No Comments Z-10129 Orndorff #4 1207 College St. No Comments Z-10130 Orndorff #5 2117/2121 Rock Street How will lots 7 & 8 receive sewer without crossing lot 9? Please explain. Z-3371-J3 Rezone C2-C4 No Comments Z-5317-B Rezone R2-C3 5924 Baseline No Comments Z-9500-D Rezone R2 to AF 3708 Garrison Rd No Comments If you have any questions about sewer please contact the person below: Terrian Tyler Project Engineer, Developer Funded 11 Clearwater Dr. Little Rock, AR 72204 Office: (501) 688-1431 www.lrwra.com