HomeMy WebLinkAboutZ-10129 Staff Report 012725February 13, 2025
ITEM NO.: 30 FILE NO.: Z-10129
NAME: Orndorff #4 – PD-R
LOCATION: 1207 College Street
DEVELOPER:
Mike Orndorff
609 E. 16th Street
Little Rock, AR 72202
OWNER/AUTHORIZED AGENT:
GarNat Engineering (Agent)
PO Box 116
Bryant, AR 72015
SURVEYOR/ENGINEER:
GarNat Engineering
PO Box 116
Bryant, AR 72015
AREA: 0.16 acre NUMBER OF LOTS: 2 FT. NEW STREET: 0 LF
WARD: 1 PLANNING DISTRICT: 7 CENSUS TRACT: 46
CURRENT ZONING: R-4
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to rezone the property from R-4 to PD-R. The overall 0.16
acre site contains a single lot that will be subdivided into two (2) separate lots.
A one-story, single-family residence will be constructed on each lot. The applicant
will not reside on the property and intends to market both residences for lease/sale
in the future.
B. EXISTING CONDITIONS:
Properties surrounding the site contain a mixture of zoning and uses in all
directions.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS (PLANNING DIVISION):
1. The alley shall be brought to the City of Little Rock Alley Standard.
2. The driveway shall meet City Standard PW-30/32.
3. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3
Drainage. Surface drainage shall be diverted to a storm sewer conveyance
or other approved point of collection that does not create a hazard. Lots shall
be graded to drain surface water away from foundation walls. The grade shall
fall a minimum of 6 inches (152mm) within the first 10 feet (3048mm).
Exception: Where lot lines, walls, slopes or other physical barriers prohibit
6 inches (152mm) of fall within 10 feet (3048mm), drains or swales shall be
constructed to ensure drainage away from the structure. Impervious surfaces
within 10 feet (3048mm) of the building foundation shall be sloped a minimum
of 2 percent away from the building.
ENGINEERING COMMENTS (PUBLIC WORKS):
1. Repair or replace any curb, gutter, sidewalk and access ramps that are missing,
damaged, or not in compliance with ADA recommendations in the public right-
of-way prior to occupancy.
2. Repair or replace any curb, gutter, sidewalk and access ramps that are missing,
damaged, or not in compliance with ADA recommendations in public right-of-
way.
3. With the proposed construction, sidewalks and conformance with ADA
recommendations per CLR details shall be constructed along College Street,
adjacent to the subject property in conformance with Sec. 31-175 of the City
code.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
3
Summit Utilities: No comments received.
AT & T: No comments received.
Central Arkansas Water: No comments received.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied, and the applicant
must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
If you have any additional questions, please contact our office. Contact
Capt. Tony Rhodes at (501) 918-3757, or Fire Marshal Derek N. Ingram
(501) 918-3756.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
4
F. BUILDING CODES/LANDSCAPE:
Building Codes:
As per 2021 Arkansas Fire Prevention Code Volume III R302.1(1) Single Family
Dwellings have the following requirements when dealing with Dwellings that are
closer than 7’ from the property line:
1. If the soffit assembly extends inside of 5’ from the property line, it must be
constructed with fire treated materials. 5/8” Type “X” Drywall, stucco, fire
treated plywood or some other fire treated material on underside of the
soffit, fire treated fascia, elimination of soffit bents and gable vents and crawl
space vents on the affected portion of the wall. Note: Vents must be
relocated to ensure proper venting of the attic space.
a. Exceptions to this are to fire block this section of the exterior wall
from the top plate to the underside of the roof decking and to fire
caulk the blocking at all joints.
2. As per 2021 Arkansas Fire Prevention Code Volume III R302.1(1) Single
Family Dwellings have the following requirements when dealing with
Dwellings that are closer than 5’ from the property line:
a. Exterior walls from 3 to 5’ from the property line must be constructed
of 1-hour fire rated material and the soffit must be constructed from
1-hour fire rated material. Soffit and gable vents are not allowed, and
venting must be relocated to adjacent roof and wall sections.
b. Fire Treated roof decking must extend 4’ up the roof as per the
Authority having jurisdiction.
c. In applications 3’ to 5’ from the dwelling unit to the property line
exterior windows are not allowed to exceed 25% of the wall area.
3. Zero Lot Line Construction must be processed through Zoning for such
allowances. Once processed the following requirements apply.
a. No part of the footing/foundation is allowed to extend beyond the
property line.
b. No overhang is allowed closer than 2’ from the property line and must
be constructed from 1-hour fire treated materials.
c. Roof decking must have 4’ of fire treated material for the entire length
of the wall and turning 4’ along the adjacent wall with hip roof
construction.
d. No windows or doors are allowed when the exterior wall is less than
3’ from the property line. Windows are required in all sleeping rooms.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
5
Utilities:
Utilities are permitted below grade on property but cannot enter where dwellings
are located less than 7’ from the property line. HVAC Units are not permitted
unless there are 7’ setbacks and must be located on dwelling unit property.
Landscape: No comments received.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the I-30 Planning District. The Land Use Plan shows RM for the
requested area. The Residential Medium Density (RM) accommodates a broad
range of housing types including single family attached, single family detached,
duplex, town homes, multi-family and patio or garden homes. Any combination of
these and possibly other housing types may fall in this category provided that the
density is between six (6) and twelve (12) dwelling units per acre. The application
is for a PD-R.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
6
Surrounding the application area to the west, south, and north are single-family
homes in a Medium Density Residential (RM) use area. East of the site is a faith-
based institution in an area of Public/Institutional use.
This site is not located in an Overlay District.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
7
Master Street Plan:
College Street is a Collector on the Master Street Plan. Collectors are designed to
connect traffic from Local Streets to Arterials or to activity centers, with the
secondary function of providing access to adjoining property. The standard Right
of way is 60’. Sidewalks are required on one side of Collectors. This street may
require dedication of right-of-way and may require street improvements.
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
8
Bicycle Plan:
College Street is on the Master Bike Plan as a Proposed Class 3 Bike Route. Class
3 Bike Routes require no additional right-of-way, but either a sign or pavement
marking to identify and direct the route.
Historic Preservation Plan:
This property is not located in a Historic District.
H. ANALYSIS:
The applicant proposes to rezone the property from R-4 to PD-R. The overall 0.16
acre site contains a single lot that will be subdivided into two (2) separate lots. A
one-story, single-family residence will be constructed on each lot. The applicant
will not reside on the property and intends to market both residences for lease/sale
in the future.
Properties surrounding the site contain a mixture of zoning and uses in all
directions.
The subject property is proposed to be re-platted into two (2) separate lots. Lot
dimensions are shown as approximately 25’ x 140’ square feet.
Each lot will contain a one-story, single-family residence. Each residence will be
approximately 988 square feet in area. The residences will have front porches
with depths of eight (8) feet. The proposed residences will have front setbacks of
twenty-five (25) feet, rear setbacks of 53.2 feet, and side setbacks of 5.1 feet and
four (4) feet.
Section 36-502(b)(1)(a) requires one parking space for each single-family
residence. Each residence will contain a single 15-foot wide, concrete driveway
extending from College Street. Staff feels the parking is sufficient to serve the
proposed use.
The building height for each residence shall not exceed thirty-five (35) feet in
height.
The applicant notes that the exterior of each residence will be vinyl siding, and the
roof will contain asphalt roofing shingles.
The applicant is not proposing any signage at this time. Any future signage must
comply with Section 36-551 of the City’s Zoning Ordinance (signs permitted in
residential one – and two – family zones).
February 13, 2025
ITEM NO.: 30 (Cont.) FILE NO.: Z-10129
9
To Staff’s knowledge, there are no outstanding issues associated with this
application. Staff feels that the proposed development is an appropriate use for
the subject property. Staff feels the proposed development will not be out of
character with the development pattern within the area. Properties in the general
area contain a mixture of residential zoning and uses with some properties
containing a higher density than the proposed development. Although there will
be a minor increase in traffic, staff feels the proposed development will not have
an adverse impact on the surrounding properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested PD-R rezoning, subject to
compliance with the comments and conditions outlined in paragraph D, E and F,