HomeMy WebLinkAboutResponse to other departments comments 01
Civil Engineering Review Comments ☐ Board of Adjustment ☒Planning Commission
Agenda Date: 02/13/2025
G & S & Z & LU File Numbers, Z-10122, Z-3371-J(3), Z-5317-B, LU2025-30-01, Z-9500-D No
comments.
Z File Number Z-10123
Gamzu Duplex - CUP 2016 S. Van Buren St.
1. Extend your driveway to meet S. Van Buren St. and ensure your drive does not
exceed 20 feet in width Per City Code 30-43.
2. With what is shown how do you plan on moving the vehicles on site? As of
right now the cars have nowhere to back up or maneuver.
3. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3
Drainage. Surface drainage shall be diverted to a storm sewer conveyance or
other approved point of collection that does not create a hazard. Lots shall be
graded to drain surface water away from foundation walls. The grade shall fall
a minimum of 6 inches (152mm) within the first 10 feet
(3048mm).Exception: Where lot lines, walls, slopes or other physical barriers
prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales
shall be constructed to ensure drainage away from the structure. Impervious
surfaces within 10 feet (3048mm) of the building foundation shall be sloped a
minimum of 2 percent away from the building.
Z File Number Z-10124
Ducky’s Premium Auto Spa – CUP 7011 Cantrell Road
1. Provide full site plan. What is going on at the North side of your property? You
have a red line and arrow yet the drawing is cut off.
Z File Number Z-10125
Pyramid Network Services – Tower Use Permit 3800 Block of Carter Road
1. Driveway apron that connects with Carter Road shall meet City Standard Detail
PW-34. This means that it should meet all design standards and material
standards. (concrete, 1.5inch lip, radius curb, etc.)
Z File Number Z-10126
Orndorff #1 – PD-R 1211/1215 College St.
1. The alley shall be brought to the City of Little Rock Alley Standard.
2. The driveway shall meet City Standard PW-30/32.
3. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3
Drainage. Surface drainage shall be diverted to a storm sewer conveyance or
other approved point of collection that does not create a hazard. Lots shall be
graded to drain surface water away from foundation walls. The grade shall fall
a minimum of 6 inches (152mm) within the first 10 feet
(3048mm).Exception: Where lot lines, walls, slopes or other physical barriers
prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales
shall be constructed to ensure drainage away from the structure. Impervious
surfaces within 10 feet (3048mm) of the building foundation shall be sloped a
minimum of 2 percent away from the building.
Z File Number Z-10127
Orndorff #2 – PD-R 1522 Hanger Street
1. The driveway shall meet City Standard PW-30/32.
2. Is this on street parking proposed? If not show the drives.
3. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3
Drainage. Surface drainage shall be diverted to a storm sewer conveyance or
other approved point of collection that does not create a hazard. Lots shall be
graded to drain surface water away from foundation walls. The grade shall fall
a minimum of 6 inches (152mm) within the first 10 feet
(3048mm).Exception: Where lot lines, walls, slopes or other physical barriers
prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales shall
be constructed to ensure drainage away from the structure. Impervious surfaces
within 10 feet (3048mm) of the building foundation shall be sloped a minimum
of 2 percent away from the building.
Z File Number Z-10128
Orndorff #3 – PD-R 703 E. 21st Street
1. The driveway shall meet City Standard PW-30/32.
2. Is this on street parking proposed? If not show the drives.
3. Arkansas Fire Prevention Code 2021 Chapter 4 Foundations Section R401.3
Drainage. Surface drainage shall be diverted to a storm sewer conveyance or
other approved point of collection that does not create a hazard. Lots shall be
graded to drain surface water away from foundation walls. The grade shall fall
a minimum of 6 inches (152mm) within the first 10 feet
(3048mm).Exception: Where lot lines, walls, slopes or other physical barriers
prohibit 6 inches (152mm) of fall within 10 feet (3048mm), drains or swales
shall be constructed to ensure drainage away from the structure. Impervious
surfaces within 10 feet (3048mm) of the building foundation shall be sloped a
minimum of 2 percent away from the building.
Good morning,
Here are LRWRA’s comments for the upcoming planning commission meeting. Please let
me know if you have any questions.
Little Rock Planning Commission – 2/13/25
File
Number
Title LRWRA Comments
Z-10122 Martinez Accessory
Dwelling
5301 Rinke Road
No Comment
Z-10123 Gamzu Duplex
2016 S. Van Buren St.
No Comment
Z-10124 Ducky’s Premium Auto
7011 Cantrell Road
No Comment
Z-10125 Pyramid Network
Services
3800 Block of Carter Road
Sewer is not shown on survey.
Please ensure that no
permanent structure is placed
over LRWRA assets or within
easement.
Z-10126 Orndorff #1
1211/1215 College
No Comments
Z-10127 Orndorff #2
1522 Hanger St
How will lots 7R2-7R4 receive
sewer without crossing each
other? Please explain.
Z-10128 Orndorff #3
703 E 21st St
No Comments
Z-10129 Orndorff #4
1207 College St.
No Comments
Z-10130 Orndorff #5
2117/2121 Rock Street
How will lots 7 & 8 receive sewer
without crossing lot 9? Please
explain.
Z-3371-J3 Rezone C2-C4 No Comments
Z-5317-B Rezone R2-C3
5924 Baseline
No Comments
Z-9500-D Rezone R2 to AF
3708 Garrison Rd
No Comments
If you have any questions about sewer please contact the person below:
Terrian Tyler
Project Engineer, Developer Funded
11 Clearwater Dr.
Little Rock, AR 72204
Office: (501) 688-1431