Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Z-10061 Cross-Section 112124
B 6 SLOPE FINISH GRADE 5% FOR 10'-0" FROM HOUSE FROST DEPTH PER LOCAL CODE CONCRETE FOOTINGS ALUMINUM FASCIA & SOFFIT W/ VENTS 2 X 6 SUBFASCIA G.I. DRIP EDGE 7/16" OSB / PLYWOOD ROOF SHEATHING VAPOR BARRIER ASPHALT SHINGLE ROOFING OVER 30# FELT 2 X 6 P.T. SILL PLATE ANCHOR BOLT PER STRUCTURAL DRAWINGS 2 X 6 STUDS @ 16" O.C. W/ R-13 INSULATION 7/16" OSB / PLYWOOD WALL SHEATHING VAPOR BARRIER 1" EPS FOAM INSULATION STUCCO FINISH BRICK WAINSCOT PRE-MANUFACTURED WOOD TRUSSES @ 24" O.C. (ENGINEERING PROVIDED BY MANUFACTURER) 1/2" GYPSUM BOARD ON WALLS & CEILINGS H1 CLIP @ EACH TRUSS 12 4 R-38 INSUL. IN ROOF 12 4 4" CONCRETE SLAB PER STRUCTURAL DRAWINGS9'-1" WALL HEIGHT8'-0" HEADER HEIGHT2 X 4 INTERIOR STUDS @ 16" O.C. 2 X 8 HEADER BRICK LEDGE AS NEEDED FINISH GRADE VAPOR BARRIER7/16" OSB / PLYWOOD WALL SHEATHING 2 x 6 PRESSURE TREATED SILL PLATE A.B. PER STRUCT. SPECS CONCRETE SLAB WHERE OCCURS 26 GA. CORROSION- RESISTANT J-METAL STUCCO EXTERIOR 4" MIN.2" MIN.6" MIN.WEEP SCREED 6 CROSS SECTION65 W WARREN AVECOLORADO CITY, AZ 86021 PHONE: (435) 525-3503OFFICE@EVOLUTIONDRAFTING.COMALL RIGHTS RESERVEDPAGE # ISSUE DATES: 11/06/2024 DRAWN BY: JMTEVOLUTION DRAFTING LLCPROPOSED RESIDENCEFORMENDEZ CONSTRUCTIONLOT 1 (.33 ACRE)7524 FAIRFIELD DRIVELITTLE ROCK, ARKANSAS 7220911/08/2024 WEEP SCREED DETAIL B/6 SCALE:1" = 1'-0" CROSS SECTION A/6 SCALE:1/2" = 1'-0"