HomeMy WebLinkAboutResponse to CommentsHope Consulting Engineers 129 North Main Street Benton, Arkansas, 72015 (501) 315-2626 October, 17th 2024 City of Little Rock Planning and Development Planning Commission dstafford@littlerock.gov and tthrower@littlerock.gov RE: Z-10061 Flores Office-Warehouse – PD-O 7524 Fairfield Drive Development Staff Comments & Responses: 1. Provide building elevations. Conceptual elevation has been added to the plan sheet. 2. Provide cross-sections. Cross-sections have been requested from the architect. 3. Provide uses that are to take place within each building. This information from the architect has been requested. 4. Show locations of the two garage doors as referred to in the cover letter. The floor plan that will provide this information has been requested from the architect. 5. Will there be a dumpster on site? If so, it will be required to be screened according to section 36-523 (d) of the zoning code. A roll-out dumpster application will be used or this project. 6. Provide, at a minimum, a six (6) foot tall opaque fence along the East property line as per code requirements. Fence has been added and called out on plan. 7. Any sight lighting must be low-level and directed away from adjacent properties. All lighting will comply and be placed on the building. 8. Any new signage placed on-site must comply with Section 36-553 of the Zoning Code. Signage will comply with all zoning regulations that apply. 9. Provide hours and days of operation. Monday thru Friday, 8am-5pm. Maintain Access Comments & Responses: Fire Hydrants: Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Entrance access drive has been widened to be 26' wide. Grade: Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade: Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. If the grade exceeds 10 percent, approval will be denied and the applicant must submit request to be reviewed by Fire Chief for Approval. The access road will not exceed 10 percent grade. Loading: Maintain fire apparatus access road design as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Plans comply with this code section requirement. Commercial and Industrial Developments – 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet in height shall have at least two means of fire apparatus access for each structure. Not applicable. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provided with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. Not applicable. This building's footprint is only 1500 square feet. Section D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. Not applicable, this building doesnt require two access roads. 30' Tall Buildings – Maintain aerial fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D105.1 – D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of parapet walls, whichever is greater. Not applicable, building is not 30' tall. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed width of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. Entrance access drive has been widened to be 26' wide. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approval of the fire code official. Not applicable. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Existing overhead power lines are in place already. Dead Ends: Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-End fire apparatus access roads. Adequate turn around space has been provided. Gates: Maintain fire apparatus access road gates as per Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access roads gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: Gate requirement is not applicable. 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval by the fire code official. 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200.