HomeMy WebLinkAboutS-0173-A Staff AnalysisOctober 13, 1981 SUBDIVISIONS Item No. 3 NAME: Kanis Place - Site Plan Review LOCATION: Off Kanis on Michael Drive REQUEST: For multiple building site plan review of an area currently zoned "MF-24" and "MF-12" for residential use. DEVELOPER: APPLICANT/ENGINEER: Sanders and Associates Robert A. Richardson Consulting Engineers, Inc. 7101 W. 12th St., Suite 400 Little Rock, AR 72204 AREA: 9.15 Acres FT. OF NEW STREET: 0 ZONING: "MF-24" and "MF-12" PROPOSED USES: Apartments nnnnnerr . 1. The construction of 106 residential units on 9.15 acres. 2. Development according to the following schedule of units: No. of No. of Total Unit Type Units Bidgs. Sq.Ft. One Bedroom Walkup 8 1 5,200 Two Bedroom Walkup 64 4 57,408 Three Bedroom Townhouse 30 5 35,190 Four Bedroom Detached 4 4 5,512 Total 106 I4 103,310 3. The provision of 164 spaces for parking. PROPOSED USES: Apartments October 13, 1981 SUBDIVISIONS Item No. 3 - Continued SPECIAL REQUIREMENTS I. Parking requirements for multifamily development is 1.5 spaces per unit. This plan complies. 2. Multifamily subdivisions that abut single family areas shall protect such areas from adversities by providing a minimum 40' buffer strip and a fence of opaque nature, except where a 25' permanent landscaped rear yard is provided, the buffer may be reduced to 25'. In this arrangement, mo structural or physical improvements are allowed within the buffer. The 6' fence required will apply. 3. A landscaping/screening plan that meets Ordinance requirements should be submitted. A landscaping plan has been submitted. ENGINEERING CONSIDERATOINS (a) Street and drainage structures were never inspected or accepted by the City. As -built street and drainage plans that include drainage calculations are required. Some sections of Michael Drive may require reconstruction. (b) The partial construction on the part of Michael Drive from this plat to Kanis cannot be accepted without total review of Michael Drive design. ANALYSIS This was submitted for site plan review because of the multiple buildings on the site. Staff has no major objections to the plan as presented. In fact, it is an impressive layout that proposes to shield the adjacent single family area through landscaping and the use of a detached four bedroom unit design on the boundary that abuts the area. The applicants have worked closely with Staff in the past to come up with a suitable proposal. The only comments offered are that (1) Michael Drive should be improved to collector standards in conjunction with this plat; (2) Michael Kanis should be listed on the plat; and (3) the zoning should be down -zoned in order to conform with the density of the property. STAFF RECOMMENDATION Approval, subject to Staff's and Engineering's comments. October 13, 1981 SUBDIVISIONS Item No. 3 - Continued SUBDIVISION COMMITTEE ACTION After a brief discussion, the Committee decided that Michael Drive should not be included as a part of this plat; however, the applicant was' -required to furnish Staff with a letter from the developer and his clients stating that Michael Drive will be built. The applicant agreed to provide a 6' fence on that portion of the property abutting the single family area. A motion to approve the plan, as submitted, was made and passed by a vote of 3 ayes, 0 noes and 2 absent. PLANNING COMMISSION ACTION The applicant was present. There were no objectors. After a brief discussion, the applicant decided to amend the application to include Michael Drive on the plat. A motion for approval as amended was made and passed by a vote of 7 ayes, 0 noes and 4 absent.