Loading...
HomeMy WebLinkAboutS-0106 Staff AnallysisJuly 24, 1979 ,,rram� SUBDIVISIONS Item No. 16 NAME: River Oaks Condominiums LOCATION: Northwest corner Riverfront Drive and Turtle Creek Lane DEVELOPER: ENGINEER: Construction Unlimited Mehlburger Engineers, Inc. of Arkansas 201 S. Izard 6520 Baseline Little Rock, AR 72201 Little Rock, AR Phone: 375-5331 AREA: 14 Acres NO. OF LOTS: 1 FT. OF NEW STREET: 0 ZONING: "F", "D" and "MF-18" PROPOSED USES: Condominiums (216) PLANNING DISTRICT: 23 CENSUS TRACT: 16 VARIANCE REQUESTED: 35' building line on Riverfront Drive. ,YW r July 24, 1979 Item No. 16 - Continued A. Existing Conditions Tract A-3 of Riverdale Addition is adjacent to and south of Round River Condominiums; Phase I of which was approved at last month's Commission meeting. The ground is similar being part of the old golf course and is bounded on the east by the levee. At the southeast corner of this parcel is a sump area and pump that serves to drain the entire Riverdale area. All streets and utilities have been built, and adjacent sidewalks are required as a condition of individual building permits under the terms of the original approval. B. Development Proposal The proposal is to develop 216 condominium apartment units on 14 gross acres with a density of 15.4 units/acre. Deducting 4 1/2 acres or so for levee and sump would yield a density of about 22 1/2 units/acre. Service easements are proposed in the form of a series of loops off a central major access easement with a single entrance on Turtle Creek Lane. Rezoning is proposed to eliminate existing "F" and "D" zoning to make the entire site "MF-18." The new Subdivision Ordinance literally requires a 40' buffer and 6' screen on the north side. We feel that 40' would be excessive in a case like this, but that 25' would be reasonable as has been required of a similar development. A 35' building line has previously been platted along Riverfront Drive. Current standard is 401. C. Analysis The staff feels that the proposed density is too high for a project of this type; and that a design which was focused on central areas containing recreational amenities would be better than the linear rank and file layout shown. 40 77 July 24, 1979 Item No. 16 - Continued D. Staff Recommendation The staff recommends that approval be subject to: 1. A 25' undisturbed buffer and 6' screen on the north side. 2. Rezone to "MF-18." 3. Approve 35' building line. 4. Compliance with other codes such as landscaping, building, etc. 5. Consider possible redesign as in C. above. Subdivision Committee Recommendation: The Subdivision Committee recommends approval subject to: (see Items 1 - 5 above). 1. 12.5' undisturbed buffer and 3' to 4' landscaped earthen berm on the north side. y 2. Rezone to "MF-18." 3. Approve 35' building line. 4. (Delete.) 5. (Delete.) Planning Commission Action: The applicant was present and stated that he had no problems with the Committee recommendations. The Commission voted to approve the plat as recommended by the Subdivision Committee unanimously.