HomeMy WebLinkAboutS-1706 ApplicationLittle Rock Wastewater Comments '
Project Number S-1706
Project Name
Project Type
West Polaski volunteer Fire
Preliminary Plat
Station
Project Number 5-1707
Project Name
Project Type
2317 Willow Springs Road
Site Plan Review
Subdivision
Project Number S-57-YY
Project Name
Project Type
LIV Riverdale Subdivision
Site Plan Review
Project Number Z-1718-A
Project Name
Project Type
MacArthur Commons
Planned Commercial Development
Project Number Z-2582-A
Project Name
Project Type
Out In The Woods
Planned Residential Development
Apartments
Project Number Z-5703-D
Project Name
Project Type
Lot 3 Colonel Glenn
Planned Commercial Development
Business Center
Project Number Z-7622-D
Project Name
Project Type
Kinnaman Self Park
Planned Commercial Development
Project Number Z-7875-D
Project Name
Project Type
Taylor Park Lot 57A-57C
Planned Office Development
Comment Made
Outside Service Boundary, no comment.
Comment Made
Outside Service Boundary, no comment.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project. Sewer mains on site are
privately owned and operated.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project.
Comment Made
Sewer main extension required with easements to serve
Lots 57B & 57C..
Monday, July 22, 2013 Page 1 of 2
Project Number Z-7919-D
Project Name
Project Type
Comment Made
Rock City Marina and Yacht
Planned Commercial Development
54" and 60" Outfall located in Vicinity of Project. No
Club
construction allowed with Easement of Existing Outfall.
Project Number Z-8194-A
Project Name
Project Type
Comment Made
TL Addition
Planned Residential Development
Sewer main extension required with easements for this
project.
Project Number Z-8833-A
Project Name
Project Type
Comment Made
Massey
Planned Commercial Development
Outside Service Boundary, no comment.
Project Number Z-8878
Project Name Project Type Comment Made
Southern Star Concrete Inc. Planned Development Industrial Sewer available to this project.
Project Number Z-8879
Project Name Project Type Comment Made
Epperson Planned Residential Development Sewer available to this project.
Monday, July 22, 2013 Page 2 of 2
Public Works Review Comments
Planning Commission Board of Adjustment
Agenda Date: 8-22-13
Z File Number LA-0054
Village at Brodie Creek lot 12 Advance Grade Col. Glen @ I430
facility(s).
1 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
2 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
Per Sec. 29-197(9) storm water detention must be constructed on site in accordance with Chapter 29
and maintained following completion of grading activities. Show location(s) of detention
4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
5 Retaining walls designed to exceed 15 ft in height are required to seek a variance for construction.
Provide proposed wall elevations.
6 Prior to construction of retaining walls, a engineer's certification of design and plans must be
submitted to Public Works for approval. After construction, an as -built certification is required for
construction of the retaining wall.
7 Per Sec. 29-197(2), the grading shall be expeditously completed in a time frame not to exceed one
(1) year in duration from the time work commences to installation of all final erosion control
measures and vegetation.
8 Per Sec. 29-197(3) provide line of sight illustrations from adjacent street(s) and properties for review
by the Planning Commission.
9 Per Sec. 29-179(5), undisturbed areas designated for temporary buffers shall be kept undisturbed
except for reasonable access to the site. The width of the temporary buffer strip shall be 6% of
the
lot width and depth. The minimum width shall be 50 ft where the property is adjacent to other
properties. The minimum width shall be 80 ft where the subject property is adjacent to arterial
streets (W. 36th St & Bowman Road). In no event shall these temporary strips be less than the
width of the permanent buffers required for the development. The minimum required width shall not
exceed 100 ft. Label and delineate undisturbed buffer areas.
10 Construction access points should be shown on the grading plan.
11 Per Sec. 29-197(11), a permanent vegetative cover of suitable perennial grass shall be established over
all disturbed areas. Where indicated by soil tests, pH adjustments and addition of fertilizer may be
required.
12 At the completion of land alteration activities, a minimum of 6 inches of suitable top soil shall be
placed over all disturbed areas and permanent vegetative cover shall be established. Top soil shall
suitable clay or silt loam soil capable of supporting perennial vegetation. If on -site soil is suitable,
the top soil may be stripped from the site prior to grading, or suitable soil may be brought in from
off -site.
Monday, July 29, 2013 Page I of 8
13 Per Sec. 29-197(12), all erosion and stabilization controls, including permanent vegetation and
plantings and stormwater detention systems are to be maintained by the responsible part for a
period of 2 years following completion of site grading.
14 Per Sec. 29-197(12), periodic mowing, generally 2 times per year or more often if required by CLR
shall be provided to encourage perennial grass growth.
15 Per Sec. 29-197(13), maintenance for the 2 year period shall be guaranteed through posting of cash,
surety bond or letter of credit as referenced in Sec. 31-431(2) at the time of final inspection of the
grading activities.
16 Per Sec. 29-197(14), all required federal, state, and local permits and approvals shall be obtained prior
to commencement of land alteration activities.
17 Public works staff must be contacted for inspection for final approval of site stabilization prior to
acceptance and relinquishment of maintenance bond.
18 Staked orange fencing must be installed along the open space undisturbed buffer areas during
construction to prevent access to these buffer areas.
19 Plans shall provide for visual screening of the completed area by providing undisturbed perimeter
buffer strips and earthen berms. Berms should be constructed adjacent to the constructed Brodie
Creek Blvd. and adjacent to the future Brodie Creek Blvd. if the property does not develop
simultaneously. A berm should be installed along the southern property line of Lot 11. A berm
should be installed adjacent to the future Brodie Creek Cove if the property does not develop
simultaneously.
20 Prior to the issuance of a grading permit, vegetation must be established on all disturbed areas in the
subdivision not currently under construction.
Z File Number S-1706
West Pulaski Fire Station Preliminary Plat 8503 Pinnacle Valley Rd
I Pinnacle Valley Road is classified on the Master Street Plan as a minor arterial. A dedication of
right-of-way 45 feet from centerline will be required.
2 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
3 A 20 feet radial dedication of right-of-way is required at the intersection of Pinnacle Valley Rd and
Beck Rd.
Z File Number S-1707
2317 Willow Springs Rd. Sub. Site plan Review 2317 Willow Spring Rd.
0 No comments
Z File Number S-57-YY
LIV Riverdale Sub. Site Plan Review 1200 Brookwood Dr.
1 Sidewalks with appropriate handicap ramps are required to be constructed along Brookwood Drive in
accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. The existing
handicap ramp at the intersection of should be constructed to a Type 2 standard.
Monday, July 29, 2013 Page 2 of 8
2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
4 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
5 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
6 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
7 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
8 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. Driveway spacing on Brookwood Drive is 125 ft from property lines and 250 ft
from other driveways or intersections. The width of driveway must not exceed 36 feet.
9 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
10 Provide a to scale site plan.
Z File Number Z-1718-A
McArthur Commons Short -form PCD 400 East Capitol
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 Show locations where any building improvements are proposed to extend into the public right-of-way.
3 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
4 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private
improvements located in the right-of-way.
5 The existing stormwater pipe adjacent to River Market Ave is an undersized 12 inch dia. pipe with 3
inlets. When the underground system is at capacity the storm is passed over the street to 4th St. and
then east to Sherman St.
Z File Number Z-2582-A
Out in the Woods Apt. Long -form PD-R 9201 Kanis Rd.
1 The proposed right-of-way dedication meets Master Street Plan requirements.
Z File Number Z-5703-D
Lot 3 Col. Glenn Business Center PCD 4701 S. Shackleford Rd.
Monday, July 29, 2013 Page 3 of 8
I With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvements to Shackleford Road including 5-foot sidewalks with planned
development. The new back of curb should be located 29.5 ft from centerline.
2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
3 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
5 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
6 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Z File Number Z-7622-D
Kinnaman Self Park Short -form PCD SEC Chenal & Wellington Hills
1 Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way
45 feet from centerline will be required. An additional 10 ft of ROW is required to be dedicated for a
length of 250 ft.
2 A 20 feet radial dedication of right-of-way is required at the intersection of Kanis Road and
Wellington Hills Road.
3 With expansion of development, provide design of street conforming to the Master Street Plan.
Construct one-half street improvement to Kanis Road including 5-foot sidewalks with planned
development.
4 In accordance with Section 31-176, floodway areas must be shown as floodway easements or be
dedicated to the public. In addition, a 25 foot wide access easement is required adjacent to the
floodway boundary.
5 A substantial area of the site lies within the regulated floodway and floodplain of Rock Creek. No
future construction of any structures, improvements to the interior of the structures over 50% of the
market value of the structure, parking areas, or placement of fill within the floodway.
6 Storm water detention ordinance applies to this property. If expansion is planned show the proposed
location for stormwater detention facilities on the plan.
Z File Number Z-7875-D
Taylor Park lot 57 Revised POD
SWC Kanis & Taylor Park Blvd.
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 The existing sidewalk should be placed within a sidewalk easement.
3 In accordance with Section 32-8, no obstruction to visibility shall be located within a triangular area
50 ft back from the intersecting right-of-way line (or intersecting tangent lines for radial dedications) at
the intersection of Taylor Park Blvd. with Kanis Road.
Monday, July 29, 2013 Page 4 of 8
4 Prior to construction of retaining walls, a engineer's certification of design and plans must be
submitted to Public Works for approval. After construction, an as -built certification is required for
construction of the retaining wall.
Z File Number Z-7919-D
Rock City Marina & Yacht Club Long -form PCD East 3rd St
1 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Bond Avenue including 5-foot sidewalks with planned
development.
The new back of curb should be located 18 ft from centerline.
2 With site development, provide design of street conforming to the Master Street Plan. Due to the
proposed traffic volumes accessing the site, full street improvements to 2nd Street west from Bond
Avenue including 5-foot sidewalks should be constructed with planned development. 2nd
Street
379-
grading
must
should be constructed to a 36 ft width. A pedestrian crosswalk should be installed at the east leg of
the 2nd St -Bond Ave intersection.
3 The public right-of-way will end at the crosswalk west of the parking area west of the round -a -bout.
A concrete driveway apron should be installed where the public right-of-way ends on 2nd Street at
the 4 driveways accessing the accessing the park, apartments, marina, and launch.
4 Due to the proposed use of the property, the Master Street Plan specifies that 2nd Street for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet
from centerline.
5 Due to the proposed use of the property, the Master Street Plan specifies that Bond Avenue for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet
from centerline.
6 Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain
barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501)
1805 (Travis Herbner).
7 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
8 A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to
construction.
9 The minimum finished floor elevation of the inhabitable structures on the property must be at least 1
ft above the base flood elevation and shown on any approved plans and/or plats.
10 Alteration of the water course will require approval from the Little Rock District of the US Army
Corps of Engineers prior to start of work. The permit has been issued.
11 The proposed site is within the adopted regulatory floodway. The proposed alteration of the
floodway will require flood map revisions. Obtain a conditional letter of map revision approval
from Public Works and the Federal Emergency Management Agency prior to issuance of a
permit and/or a building permit. At completion of construction, a final letter of map revision
be submitted and approved by the Federal Emergency Management Agency prior to the issuance of
the final certificate of occupancy.
12 Street Improvement plans shall include signage and striping. Traffic Engineering must approve
completed plans prior to construction.
13 Alteration or use of the levee will require approval from the Little Rock Pulaski County Levee
District prior to the start of work.
Monday, July 29, 2013 Page 5 of 8
more
provided.
back
14 Per Sec. 36-341 no structure shall be closer than twenty-five (25) feet to any established floodway
line. The storage or processing aboveground and the storage belowground of material and fuel
which
is flammable or explosive or which could other wise be injurious to human, animal or plant life in
time of flood shall be unlawful. Floodways shall be kept free of structural involvement including
15 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact
Traffic Engr 379-1813 (Steve Philpott) for more info.
16 Obtain permits prior to doing any street cuts or curb cuts. Obtain barricade permit prior to doing any
work in the right-of-way. Contact Traffic Engineering at (501) 379-1805 (Travis Herbner) for
information.
17 The proposed park design should be reviewed by the Little Rock Parks Dept. Contact Mark Webre
at 371-6851 for additional assistance.
18 Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to
issuance of a certificate of occupancy.
19 Provide the grading and construction phasing plan.
20 Due to the proposed use of the property, the Master Street Plan specifies that 3rd Street for the
frontage of this property must meet commercial street standards. Dedicate right-of-way to 30 feet
from centerline.
21 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to 3rd St including 5-foot sidewalks with planned development. The
new back of curb should be placed at 18 ft from centerline with at least 20 ft of pavement
22 Prior to construction of retaining walls, a engineer's certification of design and plans must be
submitted to Public Works for approval. After construction, an as -built certification is required for
construction of the retaining wall.
23 Private access is proposed for the property east of 3rd St. off the abandoned Kimball Street In
accordance with section 31-207, private streets must be designed to the same standards as public
streets. A minimum access easement width of 45 ft is required and street width of 31 ft from
of curb to back of curb with sidewalks. A concrete apron must be installed at the intersection of the
private street and 4th St.
Z File Number Z-8194-A
TL add. Short -form PD-R 14401 Taylor Loop RD.
1 Private access is proposed for these lots. In accordance with section 31-207, private streets must be
designed to the same standards as public streets. A minimum access easement width of 45' is
required and street width of 24' from back of curb to back of curb.
2 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
3 Street grades cannot exceed 16%. Provide a sketch grading and drainage plan.
4 A minimum 20 ft wide all weather, secondary emergency access must be provided for subdivisions
with 30 or more residential dwellings. Show location of the access.
5 Retaining walls designed to exceed 15 ft in height are required to seek a variance for construction.
Provide proposed wall elevations.
6 Building lines show to extend into the access easement.
7 Taylor Loop Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline will be required. Show the centerline of Taylor Loop Road.
8 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
9 Storm water detention ordinance applies to this property.
10 Provide a letter prepared by a registered engineer certifying the sight distance at the intersection of
Taylor Loop Road and the proposed street complies with 2004 AASHTO Green Book standards.
11 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
12 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
13 If gates are proposed to be installed, a turn around must be provided for a SU-30 vehicle attempting
to enter development. A stacking distance of 30 feet from pavement must also be provided.
14 Street names and street naming conventions must be approved by Public Works. Contact Glenn
Haley at (501) 371-4537.
15 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
16 Show the existing curb and gutter and driveways on Taylor Loop Road in the grading and drainage
plan.
17 No residential waste collection service will be provided on private streets unless the property owners
association provides a waiver of damage claims for operations on private property.
18 Since the street is proposed to be 24 ft in width, show on the plan the area of street where parking
will be restricted to one side.
19 Is access proposed to be provided from Black Bear Drive?
Z File Number Z-8833-A
Massey Short -form PCD 7120 Hwy 300
1 Hwy 300 is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45
feet from centerline will be required.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvements to Hwy 300 including 5-foot sidewalks with planned development. The
new back of curb should be placed 29.5 ft from centerline adjacent to the subject property.
3 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
Monday, July 29, 2013 Page 7 of 8
5 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
6 Driveway locations do not meet the traffic access and circulation requirements of Sections 3043 and
31-210. The lots must share a single driveway access centered on the property line. The width of
driveway must not exceed 36 feet. Driveways are required to be spaced 150 ft from property lines and
300 ft from other driveways.
7 Provide a letter prepared by a registered engineer certifying the sight distance at the intersections
comply with 2004 AASHTO Green Book standards.
8 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI.
AHTD is currently conducting a review of the application pertaining to required street improvements.
Z File Number Z-8878
Southern Star Concrete Inc. Long -form PD-I 16101 Alexander Rd.
1 Alexander Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline will be required.
2 Preliminary review shows a substantial area of the site lies within the regulated floodway and
floodplain of Crooked Creek. Per City Code 36.141(h)(2)d, floodway encroachments including fences,
structures, open storage of materials, equipment, fill, vehicle parking, and other impediments are
prohibited. Provide dates when the concrete plant, building, diesel tank, and storage areas were
erected or installed?
3 Per City Code, 36-341(f) in the floodplain and floodway, the storage or processing, aboveground and
storage belowground of materials or fuel which is flammable or explosive shall be unlawful.
4 In accordance with Section 31-176, floodway areas must be shown as floodway easements or be
dedicated to the public. In addition, a 25 foot wide access easement is required adjacent to the
floodway boundary.
5 Provide a property survey with existing topographic information at maximum five-foot contour
interval. Show the limits of the 100-year floodway and floodplain.
Z File Number Z-8879
Epperson Short -form PD-R 321 N. Spruce
1 Public alleys in the rear is not maintained by City of Little Rock.
Monday, July 29, 2013 Page 8 of 8
PLANNING COMMISSION REVIEW
CENTRAL ARKANSAS WATER
26 July 2013
NAME
MACAURTHER COMMONS PCD;
400 BLOCK OF CAPITOL AVE
TYPEISSUE
COMMENTS
PC Z-1718-A All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
NAME
TYPEISSUE
TL ADDTN, PRD, TAYLOR LOOP PRD Z-8194-A
RD NORTH OF HINSON
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
2
NAME TYPE ISSUE COMMENTS
3. MASSEY; PCD, EAST SIDE OF PCD Z-8833-A All Central Arkansas Water requirements in
HWY 300, NORTH OF CHENAL effect at the time of request for water service
PINWY must be met.
A water main extension will be needed to
provide water service to this property.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
3
NAME TYPE ISSUE COMMENTS
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
4
NAME
TYPE ISSUE COMMENTS
4. RIVERDALE ADD REPLAT SITE PLAN S-57-YY
TRACTS D-2A-R, E-2-R2 & R-O-W
ABANDONMENT FOR
BROOKWOOD DR; EAST SIDE
OF RIVERFRONT AT CEDAR
HILL RD
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
5
NAME
5. LOT 3 COL. GLENN BUSINESS
CENTER; PCD, SE CORNER OF
COLONEL GLENN &
SHACKLEFORD
TYPE ISSUE
PCD Z-5703-D
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system. THERE IS AN ADDITIONAL CIC-
MAIN CHARGE ASSOCTIATED WITHT
THE WATER MAIN IN SHACKLEFORD.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
M
NAME
6. TAYLOR PARK LOT 57A-57C,
REVISED POD; SWC TAYLOR
PARK & KANIS
TYPEISSUE
POD Z-7875-D
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
7
NAWIt
KINNAMAN AUTO REPAIR CUP
15617 CHENAL PARKWAY
TYPE ISSUE
PCD Z-7622-C
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
NAME
TYPE ISSUE COMMENTS
WEST PULASKI VOLUNTEER PRELIM S-1706
FIRE STATION, DIST. 23 PRELIM.
PLAT LOT 1 PINNACLE VALLEY
STATION; NORTH OF 8501
PINNACLE VALLEY RD
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
0
N
NAME TYPE ISSUE COMMENTS
EPPERSON PD-R, 321 N. PD-R Z-8879 All Central Arkansas Water requirements in
SPRUCE ST. effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
10
NAME
10. SOUTHERN STAR CONCRETE,
PDI, 16101 ALEXANDER RD
TYPE ISSUE COMMENTS
PDI Z-8878 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
11
NAME TYPE ISSUE
11. OUT IN THE WOODS PD-R Z-2582-A
APARTMENTS, PD-R, 9201
KANIS RD
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
12
NAME
TYPE ISSUE COMMENTS
12. ROCK CITY MARINA & YACHT PCD Z-7919-D All Central Arkansas Water requirements in
CLUB / NE OF 3RD & BOND effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
Please submit plans for water facilities to
Central Arkansas Water for review. Plan
revisions may be required after additional
review. Contact Central Arkansas Water
regarding procedures for installation of water
facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department
of Health Engineering Division and Little
Rock Fire Department is required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
Additional fire hydrant(s) will be required.
Contact the Little Rock Fire Department to
obtain information regarding the required
placement of the hydrant(s) and contact
Central Arkansas Water regarding
procedures for installation of the hydrant(s).
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
13
®� o
THIS
SITE h3
i�
!1
a
AF
cp ;9
Area Zoning
Case: S-1706 N
Location: Immediately North of 8501
Pinnacle Valley RD
Ward: 0
PD: 1 0 125250 500 Feet
CT: 42.05
TRS: T2N R13W7
a
S
ry
w
cp
_O
0o
Lu
v f
w CD
0
w
Y
n
CL
C`0004ronnur i.... .._.
N88°19'0
HATCH
POINT OF
BEGINNING
CD I
�:t;d
1�3-,
N
Lu , cv
�I
0
0
r
O
Z
I
J
E
N89024'38"W 219.39'
HATCHER ENTERPRISES, INC
43R0070000106 ZONED C-1
7
I �
co
c7i
N
CALCULATED POINT IN
BECK ROAD
S-1706 IMMEDIATELY NORTH OF PRELIMINARY PLAT
8501 PINNACLE VALLEY RD
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 Subdivision
August 23, 2013
Thomas Engineering
Thomas Pownall
3810 Lookout Road
North Little Rock, AR 72116
Re: West Pulaski Volunteer Fire Station District 23 Preliminary Plat — Lot
1 Pinnacle Valley Station (S-1706), located immediately North of
8501 Pinnacle Valley Road (Northeast corner of Pinnacle Valley
Road).
Dear Sirs:
This is to advise you that in connection with your request concerning the above
referenced file number the following action was taken by the Planning
Commission at its meeting on August 22, 2013:
X Approved with conditions.
Recommended approval with conditions.
Recommended approval as submitted.
Denied your request as submitted.
Deferred to the Meeting.
Other:
If you have any questions concerning any other matter please do not hesitate to
contact me at 371=6821.
Respectfully,
Donna James, AICP
Subdivision Administrator
A
Et
City of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
DATE: July 15, 2013
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
1 I-U.
Zoning and
Subdivision
NAME: West Pulaski Volunteer Fire Station, District 23
Preliminary Plat — Lot 1 Pinnacle Valley Station
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1706
LOCATION: Immediately north of 8501 Pinnacle Valley Road
(northeast corner of Pinnacle Valley)
Litt e Roc Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On August 22, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on July 26, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on August 1, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
M",
Donna James, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY July 29, 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
ice{- , r �r__ w /TW P ROL 22 `l' 1
By: 7
Enclosure
Et
City of Little Rock , .
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 Subdivision
DATE: July 15, 2013
❑
Entergy (2)
❑
Center Point - ARKLA
❑
AT&T(2)
❑
Central Arkansas Water
❑
Little Rock Wastewater
❑
Pulaski County Planning
e-ffoo
Little Rock Fire Department
NAME: West Pulaski Volunteer Fire Station, District 23
Preliminary Plat — Lot 1 Pinnacle Valley Station
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1706
LOCATION: Immediately north of 8501 Pinnacle Valley Road
(northeast corner of Pinnacle Valley)
❑ Public Works: Engineering, Traffic (2)
❑ Parks and Recreation Department
❑ Planning and Development — Site Plan Review
❑ Planning and Development Graphics
❑ CATA
TO WHO IT MAY CONCERN:
On August 22, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on July 26, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on August 1, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
M",
Donna James, AICP
Subdivision Administrator
(Please respoop below and return this letter with your comments for our records.)
Approved as Submitted.
*To all
PLEASE RETURN COMMENTS BY July 29, 2013.
Easement (s) required (See attached plat or description.)
utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for
easement or the request will not be included in the Planning Commission agenda.
Comments-
By:
Enclosure
/� &i
the
Et
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6663 Subdivision
DATE: July 15, 2013
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
NAME: West Pulaski Volunteer Fire Station, District 23
Preliminary Plat — Lot 1 Pinnacle Valley Station
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1706
LOCATION: Immediately north of 8501 Pinnacle Valley Road
(northeast corner of Pinnacle Valley)
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On August 22, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on July 26, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on August 1, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Donna James, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY July 29, 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
Et
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6663
DATE: July 15, 2013
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
NAME: West Pulaski Volunteer Fire Station, District 23
Preliminary Plat — Lot 1 Pinnacle Valley Station
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1706
LOCATION: Immediately north of 8501 Pinnacle Valley Road
(northeast corner of Pinnacle Valley)
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On August 22, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on July 26, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on August 1, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
M",
Donna James, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY July 29, 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
By:
Enclosure
� M
subd.doc 03/01/10
NOTICE OF PUBLIC HEARING
BEFORE
THE LITTLE ROCK PLANNING COMMISSION
ON AN APPLICATION TO
SUBDIVIDE PROPERTY
To ALL owners of land lying adjacent to (including across the street from) the boundary of the property
located at:
SO(, F FF-f- o is, T[4 OF F- rArAAc ts_ N ANUS-11 eoA,0 AW b G6QL lzo A Q
(GENERAL LOCATION OF PROPERTY ON WHICH IS PROPOSED TO BE SUBDIVIDED)
No 1'NQDF-E55 (yid Nta�N11 bt= E3561 ViM4ACy \LQLLa—`_2 2D40
(ADDRESS OF PROPERTY TO BE SUBDIVIDED, IF AVAILABLE)
Owned by: l,0TGW-f?, f f EM(L.15t 5 , T i4 G.
(NAME OF OWNER)
F0 ! C7 350!� . 1:111-kf— Ybct-1 i4 32263
(ADDRESS OF OWNER)
Number of proposed lots: I ; Proposed use of property: WfS i (W4>1Gl 140WOWI- t. r-� rtF PEVnrLstweTT
NOTICE IS HEREBY GIVEN THAT an application for the subdivision of the property cited above has
been filed with the Department of Planning and Development. A public hearing to review a preliminary
plat for this property will be held by the Little Rock Planning Commission on A%J&1t15F 27rao
7-0l3 , at�'C>0 P.M. in the Board of Directors Chamber, second floor, Little Rock City Hall,
located at 500 W. Markham Street.
Note: The platting into lots and streets may involve a request for variances or waivers from the
standards set forth in the Subdivision Regulations of the City of Little Rock.
ALL PARTIES IN INTEREST MAY APPEAR and be heard at the above cited time and place, or any
party in interest may notify the Planning Commission of their views on this matter by letter. All persons
interested in this request are invited to call or visit the Department of Planning and Development,
located at 723 W. Markham St., phone, 371-4790, to review and discuss the application information
with the Planning staff. Correspondence to the Planning Commission may be addressed to the
Commission as a whole or to individual Commission members in care of the Little Rock Department of
Planning and Development, 723 W. Markham St., Little Rock, AR 72201.
AFFIDAVIT
I hereby certify that i have notified all the abutting property owners of record of the above property that
subject property is being considered for subdivision and that a Public Hearing is to be held by the Little
Rock Planning Commission at the time and place described above.
Applicant (Owner or Authorized Agent) [ NM0,5 P— F�oki-�".
(Name) , ' 24
(Date)
CASH RECEIPT
Received From
Amount fWriffen Our) Amount (In Numbers)
-) _ k ,
/100 Dollars $
Purpose
By (Signature_gqd Tiftej
PS Form 1096, Noven4bor 1987 GPO 1993 0 — 348-;-016
'n
a-
TTf;�r RGECK: AW. 12223 rj —7 1 1-11 —7-tw
�11 PostiG %$-
go $ W". 4f`e J. 6 r— Postage
-U Codified Foo ru calliffecl reo
'lj
Pru 0 iviark
ZI Ftolurn Rmaipt Fee ostrriark Post
1:3 %torn lleceil)i T,'4,e
(Endo=nlont Aoqtdrod) Here Cl (Endomeplant Required) 2. 5
rJos*icled Dollvaty Fee C3 Fleslfir.W DeWary Fne
(Eildonavent fletluired) ilo. 00 C3 (I-nd()M3M(:nt Roqtdred)
-I-
j3 Total Posiace & Fees :9 $6'. .-D
r-9
1, A NELSON,
ru NELSONO NELSON, H NELSON, N READY, R
WATERS, M NELSON, B GAMBLE, E
MICHAEL AND RUBY NELSON r-q
C:I NELSON, B TYLER AND R DUNN
8701 PINNACLE VALLEY ROAD F- 1171 HIGHWAY 305 S
LITTLE ROCK, AR 72223 SEARCY, AR 72143
-n
n R."'J'a i f-,' 7 2'-) 2 3 J-1 RIC'kl i'fl'l 72'20"3
1,01. 46 0 116 -9 -0:1
_n Potntage $
Certirlod Fee 3 1 0- ceffilied Fee $3.110 0-5
5 Postmark Postmark
ZI 13 -?1(jrn Receipt Fee Mere Z3 rit%jr1l flec6l)t Foo Hore
c•Ot
(Endorsenioni ReqtjirwJ) Z3 (Undorsonloot 140qL1ifP.d)
Iles(ocind Delivery Foo 'on
(Endorsoillew Re(Ilwaid) d
"lotdont' 10(wire, D01
:3 'Iblal Poster -go & 17008 $ %Tolal Posta(w F. tees
M
.0 A NELSON, 0 NELSON, H NELSON, N READY, R ru
-9 • NELSON, M WATERS, M NELSON, 8 GAMBLE, E --------------- r9 HATCHER ENTERPRISES, INC. ...............
-3 NELSON, B TYLER AND R DUNN P.O. BOX 3505
......... . .................
8701 PINNACLE VALLEY ROAD LITTLE ROCK, AR 72203
LITTLE ROCK, AR 72223 OEM
PULASKI
COUNTY TITLE
12921 CANTRELL ROAD STE 401
LITTLE ROCK, ARKANSAS 72223
501-537-3700 FAX 501-537-3701
19 JULY, 2013
RE: PART OF THE WEST HALF OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER, SECTION 7, TOWNSHIP 2
NORTH, RANGE 13 WEST, PULASKI COUNTY, ARKANSAS, SAID PROPERTY BEING MORE PARTICULARLY DESCRIBED AS
FOLLOWS; COMMENCING AT THE SOUTHWEST CORNER OF SAID SOUTHWEST QUARTER OF THE NORTHEAST QUARTER,
THENCE NORTH 01 DEGREE 40 MINUTES 41 SECONDS EAST 248.40 FEET TO THE POINT OF BEGINNING; THENCE
CONTINUE NORTH 01 DEGREE 40 MINUTES 41 SECONDS EAST 180.67 FEET; THENCE SOUTH 88 DEGREES 19 MINUTES 00
SECONDS EAST 218.85 FEET; THENCE SOUTH 01 DEGRE•E 30 MINUTES 53 SECONDS WEST 176.48 FEET; THENCE NORTH 89
FELT 24 MINUTES 38 SECONDS WEST 219.39 FEET TO THE POINT OF BEGINNING.
THE FOLLOWING IS A LIST OF THE APPARENT PROPERTY
OWNERS LYING WITHIN 200 FEET OF THE ABOVE DESCRIBED LAND:
PART OF THE SE QUARTER OF THE NORTHWEST QUARTER OF SECTION 7, TOWNSHIP 2
NORTH, RANGE 13 WEST, PULASKI COUNTY ARKANSAS, BEING MORE PARTICULARLY
DESCRIBED AS FOLLOWS: BEGINNING 508.7 FEET SOUTH OF THE NORTHEAST CORNER OF
THE SOUTHEAST CORNER OF THE NORTHWEST QUARTER; THENCE SOUTH 2O8.7 FEET;
THENCE WEST 208.7 FEET; THENCE NORTH 2O8.7 FEET; THENCE EAST 208.7 FEET TO THE
POINT OF BEGINNING.
ALLAN M. NELSON AND SHERRIE D. NELSON
8700 PINNACLE VALLEY ROAD
LITTLE ROCK, AR 72223
PART OF THE WEST HALF OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER,
SECTION 7, TOWNSHIP 2 NORTH, RANGE 13 WEST, PULASKI COUNTY, ARKANSAS, MORE
PARTICULARLY DESCRIBED AS FOLLOWS: COMMENCE AT THE CENTER OF SAID SECTION
7; THENCE NORTH 00 DEGREES I 1 MINUTES WEST ALONG THE WEST LINE OF THE
SOUTHWEST QUARTER NORTHEAST QUARTER, 429.35 FEET TO THE POINT OF BEGINNING;
THENCE CONTINUE NORTH 00 DEGREES 11 MINUTES WEST ALONG THE WEST LINE OF THE
SOUTHWEST QUARTER NORTHEAST QUARTER, 190,65 FEET; THENCE NORTH 89 DEGREES
49 MINUTES EAST 330.0 FEET; THENCE SOUTH 00 DEGREES I I MINUTES EAST 190,65 FEET;
THENCE SOUTH 89 DEGREES 49 MINUTES WEST 330.0 FEET TO THE POINT OF BEGINNING.
AND
PART OF THE SOUTHWEST QUARTER OF TIIE NORTHEAST QUARTER, SECTION 7,
TOWNSHIP 2 NORTH, RANGE 13 WEST, PULASKI COUNTY, ARKANSAS, MORE
PARTICULARLY DESCRIBED AS FOLLOWS: BEGINNING AT A POINT 752 FEET NORTH OF
THE SOUTHWEST CORNER OF SAID SSW 1/4 NE 114; SAID POINT BEING THE SOUTHWEST
CORNER OF LANDS CONVEYED TO TOMMIE READY AND WIFE BY DEED OF RECORD IN
BOOK 1205 AT PAGE 401; THENCE EAST ALONG THE SOUTH LINE OF SAID READY LANDS
330 FEET TO THE SOUTHEAST CORNER OF SAID READY LANDS; THENCE RUN SOUTH 132
FEET; THENCE RUN WEST, PARALLEL TO THE SOUTH LINE OF THE READY LANDS, 330
FEET; THENCE NORTH 132 FEET TO THE POINT OF BEGINNING.
MICHAEL NELSON AND RUBY NELSON.
8.701 PINNACLE VALLEY ROAD'
LITTLE ROCK, AR 72223
PART OF THE SOUTHEAST QUARTER OF THE NORTHWEST QUARTER AND PART OF THE
SOUTHWEST QUARTER OF THE NORTHWEST QUARTER, SECTION 7, TOWNSHIP 2 NORTH,
RANGE 13 WEST, PULASKI COUNTY, ARKANSAS.
ALLAN M. NELSON, OZELL L. NELSON, HENRY L. NELSON, NORMA J. READY, RAY W.
NELSON, MAXINE WATERS, MICHAEL O. NELSON, BENNIE L. GAMBLE, EDDIE J. '
NELSON, BARBARA A. TYLERj ABD ROSE M. DUNN
1171 HIGHWAY 305 S
SEARCY, AR 72143
87.01 PINNACLE VALLEY ROAD
LITTLE ROCK, AR 72223
PART OF THE WEST 1/2 SWI/4 NE1/4, SECTION 7, TOWNSHIP 2 NORTH, RANGE 13 WEST,
PULASKI COUNTY, ARKANSAS, MORE PARTICULARLY DESCRIBED AS FOLLOW:
COMMENCE AT THE CENTER OF SAID SECTION 7; 89 DEGREES 23 MINUTES EAST ALONG
THE SOUTH LINE OF THE SWIA NE 1/4, SAID SECTION 7, 330.0 FEET TO THE POINT OF
BEGINNING; THENCE NORTH 00 DEGREES I 1 MINUTES WEST 879.69 FEET; THENCE NORTH
89 DEGREES 49 MINUTES EAST 326.9 FEET; THENCE SOUTH 876A FEET TO THE SOUTH LINE
OF SAID SWIM NEIA; THENCE SOUTH 89 DEGREES 23 MINUTES WEST ALONG SAID SOUTH
LINE, 324.E FEET TO THE POINT OF BEGINNING,
AND
PART OF THE S W 1/4 AND PART OF THE S W 1 /4 OF THE N W I /4, SECTION 7, TOWNSHIP 1
NORTH, RANGE 13 WEST, PULAS�l COUNTY, ARKANSAS.
HATCHER ENTERPRISES, INC.
P.O. BOX 350S
LITTLE ROCK, AR 72203 b
CERTIFIED THIS THE 9" DAY OF JULY, 2013 @ 6:00 A.M.
THIS IS A LIMITED SEARCH OF THE RECORDS AND IS NOT TO BE CONSTRUED AS A
TITLE INSURANCE POLICY, LEGAL OPINION OR COMMITMENT TO INSURE. LIABILITY IS
LIMITED TO THE AMOUNT CHARGED FOR THIS SEARCH.
SINCERELY,
r r
G. LETZI f r�
RTA #41
EtCity of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
DATE: July 16, 2013
TO: River Valley POA
ATTENTION: Louis Bianco
ADDRESS: 8108 Pinnacle Valley Road
Little Rock AR 72223
REQUEST: West Pulaski Volunteer Fire Station District 23 Preliminary Plat (S-1706h
a request for a one 1 lot plat containing 0.898 acres. The lot is being created from an
area containing 10+ acres. The lot is proposed for development with a Volunteer Fire
Station
GENERAL LOCATION OR ADDRESS: located immediately North of 8501 Pinnacle
Valley Road (Northeast corner of Pinnacle Valle
OWNED BY/APPLICANT: Hatcher enterprises, Inc. Greg Hatcher Owner -- Use by the
West Pulaski Volunteer Fire ❑e artment Fire Station #23
NOTICE IS HEREBY GIVEN THAT an application for a Prelimina Plat of the above
property has been filed with the Department of Planning and Development. A public
hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on August 22,
2013 at 4:00 P.M. This notice is provided in order to assure that neighborhood
associations are aware of issues that may affect their neighborhood. Information
requests should be directed to the Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
3810 LOOKOUT RD
July 12, 2013
THOMAS ENGINEERING COMPANY
civil engineers land surveyors
NORTH LITTLE ROCK, AR 72116
Ms. Donna James
Subdivision Administrator
City of Little Rock Planning and Development
723 West Markham
Little Rock, AR 72201
RE: West Pulaski Volunteer Fire Station, District 23
Preliminary Plat Application
Dear Ms. James:
(501)753-4463 FAX (501)753-6814
Please let this letter serve as our application for a preliminary plat of the West Pulaski Volunteer Fire
Station on Pinnacle Valley Road. We would like to be on the August 22t", 2013 Planning Commission
agenda. The property is zoned R-2 and located 300 feet north of Pinnacle Valley Road and Beck Road.
This project is currently under review by the Little Rock Planning Commission for a Conditional Use.
If you have any questions, please let me know.
Sincerely,
I
Thomas R. Pownall, P.E.
Project Engineer
PLAT AND BILL OF ASSURANCE
Of
Lot 1, WEST PULASKI FIRE ADDITION
In the City of Little Rock, Pulaski County, Arkansas
HATCHER ENTERPRISES, INC. to the Public
KNOW ALL MEN BY THESE PRESENTS:
That HATCHER ENTERPRISES, INC., ("Grantor"), being the owner of a certain tract of
land described as:
PART OF THE WEST HALF OF THE SOUTHWEST QUARTER OF THE NORTHEAST QUARTER,
SECTION 7, TOWNSHIP 2 NORTH, RANGE 13 WEST, PULASKI COUNTY, ARKANSAS. SAID
PROPERTY BEING MORE PARTICULARLY DESCRIBED AS FOLLOWS:
COMMENCING AT THE SOUTHWEST CORNER OF SAID SOUTHWEST QUARTER OF THE
NORTHEAST QUARTER, THENCE N 01° 40' 4 1 " E FOR 248.40 FEET TO THE POINT OF BEGINNING;
THENCE CONTINUE N 010 40' 4 1 " E FOR 180.67 FEET;
THENCE S 880 19' 00" E FOR 218.85 FEET;
THENCE S 010 30' 53" W FOR 176.48 FEET;
THENCE N 890 24' 38" W FOR 219.39 FEET TO THE POINT OF BEGINNING. SAID PROPERTY
CONTAINS 0.898 ACRES, MORE OR LESS
hereby plats the above described land as Lot 1, WEST PULASKI FIRE ADDITION in the
City of Little Rock, Pulaski County, Arkansas, as shown and represented on the attached
plat and henceforth description and conveyance by such designation or part thereof, as
shown and represented on said attached plat, shall be a proper and sufficient description
thereof.
Permanent easements for drainage, for laying and maintaining sewer pipes and mains and
for the installation and maintenance of utilities are created and reserved over, across and
through said lands as shown on attached plat.
Any business, trade, activity or undertaking not in keeping with the zoning use of said land,
herein platted, and each of them, is prohibited and shall not be carried on or permitted on
any part of said land; and, anything deemed a nuisance or to create undue annoyances or
which interferes with the zoning use and occupancy of said land shall be prohibited thereon.
Invalidation of any covenant, restriction, requirement of provision set forth herein or any
part thereof by an order, judgment or decree of any Court or otherwise shall not invalidate
or affect any of the other covenants and/or restrictions or any part thereof as set forth herein
but they shall remain in full force and effect.
The covenants, restrictions, requirements and provisions of this instrument shall be
automatically extended for successive periods of ten years each on and after January 1,
2025, unless and unto amended or canceled as authorized herein.
EXECUTED this the day of .2013.
HATCHER ENTERPRISES, INC.
GREG HATCHER
STATE OF ARKANSAS )
COUNTY OF PULASKI )
On this day before me, a Notary Public within and for the above County and State, duly
commissioned, qualified and acting, appeared GREG HATCHER, owner of HATCHER
ENTERPRISES, INC., to me well known and declaring to be authorized in his capacity to
execute the foregoing instrument, and further stated and acknowledged that he had so
signed, executed and delivered the said instrument for the consideration, uses, and purposes
therein set forth.
WITNESS my hand and official seal this the day of 2013.
My commission expires
City of Little Rock
Planning and Development