HomeMy WebLinkAboutS-1705 ApplicationPublic Works Review Comments
Planning Commission
Agenda Date: 7-11-13
Z File Number 7-8872
501 Main Street PCD
Board of Adjustment
510 Main St
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Z File Number 5-1704
Woodcreek Add. Pre Plat
8800 Block of Mabelvale Cut-off
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 Driveway spacing of 300 ft between driveways and 150 from side property lines is required on a
minor arterial street (Mabelvale Cut-off). Show the proposed location of driveways.
3 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
5 Provide a letter prepared by a registered engineer certifying the sight distance at the proposed
driveway(s) comply with 2004 AASHTO Green Book standards.
Z File Number S-1705
Haw Branch Add. Pre. Plat
13805 Crystal Valley Road
1 Crystal Valley Road is classified on the Master Street Plan as a collector street. A dedication of
right-of-way 30 feet from centerline will be required.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Crystal Valley Road including 5-foot sidewalks with planned
3 Show proposed driveway location(s).
4 Contact Pulaski County Planning Department for conditions for developing property in the floodplain.
5 The minimum Finished Floor elevation of at least 1 ft above the base flood elevation is required to be
shown on plat and grading plans.
6 Provide a letter prepared by a registered engineer certifying the sight distance at the propsoed
driveway(s) comply with 2004 AASHTO Green Book standards.
Z File Number S-220-C
Michael Cove Add Lot 1 Replat
Kanis Rd & Michael Drive
1 Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way
45 feet from centerline will be required.
Tuesday, June 11, 2013 Page I of 4
2 A 20 feet radial dedication of right-of-way is required at the intersection of Kanis Rd and Michael
Drive.
3 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Kanis Road including 5-foot sidewalks with planned development.
The new back of curb should be located 29.5 ft from centerline.
4 Sidewalks with appropriate handicap ramps are required to be installed adjacent to Michael Drive in
accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan.
5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
6 Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain
barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501) 379-
1805 (Travis Herbner).
7 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
8 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
9 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
10 Street Improvement plans shall include signage and striping. Traffic Engineering must approve
completed plans prior to construction.
11 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
12 Driveway locations and widths must meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The driveway spacing on Kanis Road is 300 ft between driveways and 150 ft from
property lines. The driveway spacing on Michael Drive is 250 ft between driveways and 125 ft from
property lines. Show the proposed driveway locations
13 Provide a letter prepared by a registered engineer certifying the sight distance at the proposed
intersections and driveways comply with 2004 AASHTO Green Book standards.
Z File Number 5-590-F
EZ Mart Store #607 Site Plan Review 11911 Mara Lynn Road
1 Bowman Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline will be required.
2 A 20 feet radial dedication of right-of-way is required at the intersection of Bowman Road and Mara
Lynn Road.
3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
4 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private
improvements located in the right-of-way.
Tuesday, June 11, 2013 Page 2 of 4
Z File Number S-720-A
EZ Mart Store #611 Site Plan Review 11724 Rainwood Road
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Z File Number Z-4451-E
Hunters Green Rev PD-R
75 Hunters Green Circle
1 Prior to construction of retaining walls 4 ft or taller, a engineer's certification of design and plans must
be submitted to Public Works for approval. After construction, an as -built certification is required
for construction of the retaining wall.
Z File Number Z-7895-B
7th & Woodrow Rev PCD
712 - 724 Appian Way St
1 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Appian Way Street including 5-foot sidewalks with planned
development. The new back of curb should be 15.5 ft from centerline.
2 Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain
barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501) 379-
1805 (Travis Herbner).
3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
4 Storm water detention will not apply to the proposed development.
5 A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to
construction.
6 The minimum Finish Floor elevation of at least 1 foot above the base flood elevation is required to
be shown on plat and grading plans.
7 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
8 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. On commercial streets, spacing between driveways is 250 ft and 125 ft from side
property lines. Variances must be requested for the driveway locations.
9 A land alteration variance must be requested for slopes steeper than 3:1.
Z File Number Z-8869
Pearl Management PD-R
0 No comments
Z File Number Z-8870
Haskins PD-R
0 No comments
324 S. Schiller St
4001 N Lookout Street
Tuesday, June 11, 2013 Page 3 of 4
t
Z File Number Z-8871
315 Main Street PCD 315 Main Street
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 The proposed patio has been approved by the Board of Adjustments with conditions. Staff is
currently processing a franchise permit for the patio. The drawing attached to the application does not
show the approved patio setbacks.
Z File Number Z-8873
201 - 205 Capitol Ave PCD 201 - 205 Capitol Ave
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Tuesday, June 11, 2013 Page 4 of
Little Rock Wastewater Comments
Project Number S-1704
Project Name Project Type
Woodcreek Addition Preliminary Plat
Project Number S-1705
Project Name
Project Type
Haw Branch Addition
Preliminary Plat
Project Number S-220-C
Project Name
Project Type
Replat of Lot 1 Michael
Revised Plat
Cove Addition Tracts 8 & 9
Hopson and Sach's
Project Number S-590-F
Project Name
Project Type
EZ Mart Store #607
Subdivision Site Plan Review
Project Number S-720-A
Project Name
Project Type
EZ Mart Store #611
Subdivision Site Plan Review
Project Number Z-4451-E
Project Name
Project Type
Hunters Green Revised PD-
Planned Residential Development
R
Project Number Z-7895-B
Project Name Project Type
7th & Woodrow Planned Commercial Development
Project Number Z-8869
Project Name Project Type
Pearl Management Planned Residential Development
Comment Made
Sewer main extension required with easements for this
project.
Comment Made
Outside Service Boundary, no comment.
Comment Made
Sewer available to this project. Sewer located on lot for
Lots 3 & 4. Sewer Service for Lot 1 & 2 is located on
north side of Kanis Road.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project. Builder should verify
sewer main location prior to construction. Sewer main
is close to building footprint.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project.
Thursday, June 06, 2013 Page 1 of 2
Project Number Z-8870
Project Name
Project Type
Comment Made
Haskins
Planned Residential Development
Sewer available to this project.
Project Number Z-8871
Project Name
Project Type
Comment Made
315 Main Street
Planned Commercial Development
Sewer available to this project. Capacity Contribution
Fee Calculation Required. Contact LRW for details.
Project Number Z8872
Project Name
Project Type
Comment Made
510 Main Street
Planned Commercial Development
Sewer available to this project.
Project Number Z-8873
Project Name
Project Type
Comment Made
201-205 W Capitol Avenue
Planned Commercial Development
Sewer available to this project. Capacity Contribution
Fee Calculation Required. Contact LRW for details.
Thursday, June 06, 2013 Page 2 of 2
M
1
PLANNING COMMISSION REVIEW
CENTRAL ARKANSAS WATER
20 June 2013
NAME TYPEISSUE
HAW BRANCH ADDTN; PRELIM S-1705
PLAT, 13805 CRYSTAL VALLEY
RD
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
Contact'Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. The
additional Capital Investment Charge is
applicable to all connections off the waterline
along Crystal Valley Rd at this location.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
1
NAME TYPE ISSUE
COMMENTS
2. WOODCREEK ADDTN; PRELIM S-1704
All Central Arkansas Water requirements in
PLAT, 8800 MABELVALE CUT-
effect at the time of request for water service
OFF
must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
VA
NAME
TYPEISSUE
3. REPLAT OF LOT 1 MICHAEL S-220-C
COVE ADDTN TRACTS 8 & 9
HOPSON & SACHS; SW
CORNER OF KANIS & MICHAEL
DR
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
3
NAME
4. EZ MART STORE #607 SUDB.
SITE PLAN, 11911 MARA LYNN
RD
TYPE ISSUE
S-590-F
COMMENTS
NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
4
5.
NAME
EZ MART STORE #611 SUDB.
SITE PLAN, 11724 RAINWOOD
RD
TYPEISSUE
S-720-A
COMMENTS
NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
5
NAME TYPE ISSUE COMMENTS
6. 7TH & WOODROW PCD; 712-724 PCD Z-7895-B All Central Arkansas Water requirements in
APPIANWAY effect at the time of request for water service
must be met.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developers expense. IF REQUIRED "THEN
A WATER MAIN EXTENSION WILL BE
NEEDED TO PROVIDE WATER SERVICE
TO THIS PROPERTY.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backfiow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backfiow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
7
3
NAME TYPE ISSUE COMMENTS
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
HUNTERS GREEN REVISED PD- PRD Z-4451-E No objection. All Central Arkansas Water
R; 75 HUNTERS GREEN CIR requirements in effect at the time of request
for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
201-205 CAPITOL AVE,, PC PCD Z-8873 NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
0
10
NAME TYPE ISSUE COMMENTS
510 MAIN ST, PCD PCD Z-8872 NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
324 S. SCHILLER ST., PR-D 2ND PRD Z-8869 No objection. All Central Arkansas Water
LIVING QUARTERS requirements in effect at the time of request
for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
NAME TYPE ISSUE COMMENTS
11. 4001 N. LOOKOUT ST, HASKINS PRD Z-8870 No objection. All Central Arkansas Water
SHORT FORM requirements in effect at the time of request
for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
12. 315 MAIN ST, PCD
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
PCD Z-8871 NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
9
Public Works Review Comments
Planning Commission
Agenda Date: 7-11-13
Z File Number 7-8872
501 Main Street PCD
Board of Adjustment
510 Main St
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Z File Number 5-1704
Woodcreek Add. Pre Plat
8800 Block of Mabelvale Cut-off
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 Driveway spacing of 300 ft between driveways and 150 from side property lines is required on a
minor arterial street (Mabelvale Cut-off). Show the proposed location of driveways.
3 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
4 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
5 Provide a letter prepared by a registered engineer certifying the sight distance at the proposed
driveway(s) comply with 2004 AASHTO Green Book standards.
Z File Number S-1705
Haw Branch Add. Pre. Plat
13805 Crystal Valley Road
1 Crystal Valley Road is classified on the Master Street Plan as a collector street. A dedication of
right-of-way 30 feet from centerline will be required.
2 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Crystal Valley Road including 5-foot sidewalks with planned
3 Show proposed driveway location(s).
4 Contact Pulaski County Planning Department for conditions for developing property in the floodplain.
5 The minimum Finished Floor elevation of at least 1 ft above the base flood elevation is required to be
shown on plat and grading plans.
6 Provide a letter prepared by a registered engineer certifying the sight distance at the propsoed
driveway(s) comply with 2004 AASHTO Green Book standards.
Z File Number S-220-C
Michael Cove Add Lot 1 Replat
Kanis Rd & Michael Drive
I Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way
45 feet from centerline will be required.
Tuesday, June 11, 2013 Page I of
2 A 20 feet radial dedication of right-of-way is required at the intersection of Kanis Rd and Michael
Drive.
3 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Kanis Road including 5-foot sidewalks with planned development.
The new back of curb should be located 29.5 ft from centerline.
4 Sidewalks with appropriate handicap ramps are required to be installed adjacent to Michael Drive in
accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan.
5 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
6 Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain
barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501) 379-
1805 (Travis Herbner).
7 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
8 Storm water detention ordinance applies to this property. Show the proposed location for stormwater
detention facilities on the plan.
9 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
10 Street Improvement plans shall include signage and striping. Traffic Engineering must approve
completed plans prior to construction.
11 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
12 Driveway locations and widths must meet the traffic access and circulation requirements of Sections
30-43 and 31-210. The driveway spacing on Kanis Road is 300 ft between driveways and 150 ft from
property lines. The driveway spacing on Michael Drive is 250 ft between driveways and 125 ft from
property lines. Show the proposed driveway locations
13 Provide a letter prepared by a registered engineer certifying the sight distance at the proposed
intersections and driveways comply with 2004 AASHTO Green Book standards.
Z File Number S-590-F
EZ Mart Store #607 Site Plan Review 11911 Mara Lynn Road
1 Bowman Road is classified on the Master Street Plan as a minor arterial. A dedication of right-of-
way 45 feet from centerline will be required.
2 A 20 feet radial dedication of right-of-way is required at the intersection of Bowman Road and Mara
Lynn Road.
3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
4 Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private
improvements located in the right-of-way.
Tuesday, June 11, 2013 Page 2 of 4
Z File Number 5-720-A
EZ Mart Store #611 Site Plan Review 11724 Rainwood Road
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Z File Number Z-4451-E
Hunters Green Rev PD-R
75 Hunters Green Circle
1 Prior to construction of retaining walls 4 ft or taller, a engineer's certification of design and plans must
be submitted to Public Works for approval. After construction, an as -built certification is required
for construction of the retaining wall.
Z File Number Z-7895-B
7th & Woodrow Rev PCD
712 - 724 Appian Way St
1 With site development, provide design of street conforming to the Master Street Plan. Construct
one-half street improvement to Appian Way Street including 5-foot sidewalks with planned
development. The new back of curb should be 15.5 ft from centerline.
2 Plans of all work in right-of-way shall be submitted for approval prior to start of work. Obtain
barricade permit prior to doing any work in the right-of-way from Traffic Engineering at (501) 379-
1805 (Travis Herbner).
3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction.
4 Storm water detention will not apply to the proposed development.
5 A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to
construction.
6 The minimum Finish Floor elevation of at least 1 foot above the base flood elevation is required to
be shown on plat and grading plans.
7 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic
Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic
Engr 379-1813 (Steve Philpott) for more info.
8 Driveway locations and widths do not meet the traffic access and circulation requirements of Sections
30-43 and 31-210. On commercial streets, spacing between driveways is 250 ft and 125 ft from side
property lines. Variances must be requested for the driveway locations.
9 A land alteration variance must be requested for slopes steeper than 3:1.
Z File Number Z-8869
Pearl Management PD-R
0 No comments
Z File Number Z-8870
Haskins PD-R
0 No comments
324 S. Schiller St
4001 N Lookout Street
Tuesday, June 11, 2013 Page 3 of 4
Z File Number Z-8871
315 Main Street PCD 315 Main Street
1 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
2 The proposed patio has been approved by the Board of Adjustments with conditions. Staff is
currently processing a franchise permit for the patio. The drawing attached to the application does not
show the approved patio setbacks.
Z File Number Z-8873
201 - 205 Capitol Ave PCD 201 - 205 Capitol Ave
I Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to
occupancy.
Tuesday, June 11, 2013 Page 4 of 4
"M
AF
CUP *MR
=L
.............
a ®� �3 ®® "-•—.'City Limits
o%.J me
AF I
I
® j
o .� I
AF 7:
U�
City Limits fig, I
I City Limits
EDIDp City Limits
.............. .
�06 _ia"��• �'4 °
® y .' City Limits wj a om
EIER
_ 1 fjC y Limits
City Limits `
PCD
1 This Q �T1 cer�Qaaraa�
Site��
CUP
Ell
SO' ®_
P
0
i
Area Zoning
Case- S-1705 N
Location: 13805 Crystal Valley RD
Ward: N/A
PD: 17
CT: 42.21
TRS: T1 N R13W32
)P\\
0 175350 700 Feet
310
310
Op�roximnle LOT 3
217a fioodwoy
N
N
n 100 yearood xflpiain
by elevation LOT 2
31.0
LOT
_ _ 1
9W CORNER, 5E 1/4, NW 1/4 310 N 88'52'58" W 1298.35 — —
SECi10N 32 T-1-N, R-13-W 13.75' ROW DEDICA710N
S-1705 013805 CRYSTAL VALLEY ROAD O PRELIMINARY PLAT
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
August 23, 2013
McGetrick Engineers
P.O. Box 30441
Little Rock, AR 72260
Re: Haw Branch Addition Preliminary Plat (S-1705), located at 13805
Crystal Valley Road
Dear Sirs:
This is to advise you that in connection with your request concerning the above
referenced file number the following action was taken by the Planning
Commission at its meeting on August 22, 2013:
Approved with conditions.
Recommended approval with conditions.
Recommended approval as submitted.
Denied your request as submitted.
Deferred to the Meeting.
X Other: Withdrew your request.
If you have any questions concerning any other matter please do not hesitate to
contact me at 371-6821.
Respectfully,
Donna James, AICP
Subdivision Administrator
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
July 15, 2013
McGetrick Engineers
P.O. Box 30441
Little Rock, AR 72260
Re: Haw Branch Addition Preliminary Plat (S-1705), located at 13805
Crystal Valley Road
Dear Sirs:
This is to advise you that in connection with your request concerning the above
referenced file number the following action was taken by the Planning
Commission at its meeting on July 11, 2013:
Approved with conditions.
Recommended approval with conditions.
Recommended approval as submitted.
Denied your request as submitted.
X Deferred to theAugust 22, 2013 Meeting.
Other:
If you have any questions concerning any other matter please do not hesitate to
contact me at 371-6821.
Respectfully,
Donna James, AICP
Subdivision Administrator
August 12, 2013
Ms. Donna James, Current Planning
Planning Department
Markham Street
City of Little Rock, 72201
Dear Ms. James,
Please remove without prejudice the Haw Branch Subdivision from the upcoming agenda for the
Planning Commission meeting.
Patrick M. McGetrick, P.E.
P.M.
James, Donna
From: MCGETRICK MCGETRICK <mcgetrick2@sbcglobal.net>
Sent: Wednesday, July 10, 2013 12:59 PM
To: James, Donna
Subject: HAW Branch
Donna,
We would like to request a six week deferral on HAW Branch preliminary plat. We are reviewing options
concerning the street improvements and the number of lots we would like to plat.
If you have any questions, just give me a call.
Pat
James, Donna
From: Jim Cranor <jcranor@co.pulaski.ar.us>
Sent: Friday, June 07, 2013 11:36 AM
To: James, Donna
Cc: Van McClendon
Subject: County Comments Haw Branch Addition Preliminary Plat
Donna,
Our comments below:
1.) Provide interior lot line bearings.
2.) Clarify with different I i nework/ hatched areas the limits of the Floodplain and floodway.
elevations for these areas. Provide relevant FEMA flood panel designation.
3.) Show state plane coordinates for two corners.
4.) Obtain flood development permit from Pulaski County Public Works for Lot #3.
5.) Provide Bill of Assurance.
6.) Obtain driveway permits for all three lots from Pulaski County Public Works.
Jim Cranor
Plans Review Coordinator
Pulaski County Planning and Development
3200 Brown Street
Little Rock, AR 72204
501-340-8265
Also provide base flood
EtCity of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
nLPt�0,'Mff) 371-4790 Fax: (501) 399-3435 or 371-6863
❑ Entergy (2)
❑ Center Point - ARKLA
❑ AT&T(2)
❑ Central Arkansas Water
❑ Little Rock Wastewater
❑ Pulaski County Planning
❑ Little Rock Fire Department
❑ Public Works: Engineering, Traffic (2)
❑ Parks and Recreation Department
NAME: Haw Branch Addition Preliminary Plat
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1705
LOCATION: located at 13805 Crystal Valley Road
❑ Planning and Development — Site Plan Review
❑ Planning and Development Graphics
❑ CATA
TO WHO IT MAY CONCERN:
On July 11, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on June 14, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on June 20, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Since ly,
)J%�(
Donna Jkoes, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted. PLEASE RETURN COMMENTS BY June 17, 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
By:
Enclosure
taCity of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
I1C r .(11) 371-4790 Fax: (501) 399-3435 or 371-6863
❑ Entergy (2)
❑ Center Point - ARKLA
❑ AT & T (2)
❑ Central Arkansas Water
❑ Little Rock Wastewater
❑ Pulaski County Planning
❑ Little Rock Fire Department
❑ Public Works: Engineering, Traffic (2)
❑ Parks and Recreation Department
NAME: Haw Branch Addition Preliminary Plat
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1705
LOCATION: located at 13805 Crystal Valley Road
❑ Planning and Development — Site Plan Review
❑ Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On July 11, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on June 14, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on June 20, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Since ly,
Donna J es, AICP
Subdivision Administrator
(Plea 7
and below and return this letter with your comments for our records.)
--Approved as.Submitted. PLEASE
RETURN COMMENTS BY June 17 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
oca rON is abduf r/z w•i`te, AM Fv- 11,4 i tw 47,3 bus' mkfe
By: _
Encf
tFCity of Little Rock `
Department of Planning and Development Planning
��" %723 West Markham Street Zoning and
Uttle Rock, Arkansas 72201-1334 Subdivision
"1) 371-4790 Fax: (501) 399-3435 or 371-6863
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
NAME: Haw Branch Addition Preliminary Plat
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1705
LOCATION: located at 13805 Crystal Valley Road
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On July 11, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on June 14, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on June 20, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Since ely,
Donna J es, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted. PLEASE RETURN COMMENTS BY June 17, 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
7-
By:
Enclosure
( CD & ce -) \ — `k' t �A
taCity of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
. nATTO (f 1) 371-4790 Fax: (501) 399-3435 or 371-6863
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning
Zoning and
Subdivision
NAME: Haw Branch Addition Preliminary Plat
TYPE OF ISSUE: Preliminary Plat
FILE NUMBER: S-1705
LOCATION: located at 13805 Crystal Valley Road
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On July 11, 2013 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on June 14, 2013.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on June 20, 2013.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Since ely,
Donna J es, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted. PLEASE RETURN COMMENTS BY June 17, 2013.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
I&rrz)
By: . �E?- M cr tl�
Enclosure
THE r . lur7ym� fwo*j
'4JH1(!r1 %V-v=71
APROfH,A-rE cE747M 6C -MC PWIFEFOY SPROZA
rgz-vl" . FIE-J-OC-17-noW eev� NO BF-
FzQv r Rim TD *, ROVE-
VSVE-L , F-5 .
TW L4 gc A5 'tfE Pft?o�-v
taCity of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
DATE: July 16 2013
TO: Southwest Little Rock United for Prowess
ATTENTION: Ms. Pat
ADDRESS: 8409 Dowan Drive
Little Rock, AR 72209
REQUEST: Haw Branch Addition Preliminary Plat S-1705 a request to allow the
subdivision of 9.78 acres into three 3 sin_qle-family residential lots. Each lot is
indicated with a minimum lot width of 50-feet adjacent to Crystal Valley Road. The
request includes a waiver of the re uired boundary street ordinance requirements to
C stal Valley Road.
GENERAL LOCATION OR ADDRESS: located at 13805 Crustal Valley Road
OWNED BY/APPLICANT: Douglas Woodall - Pat McGetrick of McGetrick
Engineer-s Agent Contact # 501-455-8899)
NOTICE IS HEREBY GIVEN THAT an application for a Preliminar Plat the above
property has been filed with the Department of Planning and Development. A public
hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on August 22,
2013 at 4:00 P.M. You were previously notified of this application request. This item
was deferred from the July 11, 2013, public hearing to this new hearing date. This
notice is provided in order to assure that neighborhood associations are aware of issues
that may affect their neighborhood. Information requests should be directed to the
Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
EtCity of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
DATE: July 16 2013
TO: Crystal Valley Neighborhood Association
ATTENTION:
Tom Brock
ADDRESS: 8207 Crystal Valley Cove
Little Rock AR 72210
REQUEST: Haw Branch Addition Prelimina Plat S-1705 a request to allow the
subdivision of 9.78 acres into three 3 single-family residential lots. Each lot is
indicated with a minimum lot width of 60-feet adjacent to C stal Valley Road. The
request includes a waiver of the required bounds street ordinance requirements to
Crystal Valley Road.
GENERAL LOCATION OR ADDRESS: located at 13805 Crystal Valley Road
OWNED BY/APPLICANT: Douglas Woodall - Pat McGetrick of McGetrick
Engineers Agent Contact # 501-455-8899
NOTICE IS HEREBY GIVEN THAT an application for a Preliminaly Plat the above
property has been filed with the Department of Planning and Development. A public
hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on August 22,
2013 at 4:00 P.M. You were previously notified of this application request. This item
was deferred from the July 11, 2013, public hearing to this new hearing date. This
notice is provided in order to assure that neighborhood associations are aware of issues
that may affect their neighborhood. Information requests should be directed to the
Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
Et
City of Little Rock
Department of Planning and Development
723 West Markham Street
little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
Planning
Zoning and
Subdivision
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT
OF LAND
DATE: June 7, 2013
TO: Southwest Little Rock United for Progress
ATTENTION: Ms. Pat Gee
ADDRESS: 8409 Dowan
Little Rock, AR 72209
REQUEST: Haw Ranch Addition Preliminary Plat (S -1705), a reggest_to allow the
subdivision of 9.78 acres into three 3 single-family residential lots. Each lot is
indicated with a minimum lot width of 60-feet adjacent to Crystal Valley Road.
GENERAL LOCATION OR ADDRESS: located at 13805 Crystal Valley Road
OWNED BY/APPLICANT: Dou las Woodall - Pat McGetrick of McGetrick
En ineers Agent Contact # 501-455-8899)
NOTICE IS HEREBY GIVEN THAT an application for a Preliminary Plat of the above
property has been filed with the Department of Planning and Development. A public
hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on July 11, 2013
at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are
aware of issues that may affect their neighborhood. Information requests should be
directed to the Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
City of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
Planning
Zoning and
Subdivision
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT
OF LAND
DATE: June 7, 2013
TO: Crystal Valley Neighborhood Association
ATTENTION
Tom Brock
ADDRESS: 8207 CKystal Valley Cove
ttle Rock. Ali 72210
REQUEST: Haw Ranch Addition Preliminary Plat S-1705 a r uest to allow the
subdivision of 9.78 acres into three 3 single-family residential lots. Each lot is
indicated with a minimum lot width of 60-feet adjacent to Crystal Valley Road.
GENERAL LOCATION OR ADDRESS: located at 13805 Cr stil Valley Road
OWNED BY/APPLICANT: Douglas Woodall - Pat McGetrick of McGetrick
Engineers Agent Contact # 501-455-8899
NOTICE IS HEREBY GIVEN THAT an application for a Preliminary Plat of the above
property has been filed with the Department of Planning and Development. A public
hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers; second floor, City Hall, 500 West Markham Street, on July 11, 2013
at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are
aware of issues that may affect their neighborhood. Information requests should be
directed to the Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
McGEMCK & McOEMICK
ENG/NEER5 - PLANNERS - SURVEYORS
June 4, 2013
Donna James, Subdivision Coordinator
Department of Planning and Development
723 West Markham Street
Little Rock, AR 72201
Re: Preliminary Plat Haw Branch Addition
Dear Ms. James:
We are herewith submitting the above captioned project for review. The project consists
of 10 acres located off Crystal Valley Road, currently zoned R-2.
The owners plan to develop a residential subdivision with three lots. The average lot size
is 2 to 5 acres. It will require no street improvements. The developer is Doug Woodall.
This property is outside but adjacent to the city limits of Little Rock. It will be annexed
if this project moves forward. We are asking for a variance of the street improvements to
Crystal Valley Road.
If you have any questions, or comments regarding this application, please advise us.
Sincerely,
McGetrick & McGetrick, Inc.
Patrick M. McGetrick, P.E.
P.O. Box 30441
Little Rock, Arkansas 72260
501-455-8899 fax 501-455-0525
subd.doc
03/01/10
INFORMATION SHEET FOR_
SUBDIVISION ZOG
OR SC]RD VISI6N S T7E� P AWN REVIEWS
ITEM NO. -7 DATE 6013j l o 1
FILE NO. c O
NAME: 0I4 Let U 6!� /G If �►+A';Al/TI A0•,
LOCAUON:-kVeJT Or= 42 "f r LE mL
DEVELOPER: ntl UG woOD L �-
STREET ADDRESS 9
CITY/STATE/ZIP 64.�Ao g4e �Ip
TELEPHONE NO. so/ _ 4 l3 ` aY34-
ENGINEER: MC-6 C rWla k At 0 is e -Tie IGi'
STREET ADDRESS /! *1 R S r►}GC G ®• r,F RP $4tLTQ Z 1 04a
CITY/STATE/ZIP At 7~� 99 ��i�.�Q � z t�
TELEPHONE NO. -674w -
AREA . -
FT. NEW STREET
ZONING ?-"L
NUMBER OF LOTS 3
PROPOSED USES %QR5 �Qev7"JN' 4-
PLANNING DISTRICT CENSUS TRACT
VARIANCES REQUESTED
i.) srRjFE7- w iDQ,vi.v e. o f cie ysr.4 v 4,4de y R a
2.)
3.)
4.)
subd.doc ` 03/01/10
DEPARTMENT OF NEIGHBORHOODS AND PLANNING
PRELIMINARY PLAT CHECKLIST (page one)
PROPOSED NAME OF SUBDIVISION: , B& & "R ve. /34 /`T 9D/ T%D AI
TYPE OF SUBDIVISION: L�Iii%/ DATE:
J
al a
a
a
w
7 p
�
a
�
w
O
❑
❑
El1.
Letter requesting preliminary plat approval.
❑
❑
El2.
Seventeen (18) copies of the preliminary plat.
❑
E3
❑
3. Filing fee.
❑
❑
lirl
❑
4. Notification completed. (Certified list of abutting property owners from abstract or title
company; notice form with affidavit executed; & proof of mailing of notice to all abutting
property owners furnished.)
THE FOLLOWING ARE REQUIRED PURSUANT TO SEC. 31-63 OF THE CODE OF ORDINANCES, -
Se
❑
❑
❑
5. Nameladdress of land owner with source of title. (Deed record book and page or instrument
number required).
❑
❑
❑
6. Name/address of subdivider.
❑
❑
❑
7. Linear feet of internal streets.
❑
❑
El
8. Average size of lots/Minimum lot size.
❑
❑
❑
9. Number of lots.
❑
❑
❑
10. Applicable existing covenants, and the proposed covenants on the land.
Rr
❑
❑
❑
11. Proposed open space.
B
❑
❑
❑
12. Proposed source of water supply.
V
❑
❑
❑
13. Proposed means of wastewater disposal.
0'
❑
❑
❑
14. Request for variances, waivers, or deferrals. (Completion of "Variance/Waiver Request Form"
required.)
FOLLOWING IS REQUIRED PURSUANT TO SEC. 31-88 OF THE CODE OF ORDINANCES:
❑ ❑ ❑ 16. Vicinity map, to scale. (Minimum scale to be 1:2000 feet; minimum area to be mile radius.)
THE FOLLOWING ARE REQUIRED PURSUANT TO SEC. 31-89 OF THE CODE OF ORDINANCES:
❑ ❑ ❑ 17. Preliminary plat drawing, to scale, with north point indicated.
(Maximum size for drawings: 24" x 36". Boundary lines are to be indicated by a heavy line.
Adjusted bearings and distances are to be shown, with ties to comers of record. Record bearings
and distances are to be shown, where applicable. Curve data is to include: radius, arc distance,
delta angle and chord bearing, and distances. Locations and physical descriptions of all
monuments -- indicating size, material, and type construction -- shall be shown.)
❑ ❑ ❑ 18. The date of survey.
❑ ❑ ❑ 19. Lot lines shown and dimensioned; streets, sidewalks, and easements shown;
(Names of streets and street widths must be shown.)
❑ ❑ ❑ 20. Front yard building setback lines shown on plat.
❑ ❑ ❑ 21. Contours shown at required intervals (2' intervals for grades less than 10%; 5' intervals for grades
above 10%).
❑ ❑ ❑ 22. Natural features shown (e.g.; drainage channels, bodies of water, wooded areas).
❑ ❑ ❑ 23. Cultural features shown.
(e.g.; streets, bridges, culverts, utility/power lines, pipelines, easements, parks, structures, city and
county lines, section lines).
❑ ❑ ❑ 24. Limits of floodway and/or floodplain shown.
M ❑ ❑ ❑ 25. Storm drainage analysis. (Data to be provided for all watercourses entering and leaving the plat
boundary.)
Or ❑ Ft' ❑ 26. Preliminary storm drainage plan. (Typical ditch section required to be shown.)
❑ ❑ 0' ❑ 27. Names of recorded subdivisions abutting the plat area indicated.
(Plat book and page or instrument number required to be shown.)
El ❑ 8' ❑ 28. ❑ Residential plats: show names of owners of all unplatted tracts abutting the plat area
and names of owners of platted tracts in excess of 21/2 acres.
❑ Commercial plats: show names of owners of all abutting lands.
0 All plats: show names of all owners of any landlocked parcels within or abutting the plat.
subd.doc
03/01/10
DEPARTMENT OF NEIGHBORHOODS AND PLANNING
PRELIMINARY PLAT CHECKLIST(page two)
a
a
ae
�❑
U
a
F
W
°n
❑
zz
❑
❑
29. Metes and bounds legal description of the tract boundary. (Provide acreage to nearest one -tenth
of acre.)
❑
❑
❑
30. Zoning classification(s) within the plat boundary and of abutting areas shown.
❑
❑
❑
31. Municipal boundaries which pass through or abut the plat area shown.
17
❑
❑
❑
32. Phasing plan, if applicable, indicated.
❑
❑
10'
❑
33. Location of proposed PAGIS monuments shown.
THE FOLLOWING MAY BE REQUIRED PURSUANT TO SEC. 31-90 OF THE CODE OF ORDINANCES:
❑
❑
Pf
❑
34. Engineering analysis.
(Required where: a street grade variance is being requested; a portion of the plat maybe
floodprone, but the area is not covered by the FEMA maps; or, suspected soil conditions may
affect the structural or operational aspects of the facilities.)
THE OLLOWING IS REQUIRED PURSUANT TO SEC. 31-91 OF THE CODE OF ORDINANCES:
f
❑
D
❑
35. Provision of the "CeRificate of Preliminary Surveying Accuracy"; the "Certificate of
Preliminary Engineering Accuracy"; and the "Certificate of Preliminary Plat Approval'.
(The "Certificate of Preliminary Surveying Accuracy shall contain the wording that: "...the
plat has been surveyed and duly filed for record in the offices of the state surveyor and the
county circuit clerk and recorder within the last seven (7) years")
THE FOLLO
G IS REQUIRED PURSUANT TO SEC. 31-93 OF THE CODE OF ORDINANCES:
❑
❑
Ur
❑
36. A draft Bill of Assurance.