HomeMy WebLinkAboutS-1681 ApplicationPLANNING COMMISSION REVIEW CENTRAL ARKANSAS WATER 27 October 2011 NAME TYPE ISSUE COMMENTS HILL SHORT FORM PCD / 7101 PCD Z-8319-A All Central Arkansas Water requirements in COLONEL GLENN RD effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and location of the water meter. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. NAME TYPE ISSUE COMMENTS HATCHER SOCCER COMPLEX / SITE PLAN S-1681 NW CORNER OF PINNACLE VALLEY RD All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. 2 NAME TYPE ISSUE COMMENTS PARKWAY PLACE ADDN; TRACT PRD Z-3168-1 C PD-R / OAK MEADOW LN, S OF PARKSIDE DR All Central Arkansas Water requirements in effect at the time of request for water service must be met. A water main extension will be needed to provide water service to this property. Please submit plans for water facilities to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities. Approval of plans by Central Arkansas Water, the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. 4 NAME UNION RESCUE MISSION PD-O; 2129 CONFEDERATE BLVD. TYPEISSUE PD-O Z-8718 COMMENTS All Central Arkansas Water requirements in effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. Contact Central Arkansas Water regarding the size and location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. 5 NAME TYPE ISSUE COMMENTS ARKANSAS BAPTIST COLLEGE POD Z-8130-B NO OBJECTION. POD CUP 1811 W 16TH ST All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and location of the water meter. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. 5 NAME TYPEISSUE 6 WILLIAMS SHORT FORM, PD-R PRD Z-8717 DUPLEX; 401 STEVEN DR COMMENTS NO OBJECTION. All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and Location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This Fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. n NAME TYPE ISSUE COMMENTS PRATHER SHORT FORM, PD-R PRD Z-8715 COVERED PARKING; 4719 NORTH LOOKOUT NO OBJECTION. All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and location of the water meter. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. NAME 8 RIVERSTONE SUBD; PRELIM PLAT, PCD; I-30, HWY 5, ALEXANDER RD TYPE ISSUE COMMENTS PCD S-1680 PLAT SHOULD SHOW EASEMENTS FOR EXISTING WATER LINES ALONG JAN DR, DON DR, BEV DR, AND KAYWOOD DR. All Central Arkansas Water requirements in effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions maybe required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. Contact Central Arkansas Water regarding the size and location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. A water main extension will be needed to provide water service to this property. F-1 NAME TYPE ISSUE COMMENTS This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. JOHN COOLEY SHORT FORM, POD Z-8716 NO OBJECTION. POD, RECORDING STUDIO; 24201 BURLINGAME RD All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and Location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. fiK NAME COULSON OIL PCD; EXPAND AUTO SERVICE; 19500 CANTRELLRD TYPEISSUE PCD Z-6476-D COMMENTS NO OBJECTION All Central Arkansas Water requirements in effect at the time of request for water service must be met. Contact Central Arkansas Water regarding the size and Location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. 10 NAME TYPE ISSUE COMMENTS 11 MCDONALD'S AT PROMENADE, SITE PLAN Z-5936-K All Central Arkansas Water requirements in ZONING SITE PLAN, 17601 effect at the time of request for water service CHENAL PKWY must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. Contact Central Arkansas Water regarding the size and location of the water meter. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. 11 w 0 v 00 ro L n. O w 3 J C v C c � cc E C O V V +i to w7 .� �+ �+ �7 •+ +' v v v d C O d 0 d d d d d = d d a a a a a a a a c. N N L N N N N N •p N N C N C O 0 � 0 O m r � r0+ a0+ r0+ 'p 01 d d o 0! d d d Of 0! 01 d N u .0 a a a a g 'Z c �a a Lto H L L L L L V L L i•� C w 0 0= 0! O as at d as as as H H V H O H V H N H N N O c LO R R {0 > 01 01 H'> H Ce ow ow C4a > C 0 d O O lE0 CC a4 w H V C. v a w a C . V a w a v 'Z c O O d O 00 0 0 d O 0 C O 00 C 01 C O —0p •� C d C ' C C C; C 0 d a > 000 > c R > 0! R > d m > d R > 0 03 > 0! > a > 0CL L L a 3 0 Q: IL N a 0 a 0 d 0 4 0 d 0 A. 0 d 0 X 0 g a o is •N � O. ds � d0 CL 0 .9 p m N 'C d m 0! H z H � O v � Of 0 C C C N d 0! Ci 01 v � � _ C � .� � O .O > 0 R O O � — � s 'C 4"'�., d R_ aL ci a ci = d 3 G� E o O z' U Y 0 m a v 2 u 0 ao m m o a) v7 w P Go 0 d 00 00 wM P M % M P T. P. V,O P LD LO I- M CD Ln LO 00 00 00 00 00 00 N N N N N N N N N o d H H City of Little Rock Department of Planning and Development 723 West Markham Street Little Rock, Arkansas 72201-1334 Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 DATE: October 10, 2011 Entergy (2) Center Point - ARKLA AT & T (2) Central Arkansas Water Little Rock Wastewater Pulaski County Planning Little Rock Fire Department Planning Zoning and Subdivision NAME: Hatcher Soccer Complex Subdivision Site Plan Review TYPE OF ISSUE: Subdivision Site Plan Review FILE NUMBER: S-1681 LOCATION: Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road Public Works: Engineering, Traffic (2) Parks and Recreation Department Planning and Development — Site Plan Review Planning and Development Graphics CATA TO WHO IT MAY CONCERN: On November 17 2011 the Little Rock Planning Commission will consider the above referenced issue. NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on October 21, 2011. NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on October 27, 2011. A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or recommendations will be appreciated. Sincerely, Don a es, AICP Subdivision Administrator (Please respond below and return this letter with your comments for our records.) Approved as Submitted. PLEASE RETURN COMMENTS BY October 24, 20_11. Easement (s) required (See attached plat or description.) *To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the easement or the request will not be included in the Planning Commission agenda. Comments: a4 E By: Enclosure 0 AF R2 OS ° fi o• R2 CUP i �op r• ® � R5 Pl e Area Zoning Case: 5-1681 N Location: NW corner of Pinnacle Valley Road and County Farm Road Ward: na PD: 20 0 175350 700 Feet CT: 42.05 TRS: T2N R13W7 is SOCM f'iEkr) I E-tMNG SOCCER Fir, k i MAL'NEIWE CONCES1,10N I Rivt ..R RESTROOM IF KING S-1681 * HATCHER SOCCER COMPLEX SUB. * SITE PLAN REVIEW NWC PINNACLE VALLEY & PINNACLE VALLEY III City of Little Rock CcDepartment of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 November 18, 2011 Hatcher Properties 6800 Pinnacle Valley Road Little Rock, AR 72223 Re: Hatcher Soccer Complex Subdivision Site Plan Review, located on the Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road (S-1681) Dear Sirs: This is to advise you that in connection with your request concerning the above referenced file number the following action was taken by the Planning Commission at its meeting on November 17, 2011: Approved with conditions. Recommended approval with conditions. Recommended approval as submitted. Denied your request as submitted. Deferred to the Meeting. X Other: withdrew your request If you have any questions concerning any other matter please do not hesitate to contact me at 371-6821. Respectfully, Donna James, AICP Subdivision Administrator James, Donna From: Andrew Johnson [andrew@jadeeconstruction.com] Sent: Thursday, November 10, 2011 9:43 AM To: James, Donna Subject: RE: Subdivision Committee Comments - Hatcher Soccer Complex Good morning Donna, Unfortunately Greg had a mtg with the local property owners and they were not in favor of the project so Greg decided to withdraw for now. Sorry for any inconvenience, Andrew Johnson President Jadee Construction, Inc. 211 Dellmere Drive Hot Springs, AR 71913 501.282.0169 andrew@jadeeconstruction.com www.jadeeconstruction.com I- please don't print this e-mail unless you really need to NOTICE: This e-mail message and any attachments may contain confidential information. If you are not the intended recipient, you are not entitled to review, retransmit, convert to hard copy, copy, use or disseminate this e-mail or any attachments. If you have received this e-mail in error, please immediately notify us by return e-mail or by telephone at (501) 282-0169 and delete this message. Please note that if this e-mail message contains a forwarded message or is a reply to a prior message, some or all of the contents of this message or any attachments may not have been produced by Jadee Construction, Inc. This notice is automatically appended to each e-mail leaving Jadee Construction, Inc. Thank you for your cooperation. -----Original Message ----- From: James, Donna [mailto:DJames@littlerock.org] Sent: Wednesday, November 09, 2011 11:15 AM To: Jadee Construction Subject: RE: Subdivision Committee Comments - Hatcher Soccer Complex I received a call today indicating this application was being withdrawn. Do you have any info concerning the withdrawal? -----Original Message ----- From: Jadee Construction [mailto:andrew@jadeeconstruction.com] Sent: Thursday, November 03, 2011 9:40 AM To: James, Donna Subject: Re: Subdivision Committee Comments - Hatcher Soccer Complex Notices have been taken care of from beach ... I'm in bed with my two kids with strep and been throwing up since Tuesday mid morning ... I'll check on things in a few. Thanks for the message Sent from my iPhone Andrew Johnson President Jadee Construction, Inc. 1 Red Oak Ridge 175 Dellmere Drive Hot Springs, AR 71913 www.jadeeconstruction.com andrew@jadeeconstruction.com 501.282.0169 On Nov 3, 2011, at 9:37 AM, "James, Donna" <DJames@littlerock.org> wrote: > I did not received your responses from Subdivision Committee comments - they were due yesterday - please submit in writing your responses to the comments provided at the October 27th Subdivision Committee meeting. I need the responses no later than this afternoon to continue to move forward on the current agenda. > Also your notices to the property owners within 200-feet was to be mailed yesterday - if the notices were not mailed yesterday then the item must be deferred to allow for proper notification. 2 tFk City of Little Rock Department of Planning and Development 723 West Markham Street Little Rock, Arkansas 72201-1334 Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 DATE: October 10, 2011 Entergy (2) Center Point - ARKLA AT & T (2) Central Arkansas Water Little Rock Wastewater Pulaski County Planning Little Rock Fire Department Planning Zoning and Subdivision NAME: Hatcher Soccer Complex Subdivision Site Plan Review TYPE OF ISSUE: Subdivision Site Plan Review FILE NUMBER: S-1681 LOCATION: Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road Public Works: Engineering, Traffic (2) Parks and Recreation Department Planning and Development — Site Plan Review Planning and Development Graphics CATA TO WHO IT MAY CONCERN: On November 17, 2011 the Little Rock Planning Commission will consider the above referenced issue. NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on October 21, 2011. NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on October 27, 2011. A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or recommendations will be appreciated. Sincerely, Donna mes, AICP Subdivision Administrator (Please respond below and return this letter with your comments for our records.) Approved as Submitted. PLEASE RETURN COMMENTS BY October 24, 2011. Easement (s) required (See attached plat or description.) *To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the easement or the request will not be included in the Planning Commission agenda. Comments: By: Enclosure I 1\VI 1 - WI 1 11GJ I rle% I1u. .—JU-L VGI JJGYJ VI. L. .J1 G"V11 11-.JVrl11 1 G/G w eat Pawki Tiu ?"fedim District 23 2810 Whispering Pines Road Little Rock, Arkansas 72210 501-821-9320 October 31, 2011 City of Little Rock - Planning Commission 723 W. Markham St. Little Rock, AR 72201 RE: Rezoning — 24201 Burlingame Rd. Shane Harvey .1, Ronald. J. Wheeler — fire Chief., lave been made aware of the proposal to rezond property at 24201 Burlingame Rd. The West Pulaski moire Protection District #23 provides fire protection service to this area along with first responder Emergency Medical Services. 1f you have .questions or need, additional ii-Y.fonnadon 1 may be contacted at (50.1) 529- 2004. Sincerely, Ronald J. Wheeler, Fire Chief cc. Deb Crow, District Assessor file Et City of Little Rock Department of Planning and Development 723 West Markham Street Little Rock, Arkansas 72201 133} Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 DATE: October 10, 2011 Entergy (2) Center Point - ARKLA AT & T (2) Central Arkansas Water Little Rock Wastewater Pulaski County Planning Little Rock Fire Department Planning Zoning and Subdivision NAME: Hatcher Soccer Complex Subdivision Site Plan Review TYPE OF ISSUE: Subdivision Site Plan Review FILE NUMBER: S-1681 LOCATION: Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road Public Works: Engineering, Traffic (2) Parks and Recreation Department Planning and Development — Site Plan Review Planning and Development Graphics CATA TO WHO IT MAY CONCERN: On November 17,2011 the Little Rock Planning Commission will consider the above referenced issue. NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on October 21 2011, NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on October 27, 2011. A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or recommendations will be appreciated. Sincerely, Donna mes, AICP Subdivision Administrator (Please respond belowand morn this letter with your comments for our records.) Approved as Submitted. PLEASE RETURN COMMENTS BY October 24, 2011. Easement (s) required (See attached plat or description.) *To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the easement or the request will not be included in the Planning Commission agenda. Comments: City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 DATE: October 10, 2011 1-00000 Entergy (2) Center Point - ARKLA AT & T (2) Central Arkansas Water Little Rock Wastewater Pulaski County Planning Little Rock Fire Department NAME: Hatcher Soccer Complex Subdivision Site Plan Review TYPE OF ISSUE: Subdivision Site Plan Review FILE NUMBER: S-1681 LOCATION: Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road Public Works: Engineering, Traffic (2) Parks and Recreation Department Planning and Development — Site Plan Review Planning and Development Graphics CATA TO WHO IT MAY CONCERN: On November 17 2011 the Little Rock Planning Commission will consider the above referenced issue. NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on October 21, 2011. NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on October 27 2011. A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or recommendations will be appreciated. Sincerely, Donna mes, AICP Subdivision Administrator (Please respo elow and return this letter with your comments for our records.) Approved as Submitted. PLEASE RETURN COMMENTS BY October 24 2011. Easement (s) required (See attached plat or description.) *To all utilities,. If an easement is requested which is in excess of 10 feet in width, provide justification for the easement or the request will not be included in the Planning Commission agenda. 19 By: Enclosure \! C r 10/18/2011 11:11 5013408274 PULASKI COUNTY PLANN PAGE 02 Et of Little Rock Department of Planning and Development 723 West Markham Street Uttle Rock, Arkansas 72201-1334 Phone; (501) 371-4790 Fax: (501) 399-3435 or 371-68$3 DATE. October 10, 2011 Entergy (2) Center Point - ARKLA AT&T(2) Central Arkansas Water Little Rock Wastewater ,Pulaski County Planning Little Rock Fire Department Planning Zoning and Subdivision NAME: Hatcher Soccer Complex Subdivision Site Plan. Review TYPE OF ISSUE: Subdivision. Site Platt Review FILE NUMBER: S-1681 LOCATION- Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road Public Works: Engineering, Traffic (2) ,Parks and Recreation Department Planning and Development -- Site Plan Review Planning and Development Graphics CATA TO WHO IT MAY CONCERN: On November 17, 2011 the Little ,bock Planning Commission will consider the above referenced issue. NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on October 21, 2011. NOTE, The Subdivision Comtrtittee Meeting at which this issue will be discussed will be held on October 27, 2011. A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or recommendations will be appreciated. Sincerely, Qua .Hates, .AICF Subdivision Administrator (Please respond below and return this letter with your comments for our records.) Approved as Submitted. PLEASE RETURN COMMENTS BY October 24, 2011. Easement (s) required (See attached plat or description.) .To all utilities. If an easement is requested which is in excess of 10 feet in width, ,provide justification for the easement or the request will not be included in the Planning Comm4slon agenda. L.arnmenEs: l �' �yt � . 1 'T 0' '06 r, rJ or l fa..r -bf, 0 fJ f"n Oe- r t1% By; T � AJI L r k c (o-" e t f d d fzUP 1 ore'L En re City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND DATE: October I L 2011 TO: Pinnacle ValleyNei hborhood Owners Association Mr. Nicholas Also ADDRESS: 6 Waterford Dr Little Rock AR 72223 REQUEST: Hatcher Soccer Complex Subdivision Site Plan Review S-1681 a re uest to allow the placement of four soccer Wa n fields bleachers and a concession and restroom building one this 40+ acre parcel. GENERAL LOCATION OR ADDRESS: located on the Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road OWNED BY/APPLICANT: Grp Hatcher Properties NOTICE IS HEREBY GIVEN THAT an application for a Subdivision Site Plan Review of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L-R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on November 17, 2011 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND DATE: October 11, 2011 TO: River Valley POA Louis Bianco ADDRESS: 8108 Pinnacle Valley Road Little Rock AR 72223 REQUEST: Hatcher Soccer Com lex Subdivision Site Plan Review S-1681 a request to allow the placement of four soccer plgtng fields bleachers and a concession and restroom building one this 40+ acre parcel. GENERAL LOCATION OR ADDRESS: located on the Northwest corner of Pinnacle Valley Road and Pinnacle Valley Road OWNED BY/APPLICANT: Greg Hatcher Properties NOTICE IS HEREBY GIVEN THAT an application for a Subdivision Site Plan Review of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L.R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on November 17, 2011 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development HATCHER PROPERTIES POST OFFICE BOX 3505 LITTLE ROCK, AR 72203 The purpose of this memorandum is to outline and set forth the development rationale of the proposed site plan review. The property identified by the plat attached to this memo is currently zoned AF and has no current usage. The proposed amendments to the site are to include four (4) full size soccer fields, six small practice fields, non -permanent players' benches in between the four large fields, and minimal non- permanent bleachers on the outside boundaries of the large fields. The scope of work that is planned to be completed includes • grading the land to promote drainage to the north and north west of the property • Installing multi -zoned sprinkler systems to properly irrigate the grounds • Install Bermuda Grass on all areas marked to be practice or play fields (-50,000 yards) ■ Install a parking lot designed by Tanner Weeks to meet the requirements of city beautification and handicap requirements. ■ Propose to construct a men/woman's bathroom on each side and a concession area on the end (bathrooms are proposed to have 4 stalls for woman, two stalls for men and three urinals for men) We would like to ask for special consideration be taken due to time of submission in relation to the time of year. These fields are planned for play in early spring of 2012 and in order to prep the ground, lay the irrigation system and put down the sod we are asking that we be allowed to begin the grading and get the sod down as soon as possible in order to give the sod time to root and establish itself prior to the cold weather beginning and large amounts of rain. We would greatly appreciate if we could begin to put the sod down as soon as possible please. Sincere G Matcher Nigident Hatcher Properties sitpin.doc 03/01/10 INFORMATION SHEET FOR SUBDIVISION PUD's PD's ZONING OR SUBDIVISION SITE PLAN REVIEWS ITEM NO. DATE 0 r .� FILE NO. LOCATION: DEVELOPER: 10TC.V�4JJ[I�.cN STREET ADDRESS �b� � I A Kk Vl CITY/STATE/ZIP TELEPHONE NO. - -+S 3l ENGINEER:STREETADDRESS CITY/STATE/ZIP TELEPHONE NO. AREA �(-J) . i FT. NEW STREET ZONING ►"llr PLANNING DISTRICT VARIANCES REQUESTED 1.) 2.) 3.) 4.) NUMBER OF LOTS I (e,P��, rZ PROPOSED USES L ')Cam) ] J CENSUS TRACT City of Little Rock Planning and Development Filing Fees Date l L) LI 6 , 20_L1 Annexation Board of Adjustment Cond Use Permit/T UP Final Plat Planned Unit Dev Preliminaiy Plat F Special Use Permit Rezoning Site Plans Street Name Change Street Name Signs Number at ea Public Hearing Signs Number at 6"9 ea Total C $3