Loading...
HomeMy WebLinkAboutS-1665-H Staff AnalysisITEM NO.: 2 File No. S-1665-H NAME: Wildwood Ridge Phase IV Preliminary Plat LOCATION: West end of Summershade Drive Planning Staff Comments: 1. Provide notification of the (abutting property ownerstpropeq owners within 200-feet of the site) including the certified abstract list, notice form with affidavit executed and proof of mailing. The notice must be mailed no later than April 10, 2019. The Office of Planning and Development must receive the proof of notice no later than April 19, 2019. 2. Provide linear feet of internal streets. Correct General note #3. 3. Indicate any natural features, drainage channels, cultural features and the location for any finnrininin ren tnP nrnnncar; nrliminary nigL 4. Provide names of recorded subdivisions abutting the plat area (plat book and page or instrument number required to be shown). Variance/Waivers, 1. Advance grading of lots with installation of infrastructure. 2. 20 foot front yard setback for all lots. Engineering cc-m-rnein-ts: P1 _ _ 1_ 1: _ vvo rI _ _ P, _ � J .1. _ _ _ . rur�nc vv�rres �,Uncanrvrrs. 1. Sidewalks with appropriate handicap ramps are required in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. 2. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is a variance being requested to advance grade the lots with construction of the street and utilities? 3. Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). 4. Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner's association. 5. Fire apparatus access roads shall not exceed 10 percent in grade without approval of the Fire Marshall. 6. Per the Appendix D of the Fire Code, dead end fire apparatus access roads in length of 150 to 500 ft require a cul de sac turnaround with a 96 ft diameter. 7. Contact USPS to determine if a mail kiosk will be required to be provided. If so, show location on plan. 8. Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate ITEM NO.: 2 File No. S-1665-H of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 9. Hauling of fill material on or off site over municipal streets and roads requires approval prior, to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 10. Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 11.All public drainage easements must be unobstructed and access provided to the public right-of-way by constructed infrastructure and/or documented on the final plat. 12.All public drainage easements must contain drainage infrastructure approved by the City of Little Rock Public Works Department. 13.100 year overflow swales must be constructed and placed within public drainage easements. Utilities/Fire Department/Parks/County Planning: Little Rock Water Reclamation Autho Sewer main extension required with easements if new sewer service is required for this project. LRWRA Commission Approval and Zero Capacity Fee Required if pumping out of sewer basin. Entergy: Entergy does not object to this proposal. There do not appear to be any conflicts with existing electrical utilities at this location. A single-phase underground power line already exists along Summershade Drive feeding previous phases of the subdivision. Contact Entergy in advance to discuss electrical service requirements, or adjustments to existing facilities (if any) as this project proceeds. Centerpoint Energy: AT & T: No comments received. entral Arkansas Water: NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for water service must be met. Fire Department: Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. ITEM NO.: 2 F Ile iyc7. S- i 6054"1 Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loadin Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving ClIrT�1rP r_ananl� f7I 411fincithrin me. uripust!ij 1020 01 ME_ cl[7[72i2tus vVeIU1III 1U CIL ICdjL ! GJ,uuu ���..- -rr------a -r - - - -- -r.r- .. pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family, ITEM NO.: 2 File No. S-1665-H dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: 1. Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Parks and Recreation: No comments received. County Planning: No comments received. Building Codes/Landscape: Building Code: Secondary Fire Access Road should be constructed with this phase. Consult with Fire Marshals Office for further information. Landscape. No Comment. Transportation/Planning: Rock Region Metro: No comments received. Plannina Division: No comments. Revised plat/plan: Submit responses to staff issues and four (4) copies of a revised preliminary plat/plan (to include the additional information as noted above) to staff on or before April 10, 2019. If you have any questions please contact Dana Carney, dcarney@littlerock.gov or 501.371.6817 or Jamie Collins, gcollinsaa_..littlerock.gov or 501.371.6818. June 6, 2019 ITEM NO_: A NAME: Wildwood Ridge Phase IV Preliminary Plat LOCATION: West end of Summershade Drive DEVELOPER: Wildwood Phase 4, LLC 13,100 Pride Valley Road Little Rock, AR 72223 OWNER/AUTHORIZED AGENT: Wildwood Partners, LLC/owners White-Daters and Associates/authorized agent SURVEYOR/ENGINEER: White-Daters and Associates 24 Rahling Circle Little Rock, AR 72223 AREA: 1.94 acres WARD: 5 CURRENT ZONING: VARIANCENVAIVERS: NUMBER OF LOTS: 5 PLANNING DISTRICT- 19 R-2, Single Family FILE NO.: S-1665-H FT. NEW STREET: 115 LF CENSUS TRACT: 42.13 1. Advance grading of the entire site with installation of the infrastructure. 2. 20 foot front building line for the five lots. STAFF REPORT AND RECOMMENDATION: On April 9, 2019 the applicant requested deferral of this item to allow for time to pursue various options to address Fire Department issues. Staff recommends deferral of the item to the June 6, 2019 meeting. June 6, 2019 SUBDIVISION ITEM NO.: A FILE NO.: S-1665-H PLANNING COMMISSION ACTION: (APRIL 25, 2019) The applicant was present. There were no objectors present. Staff informed the commission that, on April 9, 2019, the applicant had requested deferral of the item to allow time to pursuer various options to address Fire Department issues. There was no further discussion. The item was placed on the consent agenda and deferred to the June 6, 2019 agenda. The vote was 10 ayes, 0 noes and 1 absent. STAFF UPDATE AND RECOMMENDATION: On May 16, 2019, the applicant requested withdrawal of this item. Staff recommends approval of the withdrawal request, without prejudice. PLANNING COMMISSION ACTION: (JUNE 6, 2019) The applicant was not present. There were no objectors present. Staff informed the commission that the applicant had requested withdrawal of the item on May 16, 2019. There was no further discussion. The item was placed on the consent agenda and approved for withdrawal, without prejudice. The vote was 8 ayes, 0 noes and 3 absent.