HomeMy WebLinkAboutS-1639 Map 7KCJ (KEYED CONSTRUCTION JOINT) LOCATED BY CONTRACTOR INDICATES REMOVABLE CAP. REMOVE CAP AFTER CONCRETE IS CURED FOR MINIMUM OF 56 DAYS AND FILL VOID W/MM-80 SEMI -RIGID EPDXY AT CONCRETE EXPOSED TO VIEW. CAP TO REMAIN IN PLACE AT OTHER LOCATIONS. 3,000 PSI CONCRETE (TYP.) W.W.F. 6X6-W2.9XW2.9 FLAT SHEETS ONLY 1 2" ON CHAIRS ® 4'-0" O.C. BOTH WAYS OR BEAM BOLSTERS W/ CONTI LLS RUNNERS SAW CUT MIN. 1 " DEEP AT LOCATIONS INDICATED ON THE SLAB PLAN FILL JOINT W/ NON -SHRINK GROUT OR POLYURETHANE TYPE FILLER A MIN. 56 DAYS AFTER CONCRETE IS PLACED INSIDE BUILDING. CUT EVERY OTHER FABRIC WIRE THAT CROSSES A CONTROL JOINT \\\\\ NV GALV. STEEL EDGE FORM W/ REMOVABLE A W/ DIMENBOTH SIONS \\� \ \�� TYPICAL UNDER SLABAS W/FORM OIL-W/24" LONG �� —CRUSHED MIL VAPOR BARRIER METAL SUPPORT STAKES2" OAT \� ORGRAVEROCK COMPACTED STRUCTURAL FILL NOTE: KEYED JOINT MAY BE REPLACED WITH #4 DOWEL CEN ED IN SLAB NOTE: SAW CUT TO BE MADE WITHIN 24 X32" LONG. EMBED 16" INTO INITIAL CONC. PLACEMENT AND GREASE AND HRS. OF CONCRETE PLACEMENT. SLEEVE EXPOSED END. DOWELS TO BE PLACED AT 24" O.C. MAXIMUM. A KCJ (KEYED CONTROL JOINT) B CJ (CONTROL JOINT) SCALE 1" =1'-0" COLUMN FLOOR DRAIN @ SLOPED SLAB `J SCALE : 1" =1'-0" TYPICAL SLAB ON GRADE REINF. & KEYED CONTROL JOINT (KCJ), CONTROL JOINT SCALE : 1" =1'-0" 10'-0" EXTERIOR OR INTERIOR FOOTING 11 BOTTOM OF TRENCH EXCAVATION SHALL NOT EXTEND BELOW THIS LINE i NOTE: THE CONTRACTOR SHALL COORDINATE ALL EXCAVATION OPERATIONS WITH BUILDING FOUNDATION REQUIREMENTS ).C. 30# FELT GREATER THAN vi �i r 0 0 Of FOR LOCATIONS Z a WA z 0 Ln Ln 1) #4 X 2'-0" MERE O.D. OR GROUPING OF a ;EVERAL PIPES IS GREATER THAN 4" :ONCRETE FLOOR SLAB 0 ;EE DETAIL SLAB -ON -GRADE PENETRATION SCALE : 1" =1'-O" FLOOR DRAIN, & SLAB PENETRATION DETAILS WALL OR COLUMN FOR PIPES THAT WOULD "HIT" SIDE OF FOOTING LOWER FOOTING SO THAT PIPES PASS THROUGH ALL ABOVE FOOTING FILL WITH _ ____ _ _ -- ° PEDESTAL NON -SHRINK a Il i - GROUT a SEALANT--�-� __--I i-----v�------------+ ---- t SLEEVES 2" PIPE a a BACKING ----1---------- ---------FOOTING— a —I LARGER THAN MATERIAL'- MATERIAL O.D. OF EXTEND BOTTOM CONTINUOUS CONCRETE ENCASEMENT AT PIPE IN TRENCH - 0 PIPES, U.N. SCH 40 GALV REI FORCING ACROSS WIDTH OF FOOTING ° -`-{-" ( P.) SEE SCHEDULE FOR REINFORCING— STEELSLE PIPE ° ° a e OR USE CORNER BARS W/60 BAR 0 LAP _ M SEAL WITH WATERPROOF SPLICE. j TRENCH o SEALANT i a� EXCAVATION q 3-#4'S CONT. IN BOTTOM I I-- NOTE: "D 6 "D" OF SLEEVE SLOPE TO BE A FUNCTION OF ANGLE OF INTERNAL FOR PIPES 3'-0" OF LESS BELOW FOOTINGS PROVIDE i. FRICTION OF SOIL AN'D SLEEVE AND CONCRETE AS SHOWN, IF MORE THEN 3'-0" 4 TIES ® 24" O.C. a TO BE DETERMINED HY USE STEPPED FOOTING TO STAY WITHIN 3'-0" LIMIT NOTE: VERTICAL SLEEVE SIMILAR # CONTRACTOR SECTION ELEVATION TYP. SLEEVE DETAIL* -- VARIES NOT TO SCALE TRENCH EXCAVATION AT VICINITY OF INTERIOR & EXTERIOR FOOTINGS SCALE : 1/8" =1'-0" EXTERIOR SEE W-24 TRENCH EXCAVATION PERPENDICULAR TO EXTERIOR FOOTINGS NOT TO SCALE SCALE : 1/2" =1'-O" NOTE: VERTICAL BARS NOT SHOWN FOR CLARITY CENTER LINE OF COLUMN & FOOTING —BY PRE-ENGINEERED METAL BUILDING BY PRE-ENGINEERED METAL BUILDING ON PRE-ENGINEERED METAL BUILDING ON PRE-ENGINEERED METAL BUILDING PRE-ENGINEERED METAL BUILDING & SUPPUER DRAWINGS. SUPPLIER DRAWINGS. COLUMN LOCATE ON SLAB AS SHOWN ON PRE-ENGINEERED METAL BUILDING SUPPLIER DRAWINGS. i ANCHOR BOLT DIA. BY METAL BLDG. SUPPLIER LENGTH TO BE 2'-0" W/ 3"XYX Y4" PLATE IN BOTTOM W/ TWO HW HEX NUTS. EXTERIOR GRADE— (1) #4 CONT. SEE CIVIL (4) #4 DOWELS W/ 6" HOOKS SLAB, SEE DETAIL 1 THIS SHEET #5 HAIRPIN—B'—O" LEG SLAB, SEE DETAIL 1 THIS SHEET ^--_—_ 1 \ \ \\ I I TURNDOWN BEYOND #4 DOWEL � 36" O.C. � I CONT. FOOTING BEYOND I #3 TIES ® 36" O.C. _ (3)#4'S CONT. --— —�----- - - ------�---- IN BOTTOM ' ON 2 1/2" CHAIRS TYPICAL W-24 EXTERIOR FOOTING SCALE : 1" =1'—O" & TURN DOWN SLAB F-60 1'-4" 2'-4" 1'-4" 10" 2'-4" 10" #5's ® 6" O.C. EA. WAY F-48 1 TYPICAL F-46 & F-60 COLUMN FOOTING 0 SCALE : 1" =1'-C" NOTE: SEE FOUNDATION & SLAB PLAN-SHT. S-2.0 SEE SCHEDULE NEXT PLACEMENT FOR REINFORCEMENT 0-BA DIA LAP SPLICE a a o � I v. ° a ° �STAGGE LAPS ( P.) FORMED 1/2" X 7 1/4" KEY ACROSS WIDTH OF FOOTING CONTINUOUS FOOTING UUNSTRUCTION JOINT (SECTION) SCALE : 1/2" =1'-O" NOTE: VERTICAL DOWELS NOT SHOWN FOR CLARITY Z 0 0 U w z s d 0 U 0 0 a 0 z 0 U z r U z a z U W c O r a U z 0 U J W z z w r z } m 0 0 z z 0 crf z ¢ c 0 0 U 0 0 a w m r 0 z 3 0' 0 N_ S 0 0 a 0 z REVISIONS: ND-FDATE REVISION o ❑00In� N ❑ WZNOU L• • H cm]vW�Nz _JQm� ,zo �_ 0 In L,Lr z Ill ZInwj �LLL I w M T 1- U_ m _ ❑ Z z ❑ J ❑� w w W ❑ r 2 W Q It U] ❑ If1 Z] ❑ Z❑ ® N U zQ ��❑ ® H 0 ®wulNaw IPROJECT NAME: r OQ 1= z W Q Z W U U rr J OJ 0. SHEET TITLE: FOUNDATION & SLAB ON GRADE DETAILS PROJECT NUMBER: HW9-36❑ PROJECT DATE: JUNE 2009 SHEET NUMBER: S-3.0