HomeMy WebLinkAboutS-1639 Map 12SEE SITE PLAN AND CIVIL PLANS FOR ROUTING 1O NEW 24OV/1P, 200A, WEATHERPROOF, FUSED, LOCKABLE SERVICE ENTRANCE DISCONNECT SWITCH. FUSE AT 100A, 2O GROUND PER NEC ARTICLE 250. J NEW 18 CKT, 100A, 24OV,1P MLO PANELBOARD. SEE SCHEDULE THIS SHEET, PROVIDE WITH LOCKABLE, NEMA 3R ENCLOSURE. (3) #3, #8G, 1-1/4" C. O (3) #1, #6G, 1-1/4" C. :311 'C. W/ 3#12 TO HEUPAD UGHTING ® EXISTING 240V, HIGH LEG DELTA PANELBOARD WITH SPARE CAPACITY AND SPACE AVAILABLE FOR NEW 100A FEED TO PANEL "LA". FIELD VERIFY ALL REQUIREMENTS. SECURE PEAK DEMAND LOAD FROM UTILITY COMPANY TO ENSURE THAT NEW LOAD DOES NOT EXCEED PANEL RATING AFTER NEC MANDATED DIVERSIFICATION. OPROVIDE NEW 100A/2P CIRCUIT BREAKER TO MATCH EXISTING. NEW BREAKER SHALL BE SAME MAKE, MANUFACTURER AND AIC RATING. OPROVIDE NEW 20A/1P CIRCUIT BREAKER TO MATCH EXISTING. NEW BREAKER SHALL BE SAME MAKE, MANUFACTURER AND AIC RATING. 1 ELECTLE RICAL RISER DIAGRAM BURNDY #GAR OR EQUAL (LOCATE WITHIN 5' - 0" OF WATER SERVICE) — 1" OR LARGER METAL COLD WATER PIPING 10' - 0" LINEAR FOOT MINUMUM UNDERGROUND IN DIRECT CONTACT WITH EARTH AND ELECTRICALLY CONTINUOUS TO BONDING CONNECTION IN ACCESSIBLE LOCATION UNSPLICED - NEUTRAL TI REBAR PER NEC 250-81, 250-81b, & 250-SIC - EXOTHERMIC WELD CONNECTION - TYPICAL - STRUCTURE — BUILDING EXTEER CONDUCTOR TO BE INSULATED WHERE IN CONTACT WITH CONCRETE REINFORCED CONCRETE FOOTING o = EXOTH1ER%4C WELD CONKCTION (CADWELD OR EQUAL) 2 SERVICE SCALE NONE GROUNDING BUSHING WITH BONDING CONDUCTOR SAME SIZE AS GROUNDING ELECTRODE CONDUCTOR LOW RESISTANCE ENCASEMENT CADWELD "GEM" OR EQUAL (BELOW VAPOR BARRIER) 14 REBAR, 20' - 0" MINIMUM TOTAL LENGTH - LOCATE AS NEAR BOTTOM OF FOOTING AS POSSIBLE BUT NO LESS THAN 2" FROM BOTTOM AND SIDE OF FOOTING NCE GROUNDING DETAIL Q ` PANELBOARD; L VOLTAGE: 120/24OV, 10, 3W BUS RATING: 1ODA 100A M.L.O. TOTAL _ CONNECTED VA: TOTAL A 0 : - HANGER LOCATION: MFG. GE OR AND CUTLER HAMMER TYPE; EQUIP, GRD• YES BUS; ISOL GRID. NO BUS: TOTAL B - SURFACE MOUNTING: NEMA 3R ENCLOSURE: MINIMUM AI.C. 10,000 RATING: NG FED PANEL EXISTING FROM; LOAD (VA) SERVES P CAR. NO. n ^ ^ n n ^ ^ AB ¢¢ ^ ^ n ^ n (1 CAR. NO. P VT SERVES LOAD (VA) A s A s 1300 LIGHTING 1 1 2 1 SECURITY SYSTEM - 1300 UGHTING 3 4 1 EXHAUST FAN 1700 1200 OVERHEAD DOOR MOTOR 1 5 6 1 SPARE - 1200 GATE OPERATOR 1 7 8 1 SPARE - 500 EXTERIOR RECEPTACLE 1 9 10 1 SPARE - 850 EXTERIOR UGHTING 11 12 1 SPARE - 1080 RECEPTACLES 1 �3 14 1 SPARE - 1080 SPARE 15 16 1 SPARE - 1080 SPARE 17 18 1 SPARE - - SPARE 19 2O 1 SPARE - II PANELBOARD LEGEND 11 * U,L LISTED HACR TYPE CIRCUIT BREAKER • U.L LISTED ARC -FAULT CIRCUIT BREAKER COORDINATE LOCATION WITH PLUMBING PLANS ■ ROUTE THROUGH RELAY/TIMECLOCK r---------------------- 1 TIME CLOCK, TORK #DGLC, OR EQUAL, MOUNTED IN ELEC. RM. 141 SEE NOTE I BELOW 20A, 120V "LA"-4 PHOTOELECTRIC CELL TORK #EPC1, OR EQUAL, CONDUIT MOUNTED ON ROOF y9IE: 1. TIME CLOCK CIRCUIT #1 PROVIDES (PHOTO ON / TIME OFF) OPERATION. CIRCUIT #2 PROVIDES (PHOTO ON / PHOTO OFF) OPERATION. VERIFY DESIRED OPERATION WITH OWNER. 3 LIGHTING CONTROL DIAGRAM SCALE NONE 110 LTG It l000//S<�oP ee ARKANSAS�= e REG`itED�` P1t0 E IONAL\l,; I ER � _E * ee �T 10213��i'ee V R/ loci z O H n E U N Ld c� LJ H Q 0 LiJ F---IlI M--�1 IW F--1 H+W Heiple Wiedower Architects Planners 319 President Clinton Ave. Little Rock, AR 72201 (t)501-707-0115 (f) 501-707-0118 Project No: HW9-360 Date: 06-16-09 Sheet Title: ELECTRICAL DETAILS 4 Of 4 Sheet No: E4m1 e Drawing Property of H+W Architects PLLC 2009