Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
S-1633 Map 1
4' VIN CHAIN W/ GA SITE NOTES 1. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATEAEDERAL REGULATIONS AND CODES AND OSHA STANDARDS 2 CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS. 3. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 4. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS 5. ALL GURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 6. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 7. CONTRACTOR SHALL MATCH PROPOSED CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. & CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE. (1FNFRAo N07ES 1. ENGINEER'.` NOTICE TO CONTRACTOR: THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. 2 SAFETY NOTICE TO CONTRACTOR: IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE. 3. OWNERSHIP OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF GRAFTON, TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF GRAFTON, TULL, SPARKS &ASSOCIATES, INC. 4. CONTRACTOR SHALL NOT CAUSE ANY INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING THE CONSTRUCTION OF THIS PROJECT THE CONTRACTOR SHALL NOT DISRUPT ACCESS TO ADJACENT PROPERTIES AT ANY TIME DURING CONSTRUCTION. 5. THE CONTRACTOR SHALL CONTACT THE ENGINEER FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED ON THE PLANS AND/OR SPECIFICATIONS. 6. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL REQUIRED/NECESSARY SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT TO MEET OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. GRAPHIC SCALE =N FEET I EMOVE EXISTING URB ANDSCAPE IREA )IRECTIONAL SIGN 36ox48' MAX. MATCH EXISTING SIDEWALK NEW 5' CONC. SIDEWALK NEW CURB & GUTTER LANDSCAPE AREA STANDARD PARKING SPACES - 6 HANDICAP PARKING SPACES - 2 TOTAL PARKING SPACES - 8 COVERAGE LEASE PARCEL 16,000 S.F. 100% PORTABLE CLASSROOM BUILDING No.1 1,536 S.F. 9.6% PORTABLE CLASSROOM BUILDING Ni 1,536 S.F. 9.6% COVERAGE VEHICLE USE AREA 9,633 S.F. 100% LANDSCAPE AREA 787 S.F. 8.1% ENGINEER'S NOTICE TO CONTRACTOR THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS ARE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION OF THEIR WORK. SAFETY NOTICE TO CONTRACTOR IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE CONSTRUCTION SITE OWNERSHIP OF DOCUMENTS THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC., AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITH OUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL, SPARKS & ASSOCIATES, INC. NOTIFICATION OF LIMITED SERVICES GRAFTON. TULL, SPARKS & ASSOCIATES, INC., (CTSA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES ON ALL OR A PORTION OF THE WORK INDICATED ON THESE DRAWINGS, THEREFORE, THE CTSA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT THE CTSA ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION AND ADMINISTRATION Of THESE DOCUMENTS AND/OR DEVIATIONS THEREFROM AND THE EFFECTS THOSE CHANGES MAY HAVE ON ANY AND ALL (RELATED TRADES OR CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT, EXCEPT AS SPEC— IFICALLY REQUIRED IN THE CTSA's SERVICES AGREEMENT WI THE OWNER. O) ti- Lit m n N SYMBOLS FOUND IRON PIN LIGHT POLE POWER POLE TELEPHONE PEDESTAL TV PEDESTAL MANHOLE SANITARY SEWER CLEANOUT GAS METER GAS VALVE STORM SERER PIPE DOWN GUY WATER VALVE FIRE HYDRANT ASSEMBLY AIR RELEASE VALVE FIRE DEPARTMENT CONNECTION WATER METER SPRINKLER HEAD ELECTRIC PEDESTAL GRATED INLET DROP INLET TREE TREE TO BE REMOVED LINEWORK .q 7 CURB 1206-- -- -- -- -- -- INTERMEDIATE CONTOUR ----._._------__---___.1zos--._—e —- INDEX CONTOUR SANITARY SEWER LINE —_—G —G GAS LINE WATER LINE (SPECL'"Y SIZE & TYPE) UNDERGROUND TELEPHONE UNDERGROUND ELECTRIC OVERHEAD ELECTRIC UNDERGROUND TELEVISION OVERHEAD TELEVISION CHAIN LINK FENCE WOOD FENCE �TZ►'irt�i RIGHT OF WAY SYMBOLS LINEWORK o SET IRON PIN ------------ ------------ EASEMENT LIGHT POLE lq POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 INTERMEDIATE CONTOUR is IV PEDESTAL QQ MANHOLE 12^` INDEX CONTOUR 0 SANITARY SEWER CLEANOUT A GAS METER SANITARY SEWER LINE N GAS VALVE r c O STORM SEWER PIPE GAS LINE -x STRUCTURE NUMBER WATER LINE ■ ■ N WATER VALVE FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE AIR RELEASE VALVE WE 1 rra 1 .= FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER ns OVERHEAD ELECTRIC 110 BACK FLOW PREVEJTER G REDUCER FIBER OPTIC PLUG VALVE umv ucty UNDERGROUND TELEVISION ❑ GRATED INLET am OVERHEAD TELEVISION —x K x —x CHAIN LINK FENCE DROP INLET — WOOD FENCE CAP UNITS) MODULAR BLOCK MOSAIC BY VERSA-LOK EXISTING PAVEMENT FILTER FABRIC BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY s PROPERTY LINE n i -5>��� -11 l i 1 "v TOP SOIL BACKFILL MODULAR BLOCK PLANTER WALL DETAIL NTS NOTE: 800 Exchange Ave., Suite 201 Conway, Arkansas 72032 Crafton Tull Sparks ® engineering 501.328.3316 t 501.328.3325 f www.craftontullsporks.com COVENANT KEEPERS SCHOOL LITTLE ROCK, ARKANSAS Key Plan No. Description Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crofton, Tull, Sparks & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crofton, Tull, Sparks & Associates, Inc. �gS µUCTION PROJECT NO: 928-1 L ISSUEDATC 06/15/09 �o� THIS CONTACT. F.RIGGINS DOCUMENT IS N CHECKED BY: 2 PRELIMINARY IN NATURE AND IS NOT PRELIMINARY A FINAL, SIGNED a PLANS N AND SEALED ©2009Crofton. Tun, Sparks DOCUMENT 8 Associates, Inc. d' loO Nolionals LAYOUT PLAN - PHASE I C l 001 SILL 0 2009