HomeMy WebLinkAboutZ-10106 Staff Report 120224December 14, 2024
ITEM NO.: 19 FILE NO.: Z-10106
NAME: Anchor Realty Investments – PCD
LOCATION: 13240 Cantrell Road
DEVELOPER:
Anchor Realty Investments, LLC (Owner)
102 Country Club Parkway
Maumelle, AR 72213
OWNER/AUTHORIZED AGENT:
Timothy W. Grooms (Agent)
8114 Cantrell Road, Suite 100
Little Rock, AR 72227
SURVEYOR/ENGINEER:
Bond Consulting Engineers, Incorporated
2801 T. P. White Drive
Jacksonville, AR 72076
AREA: 2.5 acres NUMBER OF LOTS: 2 FT. NEW STREET: 0 LF
WARD: 4 PLANNING DISTRICT: 1 CENSUS TRACT: 42.05
CURRENT ZONING: R-2
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting to rezone the property from R-2 to PCD to allow for the
development of two (2) quick-service restaurants. The property is within the
Highway 10 Design Overlay District.
B. EXISTING CONDITIONS:
Lot 7, Block 8, Josephine Pankey 3rd Addition, contains an existing single-family
dwelling in the southwestern portion of the overall site. The remaining lots within
Block 8 are undeveloped. There is a mixture of zoning and uses surrounding the
property.
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property located within 300 feet of the site and all neighborhood
associations registered with the City of Little Rock were notified of the public
hearing.
D. ENGINEERING COMMENTS:
1. The site plan leaves too much open for comment.
2. Path to both developments from the Right of Way shall be installed.
3. All ADA guidelines to be met.
4. ARDOT permitting will be required as well as anything else they may want
done, i.e. dedication of Right of way and so on.
5. The site plan will have to be finalized and submitted for staff to review at the
time of the grading/building permit.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority:
1. A sewer extension may be required. Please submit wastewater plans to
LRWRA for review and approval.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: No comments received.
Fire Department:
Fire Hydrants
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
3
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. I f
the grade exceeds 10 percent, approval will be denied, and the applicant
must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2021 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Buildings or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area . Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provided with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
buildings are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceeds 30’, approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
4
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum
of 30 feet from the building and shall be positioned parallel to one entire side of the
building. The side of the building on which the aerial fire apparatus access road is
positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be placed with the
approval of the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2021 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Jason Lowder 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram 501-918-
3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape:
1. Any new site development must comply with the City’s minimal landscape and
buffer ordinance requirements. Refer to the Code of Ordinances, Chapter 15
Landscaping and Tree Protection, and Chapter 36, Article IX – Buffers and
Screening.
2. Site development plans, with landscape and screening, must be submitted for
review, and approval, prior to site clearing and tree removal.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
5
The request is in the River Mountain Planning District. The Land Use Plan shows
The Residential Low Density (RL) category provides for single family homes at
densities not to exceed 6 dwelling units per acre. Such residential development is
typically characterized by conventional single family homes but may also include
patio or garden homes and cluster homes, provided that the density remains less
than 6 units per acre. for the requested area. The Residential Low Density (RL)
category provides for single family homes at densities not to exceed 6 dwelling
units per acre. Such residential development is typically characterized by
conventional single family homes but may also include patio or garden homes and
cluster homes, provided that the density remains less than 6 units per acre. The
application is to rezone from R-2 to PCD.
Surrounding the application area, east of the site is PK/OS. North and west of the
site are mostly undeveloped platted land with a few single family residences. On
the south of the site is Cantrell Road.
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
6
The subject site is located in the Highway 10 Design Overlay District (Ord. 15965).
Master Street Plan:
Cantrell Road is a Principal Arterial on the Master Street Plan. Principal Arterials
are roads designed to serve through traffic, and to connect major traffic generators
or activity centers within urbanized areas. The standard Right of way of 110 feet
is required. Sidewalks are required on both sides. This street may require
dedication of right-of-way and may require street improvements.
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
7
Bicycle Plan:
Cantrell Road is on the Master Bike Plan as a Proposed Class I Bike Path. Class
I Bike Paths are a route designated for the sole use of bicycles that is physically
separated from vehicular lanes.
Historic Preservation Plan:
The application, as shown, should have no effect on identified historic resources.
H. ANALYSIS:
The applicant is requesting to rezone the property from R-2 to PCD to allow for the
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
8
development of two (2) quick-service restaurants. The property is within the
Highway 10 Design Overlay District. The property will be replatted as a single lot.
Lot 7, Block 8, Josephine Pankey 3rd Addition, contains an existing single-family
dwelling in the southwestern portion of the overall site. The remaining lots within
Block 8 are undeveloped. There is a mixture of zoning and uses surrounding the
property.
The applicant proposes to develop the 2.50 acre site to contain two (2) buildings
8,622 square feet in area (approximately 4,311 square feet in area for each
building). One (1) building will be constructed in the western portion of the site,
the second building will be constructed in the eastern portion of the site.
Two (2) access drives are proposed from Cantrell Road. The proposed layout
appears to provide ample room for interior traffic flow and maneuverability of
vehicles on the property.
The buildings will not exceed thirty-five (35) feet in height.
The site plan, for both proposed buildings, shows front building setbacks of one
hundred (100) feet from Cantrell Road, over forty (40) foot rear setbacks and
approximately twenty (20) foot setbacks from the east and west property lines.
The proposed restaurant use will operate seven (7) days a week, from 5:00am to
midnight.
The applicant provided alternative uses that would be possible or considered in
addition to fast food restaurants:
Coffee Shop
Bank
Pharmacy
Dry Cleaner
Car Wash
Donut Shop
Medical Clinic
Auto Service Center (limited to drive-thru only)
And additional retail uses that could utilize a drive-thru
Typically, the City’s Zoning Ordinance would require eighty-six (86) total parking
spaces. The developer is providing ninety-two (92) total parking spaces that
include four (4) ADA parking spaces. Staff feels the proposed parking is sufficient
to serve the use.
December 14, 2024
ITEM NO.: 19 (Cont.) FILE NO.: Z-10106
9
A dumpster enclosure is shown in the rear of the parking lot along the south
property line. The dumpster area must be screened and comply with Section 36-
523 of the City’s Zoning Ordinance.
The applicant did not provide a sign plan at this time. All signage must comply
with Section 36-349 of the Chenal/Financial Center Overlay District.
All site lighting must be low-level and directed away from adjacent properties.
Staff is not supportive of the PCD rezoning based on the following:
1. Based on the City’s future Land Use Plan (LUP), staff fees that the proposed
development is not appropriate at this time. The proposed development will
encroach into the Pankey Community.
2. The proposed use, including alternative uses, will create very heavy, high traffic
commercial use and may create an adverse impact on the properties in the
area.
3. The location is next to the City of Little Rock’s Connor Park and the entrance
to the park is immediately east of the proposed entrance to the proposed PCD.
I. STAFF RECOMMENDATION:
Staff recommends denial of the PCD rezoning.