HomeMy WebLinkAboutS-1538-M ApplicationPLANNING COMMISSION REVIEW CENTRAL ARKANSAS WATER 22 November 2016 NAME TYPE ISSUE COMMENTS PVK DEVELOPMENT LOT C Z-5758-G All Central Arkansas Water requirements in SHORT -FORM POD effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually NAME TYPE ISSUE COMMENTS thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. PAP NAME TYPE ISSUE COMMENTS HALL DAVIDSON BUILDING Z-8873-A All Central Arkansas Water requirements in SHORT -FORM PCD effect at the time of request for water service must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. 3 NAME TYPE ISSUE COMMENTS R & T PROPERTIES SHORT- Z-3735-A FORM POD All Central Arkansas Water requirements in effect at the time of request for water service must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required_ If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. NAME TYPE ISSUE COMMENTS LITTLE ROCK PORT AUTHORITY Z-9184 COLLEGE STATION SPORTS COMPLEX LONG -FORM PID All Central Arkansas Water requirements in effect at the time of request for water service must be met. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. 5 NAME TYPE ISSUE COMMENTS WILDWOOD TRAILS LONG- Z-9183 All Central Arkansas Water requirements in FORM PD-R effect at the time of request for water service must be met. A water main extension will be needed to provide water service to this property. Please submit plans for water facilities to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities. Approval of plans by Central Arkansas Water, the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. This development will have minor impact on the existing water distribution system. Proposed water facilities will be sized to provide adequate pressure and fire protection. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain information regarding the required placement of the hydrant(s) and contact Central Arkansas Water regarding procedures for installation of the hydrant(s). A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. NAME TYPE ISSUE COMMENTS PVK DEVELOPMENT LOT B Z-5758-F All Central Arkansas Water requirements in SHORT -FORM POD effect at the time of request for water service must be met. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. 7 NAME TYPE ISSUE COMMENTS SMITH DEVELOPMENT REVISED Z-8310-B SHORT -FORM POD All Central Arkansas Water requirements in effect at the time of request for water service must be met. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. NAME FITTS AUTO EXPANSION LONG - FORM PCD TYPE ISSUE COMMENTS Z-6054-B All Central Arkansas Water requirements in effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. If there are facilities that need to be adjusted and/or relocated, contact Central Arkansas Water. That work would be done at the expense of the developer. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced. pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and NAME TYPE ISSUE COMMENTS approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. 10 NAME TYPE ISSUE COMMENTS HAYS DEVELOPMENT REVISED Z-7875-E All Central Arkansas Water requirements in SHORT -FORM POD effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to 11 NAME TYPE ISSUE COMMENTS discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. 12 NAME TYPE ISSUE COMMENTS GENESIS DATACOM SHORT- Z-9185 All Central Arkansas Water requirements in FORM PD-C effect at the time of request for water service must be met. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. A Capital Investment Charge based on the size of meter connection(s) will apply to this project in addition to normal charges. This fee will apply to all connections including metered connections off the private fire system. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to 13 NAME TYPE ISSUE COMMENTS discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow preventer shall be required. 14 NAME TYPE ISSUE COMMENTS ADVANCED AUTO SUBDIVISION S-1784 All Central Arkansas Water requirements in SITE PLAN REVIEW effect at the time of request for water service must be met. A water main extension will be needed to provide water service to this property. The Little Rock Fire Department needs to evaluate this site to determine whether additional public and/or private fire hydrant(s) will be required. If additional fire hydrant(s) are required, they will be installed at the Developer's expense. Please submit plans for water facilities and/or fire protection system to Central Arkansas Water for review. Plan revisions may be required after additional review. Contact Central Arkansas Water regarding procedures for installation of water facilities and/or fire service. Approval of plans by the Arkansas Department of Health Engineering Division and Little Rock Fire Department is required. Contact Central Arkansas Water regarding the size and location of the water meter. The facilities on -site will be private. When meters are planned off private lines, private facilities shall be installed to Central Arkansas Water's material and construction specifications and installation will be inspected by an engineer, licensed to practice in the State of Arkansas. Execution of Customer Owned Line Agreement is required. Due to the nature of this facility, installation of an approved reduced pressure zone backflow preventer assembly (RPZ) is required on the domestic water service. This assembly must be installed prior to the first point of use. Central Arkansas Water (CAW) requires that upon installation of the RPZA, successful tests of the assembly must be completed by a Certified Assembly Tester licensed by the State of Arkansas and approved by CAW. The test results must be sent to CAW's Cross Connection Section within ten days of installation and annually thereafter. Contact the Cross Connection Section at 377-1226 if you would like to discuss backflow prevention requirements for this project. Fire sprinkler systems which do not contain 15 NAME TYPE ISSUE COMMENTS additives such as antifreeze shall be isolated with a double detector check valve assembly. If additives are used, a reduced pressure zone backflow, preventer shall be required. GATEWAY TOWN CENTER LOT S-1538-M NO OBJECTIONS; All Central Arkansas 4 REPLAT Water requirements in effect at the time of request for water service must be met. STAGECOACH WEST II LONG- Z-5649 NO OBJECTIONS; All Central Arkansas FORM PCD Water requirements in effect at the time of request for water service must be met. 16 Public Works Review Comments Planning Commission Agenda Date: 12-15-16 Z File Number 5-1538-M Gateway Town Center Lot 4 Replat Board of Adjustment Bass Pro Parkway 1 With site development, provide design of street conforming to the Master Street Plan. Construct commercial street improvement to these streets including 5-foot sidewalks with planned development. The commercial street should be 36 ft in width with sidewalks on both sides. 2 All driveways shall be concrete aprons per City Ordinance. Show the proposed driveway locations for each lot. Driveway spacing on commercial streets is 250 ft between driveways and from street intersections and 125 ft from side property lines. 3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advance grading variance being requested to clear and grade the lots with construction of the street. 5 Storm water detention ordinance applies to this property. A regional detention facility is provided west of the subject property. 6 If disturbed area is I or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 7 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 8 A concrete apron is required to be provided at the intersection of the proposed private street and Bass Pro Parkway. 9 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 10 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 11 Provide the proposed street name. Street names and street naming conventions must be approved by Public Works. Contact Glenn Haley at (501) 371-4537. 12 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 13 Accessible pedestrian access should be provided within, to, and from the proposed subdivision from existing adjacent developments. Monday, November 21, 2016 Page 1 of 8 Z File Number 5-1784 Advanced Auto Subdivision Site Plan Review 1421/1505 Rebsamen Park Rd 1 Rebsamen Park Rd is classified on the Master Street Plan as a collector street. A dedication of right- of-way 30 feet from centerline will be required. 2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 3 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 4 Unloading of vehicles is not allowed within the public right-of-way. Show the maneuvering path of the delivery truck. 5 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Z File Number Z-3735-A R & T Properties POD 13100 Chenal Parkway 0 No comments Z File Number Z-5649-F Stagecoach West II PCD 10915 Stagecoach Rd required 1 Stagecoach Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of- way 45 feet from centerline will be required. 2 A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to construction in the floodplain. 3 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. 4 Show the proposed finish floor elevation of at least 1 ft above the base flood elevation. 5 hi accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25 foot wide drainage and access easement is adjacent to the floodway boundary. 6 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 7 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI. 8 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 9 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner association. Monday, November 21, 2016 Page 2 of 8 Z File Number Z-5758-F PVK Development Lot B POD office/warehouse NW corner Kanis Rd & Pride Valley Rd 1 Kanis Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2 Pride Valley Rd is classified on the Master Street Plan as a collector street. A dedication of right-of- way 30 feet from centerline will be required. 3 Right-of-way should be dedicated at Kanis Rd and Pride Valley Rd intersection for a 90 degree intersection. Previous approved plans showed the reconfiguration of the intersection. 4 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Kanis Rd including 5-foot sidewalks with planned development. The new back of curb should be located 29.5 ft from the centerline. The developer will be responsible for an overall striping plan with a turn lane(s) and possible construction of taper sections at the time of permitting. 5 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advanced grading variance being requested to advance grade beyond Lot B with construction of this project. 6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner. 7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 8 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 9 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 10 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 11 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 12 Pride Valley Rd should intersect Kanis Rd at a 90 degree angle in accordance with the previously approved plan. Z File Number Z-5758-G PVK Development Lot C POD NW of Kanis Rd and Pride Valley Rd 1 Kanis Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2 Pride Valley Rd is classified on the Master Street Plan as a collector street. A dedication of right-of- way 30 feet from centerline will be required. 3 Right-of-way should be dedicated at Kanis Rd and Pride Valley Rd intersection for a 90 degree intersection. Previous approved plans showed the reconfiguration of the intersection. Monday, November 21, 2016 Page 3 of 8 4 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Kanis Rd including 5-foot sidewalks with planned development. The new back of curb should be located 29.5 ft from the centerline. The developer will be responsible for an overall striping plan with a turn lane(s) and possible construction of taper sections at the time of permitting. 6 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advanced grading variance being requested to advance grade beyond Lot C. with construction of this project. 7 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner association. 8 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 9 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 10 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 11 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 12 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. 13 Pride Valley Rd should intersect Kanis Rd at a 90 degree angle in accordance with the previously approved plan. 14 The proposed south driveway location may create a left turn conflict. Show on the plan the location of the Keifer driveway on the east side of Kanis Rd. Z File Number Z-6054-B Fitts Auto Expansion PCD 8421 Stagecoach Rd 1 Stagecoach Rd is classified on the Master Street Plan as a principal arterial. Dedication of right-of-way to 55 feet from centerline will be required. 2 Sidewalks with appropriate handicap ramps are required to be installed along Stagecoach Rd and extend to the side property line in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. Sidewalk stops on southside of driveway today. 3 Obtain permits for improvements within State Highway right-of-way from AHTD, District VI. 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advanced grading variance being requested to grade future phases with construction of Phase 1? 5 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). Provide finished floor elevations and fill embankments or retaining walls. Monday, November 21, 2016 Page 4 of 8 6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or owner. 7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 8 A special Grading Permit for Flood Hazard Areas will be required per Sec. 8-283 prior to construction. 9 The minimum Finish Floor elevation of at least 1 ft above the base flood elevation is required to be shown on plat and grading plans. 10 In accordance with Section 31-176, floodway areas must be shown as floodway easements or be dedicated to the public. In addition, a 25 foot wide drainage and access easement is required adjacent to the floodway boundary. If property within the floodway should be zoned as Open Space. 11 Vehicle offloading within the public right-of-way is allowed. Provide the truck manuevering area on the site plan. 12 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Z File Number Z-7875-E Hays Development POD 13423 Kanis Rd 1 Kanis Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Kanis Rd including 5-foot sidewalks with planned development. The new back of curb should be located 29.5 ft from centerline. A payment should be made to the City in -lieu of widening of Kanis Road. The new driveway should be placed 29 ft from the centerline. 3 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. 5 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). 6 Storm water detention ordinance applies to this property. Show the proposed location for stormwater detention facilities on the plan. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or property owner association. 7 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 8 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 9 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. Monday, November 21, 2016 Page 5 of 8 10 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 11 In accordance with 3 1-2 10 (h)(12), access driveways running parallel to the street shall not create a four-way intersection within 75' of the future curb line of the street. 12 Provide a letter prepared by a registered engineer certifying the intersection sight distance at the intersection(s) comply with 2004 AASHTO Green Book standards. 13 Damage to public and private property due to hauling operations or operation of construction related equipment from a nearby construction site shall be repaired by the responsible party prior to issuance of a certificate of occupancy. Z File Number Z-8310-B Smith Development POD 7801 Cantrell Rd 1 A 20 feet radial dedication of right-of-way is required at the intersection of Watt St. and T Street. 2 Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior to occupancy. 3 The existing sidewalk adjacent to Watt St. should be extended to the sidewalk adjacent to Cantrell Z File Number Z-8873-A Hall Davidson Building PCD 0 No comments Z File Number Z-9183 Wildwood Trails PD-R 201 - 205 Capitol Ave S of 1900 Blk of Denny Road 1 Denny Rd is classified on the Master Street Plan as a minor arterial. If not already dedicated, a dedication of right-of-way 45 feet from centerline will be required. 2 With site development, provide design of street conforming to the Master Street Plan. Construct one-half street improvement to Denny Road including 5-foot sidewalks with planned development. The new back of curb should be located 29.5 ft from centerline. A left turn lane should be provided for left turns on Denny Road. Additional paving and striping maybe required beyond the side property lines for tapers. The posted speed is 45 mph. The left turn lane should provide 150 ft of stack and 270 ft lane tapers. 3 Temporary turnarounds are required to be constructed at the ends of phases of streets. 4 Per the Master Street Plan, Rosemary Loop is not a loop street connecting in the same street at 2 separate intersections and should be constructed to a residential street standard with a 26 ft street width and a 50 ft right-of-way and sidewalk from Rosemary Drive to the first intersection. 5 Sidewalks with appropriate handicap ramps are required to be constructed on Rosemary Drive in accordance with Sec. 31-175 of the Little Rock Code and the Master Street Plan. How many additional lots are proposed that access Rosemary Drive on the south end of the project? 6 Temporary turnarounds are required to be constructed at the ends of phases streets. Monday, November 21, 2016 Page 6 of 8 7 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Is an advanced grading variance being requested to advance grade future phases with other phases of construction? 8 Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e). Access to public drainage easements must be provided from the right-of-way and infrastructure installed within that easement. 9 Storm water detention ordinance applies to this property. Maintenance of the detention pond and all private drainage improvements is the responsibility of the developer and/or the property owner's association. 10 If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas Department of Environmental Quality prior to the start of construction. 11 At this time, boundary street improvements are required to be constructed on Denny Road for the portion of property still owned by Pulaski Academy and not a part of the preliminary plat in conformance with previous approvals. 12 Alteration of the water course will require approval from the Little Rock District of the US Army Corps of Engineers prior to start of work. 13 Street Improvement plans shall include signage and striping. Public Works must approve completed plans prior to construction. 14 Street lights are required by Section 31-403 of the LR code. Provide plans for approval to Traffic Engineering. Streetlights shall utilized Entergy's standard fixtures and poles. Street lights must be installed prior to platting/certificate of occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info. 15 Hauling of fill material on or off site over municipal streets and roads requires approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more information. 16 Per the Master Street Plan, parking is restricted to one side of the street on a 24 ft wide street. Show on the plan now and on the final plat and bill of assurance, the area along the street where parking is allowed. 17 The proposed median should not extend into the Denny Road right-of-way. The taper section down to standard roadway width should meet Green Book Standards of WS/60. It is estimated the taper length will be 150 ft. 18 Per the Master Street Plan, all residential developments shall include traffic calming measures on each street within the development. The plan should include traffic calming on Rosemary Drive. Z File Number Z-9184 LR Port Authority Sports Complex PID N of Sloan Dr. & W of Mauney Road 1 Show the location of the floodplain in relation to the subject property. 2 All driveways shall be concrete aprons per City Ordinance. 3 The finished floor of the restroom structure must be elevated above the base flood elevation as determined by a certified engineer or surveyor. 4 A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land clearing or grading activities at the site. Other than residential subdivisions, site grading and drainage plans must be submitted and approved prior to the start of construction. Monday, November 21, 2016 Page 7 of 8 Z File Number Z-9185 Genesis Datacom PD-C 13008 Lawson Rd 1 Lawson Rd is classified on the Master Street Plan as a minor arterial. A dedication of right-of-way 45 feet from centerline will be required. 2 Future building expansion will required the owner to provide design of street improvements to Lawson Rd conforming to the Master Street Plan. Construct one-half street improvement to Lawson Rd including 5-foot sidewalks. Monday, November 21, 2016 Page 8 of 8 To: Dana Carney, Zoning & Subdivision Manager Date: 11-16-16 Donna James, Zoning Monte Moore, Subdivision From: Curtis Richey / Mark Alderfer: Building Codes Building Code Comments: Z-5758-G 15000 Kanis Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.org or Mark Alderfer at 501.371.4875; malderfer@littierocic.org. Z-8873-A 201 --- 205 Capitol Avenue Project is a change in occupancy and is therefore subject to current building code requirements. Review and approval is required by Building Codes Division before occupancy takes place. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littleroek.oor Mark Alderfer at 501.371.4875; malderfer@littlerock.org. Z-3735-A 13100 Chenal Parkway Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.org or Mark Alderfer at 501.371.4875; maiderfer@littlerock.org. Z-9184 North side of Sloan Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.org or Mark Alderfer at 501.371.4875; malderfer@littlerock.org. Z-9183 Dennyand Gordon Roads NC Z-5758-F Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey littlerock.org or Mark Alderfer at 501.371.4875; malderfer iittlerock.org. Z-8310-B 7801 Cantrell Project is a change in occupancy and is therefore subject to current building code requirements. Review and approval is required by Building Codes Division before occupancy takes place. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@iittlerock.org or Mark Alderfer at 501.371.4875; malderfer@littlerock.org. Z-6054-B _8421 Stagecoach Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichev@iittigEgLk.org or Mark Alderfer at 501.371.4875; malderfer littlerock.or . Z-7875-E 13423 Kanis Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; criche littlerock.or or Mark Alderfer at 501.371.4875; malderfer littlerock.or . Z-9385 13008 Lawson Road Project is a change in occupancy and is therefore subject to current building code requirements. Review and approval is required by Building Codes Division before occupancy takes place. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichey@littlerock.org or Mark Alderfer at 501.371.4875; maiderfer@iittlerock.org. S-1784 1421/1505 Rebsamen Park Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; crichev@iittlerocl(.org or Mark Alderfer at 501.371.4875; malderfer littierock.or . S-1538-M Bass Pro Parkwa NC Z-5649-F 10915 Stagecoach Road Project is subject to full commercial plan review and approval prior to issuance of a building permit. For information on submittal requirements and the review process, contact a commercial plans examiner: Curtis Richey at 501.371.4724; criche littlerock.or or Mark Alderfer at 501.371.4875; malderfer littlerock.or . Regards, Curtis Richey Commercial Plans Examiner MEMORANDUM TO: DONNA JAMES, SUBDIVISION ADMINISTRATOR FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF THE NOV 22, 2016, SUBDIVISION COMMITTEE MEETING CC: DANA CARNEY, ZONING & SUBDIVISION MANAGER DATE: NOV 09, 2016 1. Bass Pro Parkway (S-1538-M No Comment 2. 1421/1501 Rebsamen Park Road S-1784 Site plan must comply with the City's minimal landscape and buffer ordinance requirements. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 3. 13100 Chenal Parkway Z-3735-A Site plan must comply with the City's minimal landscape and buffer ordinance requirements and the Chenal Overlay District. All vehicular use areas which were in existence prior to the effective date of the Landscape Ordinance may continue as non -conforming until such time a building permit is issued to rehabilitate a structure on the property exceeding (50) percent of current replacement cost of the structure. At such time (50) percent of the existing vehicular use area shall be brought into compliance and shall continue to full compliance on a graduated scale based on the percentage of rehabilitation cost. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 4. 10915 Stagecoach Road .Z-5649-F Site plan must comply with the City's minimal landscape and buffer ordinance requirements. A land use buffer will be required when an adjacent property has a dissimilar use of a more restrictive nature. As a component of all land use buffer requirements, opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. A minimum of seventy (70) percent of the land use buffer shall be undisturbed. Easements cannot count toward fulfilling this requirement. The plantings, existing and purposed, shall be provided within the landscape ordinance of the city, section 15-81. The property to the east and south is zoned R-2, a minimum buffer will be required at six (6) percent of the average depth of the lot. The maximum dimension required shall be fifty (50) feet in all instances. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of no less than three (3) feet within the required landscape area. Provide trees with an average linear spacing of no less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property. This strip shall be at least nine (9) feet wide. Provide trees with an average linear spacing of not less than thirty (30) feet within the perimeter planting strip. Provide three (3) shrubs or vines for every thirty (30) linear feet of perimeter planting strip. Landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building Trees shall be included in the interior vehicular landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. A landscape irrigation system shall be required for developments of one (1) acre or larger. The development of two (2) acres or more requires an approved landscape plan stamped with the seal of a registered landscape architect prior to the issuance of a building permit. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 5. 15000 Block of Kanis East of Road and Pride Valley Intersection (Z-5758-F) Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 6. 15000 Block of Kanis East of Road and Pride Valley Intersection Z-5758-G Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). For developments with more than one hundred fifty (150) parking spaces the minimum size of an interior landscape area shall be three hundred (300) square feet. Interior islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 7. 8421 Stagecoach Road (Z-6054-B Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (1/2) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). For developments with more than one hundred fifty (150) parking spaces the minimum size of an interior landscape area shall be three hundred (300) square feet. Interior islands must be a minimum of seven and one half (7 1 /2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building A land use buffer six (6) percent of the average width / depth of the lot will be required when an adjacent property has a dissimilar use of a more restrictive nature. The minimum dimension shall be nine (9) feet. As a component of all land use buffer requirements, opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. The plantings, existing and purposed, shall be provided within the landscape ordinance of the city, section 15-81. An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. The development of two (2) acres or more requires the landscape plan to be stamped with the seal of a Registered Landscape Architect. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 8. 13423 Danis load (Z-7875_E) Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Street buffers will be required at six (6) percent of the average depth of the lot. The minimum dimension shall be one-half (1/z) the full width requirement but in no case less than nine (9) feet. The maximum dimension required shall be fifty (50) feet. The average depth of the lot is two hundred and ninety (290) feet. A minimum seventeen (17) foot street buffer is required adjacent to the Kanis Road right-of-way. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7 1/2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. A land use buffer six (6) percent of the average width / depth of the lot will be required when an adjacent property has a dissimilar use of a more restrictive nature. A portion of the adjacent property to the east is zoned R-2. As a component of all land use buffer requirements, opaque screening, whether a fence or other device, a minimum of six (6) feet in height shall be required upon the property line side of the buffer. The plantings, existing and purposed, shall be provided within the landscape ordinance of the city, section 15-102. An irrigation system shall be required for developments of one (1) acre or larger. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 9. 7801 Cantrell Rd Z-8310-B Site plan must comply with the City's minimal landscape and buffer ordinance requirements. All vehicular use areas which were in existence prior to the effective date of the Landscape Ordinance may continue as non -conforming until such time a building permit is issued to rehabilitate a structure on the property exceeding (50) percent of current replacement cost of the structure. At such time (50) percent of the existing vehicular use area shall be brought into compliance and shall continue to full compliance on a graduated scale based on the percentage of rehabilitation cost. Existing vehicular use areas may continue as nonconforming until such time as a building permit is granted to enlarge or reconstruct a structure on the property exceeding ten (10) percent of the existing gross fl6or area. At such time ten (10) percent of the existing vehicular use area shall be brought into compliance with this chapter and shall continue to full compliance on a graduated scale. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 10.201 -205 Capital Avenue (Z-8873-A) Site plan must comply with the City's minimal landscape and buffer ordinance requirements and the Urban Use District. Any exiting street trees, landscape, or irrigation disturbed by construction shall be repaired or replaced before completion and final acceptance of the project. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 11. Denny and Gordon Roads S side of Denny (Z-9183) No Comment 12. N side of Sloan Drive, 0.3 miles west of Mauney Rd (Z-9184) Site plan must comply with the City's minimal landscape and buffer ordinance requirements. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). For developments with more than one hundred fifty (150) parking spaces the minimum size of an interior landscape area shall be three hundred (300) square feet. Interior islands must be a minimum of seven and one half (7 1 /2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every twelve (12) parking spaces. An automatic irrigation system to water landscaped areas shall be required for developments of one (1) acre or larger. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. 13. 13008 Lawson Road (Z-9185) No Comment To: Donna James Date: November 10, 2016 From: Captain Tony Rhodes / Captain John Hogue: Fire Marshal Comment for the following Locations: Z-5758-G 15000 Block of Kanis Full plan review Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-5758-F 15000 Block of Kanis Full plan review Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loaing Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 30' Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads., Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. 2-8873-A 201-205 Capitol Avenue Full plan review Maintain Access: Fire H d ra nts. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loadin Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 30" Tall Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire HVdrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-3735-A 13100 Chenal Park Full plan Review Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-9184 North side of Sloan Drive Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. npnrl Fnrlc_ Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-9183 Denny and Gordon Road Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol- 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Dead Ends. Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. One- or Two -Family Residential Developments. As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or Two -Family dwelling residential developments. Developments of one- or two-family dwellings where the number of dwelling units exceeds 30 shall be provided with two separate and approved fire apparatus access roads, and shall meet the requirements of Section D104.3. Exceptions: Where there are more than 30 dwelling units on a single public or private fire apparatus access road and al dwelling units are equipped throughout with an approved automatic sprinkler system in accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall not be required. 2. The number of dwelling units on a single fire apparatus access road shall not be increased unless fire apparatus access roads will connect with future development, as determined by the fire code official. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-8310-B 7801 Cantrell Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-6054-B 8421 Stagecoach Road Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loadin Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments— 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 30' Tall Buildings -Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Gates Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing the fire apparatus access roads shall comply with all of the following criteria: 1. Minimum gate width shall be 20 feet. 2. Gates shall be of swinging or sliding type. 3. Construction of gates shall be of material that allow manual operation by one person. 4. Gate components shall be maintained in an operable condition at all times and replaces or repaired when defective. 5. Electric gates shall be equipped with a means of opening the gate by fire department personnel for emergency access. Emergency opening devices shall be approved by the fire code official. 6. Manual opening gates shall not be locked with a padlock or chain and padlock unless they are capable of being opened by means of forcible entry tools or when a key box containing the keys to the lock is installed at the gate location. 7. Locking device specifications shall be submitted for approval \by the fire code official 8. Electric gate operators, where provided, shall be listed in accordance with UL 325. 9. Gates, intended for automatic operation shall be designed, constructed and installed to comply with requirements of ASTM F 2200. Fire H drants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-7875-E No Comment Z-9185 13008 Lawson Road Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section 13103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. S-1784 1421/1505 Rebsamen Park Road Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loading Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. 30' Tall Buildin S - Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Dead Ends_ Maintain fire apparatus access roads at dead end locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be provided with width and turnaround provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access roads. Fire hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. S-1538-M Bass Pro Parkway Maintain Access: Fire Hydrants. Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet, exclusive of shoulders. Grade Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade except as approved by the fire chief. Loadin Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department apparatus by way of an approved fire apparatus access road with an asphalt, concrete or other approved driving surface capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds. Commercial and Industrial Developments — 2 means of access. - Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or facilities exceeding 30 feet or three stories in height shall have at least two means of fire apparatus access for each structure. Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities having a gross building area of more than 62,000 square feet shall be provide with two separate and approved fire apparatus access roads. Exception: Projects having a gross building area of up to 124,000 square feet that have a single approved fire apparatus access road when all building are equipped throughout with approved automatic sprinkler systems. D104.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one half of the length of the maximum overall diagonal dimension of the lot or area to be served, measured in a straight line between accesses. 30' all Buildings - Maintain aerial fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1— D105.4 D105.1 Where Required. Where the vertical distance between the grade plane and the highest roof surface exceed 30', approved aerial fire apparatus access roads shall be provided. For the purposes of this section the highest roof surfaces shall be determined by measurement to the eave of a pitched roof, the intersection of a roof to the exterior wall, or the top of the parapet walls, whichever is greater. D105.2 Width. Aerial fire apparatus access roads shall have a minimum unobstructed with of 26', exclusive of shoulders, in the immediate vicinity of the building or portion thereof. D105.3 Proximity to building. At least one of the required access routes meeting this condition shall be located within a minimum of 15 feet and a maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the building. The side of the building on which the aerial fire apparatus access road is positioned shall be approved by the fire code official. D105.4 Obstructions. Overhead utility and power lines shall not be located over the aerial fire apparatus access road or between the aerial fire apparatus road and the building. Other obstructions shall be permitted to be places with the approval of the fire code official. Fire Hydrants Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code. Section C101— C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number and Distribution of Fire Hydrants as per Table C105.1. Z-5649-F 10915 Stagecoach Road No Comment Regards, Captain Rhodes and Captain Hogue Office: 918-3710 �Enteigy November 11, 2016 City of Little Rock Department of Planning and Development ATTN: Ms. Donna James, AICP 723 West Markham Street Little Rock, AR 72201-1334 Entergy Arkansas Inc. #9 Entergy Court Little Rock, AR 72211 RE: Entergy comments related to Planning and Zoning items for the December 15`h Meeting Ms. James, Please find below Entergy's comments related to the items received from the Department of Planning and Development last week. The request letter said to have the comments back to you by November 18th, 2016. • Hall Davidson Building — 201-205 Capitol Ave: Z-8873-A Entergy does not object to this proposal. Entergy is aware of this project and has already been in communication with the developer. This particular project is located in an area served by Entergy's underground network and as such will need to be served by special, network equipment. This discussion has already begun. • R&T Properties —13100 Chenal Parkway: Z-3735-A Entergy does not object to this proposal. Service is already being provided to this structure. Power lines currently exist along Chenal Parkway and on the west side of this property. Contact Entergy in advance to discuss any changes to electrical service requirements, or adjustments to existing facilities (if any) as this project proceeds. • LR Port Authority College Station Sports Complex — N side of Sloan, 0.3 mi. west of Mauney Rd.: Z-9184 Entergy does not object to this proposal. An existing three phase, power line exists along Sloane Drive on the south side of this property. It does not appear to be in conflict with the proposed development. Care must be used to maintain proper clearances in the construction of the entry drive to this property as it will be constructed underneath the existing power line. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. • Wildwood Trails — Denny and Gurdon Roads, S. side of Denny, 1900 block: Z-9183 Entergy Distribution does not object to this proposal. An existing three phase, distribution power line exists along Denny Road on the north side of this proposed development site. There do not appear to be any conflicts with existing distribution, electrical facilities. However, there needs to be some contact between the developer and Entergy's Transmission Department as there is a proposed road crossing on the Transmission Line easement on the south side of the property. Transmission lines are highly regulated and may have stringent requirements for right of way access and line crossing. Contact Entergy Distribution in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. • PVK Development Lot B —15000 block of Kanis, east of Kanis and Pride Valley: Z-5758-F Entergy does not object to this proposal. An existing three phase, power line exists along the south side of Kanis Road in front of this property. As Kanis Road is widened at this location then this power line will likely need to be relocated further south onto the property and relocation costs may be involved. Also, care must be used to maintain proper clearances in the construction of the entry drive to this property as it will be constructed underneath the existing power line. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. s PVK Development Lot C —15000 block of Kanis, east of Kanis and Pride Valley: Z-5758-G Entergy does not object to this proposal. An existing three phase, power line exists along the south side of Kanis Road in front of this property. As Kanis Road is widened at this location then this power line will likely need to be relocated further south onto the property and relocation costs may be involved. Also, care must be used to maintain proper clearances in the construction of the entry drive to this property as it will be constructed underneath the existing power line. Contact Entergy in advance to discuss future service requirements, new facilities locations and adjustments to existing facilities (if any) as this project proceeds. ■ Smith Development — 7801 Cantrell Rd: Z-8310-B Entergy does not object to this proposal. Service is already being provided to this structure. Power lines currently exist along Cantrell Road and on the west side of this property. Contact Entergy in advance to discuss any changes to electrical service requirements, or adjustments to existing facilities (if any) as this project proceeds. • Fitts Auto Expansion — 8421 Stagecoach Rd.: Z-6054-B Entergy does not object to this proposal. An existing three phase, overhead power line exists along Stagecoach Road to the north and another one exists along the western side of the property. They do not appear to be in conflict with the proposed development. Contact Entergy in advance to discuss future service requirements, new facilities locations/extensions and adjustments to existing facilities (if any) as this project proceeds. • Hays Development —13423 Kanis Rd.: Z-7875-E Entergy does not object to this proposal. Service is already being provided to an existing structure on this property. Power lines currently exist along Kanis Road and on the north side of this property. Contact Entergy in advance to discuss future service requirements, new facilities locations/extensions and adjustments to existing facilities (if any) as this project proceeds. Genesis Datacom —13008 Lawson Rd.: Z-9185 Entergy does not object to this proposal. Service is already being provided to the existing structures on this property. Power lines currently exist along Lawson Road and on the west side of this property. Contact Entergy in advance to discuss future service requirements, new facilities locations/extensions and adjustments to existing facilities (if any) as this project proceeds. Advanced Auto Subdivision—1421/1505 Rebsamen Park Rd.: S-1784 Entergy does not object to this proposal. A three phase, overhead electrical line runs along the west edge of this property along Rebsamen Park Road and a single phase, overhead line extends into the property from west to east in about the center of the development. There do not appear to be any existing conflicts with Entergy facilities on this property. There do appear to be communication conductors of some sort which extend toward the location of the proposed structures. Contact Entergy in advance to discuss future service requirements, new facilities locations/extensions and adjustments to existing facilities (if any) as this project proceeds. Gateway Town Center Lot 4 Replat — Bass Pro Parkway: S-1538-M Entergy does not object to this proposal. A three phase, underground electrical line runs along the western edge of this property. There do not appear to be any existing conflicts with Entergy facilities on this property. Service to any of the proposed lots contained in the replat of Lot 4 will require quite a bit of prework and discussion. Contact Entergy in advance to discuss future service requirements, new facilities locations/extensions and adjustments to existing facilities (if any) as this project proceeds. Stagecoach West II —10915 Stagecoach Rd.: Z-5649-F Entergy does not object to this proposal. A three phase, overhead electrical line runs along the north side of Stagecoach Road, and a single phase, overhead line crosses the road to the approximate location of this development. There do not appear to be any existing conflicts with Entergy facilities on this property. Contact Entergy in advance to discuss future service requirements, new facilities locations/extensions and adjustments to existing facilities (if any) as this project proceeds. If you need further assistance you may call me at 501-954-5158 or e-mail me at bneumei@entergy.com. Sincerely, Bernard Neumeier Region Engineering Supervisor Entergy Arkansas, Inc. Rock Region LV,A METRE Rock Region METRO Planning and Subdivision Review Memo To: City of Little Rock Planning and Development, Donna James, Monte Moore, Dana Carney From: Kathleen Lambert, Sr. Transit Planner Date: November 16, 2o16 Re: Subdivision Reviews December 15, 2o16 hearing i) Z-5748-F PVK Planned Development Lot B—i5000 Block of Kanis Rd. a) Location is not currently served by METRO but is on our long range plans. We recommend continuation of pedestrian infrastructure for access to the transit system. 2) Z-83io-B Smith Development 78oz Cantrell Rd. a) Location is currently served by METRO, route i, nearby at Cantrell Rd. and Mississippi St. We recommend closing old curb cuts which are not accessible or are too close to intersections per current regulations. By closing and consolidating curb cuts it will enhance pedestrian and disabled access to the facility. 3) Z-9183 Wildwood Trails PD-R; zgoo Denny and Gordon Roads a) Location is not currently served by METRO but is on our long range plans. We recommend continuation of pedestrian infrastructure for access to the transit system. 4) Z-9i84 Little Rock Port Authority College Station Sports; Sloan & Mauney Drives a) Location is currently served by METRO on route 20. Both cyclists and pedestrians use the road shoulders in this industrial area as a sidewalk. Provide sidewalk from road shoulder to the interior of ballfield facility for access by pedestrians and cyclists. 901 Maple Street, North Little Rock 72214 rrmetro.org 501-375-6717p 6 5) Z-3735-A R&T Properties; 13003. Chenal Parkway a) Location is not currently served by METRO but is on our long range plans. We recommend continuation of pedestrian infrastructure for access to the transit system. Also provide pedestrian link through parking areas for access from the street to businesses and services. 6) Z-5758-G PVK Development POD; i5000 Block of Kan is Rd. a) Location is not currently served by METRO but is on our long range plans. We recommend continuation of pedestrian infrastructure for access to the transit system. 7) Z-8873-A Hall Davidson Building- 201-205 Capital Ave a) Location is served by METRO via several routes and is located along a main route in the system. In order to serve riders more efficiently we recommend removing (i) parking space at Capital Ave and Louisiana St on either side of the corner. Parking spaces are too close to the corner to be able to board passengers without the riders having to walk between cars to board. 8) Z-9i85 Genesis Datacom PD-C;1.3oo8 Lawson Rd. a) Location is not currently served by METRO but is on our long range plans. We recommend continuation of pedestrian infrastructure for access to the transit system. 9) Z-7875-E Hays Development POD;13423 Kan is Road a) Location is not currently served by METRO but is on our long range plans. We recommend continuation of pedestrian infrastructure for access to the transit system. zo) Z-6o54-B Fitts Auto Expansion PCD; 8423. Stagecoach Rd. a) Location is currently served by METRO on nearby route 23. Provide sidewalks along highway 5 for access to the transit route in accordance to current development requirements. zz) S-i784 Advanced Auto Subdivision; 1421/3.505 Rebsamen Park Road a) Location is served by METRO on route 2. Continue pedestrian infrastructure for access to the transit routes and other recreational amenities in the neighborhood. 3 12) S-i538-M Gateway Town Center; Bass Pro Parkway a) Location is currently served by METRO on route 23. Provide sidewalks along Bass Pro Parkway for access to the transit route in accordance to current development requirements. 13) Z-5649-F Stagecoach West II PCD; 3.ogi5 Stagecoach Road a) Location is currently served by METRO on nearby route 23. Provide sidewalks along Highway 5 for access to the transit route in accordance to current development requirements. Little Rock Wastewater Comments Project Number S-1538-M Project Name Project Type Gateway Town Center Lot 4 Replat -create 7 lots Replat Project Number S-1784 Project Name Project Type Advanced Value Automotive Subdivision, Multi-bldg site plan Project Number Z-3735-A Project Name R&T Properties Project Number Z-5649-F Project Name Stagecoach West II Project Number Z-5758-F Project Name PVK Development Lot B Project Type Planned Office Development Comment Made Sewer main extension required with easements if new sewer service is required for this project. Comment Made Sewer main extension required with easements if new sewer service is required for this project. Comment Made Sewer Available to this site. EAD approval required if food prep on site. Project Type Comment Made Planned Development Commercial Sewer main extension required with easements if new sewer service is required for this project. Project Type Planned Office Development Project Number Z-5758-G Project Name Project Type PVK Development Lot C Planned Office Development Project Number Z-6054-B Project Name Fitts Auto Expansion Project Number Z-7875-E Project Name Project Type Planned Development Commercial Project Type Comment Made Sewer main extension required with easements if new sewer service is required for this project (there is an existing approved project at LRW.) Comment Made Sewer main extension required with easements if new sewer service is required for this project (there is an existing approved project at LRW.) Comment Made Sewer main extension required with easements if new sewer service is required for this project. Comment Made Tuesday, November 15, 2016 Page 1 of 2 Riley Hays Roofing Planned Office Development Development Project Number Z-8310-B Project Name Project Type Smith Development Planned Office Development Project Number Z-8873-A Project Name Project Type Hall Davidson Building Planned Development Commercial Project Number Z-9183 Project Name Project Type Wildwood Trails Planned Development Residential Project Number Z-9184 Project Name Project Type LRPA College Station Planned Development Industrial Sports Complex Project Number Z-9185 Project Name Project Type Genesis Datacom Planned Development Commercial Sewer Available to this site. EAD approval req'd if sand/oil trap on site Comment Made Sewer Available to this site. Comment Made Sewer Available to this site. Capacity Fee analysis required if multi -family residential. Comment Made Sewer main extension required with easements if new sewer service is required for this project. Zero Capacity Fee analysis required. Comment Made Sewer main extension required with easements if new sewer service is required for this project. Comment Made Outside Service Boundary - No Comment. Tuesday, November 15, 2016 Page 2 of 2 Z-3735-A Address: 13100 Chenal Parkway Planning Division: This request is located in Chenal Planning District. The Land Use Plan shows MX (Mixed Use). This category provides for a mixture of residential, office and commercial uses to occur. A Planned Zoning District is required if the use is entirely office or commercial or if the use is a mixture of the three. The applicant has applied for a rezoning from 0-3 (General Office District) to POD (Planned Office Development) to allow a consignment store in the same building in addition to existing office uses. This request is within the Chenal Design Overlay District. Master Street Plan: To the south of the property is Chenal Parkway and it is shown as Principal Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Chenal Parkway. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity. Z-5649-F Address: 10915 Stagecoach Road Planninq Division: This request is located in Otter Creek Planning District. The Land Use Plan shows Mixed Office and Commercial (MOC) for this property. This category provides for a mixture of office and commercial uses to occur. Acceptable uses are office or mixed office and commercial. A Planned Zoning District is required if the use is mixed office and commercial. The applicant has applied for a rezoning from R-2 (Single Family District) to PCD (Planned Commercial Development) to allow auto sales on the property. Master Street Plan: To the north of the property is Stagecoach Road and it is shown as Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Stagecoach Road since it is a Minor Arterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Stagecoach Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Z-5758-F Address: 15000 Block of Kanis Road, NWC of Kanis Road and Pride Valley Road Intersection Planning Division: This request is located in Ellis Mountain Planning District. The Land Use Plan shows Suburban Office (SO) for this property. The suburban office category shall provide for low intensity development of office or office parks in close proximity to lower density residential areas to assure compatibility. A Planned Zoning District is required. The applicant has applied for a rezoning from PCD (Planned Commercial Development) to POD (Planned Office Development) to allow office and warehouse uses. Master Street Plan: To the northeast of the property is Kanis Road and it is a Minor Arterial, to the south of the property is Pride Valley and it is a Collector on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis Road since it is a Minor Arterial. The primary function of a Collector Road is to provide a connection from Local Streets to Arterials. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity. Z-5758-G Address: 15000 Block of Kanis Road, NWC of Kanis Road and Pride Valley Road Intersection Planning Division: This request is located in Ellis Mountain Planning District. The Land Use Plan shows Suburban Office (SO) for this property. The suburban office category shall provide for low intensity development of office or office parks in close proximity to lower density residential areas to assure compatibility. A Planned Zoning District is required. The applicant has applied for a rezoning from PCD (Planned Commercial Development) to POD (Planned Office Development) to allow development of an office use. Master Street Plan: To the northeast of the property is Kanis Road and it is a Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis Road since it is a MinorArterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity Z-6054-B Address: 8421 Stagecoach Road Planninq Division_ This request is located in the Otter Creek Planning District. The Land Use Plan shows Mixed Office and Commercial (MOC) and Parks/Open Space (PK/OS) for this property. Mixed Office and Commercial category provides for a mixture of office and commercial uses to occur. Acceptable uses are office or mixed office and commercial. A Planned Zoning District is required if the use is mixed office and commercial. Parks/Open Space category includes all public parks, recreation facilities, greenbelts, flood plains, and other designated open space and recreational land. The applicant has applied for a rezoning from C-4 (Open Display Commercial District) to PCD (Planned Commercial District) to allow expansion of existing auto sales and future development of office/retail uses utilizing C-3 (General Commercial District) uses. Master Street Plan: To the north of the property is Stagecoach Road and it is shown as Principal Arterial on the Master Street Plan. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Stage Coach Road. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Stagecoach Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Z-7875-E Address: 13423 Kanis Road Planninq Division- This request is located in Ellis Mountain Planning District. The Land Use Plan shows Suburban Office (SO) for this property. The suburban office category shall provide for low intensity development of office or office parks in close proximity to lower density residential areas to assure compatibility. A Planned Zoning District is required. The applicant has applied for a revision of POD (Planned Office District) to allow the placement of a contractor's office within a new building. Master Street Plan: To the north of the property is Kanis Road and it is a Minor Arterial on,the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis Road since it is a MinorArterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity Z-8310-B Address: 7801 Cantrell Road Planning Division: This request is located in the West Little Rock Planning District. The Land Use Plan shows Mixed Office and Commercial (MOC) for this property. This category provides for a mixture of office and commercial uses to occur. Acceptable uses are office or mixed office and commercial. A Planned Zoning District is required if the use is mixed office and commercial. The applicant has applied for a revision of POD (Planned Office District) to add health studio spa as an allowable use. Master Street Plan: To the northwest of the property is Biscayne Drive and it is a Collector, to the northeast of the property is Cantrell Road and it is a Principal Arterial, to the southeast is Watt Street and it is a Local Street on the Master Street Plan. The primary function of a Collector Road is to provide a connection from Local Streets to Arterials. A Principal Arterial is to serve through traffic and to connect major traffic generators or activity centers within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Cantrell Road. The primary function of a Local Street is to provide access to adjacent properties. Local Streets that are abutted by non-residential zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets". A Collector design standard is used for Commercial Streets. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: There are no bike routes shown in the immediate vicinity. Z-8873-A Address: 201-205 W Capitol Avenue Planning Division: This request is located in Downtown Planning District. The Land Use Plan shows MXU (Mixed Use Urban). Mixed Use Urban category provides for a mix of residential, office and commercial uses not only in the same block but also within the same structure. This category is intended for older "urban" areas to allow dissimilar uses to exist, which support each other to create a vital area. Development should reinforce the urban fabric cresting a 24-hour activity area. The applicant has applied for a revision of PCD (Planned Commercial District) to increase the density to allow multifamily uses in the building. Master Street Plan: To the north of the property is W. Capitol Avenue and to the east of the property is S. Louisiana Street and they are both shown as Collectors on the Master Street Plan. The primary function of a Collector Road is to provide a connection from Local Streets to Arterials. These streets may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Louisiana Street. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Z-9183 Address: South side of Denny Road in the 19000 Block Planning Division: This request is located in Burlingame Valley Planning District. The Land Use Plan shows RL (Residential Low). Residential Low category provides for single family homes at densities not to exceed 6 units per acre. Such residential development is typically characterized by conventional single family homes, but may include patio or garden homes and cluster homes, provided that the density remain less than 6 units per acre. The applicant has applied for a rezoning of PDR (Planned Development Residential) to allow the development of attached and detached single family houses and it meets the RL density requirements. Master Street Plan: To the north of the property is Denny Road and it is shown as a Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Denny Road since it is a Minor Arterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Denny Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Z-9184 Address: North Side of Sloan Drive, 03 miles west of Mauney Road Planning Division: This request is located in Port Planning District. The Land Use Plan shows I (Industrial). The industrial category encompasses a wide variety of manufacturing, warehousing research and development, processing, and industry related office and service activities. Industrial development typically occurs on an individual tract basis rather than according to an overall development plan. The applicant has applied for a rezoning from 1-3 (Heavy Industrial District) to PID (Planned Industrial Development) to add sports complex as an allowable use. Master Street Plan: To the south of the property is Sloan Drive and it is shown as a Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is.to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Sloan Drive since it is a Minor Arterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Sloan Drive. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Z-9185 Address: 13008 Lawson Road Planning Division: This request is located in Ellis Mountain Planning District. The Land Use Plan shows RL (Residential Low). Residential Low category provides for single family homes at densities not to exceed 6 units per acre. Such residential development is typically characterized by conventional single family homes, but may include patio or garden homes and cluster homes, provided that the density remain less than 6 units per acre. The applicant has applied for a rezoning from R- 2 (Single Family District) to PDC (Planned Development Commercial) for Genesis Datacom an existing non -conforming use to a conforming use. Master Street Plan: To the south of the property is Lawson Road and it is shown as a Minor Arterial on the Master Street Plan. A Minor Arterial provides connections to and through an urban area and their primary function is to provide short distance travel within the urbanized area. Entrances and exits should be limited to minimize negative effects of traffic and pedestrians on Lawson Road since it is a Minor Arterial. This street may require dedication of right-of-way and may require street improvements for entrances and exits to the site. Bicycle Plan: A Class II Bike Lanes are shown along Lawson Road. Bike Lanes provide a portion of the pavement for the sole use of bicycles. Area Zoning City of Little Rock Planning & Development 6 ,., FOR ! � tr.Lim_=., Case: S-1538-M Location: Bass Pro Parkway Ward: 7 N PD: 16 CT:41.03 0 200 400 TRS: T1 S R13W 4 Feet Sketch City of Little Rock Planning &Development Case No: S-1538-M Name: Gateway Town Center Lot 4 Replat Location: Bass Pro Parkway and Bass Pro Drivel Issue: Replat Create 7 Lots N A City of Little Rock L�mtDepartment of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 December 19, 2016 McGetrick Engineering P.O. Box 30441 Little Rock, AR 72260 Re: 5-1538-M - Gateway Town Center Lot 4 Replat, located on Bass Pro Parkway and Bass Pro Drive Dear Sirs: This is to advise you that in connection with your request concerning the above referenced file number the following action was taken by the Planning Commission at its meeting on December 15, 2016: X Approved with conditions. Recommended approval with conditions. Recommended approval as submitted. Denied your request as submitted. Deferred to the _Meeting. Other: If you have any questions please do not hesitate to contact me at 371-6821. Respectfully, Donna James, AICP Subdivision Administrator James, Donna From: MCGETRICK MCGETRICK <mcgetrick2@sbcglobal.net> Sent: Thursday, December 15, 2016 9:18 AM To: James, Donna Subject: Fw: Bass Pro Shops Little Rock - New England Development cross -access permission Donna, Please see the forwarded letter from Mike Barelli to the Bass Pro regarding their cross - connection. Pat On Wednesday, December 14, 2016 9:37 AM, Robert B. Stockdale <RBStockdale@basspro.com> wrote: Pat, Please see correspondence below regarding permission to cross -connect with the outlet mall. Let me know if this will satisfy the city or if something else is required. The note is addressed to Mike Dunham, head of Real Estate at Bass Pro Shops. Thank you. Bob On Dec 13, 2016, at 5:14 PM, Barelli, Michael <Mbarelli@nedevelopment.com> wrote: Mike, You had asked us for permission to make a cross -connection between your Little Rock property in the location shown on the attached "2016-08-16 outparcel plan -FLAT" PDF. As discussed, we are willing to grant that permission. And to streamline the process, based on our review of the Gateway Town Center Declaration, we have determined that your planned connection does not require an easement between NED and Bass Pro Shops. Here's the specific language that we are relying upon from Section 2.1 of the Declaration: "Ingress and Egress: During the term of this Declaration, the Declarant hereby establishes for the use of itself, all Owners, their respective successors and assigns, and their respective Permittees in common with others entitled to use the same, a perpetual non-exclusive easement for the ingress, egress and passage of pedestrians and of passenger, service and delivery vehicles over and across those portions of a Lot from time to time used as a driveway or drive aisle as the same may from time to time be constructed, repaired and maintained for such use (a "Driveway Area"), provided however, such easement expressly excludes and this Declaration prohibits cross -parking as between the lots except by written agreement of the Owners of such Lots." As a next step, let's start working toward a letter agreement between NED and Bass Pro Shops that talks about where the connection will specifically be made and how the grading and landscaping will work in relation to the intersection with NED's parking lot. Could you prepare a plan showing these items so we can review? I have attached a CAD file of our site plan for your team's convenience. Our desire is for the driveway to align with our parking lot drive aisles. Thanks in advance — we're looking forward to working on this with you. Best, Mike Michael Barelli Vice President T 617.243.7812 F 617.243.7385 M 347.324.7926 M BarelligN EDevelopment. com<mailto: M BarelliCaD-N EDevelop mPnt r.nm> New England Development Preferred locations. Compelling opportunities. 75 Park Plaza Boston, Massachusetts 02116 NEDevelopment.com<http://www.nedevelopment.com/> 2 McGetrick & McGetrick, Inc. Civil Engineering November 28, 2016 Donna James, Subdivision Administrator City of Little Rock, Arkansas Planning and Development 723 West Markham Little Rock, AR 72201-1334 Re: Bass Pro Lot 4 Replat Dear Ms. James: In response to the comments from the Little Rock Subdivision Committee we have the following responses. Planning Staff Comments: The project will be developed in a single phase. I have requested a letter from the adjacent property owner concerning the ability to access the private drive located on the Outlets of Little Rock site. I have indicated the building lines on the revised plat. I have also shown the driveway locations that are approved Little Rock Public Works. If you have any questions regarding the information provided, please feel free to contact me. Sincerely, e ick & McGetrick, Inc. Patrick M. McGetrick, P.E. PM:cmc 116o1 Bass Pro Parkway Little Rock, AR 72210 501455-8899 501-455-0525 mcgetrick2@sbeglobal.net James, Donna From: Floriani, Vince Sent: Friday, November 25, 2016 9:06 AM To: 'MCGETRICK MCGETRICK'; James, Donna Subject: FW: GATEWAY DRIVES Pat, We are good with that plan. Vince Sent using OWA for iPhone From: Henry, Bill Sent: Thursday, November 24, 2016 5:22:54 PM To: Floriani, Vince Subject: Re: GATEWAY DRIVES We can live with that. William Henry, PE Traffic Engineering Manager City of Little Rock Public Works 621 S Broadway St Little Rock, AR 72201 501-379-1816 Sent from my iPhone On Nov 23, 2016, at 1:44 PM, Floriani, Vince <VFlorianinlittlerock.gov> wrote: Bill, What do you think about the revised driveway locations? Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: MCGETRICK MCGETRICK[ma !Ito:mcgetrick2@sbcgloba1.net] Sent: Wednesday, November 23, 2016 1:22 PM To: Floriani, Vince Subject: Re: GATEWAY DRIVES Vince, I revised the plan with 150' at the intersection. It reduces the distance on the second drive 1 to 190' feet instead of 240' feet. the third drive is still 250'. See what you think. Pat On Wednesday, November 23, 2016 11:32 AM, "Floriani, Vince" <VF1orianiCo7littlerock.gav> wrote: Pat, Traffic Engineering commented that the driveways on the private street closest to the Bass Pro Parkway ROW should be placed no closer than 150 ft from the Bass Pro Parkway ROW. Along the private street, the City code requires a driveway spacing of at least 250 ft. Since this distance cannot be met and provide adequate access, Traffic Engineering requests the most spacing as possible between driveways. Please contact the owner and adjust your driveway locations and we can discuss further. Thanks, Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: MCGETRICK MCGETRICK [mailto:mcgetrick2-sbcglobal.net] Sent: Tuesday, November 22, 2016 3:54 PM To: Floriani, Vince Subject: GATEWAY DRIVES Here you go. <bass pro 2 11-22-2016 2b.pdf> A w 0 LC) o J James, Donna From: Floriani, Vince Sent: Wednesday, November 23, 2016 11:32 AM To: MCGETRICK MCGETRICK <mcgetrick2@sbcglobal.net> (mcgetrick2@sbcglobal.net) Cc: Henry, Bill; James, Donna Subject: FW: GATEWAY DRIVES Attachments: bass pro 2 11-22-2016.pdf Pat, Traffic Engineering commented that the driveways on the private street closest to the Bass Pro Parkway ROW should be placed no closer than 150 ft from the Bass Pro Parkway ROW. Along the private street, the City code requires a driveway spacing of at least 250 ft. Since this distance cannot be met and provide adequate access, Traffic Engineering requests the most spacing as possible between driveways. Please contact the owner and adjust your driveway locations and we can discuss further. Thanks, Vince Floriani, P.E. Little Rock Public Works -Civil Engineering 701 W. Markham St. Little Rock, Arkansas 72201 501-371-4817 From: MCGETRICK MCGETRICK [mailto:mcgetrick2@sbcglobal.net] Sent: Tuesday, November 22, 2016 3:54 PM To: Floriani, Vince Subject: GATEWAY DRIVES Here you go. City of LiMe Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND November 8, 2016 Bentley Court POA Christopher Henry P.O. Box 30934 Little Rock, AR 72260 REQUEST: Gateway Town Center Lot 4 Replat S-1538-M a reguest to replat a previously platted lot allowing for the creation of 7-lots ranging in size from 2-acres to 14-acres_ GENERAL LOCATION OR ADDRESS: Bass Pro Drive and Bass Pro Parkway OWNED BY/APPLICANT: Bass Pro Outdoor World LLC — Pat McGetrick, McGetrick Enqineerinq Agent 501.455.8899 NOTICE IS HEREBY GIVEN THAT an application for a Replat of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L.R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on December 15, 2016 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND November 8, 2016 Chateaus on Stagecoach Christye Walker 59 Chateaus Lane Little Rock, AR 72210 REQUEST: Gateway Town Center Lot 4 Replat S-1538-M , a request to replat a reviousl latted lot allowing for the creation of 7-lots ranging in size from 2-acres to 14-acres. GENERAL LOCATION OR ADDRESS: Bass Pro Drive and Bass Pro Parkway OWNED BY/APPLICANT: Bass Pro Outdoor World LLC — Pat McGetrick McGetrick Enginee�riinc Agent 501.455.8899 _ NOTICE IS HEREBY GIVEN THAT an application for a Replat of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L.R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on December 15, 2016 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development City of Little Rock L�wtDepartment of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND November 8, 2016 Otter Creek Home Owners Association Teresa Kroger 14000 Otter Creek Parkway Little Rock, AR 72210 REQUEST: Gateway Town Center Lot 4 Replat S-1538-M a request to replat a previously platted lot allowing for the creation of 7-lots ranging in size from 2-acres to 14-acres. GENERAL LOCATION OR ADDRESS: Bass Pro Drive and Bass Pro Pa OWNED BY/APPLICANT: Bass Pro Outdoor World LLC — Pat McGetrick. McGetrick Enaineerina Aaent 501.455.8899 NOTICE IS HEREBY GIVEN THAT an application for a Replat of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L.R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on December 15, 2016 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development City of Little Rock Department of Planning and Development Planning 723 West Markham Street Zoning and Little Rock, Arkansas 72201-1334 Subdivision - Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF LAND November 8, 2016 South West Little Rock United for Progress Troy Laha 6602 Baseline Rd, Ste E Little Rock, AR 72209 REQUEST: Gateway Town Center Lot 4 Replat (S-1538-M), a request to replat a Previousiv platted lot allowing for the creation of 7-lots ranqinq in size from 2-acres to 14-acres. GENERAL LOCATION OR ADDRESS.- Bass Pro Drive and Bass Pro Parkway OWNED BY/APPLICANT- Bass Pro Outdoor World LLC — Pat McGetrick McGetrick Enqineerinq Aaent 501.455.8899 NOTICE IS HEREBY GIVEN THAT an application for a Replat of the above property has been filed with the Department of Planning and Development. A public hearing will be held by the L.R. Planning Commission in the Little Rock Board of Directors Chambers, second floor, City Hall, 500 West Markham Street, on December 15, 2016 at 4:00 P.M. This notice is provided in order to assure that neighborhood associations are aware of issues that may affect their neighborhood. Information requests should be directed to the Planning staff at 371-4790. Tony Bozynski Director of Planning and Development subd.doc 03/01/10 NOTICE OF PUBLIC HEARING BEFORE TEE LITTLE ROCK PLANNING COMMISSION ON AN APPLICATION TO SUBDIVIDE PROPERTY To ALL owners of land lying adjacent to (including across the street from) the boundary of the property located at: (GENEW LOCATION OF PROPERTY ON WHICH IS PROPOSED TO BE SUBDIVIDED) :'� / aLss ezo 021 (ADDRESS OF PROPERTY TO BE SUBDIVIDED, IF AVAILABLE) Owned by:. l r a C L a L (NAME OF OWNER) p {� (ADDRESS OF OWNER) Number of proposed lots: n ; Proposed use of property: NOTICE IS HEREBY GIVEN THAT an application for the subdivision of the property cited above has been filed with the Department of Planning and Development. A public hearing to review a prelimina plat for this property will be held by the Little Rock Planning Commission on — � C %r'j� iR 1 S` Z o1 to at : 06) P.M_ in the Board of Directors Chamber, second floor, Little Rock City Hall, , located at 500 W. Markham Street. Note: The platting into lots and streets may involve a request for variances or waivers from the standards set forth in the Subdivision Regulations of the City of Little Rock. ALL PARTIES IN INTEREST MAY APPEAR and be heard at the above cited time and place, or any party in interest may notify the Planning Commission of their views on this matter by letter_ AD persons interested in this request are invited to call or visit the Department of Planning and Development, located at 723 W. Markham St., phone, 371-4790, to review and discuss the application information with the Planning staff. Correspondence to the Planning Commission may be addressed to the Commission as a whole or to individual Commission members in care of the Little Rock Department of Planning and -Development, 723 W. Markham St., Little Rock, AR 72201. AFFIDAVIT I hereby certify that I have notified all the abutting property owners of record of the above property that subject property is being considered for subdivision and that a Public Hearing is to be held by die Little Rock Planning Commission at the time and place described above. Applicant (Owner or Authorized Agent) I �] z�r�l e c /v` � ( 7 fri�lL' (Name (Date) Gateway Ownership List 1. Gateway Creek, LLC c/o Colliers International P.O. Box 3546 Little Rock, AR 72203 2. NED Little Rock LLC c/o New England Development 75 Park Ave Boston, MA 02116 3. Chick-fil-A, Inc. 5200 Buffington Road Atlanta, GA 30349 4. Gateway Village 1 LLC - Town Center LLC P.O. Box 30730 Little Rock, AR 72223 5. Otter Creek Lodging, LLC c/o Animesh Patel 11701 Interstate 30 Little Rock, AR 72209 McGetrick & McGetrick, Inc. Civil Engineering November 8, 2016 Donna James, Subdivision Administrator City of Little Rock, Arkansas Planning and Development 723 West Markham Little Rock, AR 72201-1334 Re: Replat lot 4 Gateway Town Center Phase 4 Dear Ms. James: We are herewith submitting replat for the abovereferenced site. It consists of 7 lots varying in size from 2 to 14 acres. Al public streets have been installed and approved. The new lots will have access easements for lots that do not have frontage on a public street. We have shown locations of drives off of Bass Pro Parkway with a 250' spacing. The owner is Bass Pro Outdoor World LLC., 2500 East Kearney, Springfield, Mo. If you have any questions regarding the information provided, please feel free to contact me. Sincerely, McG & McGetrick, Inc. Patrick M. McGetrick, P.E. PM:cmc 11601 Bass Pro Parkway Little Rock, AR 72210 501455-8899 501-455-0525 mcgetrick2@sbcglobal.net ' Domestic Mail Onh ' For delivery inforrnati -• Il�l���rw�:�:r��s; Ln Ln Certified Mail Fes 13.3O ru s t f Extra Services & Fees (checkbc , &rid fea��o�oJ ❑ Return Receipt (hardtop» $ [IReturn Receipt (electronic) $ —- O ❑Certifled Mail Restricted Delivery $ _. gr� -00 � []Adult Signature Re quired $ t�-rfY0 ❑ Adult Signature Restricted Delivery $ p Postage #17.47 E3Total Postage and F 77 I.$ 07 Postmark Here 11/30/2016 r-q Gateway Creek LLC c/o Colliers International c3 P.O. Box 3546 Little Rock, AR 72203 R1-Z 24u 14r 1=Se1r1F_7.111 W'Ir.0.^H-�-Y2 VA_ � r9lrE�7'1a!b'fJ�Q-Z:i:•:SA'L:i6Y=17 hZ! r rhYl l r r BSI hL!•`>a ED Domestic Mail Only rU Er- For die-liv.ery information, visit our websit Ln Ln Certified Malt Fee $3.30 ru $ I fl Extra Services & Fees (shack llox, add tea dRGl7AriaNJ ❑ —0 Karam ligreipt (herdcopY) Q ❑ Return Receipt (electronic) $ C-3 ❑ Certified Mail Restricted Delivery $L■��) 0 ❑ Adult Signature Required $$0 Fffrlt []Adult Signature Restricted Delivery $ O Postage $0.47 = $ `3 Total postage and "a. 77 u7 dGateway Village 1/Town Center LLC o P.O. Box 30730 17- Little Rock, AR 72260 0033 07 Postmark Here 11/30/2016 I' i,'�.;'��C]s1h41i ,r!I -0 Domestic Mail Only E3 C3.16 Ir • BOST N? 11A 02116 LnCeriiflad Mali Fee $3 . 3O 0033 ru $ Sri. ri 07 ra Sere cm & Fees Oheck 4w, ilea aappprowr 'W ❑ Return Receipt (hardtop» $ ...� ❑Return Receipt (elecaonlc) $ tl Postmark 1-3 ❑ Cadillac! Mail Restricted Delivery $ $0 _ I]fl_ 1��L_ Here C ❑ Adult Signature Required $ �rvor C ❑ Adult Signature Restricted Delivery$ M Postage $0.47 = S 11 /37ri 2016 .11 Total Postage and F . C3 77 $ — Ln NED Little Rock, LLC c/o New Eng. Dev. E3 75 Park Avenue r1-- Boston, MA 02116 m Domestic Q' ul W Certified Mail Fee $3 , � 0033 ru $ 07 xlra ervlcas Be6(checkbWr,Bddfee�Y ❑ Return Receipt (hardcopy) $ ❑m Return Receipt (electronic) $ Postmark O I] ❑ Certified Mall Realrloted Do" $ _ Il 00 Here p ❑Adult Signature Required $ tf� ❑Aduh Sign alum Restricted Delivery $ O Postage #0.47 11/30/2016 E3 Total Postage and $ , , 77 $ Lr - Chick-fil-A Inc. 5200 Buffington Road Atlanta, GA 30349 m frr, Domestic Mail Only o, - For deliv6ry. information, visit our LITTLE ROCKY AR-72209 . Ln _ Ln Cert€fled Mali Fee $3.3i i 0033 ru $ �7 � Extra Ices & Fees phackbr -. add fav s app uatkteY gIt �l�� ❑ Return Receipt (hardcopY) $ • -� ❑ Return Receipt (electronic) Postmark 0 E3 ❑ Certified Mall Restricted Delivery $ $ 0 _ 00 Here O ❑Adult Signature Required $ f 0.99 ❑lgn Adult Restricted Delivery $ o Postage $0.47 11/30/2016 0 Total Postage andF�ey .77 � r Otter Creek Lodging ttC c/o Animesh Patel E3 11701 Interstate 30 r` Little Rock, AR 72209