HomeMy WebLinkAboutStaff Report for S-1979September 12, 2024
ITEM NO.: 6 FILE NO.: S-1979
NAME: Ali Addition – Preliminary Plat
LOCATION: 7520 N. Chicot Road
DEVELOPER:
Syed Ali
1809 Martha Drive
Little Rock, AR 72212
OWNER/AUTHORIZED AGENT:
Tim Daters (Agent)
White-Daters & Associates, Inc.
24 Rahling Circle
Little Rock, AR 72223
SURVEYOR/ENGINEER:
White-Daters & Associates, Inc.
24 Rahling Circle
Little Rock, AR 72223
AREA: .57 acres NUMBER OF LOTS: 5 FT. NEW STREET: 0 LF
WARD: 7 PLANNING DISTRICT: 15 CENSUS TRACT: 41.03
CURRENT ZONING: R-2
VARIANCE/WAIVERS:
1. Variance to allow reduced lot widths.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant proposes to subdivide .57 acres of property into 5 lots for single
family residential development.
B. EXISTING CONDITIONS:
The property is vacant except for a old house that will be demolished.
September 12, 2024
ITEM NO.: 6 (Cont.) FILE NO.: S-1979
2
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property abutting the site, and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
1. Any work involving one (1) or more acres of disturbed area requires a State of
Arkansas NPDES permit. Contact the Arkansas Department of Environmental
Quality, NPDES branch at 501-682-0744 for applications and information about
General Stormwater Discharge Construction Permit #ARR150000.
2. A grading permit may be required prior to initiation of work. Grading permits are
issued by the Planning and Development Dept. at 723 West Markham Street
after approval of sediment and erosion control plans, grading and drainage
plans, land survey, drainage study, and soil loss calculations per City’s
stormwater management and drainage manual. Contact Planning and
Development Dept., Engineering Division at 501-371-4817 or at 501-918-5348
or Permits@littlerock.gov to schedule an appointment for issuance or to answer
any questions. Permit cost is based on total project area at $100.00 for the less
than ½ acre, $200.00 for ½ to 1 acre, and $200.00 for the first acre and $100.00
for each additional acre for project greater than 1 acre.
3. Damage to public and private property due to hauling operations or operations
of construction related equipment from a construction site shall be repaired by
the responsible party prior to the issuance of a certificate of occupancy.
4. Per City Code 31-89 (5) for a preliminary plat, a storm drainage preliminary
analysis is required showing drainage data for all watercourses entering and
leaving the plat boundaries. The storm drainage analysis shall be prepared in
sufficient detail to illustrate the proposed system’s capability of accommodating
storm events as required by the stormwater management and drainage
manual. The preliminary plat shall also show drainage arrows indicating how
drainage arrives at the site and drainage arrows how it leaves the site post
development. Indicate where the storm sewer pipes, and curb inlets are located
within the development also. Additionally, provide profile and cross- sectional
views of the detention structure outlet/spillway and detention calculations for
the 25- and 100-year storm for the proposed detention pond/structure.
Delineation of the drainage areas pre and post construction with respective
discharges via rational method shall also be shown. The preliminary plat shall
also contain all information as outlined in City Code Sec. 31-89 and 31-90.
5. A Special Flood Hazard Development Permit is required to be obtained to prior
to beginning land alteration and/or construction within the 100-year regulatory
floodplain. The Special Flood Hazard Development Permit application can be
found at https://www.littlerock.gov/city-administration/city-departments/public-
works/. Special Flood Hazard Development Permits are issued by the Public
Works Department at 701 West Markham Street and no fee collected for
September 12, 2024
ITEM NO.: 6 (Cont.) FILE NO.: S-1979
3
issuance. Contact Vince Floriani in Public Works at 501-371-4823 or
VFloriani@littlerock.gov to schedule an appointment for issuance or to answer
any questions.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments received.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: No comments.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2021 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access Road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2021 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied, and the applicant
must submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2021
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads and
shall meet the requirements of Section D104.3.
September 12, 2024
ITEM NO.: 6 (Cont.) FILE NO.: S-1979
4
Exceptions:
1. Where there are more than 30 dwelling units on a single public
or private fire apparatus access road and al dwelling units are
equipped throughout with an approved automatic sprinkler
system in accordance with Section 903.3.1.1, 903.3.1.2 or
903.3.1.3 of the Arkansas Fire Code, access from two directions
shall not be required.
2. The number of dwelling units on a single fire apparatus access
road shall not be increased unless fire apparatus access roads
will connect with future development, as determined by the fire
code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2021 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Jason Lowder 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Codes: No comments received.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division:
The request is in the Geyer Springs West Planning District. The Land Use Plan
shows residential Medium Density (RM) for the requested area. The Future Land
Use Plan was amended from Residential Low Density to Residential Medium
Density by Ordinance No. 22,008 in 2021. The Residential Medium Density (RM)
category accommodates a broad range of housing types including single family
attached, single family detached, duplex, town homes, multi-family and patio or
garden homes. Any combination of these and possibly other housing types may
fall in this category provided that the density is between six (6) and twelve (12)
dwelling units per acre.
September 12, 2024
ITEM NO.: 6 (Cont.) FILE NO.: S-1979
5
Surrounding the application area on the south and to the east across N Chicot
Road are areas of Residential High Density (RH) with undeveloped timber, an
apartment complex and a single-family residence. On the west side of the subject
site is an undeveloped tract of Residential Low Density (RL) use. North of the site
is Public/Institutional (PI) use with a faith-based organization.
This site is not located in an Overlay District.
Master Street Plan:
N Chicot Road is a Collector on the Master Street Plan. Collectors are designed
to connect traffic from Local Streets to Arterials or to activity centers, with the
secondary function of providing access to adjoining property. The standard Right
of way is 60’. Sidewalks are required on one side of Collectors. This street may
require dedication of right-of-way and may require street improvements.
Bicycle Plan:
N Chicot Road is on the Master Bike Plan as a Proposed Class 3 Bike Route.
Class 3 Bike Routes require no additional right-of-way, but either a sign or
pavement marking to identify and direct the route.
Historic Preservation Plan:
This property is not located in a Historic District.
September 12, 2024
ITEM NO.: 6 (Cont.) FILE NO.: S-1979
6
H. ANALYSIS:
The applicant proposes to subdivide .57 acres of property into 5 lots for single
family residential development. The property is mostly undeveloped but contains
an old single-family structure which is in a state of disrepair.
The proposed five (5) lots will range in area from 6,332 square feet to 6,459 square
feet. Lots 1 through 4 will have a lot width of 48 feet, with lot 5 having a lot width
of 50.09 feet. The lot depths will range from 128 feet to 133 feet. A 25-foot front
building line is shown for all lots.
Section 36-342.2(d)(4) requires a minimum lot width of 50 feet. The applicant is
requesting a variance to allow 4 of the 5 lots to be 48 feet wide. Staff is in support
of the variance request.
To staff’s knowledge there are no outstanding issues associated with the proposed
preliminary plat. Staff is supportive of the proposed preliminary plat. The single-
family subdivision should have no adverse impact on the surrounding properties.
I. STAFF RECOMMENDATION:
Staff recommends approval of the requested preliminary plat, subject to
compliance with the comments and conditions outlined in paragraphs D and E,
and the staff analysis of the agenda staff report.