HomeMy WebLinkAboutS-1076-C ApplicationPublic Works Review Comments
Planning Commission Board of Adjustment
Agenda Date: 4-3-14
Z File Number S-1076-C
Moon Distribution Sub. Site plan review 2800 Vance
2
3.
4.
A grading permit in accordance with Section 29-186 (c) and) will be required prior to
any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction.
Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
Easements are required for all stormwater drainage areas.
A special Grading Permit for Flood Hazard Areas will be required per Section 8-283
prior to construction.
The new addition is located within the 100 year floodplain. The addition to the
structure is required to be constructed to a minimum finish floor elevation of 257.75
feet or higher is required and shown on grading plans.
Z File Number S-128-NNN
Stephen Stephens Replat Lot 1 13460 Pleasant Forest Dr.
1. Repair or replace any curb and gutter or sidewalk that is damaged in the public
right-of-way prior to occupancy.
Z File Number S-1723
Stewart Rd. Estates preliminary Plat
700 Stewart Rd.
1. Stewart Road is classified on the Master Street Plan as a minor arterial. A
dedication of right-of-way 45 feet from centerline will be required.
2. The Master Street Plan standard for rural residential streets provides a 68 foot right
of way width, 24 feet paved driving surface, 6 foot paved shoulders, and no curb and
gutter. The proposed plan varies from that standard and a variance from the
Master Street Plan must be requested.
3. With site development, provide the design of street conforming to the Master Street
Plan. Construct a left turn lane on Stewart Road to the proposed street intersection
per the AASHTO design standards. The street should taper out 100 feet on each
edge of pavement to take care of the lane shifts. 120 feet should be provided for
the left turn storage. Plans should be submitted at time of construction to adjust as
necessary for the necessary striping and tapers. Striping should be installed in
conformance with AASHTO design standards. Contact Bill Henry, Traffic
Engineering, at 379-1816 with questions or request for additional information.
4. Stormwater detention ordinance applies to this property. The volume provided must
comply with the City of Little Rock ordinances and stormwater drainage manual.
5. Stormwater drainage calculations are not being approved by reviewed for approval
of the plat.
6. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
7. Provide a letter prepared by a registered engineer certifying the sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
8. The widths of the drainage easement should be increased to 15 feet wide.
9. Traffic calming devices are required for long straight streets to discourage speeding.
A 20 foot wide landscape island maintained by the Property Owners Association is
suggested. Contact Bill Henry, Traffic Engineering at 379-1816 for additional
information.
Z File Number Z-2502-B
New Africa long -form PCD 7700 W. 40th.
1. Due to the proposed use of the property, the Master Street Plan specifies that West
40th Street for the frontage of this property must meet commercial street standards
across the parking lot and school frontage. Dedicate right-of-way to 30 feet from
centerline.
2. Due to the proposed use of the property, the Master Street Plan specifies that
Whitfield Street for the frontage of this property must meet commercial street
standards. Dedicate right-of-way to 30 feet from centerline.
3. A 20 foot radial dedication of right-of-way is required at the intersection of West 40cn
Street and Whitfield Street.
4. Potter Street is classified on the Master Street Plan as a residential street. A
dedication of right-of-way 25 feet from centerline will be required.
5. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Potter Street including 5-foot
sidewalks with the planned development. The new back of curb should be located
13 feet from centerline. Potter Street is scheduled to be improved by the City of
Little Rock. Per City code, at the time of development, the adjacent property is
required to make street improvements or provide a payment in -lieu of construction
until the time the construction bids are open for the City of Little Rock project.
6. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Whitfield Street including 5-foot
sidewalks with the planned development. The new back of curb should be located
15.5 feet from centerline. At box culvert under Colonel Glenn Road was placed in
the Whitfield Street right of way. The street is shown to jog to the east and intersect
Colonel Glenn Road on property owned by AHTD. Permission must be obtained
from AHTD for Whitfield Street to be constructed on AHTD property.
7. Obtain permits for improvements within State Highway right-of-way from AHTD,
District VI. AHTD has been contacted about constructing Whitfield Street on AHTD
right of way.
8. The proposed east -west streets should be constructed to City of Little Rock
standards. Are the streets proposed to be public or private? Turnarounds are
required to be installed at the eastern ends or the eastern north -south driveway
placed within a public access easement. Access easements must be designed with
concrete aprons. Curb radius within the access easement must be designed for an
SU-30 vehicle with a 60 foot turning radius.
9. No residential waste collection service will be provided on private streets unless the
property owners association provides a waiver of damage claims for operations on
private property. In addition, the following comments must be agreed to for collection
and recycling service: 1.) service will be provided to one side of the through
easements/alleys which will require everyone to place their carts on the side of the
easement/alley as selected by the City of Little Rock; 2.) service will not be provided
to a dead-end alley. The easement/alley must have a separate entrance and exit;
3.) the City of Little Rock is not liable for damage to the easement/alley; 4.) if
easement/alley is obstructed on service day the City of Little Rock will not return until
the following week for pick up; 5.) yard waste will not be picked up in the rear
easement/alley. Yard waste is to be placed at the curb on the street in front of
house; 6.) a letter from the property owners association must be provided stating all
residents unanimously agree to all of the above conditions.
10. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The width of a driveway must not
exceed 36 feet.
11. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. The driveway spacing on West 40th
Street and Whitfield Street is 250 feet from other non-residential driveways and
streets and 125 feet from the property line. The driveway spacing on Colonel Glenn
Road is 300 feet from other non-residential driveways and streets and 150 feet from
the property line.
12. Prepare a traffic study for the school for student pickup and drop off. Vehicles are
not permitted to stack on City streets. The study should include vehicle stack
locations, vehicle stack distances, times of stack, number of students, existing and
proposed traffic flows and volumes.
13.In accordance with Section 32-8, no obstruction to visibility shall be located within a
triangular area 50 feet back from the intersecting right-of-way line (or intersecting
tangent lines for radial dedications). Show proposed gates and fencing.
14. Repair or replace any curb and gutter or sidewalk that is damaged in the public
right-of-way prior to occupancy.
15.A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction. Are areas proposed to be advanced graded with
construction on another phase?
16. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
17.If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
18. Street Improvement plans shall include signage and striping. Public Works must
approve completed plans prior to construction.
19. Per the Master Street Plan, parking is restricted to one side of the street on a 24 feet
wide street. Show on the plan now and on the final plat and bill of assurance, the
area along the street where parking is allowed.
20. Street names and street naming conventions must be approved by Public Works.
Contact Glenn Haley at (501) 371-4537.
21.In accordance with Section 31-210 (h)(12), access driveways running parallel to the
street shall not create a four-way intersection within 75 feet of the future curb line of
the street.
22. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by
the responsible party prior to issuance of a certificate of occupancy.
Z File Number Z-6998-A
Confetti's Party Rental Revised PC-D 6000 S. Shackleford Rd.
1. Shackleford Road is classified on the Master Street Plan as a minor arterial. A
dedication of right-of-way 45 feet from centerline will be required.
2. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Shackleford Road including 5-foot
sidewalks with the planned development. The new back of curb should be located
29.5 feet from centerline.
3. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction.
4. Stormwater detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan.
5. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
6. Street Improvement plans shall include signage and striping. Public Works must
approve completed plans prior to construction.
7. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Street lights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering 379-1813 (Greg
Simmons) for more information.
8. All driveways shall be concrete aprons per City Ordinance.
9. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by
the responsible party prior to issuance of a certificate of occupancy.
Z File Number Z-7812-A
Pintura Estates Short -form PD-R Single family 14800 Kanis Rd.
1. Kanis Road is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45 feet from centerline will be required.
2. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Kanis Road including 5-foot
sidewalk with the planned development. The new back of curb should be located
29.5 feet from centerline. The full half street improvements should extend to the
projection of the property to the right of way centerline and the taper created by
striping. The center median on Kanis Road should not be constructed with this
phase of construction of Kanis Road.
3. With site development, provide the design of street conforming to the Master Street
Plan. Construct street improvement to these streets with planned development.
The subdivision should be designed for turn movements by an SU-30 vehicle. The
entrance round -a -bout and island south of the entrance will not pass an SU-30
vehicle. Check geometry on all other turning movements.
4. The emergency access should be at least 20 feet wide and constructed to provide all
weather access.
5. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved prior
to the start of construction. Is a variance requested to advance grade the lots or
future phases with construction of the streets in the first phase?
6. Stormwater detention ordinance applies to this property. The detention pond
should be located where a sufficient amount of stormwater flow can be collected to
provide detention for this subdivision.
7. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Herbner).
8. If disturbed area is one (1) or more acres, obtain a NPDES stormwater permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
9. Street Improvement plans shall include signage and striping. Public Works must
approve completed plans prior to construction.
10. Streetlights are required by Section 31-403 of the Little Rock code. Provide plans
for approval to Traffic Engineering. Streetlights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineering 379-1813 (Greg
Simmons) for more information.
11. Hauling of fill material on or off site over municipal streets and roads requires
approval prior to a grading permit being issued. Contact Public Works Traffic
Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more
information.
12.The call box should be located for the gate to provide stack space for three (3)
vehicles between the call box and Kanis Road curb line. A turn around area for an
SU-30 vehicle should be provided between the call box and the gate.
13. Street names and street naming conventions must be approved by Public Works.
Contact Glenn Haley at (501) 371-4537.
14. Provide a letter prepared by a registered engineer certifying the sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
15. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by
the responsible party prior to issuance of a certificate of occupancy.
16. Baker Elementary School currently has a 5-year deferral for boundary street
improvements to Kanis Road and Baker Lane. Baker Lane will be relocated further
to the north to create a 90 degree intersection with Kanis Road. The current
driveway location will create left turn conflicts with school traffic.
17. No residential waste collection service will be provided on private streets unless the
property owners association provides a waiver of damage claims for operations on
private property.
18. For private streets, an entrance apron should be constructed of concrete from the
back of curb of the public street to the property line.
Z File Number Z-8924
Brasher Short -form PD-R 522 Rice
1. West 6th Street is classified on the Master Street Plan as a residential street. A
dedication of right-of-way 25 feet from centerline will be required.
2. The southeast corner of the lot must follow the curvature of the existing edge or
pavement of Rice Street and West 6th Street. A dedication of right-of-way to 10 feet
from the edge of pavement will be required.
3. The paved alley does not show on Pulaski County Parcel data. If the alley is
platted, it must be paved to at least 18 feet wide to the north property line.
4. Garbage collection will occur on West 6'h Street and Rice Street.
Z File Number Z-8925
Gillham Short -form PCD 5016 Asher Ave.
1. Asher Avenue is classified on the Master Street Plan as a principal arterial with
special design standards. Dedication of right-of-way to 45 feet from centerline will
be required.
2. A 20 foot radial dedication of right-of-way is required at the intersection of Asher
Avenue and Monroe Street.
3. Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the
private improvements located in the right-of-way including signage, parking and
gates.
4. Easements are required to be platted within the abandoned alley for stormwater
drainage.
Z File Number Z-8926
Ibsen Short -form PD-R 905 N. Spruce
No comments
Z File Number Z-962-A
Slim Chicken Short -form PCD 7524 Cantrell Rd.
1. Show the proposed street improvements on Keightley Drive and Cantrell Road to be
constructed by AHTD.
2. Show the right-of-way centerline, existing striping, existing edge of pavement or
back of curb, and driveways across the street on Keightley Drive. Pulaski County
parcel data shows the Keightley Drive right of way is a total of 40 feet wide.
3. The radius of driveways cannot extend beyond the projection of the property line to
the street. Driveway radiuses should not exceed 10 feet.
4. Were any access deed restrictions placed on the property by AHTD with the
purchase of right of way?
5. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. Per the Master Street Plan, Cantrell
Road is principal arterial street. The driveway spacing is 300 feet from intersections
and other driveways and 150 fee from side property lines. Per the Master Street
Plan, Keightley Drive is a commercial street. The driveway spacing is 250 feet from
intersections and other driveways and 125 feet from side property lines. The
proposed driveway locations do not comply with the spacing requirements.
Driveway spacing variances must be requested.
6. Repair or replace any curb and gutter or sidewalk that is damaged in the public
right-of-way prior to occupancy.
7. Obtain permits for improvements within State Highway right-of-way from AHTD,
District VI.
8. Submit traffic impact analysis including stacking analysis utilizing approved modeling
techniques to insure stacking does not occur on the adjacent street systems.
9. With site development, provide the design of street conforming to the Master Street
Plan. Construct one-half street improvement to Cantrell Road and Keightley Drive
including 5-foot sidewalks with the planned development. Some improvements are
being constructed on Cantrell Road and Keightley Drive by AHTD. If all boundary
street improvements as found in the Master Street Plan are not constructed by
AHTD, those remaining improvements are the responsibility of this property owner to
construct. Show the proposed improvements to Keightley Drive.
10.2012 Metro Plan Traffic counts show approximately 34,000 vehicles on Cantrell
Road per day. Left turns into the site from Cantrell Road will likely stop in the east
bound through lane due to vehicle stacking for west bound left turns to Mississippi
Avenue. This will cause vehicles to stack into the intersection.
MEMORANDUM
TO: DONNA JAMES, SUBDIVISION ADMINISTRATOR
FROM: TRACY SPILLMAN, PLANS DEVELOPMENT ADMINISTRATOR
SUBJECT: REVIEW OF THE BUFFER AND LANDSCAPE REQUIREMENTS OF
THE MARCH 12, 2014, SUBDIVISION COMMITTEE MEETING
CC: DANA CARNEY, ZONING & SUBDIVISION MANAGER
DATE: MARCH 07, 2014
NEW BUSINESS:
1. New Africa Mixed Use Development Long -form PCD [Z-2502-B
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
Street buffers .will be required at six (6) percent of the average depth of the lot. The minimum
dimension shall be one-half (%Z) the full width requirement but in no case less than nine (9) feet.
Interior landscape areas shall compromise 8% of any vehicular use area containing twelve (12)
or more spaces.
Landscape areas shall be provided between the vehicular use area used for public parking and
the general vicinity of the building, excluding truck loading or service areas not open to public
parking. These areas shall be equal to an equivalent planter strip three (3) feet wide along the
vehicular use area.
An automatic irrigation system to water landscaped areas will be required.
Prior to the issuance of a building permit, it will be necessary to provide an approved landscape
plan stamped with the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving
trees of six (6) inch caliper or larger.
Slim Chickens Short -form PCD Z-962-A
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
A land use buffer will be required when an adjacent property has a dissimilar use of a more
restrictive nature. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required upon the
property line side of the buffer. A minimum of seventy (70) percent of the land use buffer shall
be undisturbed. Easements cannot count toward fulfilling this requirement. The plantings,
existing and purposed, shall be provided within the landscape ordinance of the city, section 15-
81.
The property adjacent to the north property line, and the north portion of the property adjacent
to the west property line are zoned R-5. Therefore, a minimum eleven and a half (11.5) foot
wide buffer (6% of the average lot width) is required along the north property line. An eleven
(11) foot buffer (6% of the average lot depth) is required on the north portion of the west
property line.
Street buffers will be required at six (6) percent of the average depth of the lot. The minimum
dimension shall be one-half (%) the full width requirement but in no case less than nine (9) feet.
A minimum eleven and a half (11.5) foot wide buffer (6% of the average lot width) is required
along Cantrell Road.
Interior landscape areas shall compromise 8% of any vehicular use area containing twelve (12)
or more spaces.
A landscape irrigation system shall be required for developments of one (1) acre or larger. If an
automatic landscape irrigation system is not provided for developments of less than one (1) acre
a water source shall be located within seventy-five (75) feet of the plants to be irrigated.
Dumpsters shall be screened from abutting properties and streets. The screen shall exceed the
height of the dumpster or trash containment areas by at least two (2) feet not to exceed eight
(8) feet total height.
Menu board speakers for drive -through windows shall be designed to provide for a solid wall at
least six (6) feet in height and twenty (20) feet in length along the opposite lane line. This wall
shall be constructed of masonry or wood with a textured finish to diminish sound deflection.
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving
trees of six (6) inch caliper or larger.
Moon Distribution Subdivision Site Plan Review 5-1076-C
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
Interior landscape areas shall comprise a minimum of eight (8) percent of any vehicular use area
containing twelve (12) or more parking spaces.
An automatic irrigation system to water landscaped areas will be required.
Prior to the issuance of a building permit, it will be necessary to provide an approved landscape
plan stamped with the seal of a registered landscape architect.
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving
trees of six (6) inch caliper or larger.
4. Confetti's Party Rental devised PD-C (Z-6998-A
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
A land use buffer will be required when an adjacent property has a dissimilar use of a more
restrictive nature. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required upon the
property line side of the buffer. A minimum of seventy (70) percent of the land use buffer shall
be undisturbed. Easements cannot count toward fulfilling this requirement. The plantings,
existing and purposed, shall be provided within the landscape ordinance of the city, section 15-
81.
The property adjacent to the north property line, west property line, and a portion of the south
property line is zoned R-2. Therefore, a minimum twenty-eight and a half (28.5) foot wide buffer
(6% of the average lot width) is required along the west property line. A seventeen and a half
(17.5) foot buffer (6% of the average lot depth) is required on the north and south property line.
Street buffers will be required at six (6) percent of the average depth of the lot. The minimum
dimension shall be one-half (%z) the full width requirement but in no case less than nine (9) feet.
The average lot depth is approximately three hundred and fifty-eight (358) feet. A twenty-eight
and a half (28.5) foot street buffer will be required.
Landscape areas shall be provided between the vehicular use area used for public parking and
the general vicinity of the building, excluding truck loading or service areas not open to public
parking. These areas shall be equal to an equivalent planter strip three (3) feet wide along the
vehicular use area.
An irrigation system shall be required for developments of one (1) acre or larger.
Curb and gutter or other approved border is required to protect landscape areas from vehicular
traffic.
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving
trees of six (6) inch caliper or larger.
Gillham Short -form PCD Z-8925
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
If building rehabilitation exceeds fifty percent (50%) of the replacement cost then the
landscaping and buffer must also come into compliancy accordingly.
All vehicular use areas which were in existence prior to the effective date of the Landscape
Ordinance may continue as non -conforming until such time a building permit is issued to
rehabilitate a structure on the property exceeding (50) percent of current replacement cost of
the structure. At such time (50) percent of the existing vehicular use area shall be brought into
compliance and shall continue to full compliance on a graduated scale based on the percentage
of rehabilitation cost.
A land use buffer will be required when an adjacent property has a dissimilar use of a more
restrictive nature. As a component of all land use buffer requirements, opaque screening,
whether a fence or other device, a minimum of six (6) feet in height shall be required upon the
property line side of the buffer. A minimum of seventy (70) percent of the land use buffer shall
be undisturbed. Easements cannot count toward fulfilling this requirement. The plantings,
existing and purposed, shall be provided within the landscape ordinance of the city, section
15-81.
The property adjacent to the north and east property lines is zoned C4. The minimum buffer
shall be (6% of the average lot width) with minimum dimension of nine (9) feet in all instances.
A nine (9) foot buffer is required along north and east property lines.
Street buffers will be required at six (6) percent of the average depth of the lot. The minimum
dimension shall be one-half (%2) the full width requirement but in no case less than nine (9) feet.
A nine (9) foot buffer is required along Asher Avenue.
The property is located in the City's designated mature area a 25% reduction of the buffer
requirements is acceptable.
Interior landscape areas shall compromise 8% of any vehicular use area containing twelve (12)
or more spaces.
If an automatic landscape irrigation system is not provided for developments of less than one (1)
acre a water source shall be located within seventy-five (75) feet of the plants to be irrigated.
Curb and gutter or other approved border is required to protect landscape areas from vehicular
traffic.
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving
trees of six (6) inch caliper or larger.
Little Rock Wastewater Comments
Project Number S-1076-C
Project Name Project Type
Moon Distribution Site Plan Review
Project Number S-128-NN
Project Name
Project Type
Lot 1 Stephen Stephens
Replat - Lot Combination
Addition
Project Number S-1723
Project Name
Project Type
Stewart Road Estates
Subdivision Single Family
Project Number Z-2502-B
Project Name
Project Type
New Africa Mixed Use
Planned Commercial Development
Project Number Z-6998-A
Project Name
Project Type
Confetti's Party Rental
Planned Commercial Development
Project Number Z-7812-A
Project Name
Project Type
Pintura Estates
Planned Residential Development
Project Number Z-8924
Project Name
Project Type
Brasher
Planned Residential Development
Project Number
Z-8925
Project Name
Project Type
Gillham
Planned Commercial Development
Project Number
Z-8926
Project Name
Project Type
Comment Made
Sewer main relocation required prior to construction of
proposed warehouse.
Comment Made
Sewer available to this project.
Comment Made
Outside Service Boundary, no comment.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project.
Comment Made
Sewer main extension required with easements if sewer
service is required for this project.
Comment Made
Sewer available to this project.
Comment Made
Sewer available to this project.
Comment Made
Thursday, February 27, 2014 Page 1 of 2
. Ibsen
Project Number Z-962-A
Project Name
Slim Chickens
Planned Residential Development
Project Type
Planned Commercial Development
Sewer available to this project.
Comment Made
Sewer available to this project.
Thursday, February 27, 2014 Page 2 of 2
PLANNING COMMISSION REVIEW
CENTRAL ARKANSAS WATER
12 March 2014
NAME
IBSEN PDR; 905 N. SPRUCE ST
TYPE ISSUE COMMENTS
PDR Z-8926 NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
PA
NAME
TYPEISSUE
NEW AFRICA MIXED USE DEV / PCD Z-2502-B
PCD, POTTER & 40TH ST
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
`a
NAME TYPE ISSUE COMMENTS
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned line Agreement is
required.
A Capital Investment Charge based on the
size of connection(s) will apply to this project
in addition to normal charges for all
connection off Potter St. This fee will apply
to all connections including metered
connections off the private fire system.
Existing waterline easement recorded as
Inst. No. 86-66357 should be reflected on
the plat. It appears that this will affect the
buildable area on lots 1, 11 and 23.
3
NAME TYPE ISSUE COMMENTS
3. SLIM CHICKENS PCD; 7524 PCD Z-962-A All Central Arkansas Water requirements in
CANTRELL RD effect at the time of request for water service
must be met.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
required.
4.
NAME
MOON DISTRIBUTION SITE
PLAN; 2800 VANCE ST.
TYPEISSUE
SITE PLAN S-1076-C
COMMENTS
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
5
NAME TYPE ISSUE COMMENTS
required.
NAME TYPE ISSUE COMMENTS
CONFETTI'S PARTY RENTAL, PD-C Z-6998-A All Central Arkansas Water requirements in
PDC 6000 S. SHACKLEFORD RD effect at the time of request for water service
must be met.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
NAME TYPE ISSUE COMMENTS
required.
BRASHER PDR, 522 RICE ST PDR Z8924 NO OBJECTIONS. All Central Arkansas
Water requirements in effect at the time of
request for water service must be met.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
0
NAME
7. STEWART RD ESTATES PRELIM
PLAT, STEWART & LONGWOOD
TYPE ISSUE COMMENTS
PREPLAT S-1723 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
ADDITIONALLY THIS AREA IS WITHIN
WATER IMPROVEMENT DISTRCIT 349
AND PROPERTIES WILL HAVE A SPECIAL
IMPROVEMENT TAX FOR THE DISTRICT
ON THEIR PROPERTY TAXES.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
P]
NAME TYPE ISSUE
COMMENTS
8. LOT 1 STEPHEN STEPHENS REPLAT S-128-NNN
NO OBJECTIONS. All Central Arkansas
ADDTN; REPLAT LOT 152 &
Water requirements in effect at the time of
TRACT A LONGLEA VI I ADDTN &
request for water service must be met.
LOTS 3,4,5 WOODLAND FARM
ESTATES; 13460 PLEASANT
If there are facilities that need to be adjusted
FOREST DR
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges.
Contact Central Arkansas Water regarding
the size and location of the water meter.
10
0
NAME
GILLHAM PDC; 5016 ASHER AVE
TYPE ISSUE COMMENTS
PDC Z-8925 All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
Contact Central Arkansas Water if additional
fire protection or metered water service is
required.
Contact Central Arkansas Water regarding
the size and location of the water meter.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Due to the nature of this facility, installation
of an approved reduced pressure zone
backflow preventer assembly (RPZ) is
required on the domestic water service. This
assembly must be installed prior to the first
point of use. Central Arkansas Water (CAW)
requires that upon installation of the RPZA,
successful tests of the assembly must be
completed by a Certified Assembly Tester
licensed by the State of Arkansas and
approved by CAW. The test results must be
sent to CAW's Cross Connection Section
within ten days of installation and annually
thereafter. Contact the Cross Connection
Section at 377-1226 if you would like to
discuss backflow prevention requirements
for this project.
The facilities on -site will be private. When
meters are planned off private lines, private
facilities shall be installed to Central
Arkansas Water's material and construction
specifications and installation will be
inspected by an engineer, licensed to
practice in the State of Arkansas. Execution
of Customer Owned Line Agreement is
11
10
NAME TYPE ISSUE COMMENTS
required.
PINTURA SUBD, PDR / 14800 PD-R Z-7812-A A Capital Investment Charge based on the
BILK OF KANIS size of connection(s) will apply to this project
in addition to normal charges for all main
extensions and connections off Kanis Rd.
All Central Arkansas Water requirements in
effect at the time of request for water service
must be met.
A water main extension will be needed to
provide water service to this property.
This development will have minor impact on
the existing water distribution system.
Proposed water facilities will be sized to
provide adequate pressure and fire
protection.
The Little Rock Fire Department needs to
evaluate this site to determine whether
additional public and/or private fire hydrant(s)
will be required. If additional fire hydrant(s)
are required, they will be installed at the
Developer's expense.
Please submit plans for water facilities
and/or fire protection system to Central
Arkansas Water for review. Plan revisions
may be required after additional review.
Contact Central Arkansas Water regarding
procedures for installation of water facilities
and/or fire service. Approval of plans by the
Arkansas Department of Health Engineering
Division and Little Rock Fire Department is
required.
A Capital Investment Charge based on the
size of meter connection(s) will apply to this
project in addition to normal charges. This
fee will apply to all connections including
metered connections off the private fire
system.
If there are facilities that need to be adjusted
and/or relocated, contact Central Arkansas
Water. That work would be done at the
expense of the developer.
12
I
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
2014035664 Received: 6/20/2014 1:51:43 PM
Recorded: 06/20/2014 01:59:52 PM Filed &
Recorded in Official Records of Larry Crane,
PULASKI COUNTY CIRCUIT/COUNTY CLERK
ORDINANCE NO. 20,891 Fees $15.00
AN ORDINANCE TO AMEND CHAPTER 13 OF THE CODE OF
ORDINANCES OF THE CITY OF LITTLE ROCK, ARKANSAS; TO
PROVIDE FOR A VARIANCE FROM THE CONSTRUCTION
STANDARDS OF STRUCTURES WITHIN THE 100-YEAR
FLOODPLAIN FOR THE MOON DISTRIBUTION WAREHOUSE
FACILITY LOCATED AT 2800 VANCE STREET, SOUTHEAST OF THE
CORNER OF INTERSTATE 30 AND ROOSEVELT ROAD; AND FOR
OTHER PURPOSES.
NOW, THEREFORE, BE IT ORDAINED BY THE BOARD OF DIRECTORS OF THE CITY
OF LITTLE ROCK, ARKANSAS:
Section 1. That Chapter 13 of the Code of Ordinances be amended to provide for a variance from
the construction standards for structures within the 100-year floodplain for the Moon Distribution
warehouse facility located at 2800 Vance Street southeast of the corner of Interstate 30 and Roosevelt
Road.
Subsection a. Chapter 13, Section 59(2) requires the top of the finished floor of non-
residential structures be elevated to one (l)-foot or more above the base flood elevation
of Fourche Creek, 256.75 feet mean sea level (MSL). The top of the finished floor of the
warehouse addition is proposed to be constructed less than one (1)-foot above the base
flood elevation of Fourche Creek or to an elevation of 257.10 feet MSL.
Section 2. This ordinance shall take effect thirty (30) days from and after its passage.
PASSED: June 17, 2014 7
y, City Clerk
AS TO LEGAL FORM:
Thomas M. Carpent ,City orney
//
APPROVE
iviarK �toaoia, mayor
A�4`tt �DtiWl'S, A `�
y
Area Coning
Location: 2800 Vance Street
Ward: 1
PD:
CT: `.
TRS: T1 N R12W14
N
A
0 235470 940 Feet
�s�r sa sr�teer -�
E7113T4G WAREHOUSE
FFE • 257 10
All
1
yy
I p r .intL yN•y
T�
--
_ i1
• '7d
A• ..yam. ew, 1 . .. .
- f
.j
I�
I
•
� I
CF
ti �
f
r �
e • ✓w r w +
�II .l!..� '!LAC' rr •Y. /' I,�FI
2800 VANCE STREET SITE PLAN REVIEWIN
tJ
���� ra . • u� P o N �3 � .. 1 to wEC CH; �
91
o rd W
'MaDj ceeN� .OP 13
z�p�7 v� o rzv N n E►21ST+ST _¢ j
21 v W Cp p
E=22ND-5T- m=aop CFq
Ifma7 _ n
PA Wi23Rp STf °6( 4, 8
E 23RCtrsT �Jd,
!i ra a k' eD OUcU
m p 4 B E=WAT
24TH S'C
6 W,RO - SEVEU Rp C7� 7
�� o
' E: RaOSEVEUTIRa_
p ® �S ;� - E 2BTFi ST D� o � I o 'w'26TH-SI r,r� ,� o " ���� 1 °7 71 E 20 ils. E•2 T' HPS r
a S c�l�• a CIE-2` RKST E; E26TH-5T �
d 27TH'$T G IWR °
W 27TH sr E 27, 1 Sr � o �I �. �j o ] �"
I o 11
v _ �' le : "C. ��0 E�28TH,ST m p It1 —
1�287H 57 ; €3 ea�7� G7=E 28THST am aV=r-
_ 4 $ o f [�Z - 9 Qom- ^-�w tQ
ap g 3�f& (� pp�.Wa� x¢4 1
c. 't LU
w 29THr ~ � r �� 6 Op -
1- E•29TH-S7 r� �v ❑ Cl 4 i
g n¢T j
WW
fl jam.
.�3; 757$T ocM� ° ® C4
1 THIS
°
W� SITE
a- u
R3
o � a
9 R2
C
P � �-3aanQ sfl
Area Zoning
9
Case: S-1076-C N
Location: 2800 Vance Street
Ward: 1
PD: 7 0 235470 940 Feet
CT. 5
TRS: T1 N R12W14
S-1076-C io 2800 VANCE STREET 40 SITE PLAN REVIEW
Et
City of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
April 4, 2014
Thomas Engineering
3810 Lookout Road
North Little Rock, AR 72116
Planning
Zoning and
Subdivision
Re: Moon Distribution Subdivision Site Plan Review (S-1076-C), located
at 2800 Vance Street
Dear Sirs:
This is to advise you that in connection with your request concerning the above
referenced file number the following action was taken by the Planning
Commission at its meeting on April 3, 2014:
X Approved with conditions.
Recommended approval with conditions.
Recommended approval as submitted.
Denied your request as submitted.
Deferred to the
Other:
Meeting.
If you have any questions please do not hesitate to contact me at 371-6821.
Respectfully,
Donna James, AICP
Subdivision Administrator
ta
City of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
DATE: February 24, 2014
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
Planning
Zoning and
Subdivision
NAME: Moon Distribution Subdivision Site Plan Review
TYPE OF ISSUE: Site Plan Review
FILE NUMBER: S-1076-C
LOCATION: 2800 Vance Street
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On April 3, 2014 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on March 7, 2014.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on March 12, 2014.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Sincerely,
4
Donna mes, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY March 10, 2014.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
By:
Enclosure
ta
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6663
DATE: February 24, 2014
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
NAME: Moon Distribution Subdivision Site Plan Review
TYPE OF ISSUE: Site Plan Review
FILE NUMBER: S-1076-C
LOCATION: 2800 Vance Street
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On April 3 2014 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on March 7, 2014.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on March 12, 2014.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Sincerely,
Dnna mes, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY March 10, 2014.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments: � Se ed ty #b 6bawll 7 ' C ( H'Sf�f l�t�Sf
LIM
Et
City of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6663
DATE: February 24, 2014
Planning
Zoning and
Subdivision
NAME: Moon Distribution Subdivision Site Plan Review
Entergy (2) TYPE OF ISSUE_ Site Plan Review
Center Point - ARKLA FILE NUMBER:
S-1076-C
AT & T (2)
Central Arkansas Water LOCATION: 2800 Vance Street
Little Rock Wastewater
Pulaski County Planning
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development — Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On April 3, 2014 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on March 7, 2014.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on March 12, 2014.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Sincerely,
i
Donna mes, AICP
Subdivision Administrator
(Please resp below and return this letter with your comments for our records.)
Approved as Submitted. I PLEASE RETURN COMMENTS BY March 10, 2014.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of IO feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments: — _
i 4 r--
�
By:
Enclosure
IR
City of Little Rock
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
DATE: February 24, 2014
Entergy (2)
Center Point - ARKLA
AT & T (2)
Central Arkansas Water
Little Rock Wastewater
Pulaski County Planning
Planning
Zoning and
Subdivision
NAME: Moon Distribution Subdivision Site Plan Review
TYPE OF ISSUE: Site Plan Review
FILE NUMBER: S-1076-C
LOCATION: 2800 Vance Street
Little Rock Fire Department
Public Works: Engineering, Traffic (2)
Parks and Recreation Department
Planning and Development - Site Plan Review
Planning and Development Graphics
CATA
TO WHO IT MAY CONCERN:
On April 3, 2014 the Little Rock Planning Commission will consider the above referenced issue.
NOTE: The Interdepartmental Meeting at which this issue will be discussed will be held on March 7, 2014.
NOTE: The Subdivision Committee Meeting at which this issue will be discussed will be held on March 12, 2014.
A copy of the plan for the referenced issue is enclosed for your consideration, and your comments and/or
recommendations will be appreciated.
Sincerely,
Donna mes, AICP
Subdivision Administrator
(Please respond below and return this letter with your comments for our records.)
Approved as Submitted.
PLEASE RETURN COMMENTS BY March 10, 2014.
Easement (s) required (See attached plat or description.)
*To all utilities: If an easement is requested which is in excess of 10 feet in width, provide justification for the
easement or the request will not be included in the Planning Commission agenda.
Comments:
krcrr 141�'XAP_ -7b 3C � ;,fY 1 Z7,—RGY FA}c t L-yrit3 rN cot ff-14cT w l7yi -
�5 P�G7: 1i� i'�w 8JcI--7�Z 0-u�-7 CDN� AcT �cy c�zL iN AZJ���3 IF
By: -uMe- tt A 5---90cc L'F69i!P�- 15-
Enclosure
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
tittle Rock, Arkansas 72201-1334
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863 Subdivision
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
DATE: February 26, 2014
TO: _ _ City Director Erma Hendrix
ADDRESS: 921 West Roosevelt Road
Little Rock AR 72206
REQUEST: Moon Distribution Subdivision Site Plan Review (S-1076-C), a request to
for a site plan review to allow an expansion of an existing warehouse by adding 118,00_0
square feet along the south side of the existing warehouse building and to allow the
construction of a new parking area within the same general area.
GENERAL LOCATION OR ADDRESS
2800 Vance Street
OWNED BY/APPLICANT: Moon Distribution, Owner — Thomas Engineering Company,
Agent (501-753-4463)
NOTICE IS HEREBY GIVEN THAT an application for a Subdivision Site Plan Review of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on April 3, 2014
at 4:00 P.M. This notice is provided in order to assure that neighborhood associations
are aware of issues that may affect their neighborhood. Information requests should be
directed to the Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
City of Little Rock
Department of Planning and Development Planning
723 West Markham Street Zoning and
Little Rock, Arkansas 72201-1334 Subdivision
Phone: (501) 371-4790 Fax: (501) 399-3435 or 371-6863
NOTICE OF PUBLIC HEARING BEFORE THE LITTLE ROCK PLANNING
COMMISSION ON A REQUEST FOR A USE CHANGE OR DEVELOPMENT OF
LAND
DATE: February 26, 2014
TO: Community Outreach N.A
ATTENTION: Margie Jones
ADDRESS: 2614 South Commerce
Little Rock. AR 72206
REQUEST: Moon Distribution Subdivision Site Plan Review (S-1076-C),_a request to
for a site plan review to allow an expansion of an existing warehouse by adding 118,000
s uare fleet aloe the south side of the existing warehouse building and to allow the
construction of a new parking area within the same general area.
GENERAL LOCATION OR ADDRESS: 2800 Vance Street
OWNED BY/APPLICANT: Moon Distribution, Owner -- Thomas Engineering Company,
Agent (501-753-4463)
NOTICE IS HEREBY GIVEN THAT an application for a Subdivision Site Plan Review of
the above property has been filed with the Department of Planning and Development. A
public hearing will be held by the L.R. Planning Commission in the Little Rock Board of
Directors Chambers, second floor, City Hall, 500 West Markham Street, on April 3, 2014
at 4:00 P.M. This notice is provided in order to assure that neighborhood associations
are aware of issues that may affect their neighborhood. Information requests should be
directed to the Planning staff at 371-4790.
Tony Bozynski
Director of Planning and Development
NOTICE OF PUBLIC HEARING BEFORE
THE LITTLE ROCK PLANNING COMMISSION
ON AN APPLICATION FOR SITE PLAN REVIEW
To ALL owners of land lying within 200 feet of the boundary of the property
located at:
Address: 2800 VANCE STREET, LITTLE ROCK, ARKANSAS
General Location: VANCE STREET & ROOSEVELT ROAD
Owned by: MOON REALTY COMPANY — 2800 S VANCE STREET
Zoning: 1-2
Proposed Use: WAREHOUSE/DISTRIBUTION FACILITY
NOTICE IS HEREBY GIVEN THAT an application for Site Plan Review has been
filed with the Department of Planning and Development. A public hearing on said
application will be held by the Little Rock Planning Commission in the Board of
Directors Chamber, Second Floor, City Hall on APRIL 3'd at 4:00 p.m.
ALL PARTIES IN INTEREST MAY APPEAR and be heard at said time and
place, or may notify the Planning Commission of their views on this matter by
letter. All persons interested in this request are invited to call or visit the
Department of Planning and Development, 723 W. Markham, 371-4790, and
review the application and discuss same with the Planning Staff.
WAh
THOMAS ENGINEERING COMPANY
civil engineers — -
land surveyors
_7
3810 LOOKOUT RD NORTH LITTLE ROCK, AR 72116 (501) 753-4463 FAX (501) 753-6814
NATIONAL SOCIETY OF PROFESSIONAL ENGINEERS
February 24, 2014
Mrs Donna James
Subdivision Administrator
City of Little Rock Planning and Development
723 West Markham
Little Rock, AR 72201
RE: Site Plan Review
Moon Distribution — Warehouse Expansion
Dear Mrs. James:
Please accept this letter to serve as our application for the above referenced project. We wish to be placed on the
April 3rd, 2014 Planning Commission Agenda.
Moon Distributors, Inc. is proposing to expand its warehouse distribution operation by constructing a new 118,000 SF
facility and would like to construct a new parking facility as shown on the submitted Site Plan. The property is un-
platted and is zoned I-2.
Enclosed please find a check for the Site Plan Review.
If you have any questions, please let me know.
Sincerely,
Thomas R. Pownall, P.E.
Project Engineer
TRP
sitpin.doc
03/01/10
INFORMATION SHEET FOR
SUBDIVISION PUD's PD's, ZONING
OR SUBDIVISION SITE PLAN REVIEWS
ITEMNO.
+^y
FILE NO, J G y r C, --
LOCATION:
DATE 2-1 z4 r 14
DEVELOPER: (AboA ir e-
STREET ADDRESS 2 acA> \JA wv ST��
CITY/STATE/ZIP Lt aoUG A¢►
TELEPHONE NO. 501- 3 929 %
r}J
ENGINEER:
STREET ADDRESS 3$lD Low-w-r t2�DPn
CITY/STATE/ZIP ri o e:gA 1.L-rTLG Wl. Z l (to
TELEPHONE NO. 50k- V03- (+3
AREA �'� OtC "� - NUMBER OF LOTS PIAi'Tren
FT. NEW STREET -p -
ZONING
PLANNING DISTRICT
VARIANCES REQUESTED
1.)
2.)
3.)
4.)
PROPOSED USES W-l-M _ l%-Rbl (1,JTtDN
CENSUS
-J
0
ru
o
Ln -
o
a
o
o =�
a
Ln -
Ln
u,
Er W-- - -
v
Z
O
7J
cn•
z• •—roO
37 3D
1'
O M
U7
m
D
City of Little Rock
Planning and Development
Filing Fees
I)ate ..- ceJy , 20
—i
Annexation
Board of Adjustment
Cond Use Permit/T U P
Final Plat
Planned Unit Dev
Preliminaiy Plat
Special Use Permit
Rezoning
Site Plans
Street Name Change
Street Name Signs
Number at ea
Public Hearing Signs
Number-4—at . �1�� ea
Total
File No
$
Location
Applicant
By