HomeMy WebLinkAboutZ-10087 Action Letter 112124 (2)
Department of Planning and Development
723 West Markham Street
Little Rock, Arkansas 72201-1334
Phone: (501)371-4790 Fax: (501)371-4546
Planning
Development
Building Codes
Mr. Jonathan Hope ____________________ File No: Z-10087
129 North Main St Location: 50 Edgehill Rd
Benton, AR 72015 ____ ___________ Issue: Acc. Structure Front Yard Distance &
Front Yard Setback
Date: December 2, 2024____
Dear _Jonathan Hope .
This is to advise you that in connection with your application, File No. _Z-10087_, the following action
was taken by the Board of Adjustment at its meeting on November 21, 2024_:
(a) ___X __ Approved the application as filed.
(b) Approved the application with conditions.
(c) ___ ____ Denied the application.
(d) ________ Deferred the application to the ________ meeting.
(e) ________ Withdrew the application.
(f) ________ See attached Board of Adjustment minute record for conditions.
(g) ________ Other: ______________________________________________________________
____________________________________________________________________________________
____________________________________________________________________________________
If a variance application is approved by the Board of Adjustment, all permits necessary for the initiation of
work shall be obtained within two (2) years from the date of approval, unless an extension of time is granted
by the Board. Otherwise, the Board’s approval of the application shall be considered void.
According to the City’s Zoning Ordinance Section 36-70:
“Appeals from the decision of the Board of Adjustment shall be filed with the appropriate court of
jurisdiction. This filing must occur within thirty (30) calendar days of the action by the Board of
Adjustment.”
If you have questions, please call me at (501) 371-6821.
Sincerely,
_____________________________________________
Romie G. Price, Plans Development Administrator
RGP/aa
NOVEMBER 21, 2024
ITEM NO.: 7 Z-10087
File No.: Z-10087
Owner: Rhys Branman
Applicant: Jonathan Hope – Hope Consulting (Agent)
Address: 50 Edgehill Road
Legal Description: Lot 48 Edgehill, and addition to the City of Little Rock, Pulaski
County, Arkansas
Current Zoning: R-2
Present Use: Single Family Residential
Proposed Use: Single Family Residential
Variance(s) Requested: Variances are requested for the area regulations of Section
36-156 to allow a retaining wall accessory structure to be less
than 60 feet from the front property line and have a distance
of less than 6-feet from a residence and less than 3-feet from
a side or rear yard property line.
Justification: The applicant’s justification is presented in an attached letter.
STAFF REPORT:
A. Planning and Development Civil Engineering Comments:
No comments.
B. Landscape and Buffer Comments:
In October 2020 the City adopted the “Heights Landscape Design Overlay District,”
requiring installation of one tree per 40 linear feet of street frontage within the
Heights District Boundary, applicable to [among other types] residential
construction in excess of 600 square feet.
C. Building Codes Comments:
No Comments.
NOVEMBER 21, 2024
ITEM NO.: 7 Z-10087
D. Analysis:
The property located at 50 Edgehill Road is currently occupied by a two-story
masonry single-family residence with a lot width of 87-feet along the rear (north)
property line and 108.42-feet along the front (south) property line, and a lot depth
of 155-feet along the west property line and 219.20-feet along the east property
line.
The applicant is proposing to construct a short (4 to 6 feet) retaining wall accessory
structure on the southwest (front yard) corner of the lot, and a high (12 foot)
retaining wall accessory structure along the north (rear) and portions of the east
and west side yard property lines.
The proposed front yard retaining wall accessory structure will be located 19.6-feet
from the front (south) property line. The proposed rear yard accessory retaining
wall structure will be located 3.1-feet from the rear (north) property line and located
3.7-feet from the northwest corner of the existing residence.
Section 36-156(b) states “All single- and two-family residences shall be separated
from accessory structures by a distance of not less than six (6) feet.” Therefore,
the applicant is requesting a variance to allow a retaining wall accessory structure
to be not less than 3.7-feet from the existing residence
Section 36-156(c) states “Accessory buildings or structures in the R-1 through R-
4A districts shall not be located closer than sixty (60) feet to the front property line.”
Therefore, the applicant is requesting a variance to allow an accessory structure
to be not less than 19.6-feet from the front property line.
Staff is supportive of the requested setback variances to install a retaining wall at
the property. Staff views the request as reasonable. The front wall will be located
mainly at the southwestern edge of the property’s front yard area, and the rear wall
will be located along the east, west, and north perimeters of the property. Staff
views this request as minor in nature and believes the reduced setbacks will have
no adverse impact on the surrounding properties.
E. Staff Recommendation:
Staff recommends approval of the requested setback variances to allow the
retaining wall accessory structures to be not less than 19.6 -feet from the front
property line and not less than 3.1 feet from the existing residence, and the
requested variances to allow the reduction of the front yard setback to no less than
19.6 feet and the reduction of the rear yard setback to no less than 3.1 -feet, with
the following conditions:
NOVEMBER 21, 2024
ITEM NO.: 7 Z-10087
1. Obtain a building permit prior to construction.
2. Install trees, if deemed applicable at the time of building permit, in accordance
with the Heights Design Overlay District requirements.
Board of Adjustment (NOVEMBER 21, 2024)
The applicant was present. There were no objectors present. Staff presented the
application to the Board and stated it recommended the reduced front yard and rear yard
setback variances and reduced allowable distance from the front property line and
existing building for an accessory structure variances be approved as per staff report.
There was a consent motion to approve the application. The motion was seconded. The
application was approved on consent. The vote was 5 ayes, 0 nays.