Loading...
HomeMy WebLinkAboutS-1056-B Map 3LOT 1 CWC SUBD 'T P v / �, VICINITY MAP 1 I 279 (5N.T.S. detention pond j ) 07, APPROXIMATE LOCATION OF 30' DRAINAGE / 09C° % EASEMENT LYING 15' ON EITHER SIDE OF concreke=275.25' / / PROPOSED DEVELOPME IGN / �QoQ y THE CENTERLINE OF MANN BRANCH (BOOK IGHT 36', AREA 160 SF �/ QJ 1340, PAGE 375 & BOOK 1378, PAGE 573) V, fl=275.22,-� —_ - -- - 280 / sign 15 parking pace U n 275� dumpster / / asphalt parking 000 CD i kq\ 2112 1 — — L 1 arkin concrete walk II I N CO CU cu _ N I O c3+ I 80.5 rw \ w _ I no II CI o� O C. p° I 5'X5' a a I washroom F G ° I 7'0 covered II ao I o ONconcrete m �' �- EXISTING �♦ co I m 6'9 1 STORY STUCCO I CoI 7 RESTAURANT o ♦ S CC) +_ I fU 8,217 SQ. FT. cn I / I C- LOT 2AR Co Cil o V II 80.7' II m N I � I II I NON I a I q I, m Of Ln o 4.7' =LOT 2BR I 1 d I j L 1200 SF-6 ----------- — — — d d I 2015v2 I --- I 4 4 I I �\ --- L -----I---- ---------- --- -il sign, ---- — 110' UTILITY FASEMENT (PLAT - r PROPOSED DEVELOPMENT SIGN w w MAX HEIGHT 36`, MAX AREA 150 SF concrete walk TEXISTING DRIVEWAY TO BE CLOSED// VJ OVERALL DEVELOPMENT PARKING REQUIRED: 86 PARKING PROVIDED: 88 2) sig-rr--- � —N 87051' 284 signs( bdx signof pole BA S'E'LIN�` R UAD r - - - - a - - - - - -- CRAIN INVESTMENTS LP � I U-1 O I I CJV�° l (� \�(P w H f1 ', Y I QLd ESE\' vi I PVTER�P OC'010� -Lo ZPNK it \MASONARY SCREENED DUMPSTERENCLOSURE 00 O O "VACUUM UNI BASELINE 00 r-0 PROPERTIES, INC. ° O O NOTE: BUILDING AND CANOPY WILL SHIFT WEST IF ALTERNATIVE FUEL TANK LOCATION IS SELECTED. M C Z I a � o c } IL s, J B o signal signal pole —y��Ir III ems— ---7 TAT' HWY. #338) o Z�o EXISTING TRAFFIC SIGNAL signal box NOTES: 1. ADDRESS OF PROPERTY: 10011 INTERSTATE 30, LITTLE ROCK, AR 72209 \ 2. BASIS OF BEARINGS: ARKANSAS STATE PLANE, NORTH ZONE 3. AREA OF PROPERTY: 123,289 SQ. FT. OR 2.830 ACRES +/- 4. NO PORTION OF THIS PROPERTY IS LOCATED WITHIN THE 100 YEAR FLOOD BOUNDARY AS SHOWN ON THE FLOODWAY, FLOOD BOUNDARY AND FLOOD INSURANCE WORK MAP FOR LITTLE ROCK, ARKANSAS. THIS PROPERTY LIES IN ZONE X. (FIRM COMMUNITY PANEL # 05119CO442G, JULY 6, 2015) I P S Zca3 5. ZONING OF PROPERTY: C-4 (OPEN DISPLAY COMMERCIAL) -Height regulations. No building hereafter erected or structurally altered shall exceed a height of thirty-five (35) feet. LEGAL DESCRIPTION (DEED NO. 2007000513)) LOT 2, CWC SUBDIVISION TO THE CITY OF LITTLE ROCK, PULASKI COUNTY, ARKANSAS, AS SHOWN ON PLAT RECORDED AS PLAT NO. E-334. NOTE: THE PLAT OF CWC SUBDIVISION REFERENCED ON THIS SURVEY IS RECORDED IN PLAT BOOK E, PAGE 322, PULASKI COUNTY, ARKANSAS. THE DEEDED DESCRIPTION SHOWS THE PLAT TO BE FILED IN BOOK E, PAGE 334, PULASKI COUNTY, ARKANSAS. EEI R1 \ co rU signal box signal pole I / / Prel Plat Notes: 1. DEVELOPER: MURPHY USA 422 NORTH WASHINGTON ELDORADO, AR 71730 PHONE: (870) 875-7629 2. Linear feet of Internal Streets: 0 Lf 3. Average Size of Lot: 170' x 300' 4. Number of Lots: 2 Lots 5. Applicable existing covenants: None 6. Source of Water Supply: CAW 7. Source of Wasterwater Disposal: LRWWU 8. Variances: 9. Municipal Boundaries: Inside Corporate City Limits OF AU; _- Sp9 it Site Plan Notes: `w' WHITE OCIIATES'`=_o 3 V ° INC. = z 1. HOURS OF OPERATION: 24HRS DAY #538 DAYS A WEEK 99�9•.,, '�Q, 2. ALL SIGHT LIGHTING SHALL BE LOW-LEVEL AND DIRECTIONAL, DIRECTED AWAY FROM RESIDENTIAL PROPERTY. 3. HOURS OF GARBAGE COLLECTION: 7:00 AM - 6:00 PM, MON-FRI 4. MAXIMUM BUILDING HEIGHT = 35 FT. 5. DUMPSTER TO BE SCREENED WITH 8' TALL OPAQUE SCREENING 6. AN IRRIGATION SYSTEM TO WATER LANDSCAPED AREAS WILL BE PROVIDED. X LEGEND water valve fire hydrant ® water meter r z rpz electric transformer © electric box m fiber-optic sign © - - gas meter - buried gas marker -� - power pole guy wire light pole yc ground light + 0 bollard pole sanitary sewer manhole C sewer or drain clean -outs Q telephone riser Ot telephone sign cable riser ® junction box -drainage 101 curb inlet -drainage ---® grate inlet -drainage rcp reinforced concrete pipe cmp -_.Q-- corrugated metal pipe sign 'y handicap parking H.C. handicap ramp concrete fence -- — overhead power (ug) underground electric (ug) underground gas (ug) underground fiber optic (ug) underground telephone (ug) underground water (ug) underground sewer SIP- SET 1/2" IRON PIN W/ CAP 128D CERTIFICATE OF PRELIMINARY SURVEYING ACCURACY 1, Paul M. White, hereby certify that this plat correctly represents a bound- ary survey made of verified by me that all surveying requirments of the State of Arkansas and City of Little Rock Sub- \vv��U1i;3TE�iii division Rules and Regulations have been compiled with and a copy of said �� ,s° STATE OF boundary has been duly filed for record = NARKANSAS42 in offices of the State Surveryor and the Pulaski County Circuit Clerk on 20—, in Plat Book _Page 02-06-20171nm0\ Date of Execution Daniel W. Havner, Registered Land Surveryor No. 1542, Arkansas CERTIFICATE OF PRELIMINARY ENGINEERING ACCURACY ll��ds� ARKANSAS `. 'll I, Timothy E. Daters, hereby certify �01 REGISTERED that this plat correctly represents a PROFESSIONAL plat made by me, and that engineerint requirements of the Little Rock �� ENGINEER Subdivision Rules and Regulations have�� have been compiled with. TIMOTHY E. DATRRS O No. 5033 ll 02-06-2017 Date of Execution Timo by E. Daters Registered Professional Engineer No. 5033, Arkansas OWNER OR DEVELOPER Date of Execution Name OWNER OR DEVELOPER Date of Execution Name Address Source of Tile D.R. Page Instrument No. CERTIFICATE OF PRELIMINARY PLAT APPROVAL All requirements of the Little Rock Subdivision Rules and Regulations relative to the preparation and submittal of a preliminary plat having been fulfilled, approval of this plat is hereby granted, subject to further provision of said Rules and Regulations This certificate shall expire. Date of Execution Planning Administrator Public Works Notes: 1. NPDES and grading permits are required prior to construction. 2. Stormwater detention ordinance does not apply to this property. 3. Plans of all work in right-of-way shall be submitted for approval prior to start of work. 4. Provide striping and signage plans as per ordinance for Traffic Engineering approval. 5. Prior to construction obtain barricade permit for work done within right-of-way. 6. Easements are for utilities and drainage where needed. 7. A grading permit per secs. 29-186(c) and (d) will be required with a building permit. PRELIMINARY PLAT & SITE PLAN REVIEW LOTS 2AR & 2BR 0 6 2017 Revised Revised 3-5-17 Date 2-5-17 scale Hor. Vert. Sheet wt 1)b N). 16-4288 © WHIIE-VA 1 EKS & A SSOC'IATES, INC. CIVIL ENGINEERING, LAND PLANNING .c DEVELOPMENT, SURVEYING 0 24 RAHLING CIRCLE LITTLE ROCK, F RKANSAS 72223 PH. 501-821-1667 FAX. 501-821-1668 CWC SUBDIVISION Little Rock, Pulaski County, Arkansas