E. ANALYSIS:
Other than the applicant needing to furnish a site plan
which is fully dimensioned, there,Are no issues to be
resolved. The site is a large tract, and the buildings have
more than adequate separation from each other and from
property lines.
F. STAFF RECOMMENDATIONS:
Staff recommends approval of the site plan.
SUBDIVISION COMMITTEE COMMENT: (MARCH 16, 1995)
Mr. Joe Stout was present to represent the applicant. Staff
presented the proposal and reviewed with Mr. Stout the various
comments contained in the discussion outline. The Committee
members discussed the site plan with the applicant, and confirmed
.with the applicant that all staff comments would be addressed.
The Committee forwarded the site plan to the full Commission for
the public hearing.
PLANNING COMMISSION ACTION: (APRIL 4, 1995)
The item was included on the Consent Agenda for approval, and
was approved with the vote of 9 ayes, 0 nays, 0 abstentions, and
2 absent.
3
April 4, 1995
ITEM NQ.= 11 FILE NO.: S-1054
NAME: HANDLING SYSTEMS & CONVEYORS, INC. -- SITE PLAN REVIEW
LOCATION: On the East Side of Otter Creek East Blvd., at 10909
Otter Creek East Blvd.
DEVELOPER:
Mark Akers
HANDLING SYSTEMS AND CONVEYORS, INC.
10909 Otter Creek East Blvd.
Mabelvale, AR 72103
455-5898
AREA: 2.29 ACRES NUMBER OF LOTS: 1 FT. NEW STREET: 0
ZQUIN I-2 PROPOSED USES: Industrial
PLANNING DISTRICT: 16
CENSUS TRACT: 41.03
VARIANCES REQUESTED: None
The applicant proposes the addition of a second building to its
current office site. The proposed building is to have 12,000
square feet "under roof". Half the building is to be enclosed;
the remainder of the roof is to form a canopy over a concrete
slab area. The new building is to be constructed approximately
27 feet behind the existing office building. The internal .drive
and parking area is to be extended to serve the new building,
with new parking to be added to provide a total of 16 parking
space, including handicap parking. Landscaping will be upgraded
to meet the City requirements. No new drive access points from
Otter Creek East Blvd. will be added; the existing access points
will continued to be used.
A. PRQPQ AL RE BEST :
Planning Commission approval of a multi -building site plan
is requested.
B. EXISTING CONDITIONS:
There is an existing one and one-half story residential
structure on the property which contains approximately 2,330
square feet on its first floor level.
ApYil 4, 1995
SUBDIVISION
ITEM NO : 11 _ (Cont.) - FILE-,NQ_T.�; 5-1054
The property is zoned I-2, with I-2 zoned property on all
abutting properties.
C. ENGINEERING/UTILITY COMMENTS:
Public Works Comments:
1) A grading permit will be required.
2) A stormwater detention analysis will be required.
Water Works has no comments on this item.
Wastewater comments that sewer is available, and that there
will be no adverse effect if project is for a single owner.
If two owners are involved, a sewer main extension, with
easements, will be required.
Arkansas Power and Light Co. comments that a 15 foot wide
easement will be required along the north property line, and
a 20 foot easement will be required along the east property
line.
Arkansas Louisiana Gas Co. approved the submittal without
comment.
Southwestern Bell Telephone Co. approved the submittal
without comment.
The Fire Department approved the submittal without comment.
D. ISSUES LEGAL TECHNICAL DESIGN:
The "Site Plan Review Criteria" sheet provided with the
application requires the following information be furnished,
which has not been shown on the site plan: dimensions of
all existing and proposed buildings; dimensions of buildings
from property lines and from each other; the radii of all
drive lanes, curves, or turns; and, dimensions of all
drives. All drives and streets intersecting all boundary
streets across from the site are to be indicated and
dimensioned. The required information is incomplete and
needs to be furnished.
Landscape review has no comments on this item.
Sec. 31-13 requires site plan review for projects involving
construction of 2 or more buildings on a site.