HomeMy WebLinkAboutS-0983-B Staff AnalysisOctober 18, 1994
Mo oaa& l
FILE NO.: S-983--5
NAME: BRENNAN ADDITION, TRACT A -- SITE PLAN REVIEW
LQfATI-Q On the north side of White Rock Ln., approximately 0.2
mile east of Reservoir Rd.
DEVELOPER: ENGINEER:
ABE ROSEN WHITE-DATERS & ASSOCIATES, INC.
A. S. ROSEN & ASSOCIATES, INC. 401 S. Victory St.
9101 Rodney Parham Rd. Little Rock, AR 72201
Little Rock, AR 72205 374-1666
223-0647
AREA: 0.7615 ACRES DER OF LOTS: 1 FT. NEW STREET: 0
ZONING: R-5 PROPOSED USES: Multi -Family Residential
PLANNING DISTRICT• 3
CENSUS TRACT: 22.03
VARIANCES REOQESTED: None
STATEMENT OF PROPOSAL:
The applicant proposes the development of a 0.7615 acre lot in a
R-5 zoning_ district consisting of the construction of 12
apartment units in 2 buildings. Parking for 20 vehicles on the
property is proposed. No variances are requested.
A. PROPOSAWREOUEST:
Approval of the Planning Commission is requested for a site
plan involving the construction of 2, 2-story apartment
buildings, each containing 6, 1-bedroom apartments, for a
total of 12 units on the 0.7615 acre site.-. Each building
is proposed to contain 3,420 square feet. Parking for 20
vehicles on the premises is provided. The required "good
neighbor" fence is proposed to be erected along the west
property line abutting the single-family lots. Along the
Grassy Flat Creek boundary, however, no fence is proposed.
B . EXISTING -CONDITIONS:. - -
The site is one of the lots in the recently approved Brennan
Addition, and this lot was rezoned to R-5 at the time. The
remaining lots in Brennan Addition were retained for single-
family development and face Brennan Ln. The lot being
developed for multi -family use faces White Rock Ln., and has
October 18, 1994
SUBDIVISION
ITEM N n inu d FILE ND.: -
-H
two Brennan Addition single-family lots abutting it along
its west property line. There are other multi -family
developments across White Rock Ln. to the south. To the
east, bordering the site, is the floodway for Grassy Flat
Creek. The site has_ been. cleared, and Is prepared for
development.
The site is zoned R-5. To the north and west is R-2 zoned
property. Across 'White Rock Ln. to the south is property
zoned MF-24. At the southwest corner of the tract is an 0-3
zoned parcel. To the east is the Grassy Flat Creek
floodway, with R-2 land beyond.
C. EN INERRIN TILIT3C C MMENTS:
Public Works comments that prior to issuance of a building
permit, a complete grading and drainage plan and a
stormwater detention plan must be submitted. One-half
street improvements on White Rock Ln. must be constructed.
Little Rock Water Works comments that an additional fire
hydrant may be required by the Fire Department.
Little Rock Wastewater Utility comments that sewer is
available, and that there will be no adverse effect on the
Utility system in providing service.
Arkansas Power and Light Co. will require easements along
the west'and south property line
Arkansas Louisiana Gas Co. approved the submittal without
comment.
Southwestern Bell Telephone Co. approved the submittal
without comment.
The Little Rock Fire Department approved the submittal
without comment.
Landscape review comments that a 6 foot high opaque wood
fence, with its structural members facing toward the site,
or evergreen plantings, will be required along the western
and eastern property line which abut the single-family
residential areas. Areas set aside for land use buffers and
landscaping areas are below minimum ordinance requirements.
The western and eastern land use buffers must be a minimum
of 6 -feet- in width." __A - total " o f " 6% of' the interior of the
vehicular use area must be landscaped.
D. I E LE AL TE H I AL DE I
Section 31-13 of the Subdivision Regulations requires site
plan review for developments involving the construction of 2
2
October 18, 1994
SUBDIVISION
ITEM N n zn d FILE N _
or more buildings on a lot. The proposed development
involves construction of 2 apartment buildings on the lot;
therefore, site plan review pursuant to the Subdivision
Regulations is required.
Section 36-259 of the Zoning Regulations permits high
density multi -family uses, with a density of not more than
36 units per acre. For lots ranging in size of from 10,000
square feet to 1 acre, there shall be provided 2,000 square
feet of land area per dwelling unit. The proposed
development involves construction of 1.2 units on 33,171
square feet of land area. To meet the R-5 requirements 12
dwelling units require 24,000 square feet of land area;
therefore, this requirement is met. The development
involves the construction of 12 units on 0.7615 acres_ This
represents 15.76 units per acre; therefore the development
meets the ratio of the units per acre required by the
Regulations for the development in the R-S zoning district.
Section 36-502 of the Zoning Ordinance requires that multi-
family developments provide 1.5 parking spaces per dwelling
unit. The proposed development proposes 1.2 dwelling units,
requiring 18 parking spaces. Parking for 20 vehicles is
Proposed for the development; therefore, the number of
parking spaces meets Ordinance requirements.
The site plan submitted for review must include the
fallowing item which were not included with _this. -
application: 1) information on the availability of public
utilities; 2) existing and proposed fire hydrants; 3) the
designation of landscape areas; and;-4) the location of
sidewalks.
-The-head-in parking spaces off White Rock Ln. are not
acceptable as presented. A parking 'Ilot" with a_20 foot
wide drive -approach and necessary maneuvering space for
access to and from parking spaces_ is.required. .__Backing
-directly-onto White Rock Ln. is not acceptable.
E. ANALYSIS:
There are encroachments into the land use buffers, and
landscaping in the vehicular use are is deficient.
Landscape areas are not shown. Walkways are not shown. The
parking area at the southeast corner of the property is
improperly designed. The development, however, meets the
density- requi-rement'-for 'the 'R=5 'Zori_Ing � district; so, with
some modification to the site plan, the development can meet
the requirements.
3
October 18, 1994
SUBDIVISION
ITEM NQ.: 2 (Continued) FILE Nib.: 5-983 B
F. ZTAFF RECOMMENDATIONS:
Staff recommends approval of the site plan, subject to the
site plan being amended to incorporate the needed changes as
cited above.
,5�IBDIVISIQA COMMITTEE COMMENT:
(SEPTEMBER 29, 1994)
Mr. Joe White, representing White-Daters & Associates, Inc., the
project engineering firm, was present. Staff outlined the
proposal, and the Committee reviewed with Mr. white the comments
contained in the discussion outline. Mr. White indicated that he
would meet with Bob Brown, the staff person responsible for
landscape review, to clarify the requirements for meeting the
land use buffer requirements. He indicated that he ought to be
able to meet the requirements for both minimum and average width
of the buffers. He also mentioned that, with the width of the
Grassy Flat Creek floodway, and the distance to the east to any
residential uses, that the land use buffer along the creek should
be waived. Mr. White stated that the parking area at the
southeast corner of the project would be redesigned to comply
with the Ordinance requirements. The Committee forwarded the
item to the Planning Commission for final approval of the site
plan.
PLANNING COMMITOUACTION:
(OCTOBER 18, 1994)
Staff reported that there were no outstanding issues -to be
resolved, and recommended approval of the site plan, as amended
by the applicant. The item was included on the Consent Agenda
for approval. -The item was approved with the approval of the
Consent Agenda with the vote of 9 ayes, 0 nays, 1 absent, and
1 abstention (Putnam).
4