Loading...
HomeMy WebLinkAboutZ-10027 Plan Details 0625249'-1 1/8"10'-1 1/8"ARCHITECTURAL ASPHALT SHINGLES SYNTHETIC ROOFING UNDERLAYMENT 1/2" ZIP BOARD TAPED AT JOINTS RAFTER PER CODE KNEE WALL R-38 INSULATION SUB-FASCIA FASCIA CEILING JOIST PER CODE 2"X4" WALL PLATE HEADER CAST STONE TRIM ALUM.-CLAD WOOD WINDOW COFFERED CEILING 3 1/2" R-15 BATT INSULATION 1/2" ZIP BOARD TAPED AT JOINTS 2"X4" STUD WALL FLOOR TRUSS 2"X4" WALL PLATE BRICK VENEER HEADER CAST STONE TRIM ALUM.-CLAD WOOD WINDOW 2"X4" SILL PLATE "L" BOLT CMU BLOCK FOUNDATION SLOPE FOR DRAINAGE CONCRETE FOOTING 24"W X 16"D VERIFY W/STRUCTURAL & SOILS ENGINEERS CONT. REBAR AS REQ. CROWN MOLDING 5/8" GYP. BOARD INT. RECESSED LIGHT 1/2" GYP. BOARD WINDOW TRIM ALUM.-CLAD WOOD WINDOW BASEBOARD FINISH FLOORING 4" CONC. SLAB 15 MIL STEGO WRAP VAPOR BARRIER CRUSHED STONE FILL COMPACTED SOIL GOLF SIM. SITTING ROOM ATTIC TYPICAL WALL SECTION 3/8"=1'PROJECT TITLECONTENTSDETAILSDATESHEETA 7.1GENERAL FRAMING NOTES: 1. 2. THE CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK AND CONSTRUCTION MEETS OR EXCEEDS ALL CURRENT FEDERAL, STATE & LOCAL CODES, ORDINANCES AND REGULATIONS, ETC. THESE ARE TO BE CONSIDERED AS PART OF THE SPECIFICATIONS OF THE BUILDING AND SHOULD BE ADHERED TO EVEN IF THEY ARE IN VARIANCE WITH THE PLAN. THE STRUCTURAL DATA SHOWN ON THE PLAN IS FOR REFERENCE ONLY. GENERAL CONTRACTOR IS TO HAVE A LICENSED STRUCTURAL ENGINEER REVIEW ALL STRUCTURAL ELEMENTS SUCH AS JOIST SIZE & SPACING, BEAM AND HEADER SIZES, BEAM CONNECTIONS, ETC. *VERIFY FINAL SIZES WITH JOIST & BEAM MANUFACTURER. GENERAL FRAMING NOTES: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. ALL WOOD FRAMING IN CONTACT WITH CONCRETE OR MASONRY TO BE PRESSURE TREATED. ALL STUD WALLS TO BE FRAMED 16" O.C. ALL ANGLED WALLS TO BE FRAMED AT 45 DEGREE ANGLE UNLESS OTHERWISE NOTED. MINIMUM HEADER SIZE AT SECOND AND THIRD FLOORS TO BE (2) 2x6'S UNLESS OTHERWISE NOTED. PROVIDE FULL SOLID BEARING OR STUD BEARING UNDER ALL BEAM BEARING POINTS. ALL BEAMS TO HAVE TRIPLE STUD BEARING AT EACH END. ALL STRUCTURAL STEEL TO CONFORM WITH ASTM SPECIFICATIONS A-36. STAIR CONSTRUCTION TO CONSIST OF (3) 2x12 STRINGERS, 5/4" OR 2x THICK TREADS & 3/4" THICK RISERS OR MATERIALS FABRICATED BY A COMPONENT MANUFACTURER. HANDRAILS TO BE MOUNTED 32"-34" ABOVE STAIR NOSING. GUARDRAILS TO BE MOUNTED AT 36" HEIGHT. FLOOR FRAMING LAYOUT TO BE COORDINATED WITH THE GENERAL AND HVAC CONTRACTORS TO PROVIDE ACCESS CHASES AND UNOBSTRUCTED RUNS FOR HVAC DUCT WORK.5607 COUNTRY CLUB BLVD4/6/24