HomeMy WebLinkAboutZ-10027 Design Plans 062524SB5321SB4221
SB30213DB26211DB392016 1DB392016
SB60L
SB36B27LLCB36RB27RB39B39SB36B96DW3DB12ICEB28 MICRO B28
3DB15B30 B53GRILLU/C REFB45L
BCB30RB36SB36
B30 ICEB30SB25R B30BUILT-INSBUILT-INS3DB2621SB5321SB4221
SB30213DB26211DB392016 1DB392016
SB60L
SB36B27LLCB36RB27RB39B39SB36B96DW3DB12ICEB28 MICRO B28
3DB15B30 B53GRILLU/C REFB45L
BCB30RB36SB36
B30 ICEB30SB25R B30BUILT-INSBUILT-INS3DB2621LINENLINENU722599U242699RU242699L
ARCHED
BUILT-INS
W3980 W3980
W2742RW3942W3942W2742LW3518W2842 W2842W2842
W4542BCW4542W2742R BCW2742L
W361515 W3636
W4860W4860W5236W5236W52362670SC2670SC2670SC2670SC3070SC3070SC2670SC2670SC2670SC2670SC
5480
ARCH 5480 ARCHED2480
5480 ARCHED 2880 ARCHED
5480 ARCHED3070SC3070SC54802030FX3070SC3070SC908090802880
5080ARCHED5080ARCHED12884 12880
3040FX5080
ARCHEDLOCKERS
2880
3040FX2670SC 2670SC
10080
NANAWALL
3080 ARCHED2480
2880
20802480 24802880ARCHED3080
3080
411844118426802480
2880
2480
5792ARCHEDGAS FIREPLACEGAS FIREPLACEUP
cL
cL cLcLcL
E1
6
E1
6Exterior Elevation Front
E2
7
E2
7
Exterior Elevation LeftE3
6
E3
6
Exterior Elevation Back
E4
7
E4
7
Exterior Elevation RightWS1
8
WS1
8WALL SECTION
5'-8"26'-0 1/2"2'-10"2'-10"2'-9 1/2"10'-5"2'-9 1/2"3'-10"5'-10"3'-2"3'-2"7'12'10'-8"2'-4"11'4'-8"6'-3"6'-3"9'11'-6"3'-6"3'-6"4'-6"2'-6"7'-6"2'-6"3'-6"
9'11'-6"7'20'-6"4'-4"
55'
2'-8"
1'-6"13'-4"13'-4"9'12'-6"3'9'-8"6'-4"32'15'-8"101'-6"2'-4"15'-4"3'-8"8'
55'
6'-8 3/4"13'-9"7'-0 1/4"
27'-6"
2'-8"3'-1 1/2"2'-10"5'-11 1/2"6'5'-8"16'7'-2"6'-4"7'54'-1 1/2"5'-2"1'-10"5'-6"7'3'-2"31'-8 1/2"2'-4"3'-8"
4'-4"
5'-10"2'-6"4'3'-4"12'-4"15'-2"11'6'-7 1/2"3'
3'13'-4"11'3'-4"1'-4"7'-7"2'2'3'-4"1'-4"4'-8"13'-4"23'-2"17'-7 1/2"12'
7'-9 1/2"4'-2 1/2"9'-3 1/2"7'-10"6'-0 1/2"4'-10"
3'-4"
3'-4"6'-4 1/2"6'-10"3'-9 1/2"
27'3'1'-7 1/2"5'-0 1/2"1'-7 1/2"101'-6"2'-4"106'-2"4'-8"4'-8"106'-2"9'-4"8'-4"11'2'-8"15'-6"6'-4"47'-4 1/2"27'27'-6"10'-2"7'-4"8'-6 1/2"26'-4" X 31'-8"
10'-10" X 13'-0"
11'-8" X 6'-8"
6'-11" X 10'-8"
8'-0" X 13'-2"
13'-7" X 16'-7"
15'-4" X 22'-6"
16'-4" X 6'-3"
12'-0" X 15'-4"
8'-8" X 6'-8"
7'-5" X 7'-5"
11'-4" X 11'-10"
4'-6" X 8'-10"
18'-4" X 15'-0"
13'-3" X 16'-7"
12'-11" X 22'-6"
4'-6" X 2'-11"
7'-8" X 9'-10"
2'-7" X 5'-7"
7'-8" X 4'-10"
2676 SQ FT
FOYER
GUEST BEDROOM 4
SITTING
PORCH
LIVING
KITCHEN
PORCH
GOLF SIM
CLOSET
BATH
GARAGE
SAFE ROOM
PANTRY
CLOSET
GUEST BATH
OUTDOOR LIVING
OUTDOOR KITCHEN
CL
TLT
BUFFET/ CABINETSMUD/ BREEZEWAY
W/D
COMBO
LIVING AREA
REF
FREEZERCOFFERED
CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING
10' CEILING10' CEILING
2"x6" WALL
2"x6" WALL
COFFERED
CEILING
COFFERED
CEILING
8" CMU BLOCKS W/ CONC. FILL &
5/8" REBAR CONT. EVERY CELL
1 1/2" FURRING
SHOWER
SHOWER
19'-10" X 13'-0"
REF
DINING
DN
DN 3DB29213DB32 3DB32
SB2721RSB2721L3DB24213DB24213DB24213DB2421U/CREFB50B48LCB42R
LCB42LSB27RSB3021SB31213DB2921KNEE SPACE3DB12213DB12213DB12213DB1221B15R3DB42213DB42213DB42213DB4221WINDOW SEAT
SB30ICE3DB21WET BAR 3DB21
B33B33B33B333DB29213DB32 3DB32
SB2721RSB2721L3DB24213DB24213DB24213DB2421U/CREFB50B48LCB42R
LCB42LSB27RSB3021SB31213DB2921KNEE SPACE3DB12213DB12213DB12213DB1221B15R3DB42213DB42213DB42213DB4221WINDOW SEAT
SB30ICE3DB21WET BAR 3DB21
B33B33B33B33CABINET
U272490RU272490LCABINETLINENLINENCABINETCABINETSHOES
CABINETW3360W3360W3360W3360BCW4536W4636W3636 BCW4536BCW3636 BCW3636 W45363040FX3060FX20403060SC3060SC3060SC3060SC3060FX3020FX 2860FX 2860FX 2860FX
248024803040FX3060SC5060MU
5460MU
2660SC2660SC 3040FX28802880
28802080
2880
26802880
7050FX 548026802880
208040803060SC3060FX3060FX3060SC3060SC248026803020FX2860FX2860FX2860FX308048804080268026802480488028802468288028802880cLcLcL2'-2"2'-8"2'-8"2'-2"3'-10"5'-10"3'-2"3'-2"4'-8"2'-10"5'-6"8'-4"2'-6"5'-10"6'-8"6'-8"4'-8"3'2'-6"8'-6"
2'-4"
14'6'-6"7'6'-6"14'4'-4"
55'
2'-8"
3'
1'-6"13'-4"4'-8"4'-4"6'-3"6'-3"13'-4"9'12'-6"3'9'-8"6'-4"7'-6"16'-4"23'-10"101'-6"2'-4"2'-8"2'-8"2'-8"2'-8"8'8'-4"
10'-8"16'-4"
55'
3'
4'-7"7'-11"3'3'3'6'
27'-6"
2'-8"2'-3 1/2"6'-3"4'-4"3'-4"14'-8"6'-3"5'-8 1/2"5'-11 1/2"5'-4"8'-6 1/2"7'-8"14'-8"54'-1 1/2"8'-7"8'-7"17'-2"6'-8"8'-6 1/2"9'-8"4'-3"1'-1"2'-4"2'-8"
8'-4"4'-4"
23'3'-4"
4'-4"
9'11'14'-8"4'-4"5'-4"6'-6 1/2"5'-4"8'-4"4'-4"14'-10"8'7'-6"7'-8"3'-8"4'-4"5'-8"11'8'3'-4"
5'-8"4'-4"4'-3"6'5'-9 1/2"10'-8 1/2"6'-8"9'4'-4"5'-8"
8'
11'-4"15'-8"
3'
6'
26'-0" X 16'-10"
3432 SQ FT
13'-0" X 7'-8"
13'-0" X 6'-8"
11'-0" X 28'-9"
8'-4" X 7'-4"
13'-8" X 14'-4"
6'-11" X 10'-8"13'-8" X 14'-4"
18'-5" X 17'-5"
11'-0" X 15'-2"
5'-10" X 11'-6"
12'-4" X 8'-2"
8'-0" X 7'-4"
5'-10" X 14'-4"
3'-0" X 5'-0"
16'-0" X 16'-6"
15'-0" X 17'-3"
7'-4" X 7'-2"
4'-0" X 5'-7"
15'-0" X 16'-0"
8'-0" X 5'-0"
10'-0" X 23'-2"
6'-2" X 9'-0"
4'-0" X 6'-2"
9'-2" X 6'-8"
5'-4" X 7'-6"
34'-8" X 5'-8"
9'-2" X 6'-3"
OPEN BELOW
OPEN BELOW
GYM
PLAYROOM
BEDROOM 3
BEDROOM 2
CLOSET
CLOSET
STORAGE/ BONUS
MASTER BDRM
HER CLOSET
SITTING ROOM
MASTER
BATH
CRAFT
TLT
HIS CLOSET
HALL
LANDING
LAUNDRY
BATH 3 BATH 2
CL
HALL
RAILING
LIVING AREA
SAUNA
2"x6" WALL
6' TUB
SHOWER
GLASS
COFFERED
CEILING
TLT.
GLASS
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
9' CEILING
20'-7" CEILING
2"x6" WALL
2"x6" WALL
COFFERED
CEILING
CANTILEVERED
UTILITY CLOSET
FUTURE OFFICE
SHOWER tub/ SHOWER
KNEE SPACEKNEE SPACE
1 LEVEL 2 W/OVERLAY
3/16" = 1'-0"PROJECT TITLECONTENTSFLOOR PLAN LEVEL 1 & 2DATESHEETA 2.0GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
DO NOT SCALE DRAWINGS. FOLLOW DIMENSIONS ONLY. IF DIMENSION
IS NOT CALLED OUT, VERIFY DIMENSION WITH DESIGNER.
ALL INTERIOR WALLS TO BE COVERED WITH 5/8" GYPSUM BOARD,
WITH METAL CORNERS REINFORCING. TAPE, FLOAT & SAND.
ALL BATH & TOILET AREA WALLS AND CEILINGS ADJACENT TO WET
AREAS TO HAVE WATER RESISTANT GYPSUM BOARD.
BEDROOM WINDOWS TO HAVE A MINIMUM NET CLEAR OPENING OF 5.7
SQ. FT., A MINIMUM NET CLEAR OPERABLE WIDTH OF 20", A MINIMUM
NET CLEAR OPERABLE HEIGHT OF 24" AND HAVE A MAXIMUM FINISH
SILL HEIGHT OF 44" FROM FINISH FLOOR.
ALL GLASS LOCATED WITHIN 18" OF FLOOR, 24" OF A DOOR OR
LOCATED WITHIN 60" OF FLOOR AT BATHTUBS, WHIRLPOOLS OR
SHOWERS TO BE TEMPERED.
BATHROOMS, UTILITY ROOMS, AND RANGE HOODS TO BE VENTED TO
THE OUTSIDE AS REQUIRED BY CODE.
ALL INTERIOR & EXTERIOR STUDS TO BE 2X4, UNLESS OTHERWISE NOTED.
ALL EXTERIOR WALLS CONTINUOUSLY SHEATHED W/ 1/2" OSB BOARD
AND VAPOR BARRIER. VENEER SHOULD BE BEHIND ALL SETBACK LINES.
GC TO COORDINATE ALL DOOR & WINDOW OPENING SIZES WITH
SELECTED MANUFACTURER(S).
GENERAL HVAC SYSTEM NOTES:
1.
2.
3.
4.
MECHANICAL SUBCONTRACTOR IS RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
HVAC SUBCONTRACTOR TO FULLY COORDINATE ALL SYSTEM
DATA AND REQUIREMENTS WITH THE EQUIPMENT SUPPLIER. HVAC
SUBCONTRACTOR TO PROVIDE FINAL SYSTEM LAYOUT DRAWINGS
AND SUBMIT IT TO CONTRACTOR, OWNER AND EQUIPMENT
SUPPLIER FOR FINAL REVIEW AND APPROVAL
PROVIDE DUCTING FOR ALL EXHAUST FANS, THE VENT-A-HOOD,
AND THE DRYER VENT.
LOCATE UNITS AS SPECIFIED BY HVAC SUBCONTRACOR.
GENERAL PLUMBING NOTES:
1.
2.
3.
4.
5.
PLUMBING SUBCONTRACTOR TO BE RESPONSIBLE FOR
ADHERING TO ALL APPLICABLE CODES AND SAFETY
REQUIREMENTS.
PROVIDE GAS SERVICE TO ALL WATER HEATERS AND HVAC
EQUIPMENT AS REQUIRED.
IF WALL PLATES OR JOISTS ARE CUT DURING THE INSTALLATION
OF PLUMBING FIXTURES OR EQUIPMENT, PROVIDE BRACING TO
TIE FRAMING BACK TOGETHER.
ALL GAS WATER HEATERS TO BE VENTED ATO TOPOUT.
ALL PLUMBING AND MECHANICAL VENT STACKS TO BE LOACTED
BY LICENSED CONTRACTORS. IF CHASES ARE REQUIRED, NOTIFY
DESIGNER PRIOR TO START OF CONSTRUCTION.
1 LEVEL 1
3/16" = 1'-0"
MAIN LEVEL H/C
SECOND LEVEL H/C
TOTAL H/C
2676 SF
3432 SF
6108 SF
470 SF
590 SF
860 SF
8028 SF
BONUS AREAS
TWO CAR GARAGE
PORCHES
TOTAL UNDER ROOF 5607 COUNTRY CLUB BLVD4/6/24
UP
R6
R6
R6
R6R6
R6
R6 R6
R6
R6
R6R6
R6
R6 R6
R6
R6
R6
R6
R6
R6
R6
R6
R6 R6
R6 R6
R6
R6 R6
R6R6
R6
R6
R6
R6
R6
R6
R6
R6 R6
R6
R6
R6R6
R6
R6R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6R6
R6
R6
R6
R6
R6 R6
R6
R6
R6 R6R6 R6 R6
R6 R6R6
R6 R6R6
R6
10'-0"
2"x6" WALL
2"x6" WALL
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
10'-0"10'-0"
10'-0"
10'-0"
10'-0"
10'-0"
20'-7"
SURFACE MOUNTED LIGHT
INT. RECESSED LIGHT
VANITY LIGHT
EXHAUST FAN
LINEAR SHOP LIGHT
GYP. BOARD TYP.
WALL SCONCE
STAINED T&G CEILING
CEILING FAN
RECESSED LIGHT
GYP. BOARD TYP.
INT. RECESSED LIGHT
CEILING FAN
SURFACE MOUNTED LIGHT
VANITY LIGHT
EXHAUST FAN
WALL SCONCE
VANITY LIGHT
INT. RECESSED LIGHT
SURFACE MOUNTED LIGHT
GYP BOARD TYP.
CEILING FAN
CHANDELIER
SHOWER
DN
DN
R6
R6R6
R6 R6 R6 R6
R6R6
R6
R6
R6
R6R6R6R6R6
R6
R6
R6
R6
R6
R6 R6
R6
R6R6
R6 R6
R6
R6
R6
R6
R6
R6R6
R6R6
R6R6
R6 R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6
R6R6
R6 R6
R6R6
R6 R6
R6
R6R6
R6
R6
R6
R6 R6R6
R6 R6
R6 R6R6
R6 R6
R6R6
R6R6
R6
R6
R6
R6
R6
R6
R6
R6R6
R6
R6
R6
R6
R6
2"x6" WALL
2"x6" WALL
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
20'-7"
9'-0"
9'-0"
20'-7"
ELECTRICAL SCHEDULE
DESCRIPTION
2D
SYMB
OL
CLASSIC CEILING FAN
EXHAUST FAN
LOWE WALL SCONCE
RECESSED DOWN LIGHT 6
SHOP LIGHT (LONG) [72W]
TRADITIONAL FLUSH DOME
WALL SCONCE 3
WROUGHT IRON CANDELABRA
R6R6
INT. RECESSED LIGHT
VANITY LIGHT
CEILING FAN
GYP. BOARD TYP.
EXHAUST FAN
SURFACE MOUNTED LIGHT
GYP. BOARD TYP.
INT. RECESSED LIGHT
EXHAUST FAN
CEILING FAN
VANITY LIGHT
tub/ SHOWER PROJECT TITLECONTENTSREFLECTED CEILINGPLANDATESHEETA 3.0GENERAL ELECTRICAL NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
ELECTRICAL PLANS, IF INCLUDED, ILLUSTRATE BASIC DESIGN INTENT
ONLY. ELECTRICAL CONTRACTOR TO BE RESPONSIBLE FOR ADHERING
TO ALL APPLICABLE CODES AND SAFETY REQUIREMENTS.
CONTRACTOR AND ELECTRICAL SUBCONTRACTOR TO REVIEW THE
PLANS AND WALK THROUGH THE JOB TO VERIFY THAT THE DESIGN
INTENT IS MAINTAINED. GENERAL CONTRACTOR TO NOTIFY DESIGNER
IF ANY ITEMS ARE DIFFERENT FROM THE ELECTRICAL PLANS BEFORE
THE INSTALLATION OF FIXTURES, SWITCHES, ETC.
GAS OR ELECTRICAL SERVICE TO BE PROVIDED AS REQUIRED FOR ALL
APPLIANCES AND EQUIPMENT SUCH AS REFRIGERATOR, DISHWASHER,
DISPOSAL, FREEZER, COOKTOP, WASHER, DRYER, OVENS, HVAC
EQUIPMENT, ALARM PANEL, ETC. PROVIDE OUTLET ABOVE RANGE FOR
MICROWAVE OR HOOD VENT IF FINAL KITCHEN LAYOUT REQUIRES.
ALL OUTLETS THAT ARE NEAR ANY WATER CONDITIONS TO BE G.F.C.I.
TYPE PER CODE.
SWITCHES AND OUTLETS TO BE COORDINATED WITH THE OWNER AND
COLOR MATCHED WITH THE INTERIOR TRIM.
CONTRACTOR TO VERY ALL LOCATIONS OF PHONE OUTLETS,
COMPUTER OUTLETS, AND ELECTRONIC DEVIDE OUTLETS. ALL
COMPUTER OUTLETS TO BE ON A DEDICATEDD CIRCUIT.
CONTRACTOR TO VERIFY THE LOCATIONS OF THE CABLE TV OUTLETS.
VERIFY TRIM SIZE FOR ALL DOORS AND WINDOWS BEFORE SWITCHES
ARE LOCATED. LOCATED SWITCHES CLOSE TO TRIM AND ALIGN WITH
EACH OTHER IF THERE ARE MULTIPLE SWITCHES.
CONTRACTOR TO VERIFY WITH DESIGNER ALL LANDSCAPE AND
EXTERIOR LIGHTING CIRCUITS AND SWITCHES.
PROVIDE HARDWIRED SMOKE DETECTORS, WITH BATTERY BACKUP,
ON ALL FLOORS. VERIFY WITH LOCAL CODE REQUIREMENTS.
G.C. TO VERIFY ALL LIGHTING & SWITCH LOCATIONS WITH OWNER.
1 LEVEL 1 RCP
3/16" = 1'-0"
REFLECTED CEILING LEGEND
2 LEVEL 2 RCP
3/16" = 1'-0"5607 COUNTRY CLUB BLVD4/6/24
20'-6"7'20'-6"4'-4"
55'5'-11 1/2"6'5'-8"36'-6"54'-1 1/2"101'-6"106'-2"55'
27'27'-6"15'-8"31'-8 1/2"3'-4"7'-7"2'2'1'-4"2'-4"2'-4"3'-4"101'-6"106'-2"13'-4"9'12'-6"12'-8"6'-4"32'15'-8"2'-8"
2'-8"
4'-4"11'6'-7 1/2"3'
3'
27'-6"
1'-6"3'-4"
3'-8"3'-4"47'-4 1/2"17'-7 1/2"54'-6"6"
9'-2 1/2"9'-2"119'-6 13/16"
HOUSE SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
CONTROL JOINT
GARAGE SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
HOUSE SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
PORCH SLAB
PORCH SLAB
4" CONCRETE SLAB WITH 6"X6", #10/#10
W.W.M. OVER 15 MIL STEGO WRAP ON MIN.
4" COMPACTED FILL
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @ 24" O.C. HORIZ.
AT LOAD BEARING INT. WALLS
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @ 24" O.C. HORIZ.
AT LOAD BEARING INT. WALLS
THICKENED SLAB FOOTING
W/ (2) #4 REBAR CONT. &
#4 REBAR @ 24" O.C. HORIZ.
AT LOAD BEARING INT. WALLS
SAFE ROOM
SLAB
CONTROL JOINT
CONTROL JOINT
CONTROL JOINT
CONTROL JOINT
8 : 1210 : 12
8 : 1210 : 12 8 : 128 : 1210 : 12
8 : 1210 : 12
8 : 1210 : 12 8 : 1210 : 12
8 : 128 : 1210 : 12
8 : 1210 : 1210 : 12
8 : 1210 : 12 4 : 120 : 12BARREL ROOF BARREL ROOF
RIDGE CAP
ARCH. ASPHALT SHINGLES
CHIMNEY CAP
STANDING SEAM METAL ROOF
RIDGE CAP
CHIMNEY CAP
ARCH. ASPHALT SHINGLES
CHIMNEY CAP
STANDING SEAM METAL ROOF
RIDGE CAP
ARCH. ASPHALT SHINGLES
EPDM ROOFING MEMBRANE PROJECT TITLECONTENTSROOF PLAN/FOUNDATION PLANDATESHEETA 4.0GENERAL ROOF NOTES:
1.
2.
3.
4.
5.
6.
TYPICAL 10:12 PITCH FRONT TO BACK, 12:12 PITCH SIDE TO
SIDE. ASPHALT SHINGLES UNLESS OTHERWISE STATED.
TYPICAL 3:12 PITCH AT STANDING SEAM METAL ROOF.
PROVIDE SCREENED VENTS @ EACH 3RD JOIST SPACE @
ALL ATTIC EAVES.
USE 1/2" EXTERIOR PLYWOOD AT ALL EXPOSED EAVES.
USE ARCHITECTURAL ASPHALT SHINGLE ROOFING AND
UNDERLAY PER MANUFACTURERS SPECIFICATIONS
UNLESS NOTED OTHERWISE.
LOCATE ALL ROOF PENETRATING PLUMBING PIPES ON
THE "BACK" OF THE HOUSE.
NEW GUTTERS & DOWNSPOUTS THROUGHOUT HOUSE -
VERIFY W/ OWNER.
PROVIDE ATTIC VENTILATION AS APPROVED BY OWNER &
REQUIRED BY CODE BASE ON ATTIC AREA.
1 ROOF PLAN
3/16" = 1'-0"
GENERAL INSULATION NOTES:
1.
2.
3.
FLOORS OVER UNHEATED SPACE TO HAVE R-30 MIN INSULATION
BETWEEN JOISTS.
HVAC DUCTS LOCATED IN UNHEATED SPACES TO BE INSULATED
WITH R-8. CONTRACTOR TO VERIFY WITH LOCAL CODES.
ALL EXPOSED INSULATION TO HAVE A FLAME SPREAD RATING OF
LESS THAN 25 AND A SMOKE DENSITY RATING OF LESS THAN 450.
2 FOUNDATION PLAN W/ OVERLAY
3/16" = 1'-0"
GENERAL FOUNDATION NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
CONTRACTOR TO INSPECT THE JOB SITE AND EXCAVATED
CONDITIONS PRIOR TO STARTING CONSTRUCTION.
CONTRACTOR TO NOTIFY DESIGNER AND ENGINEER OF ANY
CONDITIONS REGARDING SOILS, GROUND WATER, OR ANY
OTHER ISSUE WHICH MAY REQUIRE ADDITIONAL OR SPECIAL
ENGINEERING DESIGN BY A LICENSED STRUCTURAL
ENGINEER.
CONTRACTOR TO REVIEW PLANS, ELEVATIONS, AND DETAILS
FOR DIMENSION OF FINISH FLOOR ABOVE TYPICAL GRADE.
CONTRACTOR TO NOTIFY DESIGNER IF THERE ARE ANY SITE
CONDITIONS THAT REQUIRE MODIFICATIONS TO DIMENSIONS
INDICATED ON PLANS, SECTIONS, OR EXTERIOR ELEVATIONS.
CONTRACTOR TO VERIFY FOOTING DEPTHS WITH LOCAL
FROST REQUIREMENTS OR EXISTING SOIL CONDITIONS;
WHICH EVER IS MORE RESTRICTIVE.
ALL FOOTINGS TO REST ON UNDISTURBED SOIL.
CONTRACTOR TO COORDINATE WITH LICENSED, BONDED
INSTALLER TO PROVIDE TERMITE TREATMENT WHICH
COMPLIES WITH ALL LOCAL BUILDING CODES.
PROVIDE 1/2" EXPANSION JOINT MATERIAL BETWEEN ALL
CONCRETE SLABS ON ABUTTING CONCRETE OR MASONRY
WALL OCCURRING IN EXTERIOR OR UNHEATED INTERIOR
AREAS.
UNLESS OTHERWISE NOTED, ALL SLABS ON GRADE TO BE
3500 PSI CONCRETE ON 4" GRAVEL FILL MINIMUM, WITH
6x6-10/10 WIRE MESH REINFORCING. INTERIOR SLABS TO BE
PLACED ON 15 MIL. STABILIZED POLYETHYLENE VAPOR
BARRIER. THICKEN SLAB TO 12" AT LOAD BEARING WALLS.
PROVIDE 1/4" DEEP SCORE CONTROL JOINTS AT MID POINTS
OF ALL GARAGE SLABS, BOTH DIRECTIONS NOT MORE THAN
20' APART.5607 COUNTRY CLUB BLVD4/6/24