HomeMy WebLinkAboutZ-5934-C - Site Plan APPROVEDSSW W
UGEXXXXXXXXX
UFOUFOUFOUFOUFOUFOUFOUFOUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGTVUGE
UGE
U
G
E UGEUGEUFOSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSSGASGASGASGASGASGASGASGASGASGASGASUGTVUGTVWW UGTVSSSSSSSSSSSSSSSSSS
SSSS SSSS
SSDD9'
9'
9'9'R5R8R4R2.5R4R4R4R4R4R4R4R518.5'8'
W
W
W
WFH
24'R20R
2
0
131.71'205.62'19.91'23.24'
36.17'
8.23'91.29'64.38'R32.01R
3
3
.
1
2 R4.11R14.4424'7.49'29.28'8.77'57.19'100.39'RELOCATED FIREHYDRANTRELOCATED FIREHYDRANTEX. FIRE HYDRANTEX. FIRE HYDRANT14315103388SITE PLAN -BOARD OFADJUSTMENTS0102040201 inch = 20ft.( IN FEET )PLAN SCALEC1.00801 South Spring StreetLittle Rock, AR 72201501.378.0878 office509 W. Spring St. | Suite 150Fayetteville, AR 72701479.444.0473 officepolkstanleywilcox.com2023.12.18Issue Date:Contents:LITTLE ROCK, ARKANSASCALS MAINLIBRARYRENOVATIONREVISIONSNUMBER DATE DESCRIPTIONMEPFPBernhard1 Allied Drive, Bldg 2, Suite 2600Little Rock, AR 72202PH: 501-666-6776STRUCTURAL1 Allied Drive, Bldg 2, Suite 2600Little Rock, AR 72202PH: 501-666-677676CIVILMcClelland Consulting Engineers, Inc.7302 Kanis Rd.Little Rock, AR 72204PH: 501-371-0272336OPSW Job Number:CLR PLANNING SUBMITTALLANDSCAPEECOLOGICAL DESIGN GROUP, INC.120 S. Izard StreetLittle Rock, AR 72201PH: 501-378-0200ASSOC. ARCHITECTSWER Architects901 W. 3rd StreetLittle Rock, AR 72201PH: 501-374-5300W:\2023\23-5797 Little Rock CALS Expansion - Main Library\Design Drawings\Civil\23-5797 DESIGN.dwg 12/18/23 at 7:03pm
RIVER MARKET DESIGN OVERLAY DISTRICTVARIANCES REQUESTED:SEC. 36-353 (C)(1) B. THE PROPOSED SIGN EXCEEDS THE MAXIMUM ALLOWABLE SIZE.SEC. 36-353 (C)(2). THE PROPOSED SIGN EXCEEDS THE MAXIMUM ALLOWABLE HEIGHT. SIGNS SHALL NOR EXCEED ONE-HALF OFA SQUARE FOOT OF SIGN AREA FOR EACH LINEAR FOOT OF STREET BUILDING FRONTAGE, NOR EXCEEDING TWENTY-FIVE SQUAREFEET PER SIGN.SEC. 36-356 (A)(1). THE PROPOSAL REMOVES HISTORIC MATERIALS AND DISTINCTIVE ARCHITECTURAL FEATURES.SEC. 36-356 (C)(1). THE PROPOSAL DOES NOT RETAIN THE ORIGINAL DIMENSIONS OF HISTORICAL UPPER FAÇADE WINDOWS.SEC. 36-356 (C)(4). THE PROPOSED PRIMARY ENTRANCE IS PERPENDICULAR TO SOUTH ROCK STREET.SEC. 36-356 (D)(1). THE PROPOSED BUILDING HEIGHT IS 86.65 FEET.SEC 36-356 (D)(3). THE HISTORICAL CONTEXT OF THE BUILDING IS FURTHER ALTERED RATHER THAN RESTORED TO ITS ORIGINALDESIGN.SEC. 35-356 (F)(2). AND SEC. 36-357 (B)(3). THE PROPOSED FRONT ELEVATION CANOPY EXCEEDS THE MAXIMUM PROJECTBUILDING FAÇADE. THE PROPOSED CANOPY EXTENDS APPROXIMATELY 19 FEET FROM THE BUILDING FAÇADE.SEC. 36-358 (A)(6). THE PROPOSED OPEN SPACE DOES NOT UTILIZE THE SPECIFIED PLANT MATERIALSPROPOSED LEGENDCURB AND GUTTEREASEMENTSETBACKTEMPORARY CONSTRUCTION EASEMENTFENCEPAINTED / THERMOPLASTIC STRIPINGASPHALT PAVEMENTCONCRETE PAVEMENTCONCRETE SIDEWALKCATCH BASINFLARED END SECTIONSANITARY SEWER MANHOLEPARKING STALL COUNTBUILDING CONTROL POINTFIRE DEPARTMENT CONNECTIONFIRE HYDRANTPOST INDICATOR VALVEWATER METERPOWER POLE/POWER POLE & GUYLIGHT POLEELECTRICAL TRANSFORMERELECTRICAL PEDESTALTELEPHONE PEDESTALTRAFFIC SIGNAL PEDESTALTCEX XESWMWPIVFDCFHDEPTPTSPDXXPARKING TABLESTANDARD ADATOTALEXISTING76480PROPOSED51455Approved with conditions by BOA 02/15/2024