HomeMy WebLinkAboutS-0943-A Staff AnalysisSeptember 19, 2002
ITEM NO.: 4 FILE NO.: S-943-A
NAME: Boen 430 Subdivision Preliminary Plat
LOCATION: Northeast corner of 1-430 and Colonel Glenn Road
DEVELOPER:
ENGINEER:
Leonard Boen McGetrick and McGetrick Engineers
10600 Colonel Glenn Road 319 President Clinton Avenuae
Little Rock, AR 72204 Little Rock, AR 72201
AREA: 4.23 acres NUMBER OF LOTS: 3 FT. NEW STREET: 0
CURRENT ZONING: C-3, General Commercial
PLANNING DISTRICT: 11 — 1-430
CENSUS TRACT: 24.05
VARIANCESMAIVERS REQUESTED: None requested.
A preliminary plat was filed for the site and approved May 19, 1992 for a four lot
subdivision. As a part of the proposal a variance request was approved by the
Board of Directors at their June 16, 1992 meeting to allow a variance of the
minimum pavement width and right-of-way width requirements (27-foot pavement
width and 50-foot right-of-way). The lots were not Final Platted prior to
expiration of the preliminary plat.
The applicant now proposes a preliminary plat for a three lot subdivision with a
60-foot access easement with 36-feet of pavement. There are no additional curb
cuts proposed for Lots 1 and 3. These lots will take access from the access
easement.
September 19, 2002
SUBDIVISION
ITEM NO.: 4 (Cont.
B. EXISTING CONDITIONS:
FILE NO.: S-943-A
The land area has been modified with the removal of trees and natural growth.
There is a grade on the site, which varies from the Colonel Glenn right-of-way to
the north at which point there is a significant hill mass with a large water tank. To
the east, is the Clear Channel Metroplex facility and to the west is 1-430. South
of the site is vacant undeveloped C-3 and 0-3 property in which the developer is
currently installing basic infrastructure.
A portion of the street improvements have been made adjacent to the Clear
Channel Development but are not in place adjacent to the site. The road is a two
lane roadway with open ditches for drainage.
C. NEIGHBORHOOD COMMENTS:
As of this writing, Staff has not received any comment from area residents. The
Stagecoach Dodd and the John Barrow Neighborhood Associations were notified
of the Public Hearing along with all abutting property owners.
D. ENGINEERING COMMENTS:
Public Works:
1. Colonel Glenn Road is classified on the Master Street Plan as a principal
arterial. A minimum dedication of right-of-way to 55 feet from centerline will
be required.
2. Provide design of street conforming to "MSP" (Master Street Plan).
Construct one-half street improvements to the street including 5-foot
sidewalks with planned development.
3. Plans of all work in right-of-way shall be submitted for approval prior to start
of work.
4. Obtain permits for improvements within State Highway right-of-way from
AHTD, District VI.
5. Stormwater detention ordinance applies to this property.
6. Easements for proposed stormwater detention facilities are required.
7. A Grading Permit will be required per Sec. 29-186 (c) & (d).
8. Prepare a letter of pending development addressing street lights as required
by Section 31-403 of the Little Rock code. Contact Traffic Engineering at
501-379-1813 (Steve Philpott) for more information regarding street light
requirements.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required, with easements, if service is
required for the project. Contact Little Rock Wastewater Utility for additional
details at 376-2903.
4
September 19, 2002
SUBDIVISION
ITEM NO.: 4 (Cont.) FILE NO.: 5-943-A
AP & L: No comment received.
ARKLA: No comment received.
Southwestern Bell: No comment received.
Water: A water main extension will be required in order to provide water service
to this property. An acreage charge of $150.00 per acre currently applies in
addition to normal charges in this area. Due to the operation and
maintenance of the tank and pump station north of this site, the natural
drainage across this site should not be obstructed.
Fire Department: Approved as submitted.
County Planning: No comment received.
CATA: Site is not located on a dedicated bus route and has no effect on bus
radius, turnout and route.
F. ISSUES/TECHNICAL/DESIGN:
Planning Division: No comment.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT:
(August 29, 2002)
Mr. Pat McGetrick and Ms. Laura McGetrick of McGetrick and McGetrick
Engineers were present representing the application. Staff introduced the item to
the Commission stating a preliminary plat had previously been filed for the area
but was never final platted. Staff stated the time for final platting had expired and
the applicant was now requesting a similar preliminary plat. Staff stated the
previously approved preliminary plat contained four (4) lots and a single access
easement from Colonel Glenn Road where the current proposal included only
three (3) lots.
Staff stated there were items, which needed to be shown on the proposed
preliminary plat (building setback lines, water and wastewater supply and
disposal, zoning of abutting properties). Staff also stated the Water Department
should be contacted regarding their comments.
3
September 19, 2002
SUBDIVISION
ITEM NO.: 4 (Cont.
FILE NO.: S-943-A
Public Works comments were addressed in detail noting the road widening of
Colonel Glenn Road adjacent to the applicant's property. There being no
additional issues to discuss, the Committee then forwarded the item to the full
Commission for final action.
H. ANALYSIS:
The applicant submitted a revised preliminary plat addressing most of the issues
raised by Staff and the Subdivision Committee. The proposal includes the
proposed source of water (Central Arkansas Water), the means of wastewater
disposal (Little Rock Wastewater Utility), the minimum lot size and the average
lot size and the front yard building setback shown on the plat. The proposal
includes three lots with an average size of 1.40 acres. The lots are currently
zoned C-3, General Commercial and the applicant has indicated a 35-foot platted
building line adjacent to Colonel Glenn Road.
The lots will be accessed by a private 60-foot right-of-way and 36-foot of
pavement private roadway. Lots 1 and 3 are adjacent to Colonel Glenn and will
have no access to Colonel Glenn Road. The proposed plat should show a 10-
foot platted no access easement along Colonel Glenn for these two lots.
Lot 2 is located at the rear of the site and has some terrain problems on the north
and west sides of the lot. Central Arkansas Water also owns property located to
the north of the site where a water tower is located. It is important the applicant
note the comment from Central Arkansas Water with regard to blocking of the
natural drainage way across the site.
Otherwise, to Staff's knowledge there are no outstanding issues associated with
the proposed preliminary plat. The proposed preliminary plat complies with the
minimum requirements of the Subdivision Ordinance and Staff is supportive of
the proposed request.
STAFF RECOMMENDATION:
Staff recommends approval of the proposed preliminary plat for Boen Subdivision
subject to compliance with the conditions outlined in Paragraphs D, E, F and H of
this report.
12
September 19, 2002
ITEM NO.: 4 FILE NO.: 5-943-A
NAME: Boen 430 Subdivision Preliminary Plat
LOCATION: Northeast corner of 1-430 and Colonel Glenn Road
DEVELOPER:
ENGINEER:
Leonard Boen McGetrick and McGetrick Engineers
10600 Colonel Glenn Road 319 President Clinton Avenuae
Little Rock, AR 72204 Little Rock, AR 72201
AREA: 4.23 acres NUMBER OF LOTS: 3 FT. NEW STREET: 0
CURRENT ZONING: C-3, General Commercial
PLANNING DISTRICT: 11 —1-430
ENSUS TRACT: 24.05
VARIANCESMAIVERS REQUESTED: None requested.
A. PROPOSAL:
A preliminary plat was filed for the site and approved May 19, 1992 for a four lot
subdivision. As a part of the proposal a variance request was approved by the
Board of Directors at their June 16, 1992 meeting to allow a variance of the
minimum pavement width and right-of-way width requirements (27-foot pavement
width and 50-foot right-of-way). The lots were not Final Platted prior to
expiration of the preliminary plat.
The applicant now proposes a preliminary plat for a three lot subdivision with a
60-foot access easement with 36-feet of pavement. There are no additional curb
cuts proposed for Lots 1 and 3. These lots will take access from the access
easement.
September 19, 2002
SUBDIVISION
ITEM NO.: 4(Cont.)PILE NO.: S-943-A
B. EXISTING CONDITIONS:
The land area has been modified with the removal of trees and natural growth.
There is a grade on the site, which varies from the Colonel Glenn right-of-way to
the north at which point there is a significant hill mass with a large water tank. To
the east, is the Clear Channel Metroplex facility and to the west is 1-430. South
of the site is vacant undeveloped C-3 and 0-3 property in which the developer is
currently installing basic infrastructure.
A portion of the street improvements have been made adjacent to the Clear
Channel Development but are not in place adjacent to the site. The road is a two
lane roadway with open ditches for drainage.
C. NEIGHBORHOOD COMMENTS:
As of this writing, Staff has not received any comment from area residents. The
Stagecoach Dodd and the John Barrow Neighborhood Associations were notified
of the Public Hearing along with all abutting property owners.
D. ENGINEERING COMMENTS:
Public Works:
1. Colonel Glenn Road is classified on the Master Street Plan as a principal
arterial. A minimum dedication of right-of-way to 55 feet from centerline will
be required.
2. Provide design of street conforming to "MSP" (Master Street Plan).
Construct one-half street improvements to the street including 5-foot
sidewalks with planned development.
3. Plans of all work in right-of-way shall be submitted for approval prior to start
of work.
4. Obtain permits for improvements within State Highway right-of-way from
AHTD, District VI.
5. Stormwater detention ordinance applies to this property.
6. Easements for proposed stormwater detention facilities are required.
7. A Grading Permit will be required per Sec. 29-186 (c) & (d).
8. Prepare a letter of pending development addressing street lights as required
by Section 31-403 of the Little Rock code. Contact Traffic Engineering at
501-379-1813 (Steve Philpott) for more information regarding street light
requirements.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required, with easements, if service is
required for the project. Contact Little Rock Wastewater Utility for additional
details at 376-2903.
2
September 19, 2002
SUBDIVISION
ITEM NO.: 4 Cont. FILE NO.: S-943-A
AP & L: No comment received.
ARKLA: No comment received.
Southwestern Bell: No comment received.
Water: A water main extension will be required in order to provide water service
to this property. An acreage charge of $150.00 per acre currently applies in
addition to normal charges in this area. Due to the operation and
maintenance of the tank and pump station north of this site, the natural
drainage across this site should not be obstructed.
Fire Department: Approved as submitted.
County Planning: No comment received.
CATA: Site is not located on a dedicated bus route and has no effect on bus
radius, turnout and route.
F. ISSUESITECHNICAUDESIGN:
Planning Division: No comment.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT:
(August 29, 2002)
Mr. Pat McGetrick and Ms. Laura McGetrick of McGetrick and McGetrick
Engineers were present representing the application. Staff introduced the item to
the Commission stating a preliminary plat had previously been filed for the area
but was never final platted. Staff stated the time for final platting had expired and
the applicant was now requesting a similar preliminary plat. Staff stated the
previously approved preliminary plat contained four (4) lots and a single access
easement from Colonel Glenn Road where the current proposal included only
three (3) lots.
Staff stated there were items, which needed to
preliminary plat (building setback lines, water
disposal, zoning of abutting properties). Staff also
should be contacted regarding their comments.
be shown on the proposed
and wastewater supply and
stated the Water Department
3
September 19, 2002
SUBDIVISION
ITEM NO.: 4 (Cont.) FILE NO.: S-943-A
Public Works comments were addressed in detail noting the road widening of
Colonel Glenn Road adjacent to the applicant's property. There being no
additional issues to discuss, the Committee then forwarded the item to the full
Commission for final action.
H. ANALYSIS:
The applicant submitted a revised preliminary plat addressing most of the issues
raised by Staff and the Subdivision Committee. The proposal includes the
proposed source of water (Central Arkansas Water), the means of wastewater
disposal (Little Rock Wastewater Utility), the minimum lot size and the average
lot size and the front yard building setback shown on the plat. The proposal
includes three lots with an average size of 1.40 acres. The lots are currently
zoned C-3, General Commercial and the applicant has indicated a 35-foot platted
building line adjacent to Colonel Glenn Road.
The lots will be accessed by a private 60-foot right-of-way and 36-foot of
pavement private roadway. Lots 1 and 3 are adjacent to Colonel Glenn and will
have no access to Colonel Glenn Road. The proposed plat should show a 10-
foot platted no access easement along Colonel Glenn for these two lots.
Lot 2 is located at the rear of the site and has some terrain problems on the north
and west sides of the lot. Central Arkansas Water also owns property located to
the north of the site where a water tower is located. It is important the applicant
note the comment from Central Arkansas Water with regard to blocking of the
natural drainage way across the site.
Otherwise, to Staff's knowledge there are no outstanding issues associated with
the proposed preliminary plat. The proposed preliminary plat complies with the
minimum requirements of the Subdivision Ordinance and Staff is supportive of
the proposed request.
I. STAFF RECOMMENDATION:
Staff recommends approval of the proposed preliminary plat for Boen Subdivision
subject to compliance with the conditions outlined in Paragraphs D, E, F and H of
this report.
PLANNING COMMISSION ACTION:
(SEPTEMBER 19, 2002)
Mr. Pat McGetrick of McGetrick and McGetrick Engineers was present representing the
application. Staff presented the item with a positive recommendation subject to
compliance with the conditions outlined in paragraphs D, E, F and H of the Staff report.
C!
September 19, 2002
SUBDIVISION
ITEM NO.: 4 (Cont.) _ _ FILE NO.: S-943-A
There was no further discussion. The item was placed on the Consent Agenda for
Approval and approved, as recommended by Staff, by a vote of 11 ayes, 0 noes and
0 absent.
5