HomeMy WebLinkAboutZ-10012 Site Plan 051624EXISTING FIRE HYDRANT
DIMENSIONS APPROXIMATED FROM PAGIS
J
N
O
rn
co
co
d
a-
_
=
o
z
zo
0
CNI
aoo
0
J
X
00
I
0
<
I
0
U)
\
I
C
dIr
Zco
—co
O
'p0.
LANDSCAPE
AREA
N
v,
Cn
m
D
LANDSCAPE
PRIVACY FENCE
S87046'15"E 294.46'
FFE 322.00 I FFE 324.00 FFE 326.00 I 1,936
FFE 328.00
NIT
FFE 322.00
FFE 324.00
FFE 326.00
PRIVATE DRIVE
27-5 32'
1,936 SF/UNIT
FFE 328.00
N87°48'37"W 295.73'
EA
FFE 330.00 ' FFE 332.00
FFE 330.00 1 FFE 332.00
FFE 334.00
FFE 334.00
LANDSCAPE U
BUFFER AREA Z
w
IL
N U
VI
Lo
T
330
a
� C7
0
LANDSCAPE
BUFFER AREA
I
I \
—1.014 ± ACRES
a
0
0
J
(D
f—
SHEPARD DRIVE
PROJECT LOCATION
N.T.S.
LEGEND
BOUNDARY LINE
SETBACK LINE
^ FENCELINE
— vv vv— EXISTING WATER
- SS EXISTING SANITARY SEWER
-- EXISTING FIRE HYDRANT
SITE INFORMATION
1. 1.014 ACRES
2. GROSS S.F. OF BUILDINGS: 26,194 S.F.
3. PARKING SPACES: 4 DRIVE AISLE 24'
4. PROPOSED USE: SINGLE FAMILY TOWNHOMES
SITE
AREAS
TOTAL SITE AREA
EXISTING BUILDING AREA
PROPOSED BUILDING AREA
DRIVE/HARDSCAPE AREA
LANDSCAPE AREA
44,180 SQ. FT.
0 SQ. FT.
26,194 SQ. FT.
7,752 SQ. FT.
10,234 SQ. FT.
100.0%
0%
59.3%
17.5%
23.2%
CURRENT ZONING: R2
PROPOSED ZONING: PD-R
20 10 0 20 40
SCALE
OWNERSHIP OF DOCUMENTS
THIS DOCUMENT, AND THE IDEAS AND DESIGNS
INCORPORATED HEREIN, AS AN INSTRUMENT OF
PROFESSIONAL SERVICES, IS THE PROPERTY OF
THE ENGINEER AND IS NOT TO BE USED, IN
WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE
WRITTEN AUTHORIZATION.
SAFETY NOTICE TO CONTRACTOR
IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION
PRACTICES, THE CONTRACTOR WILL BE SOLELY AND
COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB
SITE, INCLUDING SAFETY OF ALL PERSONS AND PROPERTY
DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT
WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO
NORMAL WORKING HOURS.
THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION
REVIEW OF THE CONTRACTORS PERFORMANCE IS NOT
INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE
CONTRACTOR'S SAFETY MEASURES, IN, OR NEAR THE
CONSTRUCTION SITE.
ENGINEER'S NOTICE TO CONTRACTOR
THE EXISTENCE AND LOCATION OF ANY UNDERGROUND
UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS
WERE OBTAINED BY A SEARCH OF THE AVAILABLE RECORDS.
TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING
UTIUTIES EXCEPT AS SHOWN ON THESE DRAWINGS AND WE
ASSUME NO RESPONSIBILITY AS TO THE ACCURACY OF
THEIR DEPICTED LOCATION ON THESE DRAWINGS. THE
CONTRACTOR IS REQUIRED TO TAKE DUE PRECAUTIONARY
MEASURES TO PROTECT THE UTILITY LINES SHOWN, AND
ALL OTHER LINES NOT OF RECORD OR NOT SHOWN ON THESE
DRAWINGS BY VERIFICATION OF THEIR LOCATION IN THE
FIELD PRIOR TO THE INITIATION OF THE ACTUAL PORTION
OF THEIR WORK.
SCALE 111=201
DRAWN BY � ELM
CHECKED BY � M E R
APPROVED BY
DATE
05/131/2024
CORPORATE SEAL
OFXAUTy0'A
4� RICKM
1= MORICONI v
W ENGINEERING 0
U INC.
#743
W
2
0
z
0�
Q
ou
� Y
00
J ry
LJ
� W
0 -�
Ld }
� Q _
a J
PROJECT NO.
P24-024
SHEET NO.
PD=R