Loading...
HomeMy WebLinkAboutElevations 052924PROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:45:09 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtCSCOVER SHEET20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTSHOUSE PLANSPROJECT TEAM DESIGN:GRC DESIGNS, LLCM. OMER FAROOQSCOPE OF WORK NEW CONSTRUCTIONSHEET INDEX CSCOVER SHEETA1.1FLOOR PLANSA1.2FOUNDATION PLANA2.1ELEVATION DRAWINGSA3.1ROOF PLANE1.1ELECTRICAL PLANSP1.1PLUMBING PLANSLOT INFO PROPERTY INFO: No. Description Date REF.DWUPWDREF.DWUPWDDNDN1. ALL EXTERIOR WALLS ARE 2X4 WOOD STUD @16" O.C.2. ALL INTERIOR WALLS ARE 2X4 WOOD STUD @16" O.C.3. ALL DIMENSIONS ARE TO FACE OF WALL U.N.O.4. ALL INTERIOR FINISHES INCLUDING BUT NOT LIMITED TO FLOORING, PAINT, WALLCOVERING, LIGHT FIXTURES, TRIM, LAMINATE, SOLID SURFACES AND MILLWORK TO BE SELECTED BY OWNER AND INSTALLED BY CONTRACTOR PER MANUF. GUIDELINES AND IN ACCORDANCE WITH ALL LOCAL CODES AND ORDINANCES.5. GENERAL CONTRACTOR SHALL VISIT SITE AND BECOME FAMILIAR WITH SITE CONDITIONS.6. NOTIFY DESIGNER IMMEDIATELY IF DIFFERENT CONDITIONS EXIST FROM WHAT IS DESCRIBED.7. ALL MECHANICAL, ELECTRICAL AND PLUMBING ITEMS TO BE PROVIDED ON A DESIGN/ BUILD BASIS, IN ACCORDANCE WITH ALL LOCAL CODES AND ORDINANCES. ASIDE FROM ALL ELECTRICAL AND PLUMBING ITEMS REPRESENTED ON PLANS, PROVIDE ADDITIONAL DEVICES AS REQUIRED BY LOCAL CODE.FLOOR PLAN NOTESFLOOR PLANITEMWALL ASSEMBLIESDESCRIPTIONINTERIOR WALL 2X4 WOOD STUD @16" O.CEXTERIOR WALL 2X4 WOOD STUD @16" O.C1/ A2.14/ A2.12/ A2.13/ A2.120' - 0"26' - 0"10' - 0"8' - 10 1/2"5' - 0"5' - 7 1/2"13' - 10 1/2"BEDROOM 1LAUNDRYKITCHENLIVING24" x 80"2' 6" x 7' 0"36" x 96"2' 6" x 7' 0"36"x60"36" X 60"36" X 60"36" X 48"11' - 0"CLOSET2' 2" x 7' 0"5' 0" x 6' 8" BF14' - 6" 1' - 4 1/2"20' - 0"26' - 0"10' - 0"8' - 10 1/2"5' - 0"5' - 7 1/2"13' - 10 1/2"BEDROOM 1 LAUNDRYKITCHENLIVING24" x 80"2' 6" x 7' 0"36" x 96"2' 6" x 7' 0"36"x60"36" X 60"36" X 60"36" X 48"11' - 0"CLOSET2' 2" x 7' 0"5' 0" x 6' 8" BF14' - 6"1' - 4 1/2"40' - 0"40' - 0"1/ A2.14/ A2.12/ A2.13/ A2.111' - 0"3' - 2"12' - 4"2' - 6"11' - 0"12' - 4"6' - 6 1/2"BATHBEDROOM 2BEDROOM 3CLOSETCLOSETHALLWAYLINLIN20' - 0"26' - 0"3' - 9"8' - 6"2' 6" x 7' 0"2' 6" x 7' 0"2' 6" x 7' 0"5' 6" x 6' 8" BF5' 6" x 6' 8" BF36" X 48"36" X 60"36"x60"3' - 2"3' - 0"20' - 0"11' - 0"3' - 2"12' - 4"2' - 6"11' - 0"12' - 4"6' - 6 1/2"BATHBEDROOM 2BEDROOM 3CLOSETCLOSETHALLWAYLINLIN20' - 0"26' - 0"3' - 9"8' - 6"2' 6" x 7' 0"2' 6" x 7' 0"2' 6" x 7' 0"5' 6" x 6' 8" BF5' 6" x 6' 8" BF36" X 48"36" X 60"36"x60"3' - 2"20' - 0"40' - 0"PROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:44:53 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtA1.1FLOOR PLANS20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTSNo. Description Date1/4" = 1'-0"1FIRST FLOOR PLAN1/4" = 1'-0"2SECOND FLOOR 6’’ CONC. SLAB OVER COMPACT GRADE REINFORCED WITH #4 REBAR @ 12’’CROSSHATCH1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1/ A2.14/ A2.12/ A2.13/ A2.124’’ X 24’’ X 24’’ CONC. FOOTING FOR WOOD POSTS6’’ CONC. SLAB OVER COMPACT GRADE REINFORCED WITH #4 REBAR @ 12’’CROSSHATCH1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"1' - 0"12’’ X 24’’ CONC. FOOTING REINFORCED WITH # 4 REBAR18’’ X 24’’ CONC. FOOTING REINFORCED WITH # 4 REBAR20' - 0" 20' - 0"40' - 0"1' - 0"24' - 0"1' - 0"26' - 0"1' - 0" 18' - 3" 1' - 6" 18' - 3" 1' - 0"3' - 8 1/2"8' - 8" 22' - 7 1/2" 8' - 8"2' - 0"2' - 0"PROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:44:53 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtA1.2FOUNDATIONPLAN20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTSFOUNDATION PLAN NOTES1. VERIFY ALL DIMENSIONS WITH THE ARCHITECTURAL DRAWINGS. 2. DETAILS ON THESE PLANS ARE INTENDED TO DEPICT THE GENERAL CONSTRUCTION METHODS FOR THIS STRUCTURE. CONNECTIONS, DETAILS AND CONDITIONS NOT SPECIFICALLY SHOWN THAT ARE SIMILAR TO THOSE THAT ARE SPECIFIED SHALL BE ASSUMED ONE AND THE SAME. IF QUESTIONS REGARDING THE APPLICATION OF DETAILS ARE ENCOUNTERED, NOTIFY THE ARCHITECT / ENGINEER FOR CLARIFICATION IN A TIMELY MANNER PRIOR TO BID OPENING.3. ALL FOOTINGS SHALL BEAR ON UNDISTURBED NATIVE SOILS OR ENGINEERED FILL PREPARED IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE PROJECT GEOTECHNICAL REPORT.4. SUBGRADE REQUIREMENTS, UNDERSLAB VAPOR BARRIER AND PERIMETER FOUNDATION DRAINAGE SHALL BE PROVIDED IN ACCORDANCE WITH THE RECOMMENDATIONS IN THE PROJECT GEOTECHNICAL REPORT.5. ANCHOR BOLTS AND PLATE WASHERS AT SHEAR WALLS SHALL BE PLACED IN ACCORDANCE WITH THE REQUIREMENTS.6. PLACE REINFORCING BARS AT CORNERS AND INTERSECTIONS FOR FOUNDATIONS. BARS AT CORNERS AND INTERSECTIONS SHALL BE EQUAL IN SIZE, NUMBER AND SPACING TO HORIZONTAL REINFORCING.1/4" = 1'-0"1FOUNDATIONNo. Description Date FIRST FLOOR1' -0"SLAB LEVEL0"RIDGE30' -5"TOP PLATE20' -0"SECOND FLOOR11' -0"FIRST FLOOR1' -0"SLAB LEVEL0"RIDGE30' -5"TOP PLATE20' -0"SECOND FLOOR11' -0"FIRST FLOOR1' -0"SLAB LEVEL0"RIDGE30' -5"TOP PLATE20' -0"SECOND FLOOR11' -0"FIRST FLOOR1' -0"SLAB LEVEL0"RIDGE30' -5"TOP PLATE20' -0"SECOND FLOOR11' -0"PROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:44:55 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtA2.1EXTERIORELEVATIONS20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTS1/4" = 1'-0"1FRONT ELEVATION1/4" = 1'-0"2LEFT ELEVATION1/4" = 1'-0"3REAR ELEVATION1/4" = 1'-0"4RIGHT ELEVATIONNo. Description Date 1. CONTRACTOR TO PROVIDE ADEQUATE VENTILATION PER R806, IRC 2018.2. 12" EAVE ON ALL SIDES.GENERAL NOTESROOF PLANROOF PLANLEGEND30 YEAR SHINGLE ROOFEXTERIOR WALL STUD BELOW ROOFSTANDING SEAM METAL ROOFTPO ROOF1/ A2.14/ A2.12/ A2.13/ A2.1996699PROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:44:56 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtA3.1ROOF PLAN20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTS1/4" = 1'-0"1ROOF PLANNo. Description Date 2GFCIWPCTRWPREF.DWUP2222222WDGFCIGFCIGFCIGFCIGFCIGFCIGFCI GFCIGFCI GFCIREF.DWUP222 2 222WDGFCI GFCIGFCIGFCIGFCIGFCIGFCIGFCIGFCI GFCIDNGFCI222DNGFCI222 1. OWNER TO PICK OUT LIGHT FIXTURES.2. LIGHT FIXTURE LAYOUT BY OWNER.3. LIGHT FIXTURE LAYOUT FOR SCHEMATIC DESIGN PURPOSES ONLY.4. ALL LIGHT FIXTURES TO BE CENTERED IN ROOM U.N.O.GENERAL NOTESREFLECTED CEILING PLANSingle Pole SwitchTwo Way SwitchFire AlarmPower OutletChandelier LightRecessed LightMotion Sense LightCarbon Mono-OxideSmoke DetectorWall Light ExternalGFCI Outletco/sFWeather Proof OutletCounter OutletFloor OutletCeiling Fan with LightTelephone Outlet220 V PlugCAT 5 Data OutletExhaust FanWeather Proof SwitchELECTRICAL LEGENDAll may not be usedMinislpit System24" Flouricent Light Electrical Box 200A PENDANT LIGHTco/sco/sco/sco/sco/sco/sco/sco/sPROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:45:10 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtE1.1ELECTRICALPLANS20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTSNo. Description Date1/4" = 1'-0"1ELECTRICAL PLAN1/4" = 1'-0"2SECOND FLOOR ELECTRIC REF.DWUPWDREF.DWUPWDPlumbing LegendHot Water: Cold Water:Sewage:Water Drain:SEWAGE LINE FROM SECOND FLOORWATER LINES TO SECOND FLOORWATER LINE FROM CITY/WELLSEWAGE LINE TO CITY/SEPTICSEWAGE LINE FROM SECOND FLOORWATER LINES TO SECOND FLOORWATER LINE FROM CITY/WELLSEWAGE LINE TO CITY/SEPTICSEWAGE LINE TO GROUND FLOORWATER LINES FROM GROUND FLOORSEWAGE LINE TO GROUND FLOORWATER LINES FROM GROUND FLOORPROJECT #ISSUE DATESHEET NAMEREVISIONSPROJECTCONSULTANTSHEET NUMBERPROJECT STATUS24x363/14/2024 1:45:11 PMD:\Projects\Recent\20240312 ryanaclin Duplex Plans\Project\ryanaclin.rvtP1.1PLUMBING PLANS20240307DUPLEX PLANS03.14.2024CONSTRUCTIONDOCUMENTSNo. Description Date1/4" = 1'-0"1PLUMBING PLANS1/4" = 1'-0"2SECOND FLOOR PLUMBING