Loading...
HomeMy WebLinkAboutAs Built Utility Plans 2 061824WWWWWWWWWW W W W SSSSSSSSD XXXXXXXWWWWWW W W W W W W W W W WWWWK I F MAIN A W M E D W MWM G H FH L EXISTING BUILDING 1 PROPOSED BUILDING #1 (NORTH) PROPOSED BUILDING #1 (SOUTH) 7 LF OF 6" D.I. PIPE 24 LF OF 6" D.I. PIPE 78 LF OF 6" D.I. PIPE17 LF OF 6" D.I. PIPE 6' LF OF 6" D.I. PIPE 60 LF OF 6" D.I. PIPE 19 LF OF 6" D.I. PIPE ANCHOR COLLAR #1 (BY MASS) ANCHOR COLLAR #2 (BY MASS) CUT & 6" PLUG #2 CUT & 8" PLUG #2 T.B. #12 T.B. #11 8"X6" TAPPING SLEEVE T.B. #10 T.B. #9 T.B. #8 T.B. #7 6"X6" TAPPING SLEEVE T.B. #1 T.B. #2 T.B. #3 T.B. #4 T.B. #5 T.B. #6 CLOW STANDARD FIRE HYDRANT ASSY. 4' S OF VALVE X#_______ 6"X6" ANCHOR TEE TO FIRE RISER WATER BELOW STORM WATER BELOW STORM 56 LF OF 6" D.I. PIPE 35 LF OF 6" D.I. PIPET.B. #14 W W 6 LF OF 6" D.I. PIPE WITH (2) 3/4" S.S. RODS EXISTING 134LF LINE ABANDONED &REMOVED 8" EXISTING PRIVATE WATER MAIN 6"X2" TEE W/ 5LF OF COPPER TO METER ASSEMBLY 6"X2" TEE W/ 4LF OF COPPER TO METER ASSEMBLY 9LF OF 6" D.I. PIPEBUILDING REFERANCE FOREAST/WEST LINE, POINTS J-PBUILDING REFERANCE FOR NORTH/SOUTH LINE, POINTS J-P BUILDING REFERANCEFOR EAST/WEST LINE,POINTS A-FBUILDING REFERANCE FOR NORTH/SOUTH LINE, POINTS A-F BUILDING REFERENCEFOR EAST/WEST LINE,POINTS I-GBUILDING REFERENCE FOR NORTH/SOUTH LINE, POINTS I-G 1 inch = 10ft. ( IN FEET ) PLAN SCALE 0 5 10 2010 Project IDCAD File Name 2021-0015 OUR HOUSE SITEWORK 302 E. Roosevelt Rd. Little Rock, AR 72206 No.Date Issue Notes Date SET-A 1 2 3 4 5 54321 A B C DD C B A CONSULTING ENGINEERS, INC. McCLELLAND D E S I G N E D T O S E R V E HTTP://WWW.MCE.US.COM 7302 KANIS ROAD LITTLE ROCK, ARKANSAS 72204 PH: (501) 371-0272 CA401 Overall Utility As-Built Plan 22-5716 DESIGN.DWG TOPOGRAPHIC AND BOUNDARY SURVEY PROVIDED BY OTHERS. CONTRACTOR SHALL REVIEW AND VERIFY ALL EXISTING ELEVATIONS AND FLOWLINE INFORMATION IN THE FIELD AND NOTIFY ENGINEER WITH POTENTIAL CONFLICTS FDC PROPOSED LEGEND GAS LINE GAS METER OVERHEAD ELECTRIC LINE UNDERGROUND ELECTRIC LINE WATER LINE FIRE DEPARTMENT CONNECTION FIRE HYDRANT WATER METER WATER VALVE REDUCER SANITARY SEWER LINE SANITARY SEWER MANHOLE CLEAN-OUT POWER POLE/POWER POLE & GUY CATCH BASIN GAS OHE UGE X''W W MW G FH D S D 400 POINT OF CONNECTION - WATER SERVICE 401 FIRE SPRINKLER BUILDING ENTRY (SEE ARCH. PLANS) - SHOULD THE FIRE DESIGN FROM THE FIRE CONSULTANT DEVIATE IN ANY WAY FROM THE CIVIL UTILITY SITE PLAN, THE CONTRACTOR SHALL CONTACT THE ENGINEER OF RECORD FOR COORDINATION PRIOR TO THE START OF CONSTRUCTION 402 DOMESTIC WATER SERVICE BUILDING ENTRY (SEE ARCH. / MEP PLANS) 404 FIRE DEPARTMENT CONNECTION (PER LOCAL CODES) 406 PROPOSED WATER METER (SEE SIZE AT SYMBOL) 423 SANITARY SEWER SERVICE BUILDING ENTRY (SEE ARCH. / MEP PLANS) 424 ADJUST EXISTING SANITARY SEWER MANHOLE RIM TO MATCH FINISH GRADES 428 CONNECT TO EXISTING SANITARY SEWER MANHOLE 432 ELECTRIC BUILDING ENTRY (SEE ARCH. / MEP PLANS) 441 POINT OF CONNECTION - NATURAL GAS SERVICE (PER GAS COMPANY REQUIREMENTS) 442 NATURAL GAS METER 443 NATURAL GAS BUILDING ENTRY (SEE ARCH. / MEP PLANS) UTILITY KEYNOTES OWNER/ DEVELOPER COMPANY NAME: OUR HOUSE, INC. STREET: 302 E ROOSEVELT RD. CITY, STATE ZIP: LITTLE ROCK, AR 72206 NAME / TITLE: MR MATT RUNGE, DIRECTOR OF OPERATIONS PHONE: 501-374-7383 EXT. 163 EMAIL: MATT.RUNGE@OURHOUSESHELTER.ORG CIVIL ENGINEERING CONSULTANT COMPANY NAME: MCCLELLAND CONSULTING ENGINEERS, INC. STREET: 7302 KANIS ROAD CITY, STATE ZIP: LITTLE ROCK, AR 72204 NAME / TITLE:DAN BERANEK, PE, PRESIDENT MCE-LITTLE ROCK PHONE:(501) 371.0272 EMAIL:DBERANEK@MCE.US.COM CONTACTS HYDRANT FLOW TEST INFORMATION DATE OF TEST 06/10/2022 MEASURED FLOW 1,500 GPM STATIC PRESSURE 84 PSI RESIDUAL PRESSURE 79 PSI 05/13/22 B C EXISTING WATER MAIN 6"X6" TAPPING SLEEVE 6"X18" D.I. SWIVEL ADAPTER 6"X18" D.I. SWIVEL ADAPTER 6"X6" ANCHOR TEE J N O P (2) SS RODS T.B. #14 T.B. #10 6" SS RISER 6"X18" SWIVEL ADAPTER MAIN A - Point Table Point # MA-A MA-B MA-C MA-D MA-E MA-F MA-G MA-H MA-I MA-J MA-K MA-L Description Location 6" GATE VALVE M&H OPEN R 21 TURNS 6" (MJ) 90° VERTICAL BEND 6" (MJ) 90° VERTICAL BEND 2" GATE VALVE M&H OPEN L 9 TURNS 6" (MJ) 90° BEND 6" GATE VALVE M&H OPEN/L 21 TURNS (2.5' N OF F.H.) 2" GATE VALVE M&H OPEN L 9 TURNS 2" GATE VALVE M&H OPEN L 9 TURNS 6" (MJ) 90° BEND 6" GATE VALVE M&H OPEN R 21 TURNS 6" (MJ) 45° BEND 6" GATE VALVE M&H OPEN R 21 TURNS 11.5' N OF THE N/S REFERENCE BUILDING LINE 52.8' E OF THE E/W REFERANCE BUILDING LINE MA-M MA-N MA-O MA-P 6" D.I. PIPE TO FIRE RISER CONNECTION POINT 6" (MJ) 45° VERTICAL BEND WITH MEGALUG RETAINER 6" (MJ) 45° VERTICAL BEND WITH MEGALUG RETAINER 6" STAINLESS STEEL FIRE RISER WITH PORTED CAP 11.3' N OF THE N/S REFERENCE BUILDING LINE 52.8' E OF THE E/W REFERANCE BUILDING LINE 10.6' N OF THE N/S REFERENCE BUILDING LINE 52.8' E OF THE E/W REFERANCE BUILDING LINE 8.8' S OF THE N/S REFERENCE BUILDING LINE 52.6' E OF THE E/W REFERANCE BUILDING LINE 17.1' S OF THE N/S REFERENCE BUILDING LINE 50.7' E OF THE E/W REFERANCE BUILDING LINE 15.7' S OF THE N/S REFERENCE BUILDING LINE 9.6' W OF THE E/W REFERANCE BUILDING LINE 17.3' S OF THE N/S REFERENCE BUILDING LINE 9.3' W OF THE E/W REFERANCE BUILDING LINE 16.9' S OF THE N/S REFERENCE BUILDING LINE 15.4' W OF THE E/W REFERANCE BUILDING LINE 14.7' S OF THE N/S REFERENCE BUILDING LINE 32.8' W OF THE E/W REFERANCE BUILDING LINE 21.9' N OF THE N/S REFERENCE BUILDING LINE 28.0' W OF THE E/W REFERANCE BUILDING LINE 45.0' N OF THE N/S REFERENCE BUILDING LINE 27.0' W OF THE E/W REFERANCE BUILDING LINE 49.3' N OF THE N/S REFERENCE BUILDING LINE 23.4' W OF THE E/W REFERANCE BUILDING LINE 21.8' N OF THE N/S REFERENCE BUILDING LINE 28.7' W OF THE E/W REFERANCE BUILDING LINE 21.6' N OF THE N/S REFERENCE BUILDING LINE 23.5' W OF THE E/W REFERANCE BUILDING LINE 21.1' N OF THE N/S REFERENCE BUILDING LINE 8.5' E OF THE E/W REFERANCE BUILDING LINE 21.0' N OF THE N/S REFERENCE BUILDING LINE 14.3' E OF THE E/W REFERANCE BUILDING LINE