HomeMy WebLinkAboutAs Built Utility Plans 0618244"X2" TEE W/ 7 LF OF 2"
COPPER TO STANDARD
METER ASSEMBLY
SSSSSSS
S
S
S
S
S
S
D
D
D
SSS
XXXXXXXXXXXXXXXWWWWWWWWWWWWWWWWWWWWWW
W M
W W W W WFH
A
B
C
FG
H
I
J
K
L
M
MAIN B
EXISTING
BUILDING 2
EXISTING
BUILDING #3
PROPOSED
BUILDING #2
W M
W M
15 LF OF 4" D.I. PIPE
17 LF OF 4" D.I. PIPE
18 LF OF 4" D.I. PIPE
9 LF OF 4" D.I. PIPE
7 LF OF 4" D.I. PIPE
15 LF OF 4" D.I. PIPE
60 LF OF 6" D.I. PIPE 27 LF OF 6" D.I. PIPE
CLOW FIRE STANDARD
HYDRANT ASSY.
2' S OF VALVE #_______
8"x6" TAPPING SLEEVE
T.B. #1
T.B. #2
T.B. #3
T.B. #4
T.B. #5CURB REFERENCE FOREAST/WEST LINE, POINTS D-ICURB REFERENCE FOR
NORTH/SOUTH LINE, POINTS D-I
T.B. #6
T.B. #7
T.B. #8
T.B. #9
68 LF OF 4"
D.I. PIPET.B. #10
T.B. #11
T.B. #12
T.B. #13
57 LF OF 4" D.I. PIPE
83 LF OF 4"
D.I. PIPE
49 LF OF 4" D.I. PIPE
ANCHOR
COLLAR
M.B. #1
M.B. #2
8"X2" TAP W/5 LF OF 2"
COPPER TO STANDARD
METER ASSEMBLY
WATER
BELOW
STORM
WATER BELOW STORM
WATER BELOW STORM
WATER BELOW STORM
8"X2" TAP W/5 LF OF 2"
COPPER TO STANDARD
METER ASSEMBLY
P
Q
CURB REFERANCE FOR EAST/WESTLINE, POINTS A&B,P&QCURB REFERANCE FOR NORTH/SOUTH
LINE, POINTS A&B,P&Q
CURB REFERANCEFOR EAST/WESTLINE, POINT CCURB REFERANCE
FOR NORTH/SOUTH
LINE, POINT CBUILDING REFERANCE FOREAST/WEST LINE, POINTS J-LBUILDING REFERENCE FOR
NORTH/SOUTH LINE, POINTS J-L
BUILDING REFERANCE FOREAST/WEST LINE, POINTS M-OBUILDING REFERANCE FOR
NORTH/SOUTH LINE, POINTS M-O
EXISTING 8"
WATER LINE
1 inch = 10ft.
( IN FEET )
PLAN SCALE
0 5 10 2010
Project IDCAD File Name
2021-0015
OUR HOUSE SITEWORK
302 E. Roosevelt Rd.
Little Rock, AR 72206
No.Date Issue Notes
Date
SET-A
1 2 3 4 5
54321
A
B
C
DD
C
B
A
CONSULTING
ENGINEERS, INC.
McCLELLAND
D E S I G N E D T O S E R V E
HTTP://WWW.MCE.US.COM
7302 KANIS ROAD
LITTLE ROCK, ARKANSAS 72204
PH: (501) 371-0272 CA401
Overall Utility
As-Built Plan
22-5716 DESIGN.DWG
TOPOGRAPHIC AND BOUNDARY SURVEY PROVIDED BY OTHERS.
CONTRACTOR SHALL REVIEW AND VERIFY ALL EXISTING
ELEVATIONS AND FLOWLINE INFORMATION IN THE FIELD AND
NOTIFY ENGINEER WITH POTENTIAL CONFLICTS
FDC
PROPOSED LEGEND
GAS LINE
GAS METER
OVERHEAD ELECTRIC LINE
UNDERGROUND ELECTRIC LINE
WATER LINE
FIRE DEPARTMENT CONNECTION
FIRE HYDRANT
WATER METER
WATER VALVE
REDUCER
SANITARY SEWER LINE
SANITARY SEWER MANHOLE
CLEAN-OUT
POWER POLE/POWER POLE & GUY
CATCH BASIN
GAS
OHE
UGE
X''W
W MW
G
FH
D
S
D
400 POINT OF CONNECTION - WATER SERVICE
401 FIRE SPRINKLER BUILDING ENTRY (SEE ARCH. PLANS) - SHOULD THE FIRE
DESIGN FROM THE FIRE CONSULTANT DEVIATE IN ANY WAY FROM THE CIVIL
UTILITY SITE PLAN, THE CONTRACTOR SHALL CONTACT THE ENGINEER OF
RECORD FOR COORDINATION PRIOR TO THE START OF CONSTRUCTION
402 DOMESTIC WATER SERVICE BUILDING ENTRY (SEE ARCH. / MEP PLANS)
404 FIRE DEPARTMENT CONNECTION (PER LOCAL CODES)
406 PROPOSED WATER METER (SEE SIZE AT SYMBOL)
423 SANITARY SEWER SERVICE BUILDING ENTRY (SEE ARCH. / MEP PLANS)
424 ADJUST EXISTING SANITARY SEWER MANHOLE RIM TO MATCH FINISH GRADES
428 CONNECT TO EXISTING SANITARY SEWER MANHOLE
432 ELECTRIC BUILDING ENTRY (SEE ARCH. / MEP PLANS)
441 POINT OF CONNECTION - NATURAL GAS SERVICE (PER GAS COMPANY
REQUIREMENTS)
442 NATURAL GAS METER
443 NATURAL GAS BUILDING ENTRY (SEE ARCH. / MEP PLANS)
UTILITY KEYNOTES
OWNER/ DEVELOPER
COMPANY NAME: OUR HOUSE, INC.
STREET: 302 E ROOSEVELT RD.
CITY, STATE ZIP: LITTLE ROCK, AR 72206
NAME / TITLE: MR MATT RUNGE,
DIRECTOR OF OPERATIONS
PHONE: 501-374-7383 EXT. 163
EMAIL:
MATT.RUNGE@OURHOUSESHELTER.ORG
CIVIL ENGINEERING CONSULTANT
COMPANY NAME: MCCLELLAND
CONSULTING ENGINEERS, INC.
STREET: 7302 KANIS ROAD
CITY, STATE ZIP: LITTLE ROCK, AR 72204
NAME / TITLE:DAN BERANEK, PE,
PRESIDENT MCE-LITTLE ROCK
PHONE:(501) 371.0272
EMAIL:DBERANEK@MCE.US.COM
CONTACTS
HYDRANT FLOW TEST INFORMATION
DATE OF TEST 06/10/2022
MEASURED FLOW 1,500 GPM
STATIC PRESSURE 84 PSI
RESIDUAL PRESSURE 79 PSI
05/13/22
D
E
6"X6"
(MJ) TEE
6"X12"
D.I.
SWIVEL
ADAPTER
6"X12"
D.I.
SWIVEL
ADAPTER
MAIN B - Point Table
Point #
MB-A
MB-B
MB-C
MB-D
MB-E
MB-F
MB-G
MB-H
MB-I
MB-J
MB-K
MB-L
MB-M
MB-N
MB-O
Description Location
6" GATE VALVE
M&H OPEN R 21 TURNS
6" (MJ) 90° BEND
6" GATE VALVE
M&H OPEN R 21 TURNS (2' N OF F.H.)
6" GATE VALVE
M&H OPEN R 21 TURNS
4" (MJ) 45° BEND
4" (MJ) 22.5° BEND
4" (MJ) 22.5° BEND
4" (MJ)11.25° BEND
2" GATE VALVE
M&H OPEN L 9 TURNS
4" (MJ) 90° BEND
4" (MJ) 11.25° BEND
4" (MJ) 11.25° BEND
4" (MJ) 90° BEND
4" STAINLESS STEEL FIRE RISER
WITH PORTED CAP
1.4' N OF THE N/S REFERANCE CURB LINE
50.7' W OF THE E/W REFERANCE CURB LINE
4" D.I. PIPE TO FIRE RISER
CONNECTION POINT
MB-P
MB-Q 2" GATE VALVE M&H OPEN L 9 TURNS
2" GATE VALVE M&H OPEN L 9 TURNS
5.9' N OF THE N/S REFERENCE BUILDING LINE
6.1' W OF THE E/W REFERENCE BUILDING LINE
25.2' S OF THE N/S REFERANCE CURB LINE
49.6' W OF THE E/W REFERANCE CURB LINE
49.4' N OF THE N/S REFERANCE CURB LINE
9.0' W OF THE E/W REFERANCE CURB LINE
43.6' N OF THE N/S REFERANCE CURB LINE
9.1' W OF THE E/W REFERANCE CURB LINE
13.4' S OF THE N/S REFERANCE CURB LINE
12.2' W OF THE E/W REFERANCE CURB LINE
6.9' S OF THE N/S REFERANCE CURB LINE
6.0' W OF THE E/W REFERANCE CURB LINE
3.3' S OF THE N/S REFERANCE CURB LINE
6.5' W OF THE E/W REFERANCE CURB LINE
6.3' N OF THE N/S REFERANCE CURB LINE
18.0' W OF THE E/W REFERANCE CURB LINE
9.3' N OF THE N/S REFERANCE CURB LINE
23.6' W OF THE E/W REFERANCE CURB LINE
11.5' N OF THE N/S REFERANCE CURB LINE
32.7' W OF THE E/W REFERANCE CURB LINE
9.9' N OF THE N/S REFERENCE CURB LINE
50.5' W OF THE E/W REFERENCE CURB LINE
42.7' S OF THE N/S REFERENCE BUILDING LINE
10.1' W OF THE E/W REFERENCE BUILDING LINE
57.6' S OF THE N/S REFERENCE BUILDING LINE
17.3' W OF THE E/W REFERENCE BUILDING LINE
2.0' S OF THE N/S REFERENCE BUILDING LINE
6.4' W OF THE E/W REFERENCE BUILDING LINE
3.6' S OF THE N/S REFERENCE BUILDING LINE
8.7' E OF THE E/W REFERENCE BUILDING LINE
3.6' S OF THE N/S REFERENCE BUILDING LINE
14.7' E OF THE E/W REFERENCE BUILDING LINE
4"X6"
REDUCER
R
6" SS RISER
6' OF STAINLESS
STEEL PIPE
6' OF STAINLESS
STEEL PIPE