Loading...
HomeMy WebLinkAboutAs Built Utility Plans 0618244"X2" TEE W/ 7 LF OF 2" COPPER TO STANDARD METER ASSEMBLY SSSSSSS S S S S S S D D D SSS XXXXXXXXXXXXXXXWWWWWWWWWWWWWWWWWWWWWW W M W W W W WFH A B C FG H I J K L M MAIN B EXISTING BUILDING 2 EXISTING BUILDING #3 PROPOSED BUILDING #2 W M W M 15 LF OF 4" D.I. PIPE 17 LF OF 4" D.I. PIPE 18 LF OF 4" D.I. PIPE 9 LF OF 4" D.I. PIPE 7 LF OF 4" D.I. PIPE 15 LF OF 4" D.I. PIPE 60 LF OF 6" D.I. PIPE 27 LF OF 6" D.I. PIPE CLOW FIRE STANDARD HYDRANT ASSY. 2' S OF VALVE #_______ 8"x6" TAPPING SLEEVE T.B. #1 T.B. #2 T.B. #3 T.B. #4 T.B. #5CURB REFERENCE FOREAST/WEST LINE, POINTS D-ICURB REFERENCE FOR NORTH/SOUTH LINE, POINTS D-I T.B. #6 T.B. #7 T.B. #8 T.B. #9 68 LF OF 4" D.I. PIPET.B. #10 T.B. #11 T.B. #12 T.B. #13 57 LF OF 4" D.I. PIPE 83 LF OF 4" D.I. PIPE 49 LF OF 4" D.I. PIPE ANCHOR COLLAR M.B. #1 M.B. #2 8"X2" TAP W/5 LF OF 2" COPPER TO STANDARD METER ASSEMBLY WATER BELOW STORM WATER BELOW STORM WATER BELOW STORM WATER BELOW STORM 8"X2" TAP W/5 LF OF 2" COPPER TO STANDARD METER ASSEMBLY P Q CURB REFERANCE FOR EAST/WESTLINE, POINTS A&B,P&QCURB REFERANCE FOR NORTH/SOUTH LINE, POINTS A&B,P&Q CURB REFERANCEFOR EAST/WESTLINE, POINT CCURB REFERANCE FOR NORTH/SOUTH LINE, POINT CBUILDING REFERANCE FOREAST/WEST LINE, POINTS J-LBUILDING REFERENCE FOR NORTH/SOUTH LINE, POINTS J-L BUILDING REFERANCE FOREAST/WEST LINE, POINTS M-OBUILDING REFERANCE FOR NORTH/SOUTH LINE, POINTS M-O EXISTING 8" WATER LINE 1 inch = 10ft. ( IN FEET ) PLAN SCALE 0 5 10 2010 Project IDCAD File Name 2021-0015 OUR HOUSE SITEWORK 302 E. Roosevelt Rd. Little Rock, AR 72206 No.Date Issue Notes Date SET-A 1 2 3 4 5 54321 A B C DD C B A CONSULTING ENGINEERS, INC. McCLELLAND D E S I G N E D T O S E R V E HTTP://WWW.MCE.US.COM 7302 KANIS ROAD LITTLE ROCK, ARKANSAS 72204 PH: (501) 371-0272 CA401 Overall Utility As-Built Plan 22-5716 DESIGN.DWG TOPOGRAPHIC AND BOUNDARY SURVEY PROVIDED BY OTHERS. CONTRACTOR SHALL REVIEW AND VERIFY ALL EXISTING ELEVATIONS AND FLOWLINE INFORMATION IN THE FIELD AND NOTIFY ENGINEER WITH POTENTIAL CONFLICTS FDC PROPOSED LEGEND GAS LINE GAS METER OVERHEAD ELECTRIC LINE UNDERGROUND ELECTRIC LINE WATER LINE FIRE DEPARTMENT CONNECTION FIRE HYDRANT WATER METER WATER VALVE REDUCER SANITARY SEWER LINE SANITARY SEWER MANHOLE CLEAN-OUT POWER POLE/POWER POLE & GUY CATCH BASIN GAS OHE UGE X''W W MW G FH D S D 400 POINT OF CONNECTION - WATER SERVICE 401 FIRE SPRINKLER BUILDING ENTRY (SEE ARCH. PLANS) - SHOULD THE FIRE DESIGN FROM THE FIRE CONSULTANT DEVIATE IN ANY WAY FROM THE CIVIL UTILITY SITE PLAN, THE CONTRACTOR SHALL CONTACT THE ENGINEER OF RECORD FOR COORDINATION PRIOR TO THE START OF CONSTRUCTION 402 DOMESTIC WATER SERVICE BUILDING ENTRY (SEE ARCH. / MEP PLANS) 404 FIRE DEPARTMENT CONNECTION (PER LOCAL CODES) 406 PROPOSED WATER METER (SEE SIZE AT SYMBOL) 423 SANITARY SEWER SERVICE BUILDING ENTRY (SEE ARCH. / MEP PLANS) 424 ADJUST EXISTING SANITARY SEWER MANHOLE RIM TO MATCH FINISH GRADES 428 CONNECT TO EXISTING SANITARY SEWER MANHOLE 432 ELECTRIC BUILDING ENTRY (SEE ARCH. / MEP PLANS) 441 POINT OF CONNECTION - NATURAL GAS SERVICE (PER GAS COMPANY REQUIREMENTS) 442 NATURAL GAS METER 443 NATURAL GAS BUILDING ENTRY (SEE ARCH. / MEP PLANS) UTILITY KEYNOTES OWNER/ DEVELOPER COMPANY NAME: OUR HOUSE, INC. STREET: 302 E ROOSEVELT RD. CITY, STATE ZIP: LITTLE ROCK, AR 72206 NAME / TITLE: MR MATT RUNGE, DIRECTOR OF OPERATIONS PHONE: 501-374-7383 EXT. 163 EMAIL: MATT.RUNGE@OURHOUSESHELTER.ORG CIVIL ENGINEERING CONSULTANT COMPANY NAME: MCCLELLAND CONSULTING ENGINEERS, INC. STREET: 7302 KANIS ROAD CITY, STATE ZIP: LITTLE ROCK, AR 72204 NAME / TITLE:DAN BERANEK, PE, PRESIDENT MCE-LITTLE ROCK PHONE:(501) 371.0272 EMAIL:DBERANEK@MCE.US.COM CONTACTS HYDRANT FLOW TEST INFORMATION DATE OF TEST 06/10/2022 MEASURED FLOW 1,500 GPM STATIC PRESSURE 84 PSI RESIDUAL PRESSURE 79 PSI 05/13/22 D E 6"X6" (MJ) TEE 6"X12" D.I. SWIVEL ADAPTER 6"X12" D.I. SWIVEL ADAPTER MAIN B - Point Table Point # MB-A MB-B MB-C MB-D MB-E MB-F MB-G MB-H MB-I MB-J MB-K MB-L MB-M MB-N MB-O Description Location 6" GATE VALVE M&H OPEN R 21 TURNS 6" (MJ) 90° BEND 6" GATE VALVE M&H OPEN R 21 TURNS (2' N OF F.H.) 6" GATE VALVE M&H OPEN R 21 TURNS 4" (MJ) 45° BEND 4" (MJ) 22.5° BEND 4" (MJ) 22.5° BEND 4" (MJ)11.25° BEND 2" GATE VALVE M&H OPEN L 9 TURNS 4" (MJ) 90° BEND 4" (MJ) 11.25° BEND 4" (MJ) 11.25° BEND 4" (MJ) 90° BEND 4" STAINLESS STEEL FIRE RISER WITH PORTED CAP 1.4' N OF THE N/S REFERANCE CURB LINE 50.7' W OF THE E/W REFERANCE CURB LINE 4" D.I. PIPE TO FIRE RISER CONNECTION POINT MB-P MB-Q 2" GATE VALVE M&H OPEN L 9 TURNS 2" GATE VALVE M&H OPEN L 9 TURNS 5.9' N OF THE N/S REFERENCE BUILDING LINE 6.1' W OF THE E/W REFERENCE BUILDING LINE 25.2' S OF THE N/S REFERANCE CURB LINE 49.6' W OF THE E/W REFERANCE CURB LINE 49.4' N OF THE N/S REFERANCE CURB LINE 9.0' W OF THE E/W REFERANCE CURB LINE 43.6' N OF THE N/S REFERANCE CURB LINE 9.1' W OF THE E/W REFERANCE CURB LINE 13.4' S OF THE N/S REFERANCE CURB LINE 12.2' W OF THE E/W REFERANCE CURB LINE 6.9' S OF THE N/S REFERANCE CURB LINE 6.0' W OF THE E/W REFERANCE CURB LINE 3.3' S OF THE N/S REFERANCE CURB LINE 6.5' W OF THE E/W REFERANCE CURB LINE 6.3' N OF THE N/S REFERANCE CURB LINE 18.0' W OF THE E/W REFERANCE CURB LINE 9.3' N OF THE N/S REFERANCE CURB LINE 23.6' W OF THE E/W REFERANCE CURB LINE 11.5' N OF THE N/S REFERANCE CURB LINE 32.7' W OF THE E/W REFERANCE CURB LINE 9.9' N OF THE N/S REFERENCE CURB LINE 50.5' W OF THE E/W REFERENCE CURB LINE 42.7' S OF THE N/S REFERENCE BUILDING LINE 10.1' W OF THE E/W REFERENCE BUILDING LINE 57.6' S OF THE N/S REFERENCE BUILDING LINE 17.3' W OF THE E/W REFERENCE BUILDING LINE 2.0' S OF THE N/S REFERENCE BUILDING LINE 6.4' W OF THE E/W REFERENCE BUILDING LINE 3.6' S OF THE N/S REFERENCE BUILDING LINE 8.7' E OF THE E/W REFERENCE BUILDING LINE 3.6' S OF THE N/S REFERENCE BUILDING LINE 14.7' E OF THE E/W REFERENCE BUILDING LINE 4"X6" REDUCER R 6" SS RISER 6' OF STAINLESS STEEL PIPE 6' OF STAINLESS STEEL PIPE