HomeMy WebLinkAboutPC Minutes for S-1962 061324June 13, 2024
ITEM NO.: 1 FILE NO.: S-1962
NAME: Camila Addition – Preliminary Plat
LOCATION: 11308 and 11606 Dreher Road
DEVELOPER:
JRC Land and Houses for Sale, LLC
5710 Atwood Road
Little Rock, AR 72206
OWNER/AUTHORIZED AGENT:
JRC Land and Houses for Sale, LLC – Owner
Stan Cunningham – Agent
SURVEYOR/ENGINEER:
Garnat Engineering, LLC
3825 Mt. Carmel Road
Bryant, AR 72022
AREA: 9.62-acres NUMBER OF LOTS: 7 FT. NEW STREET: 0 LF
WARD: N/A PLANNING DISTRICT: 23 CENSUS TRACT: 40.06
CURRENT ZONING: Not Zoned
VARIANCE/WAIVERS:
1. Variance to allow one (1) pipe stem lot.
2. Waiver of boundary street improvements.
A. PROPOSAL/REQUEST/APPLICANT’S STATEMENT:
The applicant is requesting preliminary plat approval to allow 9.62 acres of property
located at 11308 and 11606 Dreher Road to be subdivided into seven (7) lots for
single family residential development.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
2
B. EXISTING CONDITIONS:
The property is currently comprised of two (2) acreage tracts, each being
approximately five (5) acres in size. A single family residence is located on each
of the two (2) tracts.
C. NEIGHBORHOOD NOTIFICATIONS:
All owners of property abutting the site and all neighborhood associations
registered with the City of Little Rock were notified of the public hearing.
D. ENGINEERING COMMENTS:
1. Show existing right of way for Dreher Road on preliminary plat.
2. Any work involving one (1) or more acres of disturbed area requires a State
of Arkansas NPDES permit. Contact the Arkansas Department of
Environmental Quality, NPDES branch at 501-682-0744 for applications and
information about General Stormwater Discharge Construction Permit
#ARR150000.
3. Any additional permits other than from the State of Arkansas required for
clearing, grading, and construction of future residential structures will be
through Pulaski County Planning and Development Department at
501-340-8260.
4. Per City Code 31-89 (5) for a preliminary plat, a storm drainage preliminary
analysis is required showing drainage data for all watercourses entering and
leaving the plat illustrate the proposed system’s capability of accommodating
storm events as required by the stormwater management and drainage
manual. The preliminary plat shall also show drainage arrows indicating how
drainage arrives at the site and drainage arrows how it leaves the site post
development. Indicate where the storm sewer pipes and curb inlets are
located within the development also. Additionally, provide profile and cross-
sectional views of the detention structure outlet/spillway and detention
calculations for the 25- and 100-year storm for the proposed detention
pond/structure. Delineation of the drainage areas pre and post construction
with respective discharges via rational method shall also be shown. The
preliminary plat shall also contain all information as outlined in City Code
Sec. 31-89 and 31-90.
5. Dreher Road is classified as a collector per City’s master street plan. Per
collector street standard per master street plan, a total of sixty (60) feet of
right of way is required for a collector street. Therefore, the developer will be
required to dedicate a total thirty (30) feet of right of way from the existing
centerline of Dreher Road to meet master street plan requirements.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
3
6. Lot 7 does not meet the minimum requirements for lot size and depth to width
ratio per City Code Sec. 31-232 (a) and (b). Lot 7 is also a pipestem lot which
is prohibited for residential subdivisions per City Code Sec. 31-232 (f).
Therefore, three variances from the subdivision code mentioned previously
shall be requested from the Little Rock Planning Commission for their
consideration if Lot 7 is desired to remain as currently proposed on the
preliminary plat.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: No comments.
Entergy: No comments received.
Summit Utilities: No comments.
AT & T: No comments received.
Central Arkansas Water: NO OBJECTIONS; All Central Arkansas Water
requirements in effect at the time of request for water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads
shall not exceed 10 percent in grade except as approved by the fire chief. If
the grade exceeds 10 percent, approval will be denied and the applicant must
submit request to be reviewed by Fire Chief for Approval.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
4
Commercial and Industrial Developments – 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height.
Building or facilities exceeding 30 feet or three stories in height shall have at least
two means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
30’ Tall Buildings - Maintain aerial fire apparatus access roads as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D105.1
– D105.4
D105.1 Where Required. Where the vertical distance between the grade
plane and the highest roof surface exceed 30’, approved aerial fire apparatus
access roads shall be provided. For the purposes of this section the highest roof
surfaces shall be determined by measurement to the eave of a pitched roof, the
intersection of a roof to the exterior wall, or the top of the parapet walls, whichever
is greater.
D105.2 Width. Aerial fire apparatus access roads shall have a minimum
unobstructed with of 26’, exclusive of shoulders, in the immediate vicinity of the
building or portion thereof.
D105.3 Proximity to building. At least one of the required access routes
meeting this condition shall be located within a minimum of 15 feet and a maximum
of 30 feet from the building, and shall be positioned parallel to one entire side of
the building. The side of the building on which the aerial fire apparatus access
road is positioned shall be approved by the fire code official.
D105.4 Obstructions. Overhead utility and power lines shall not be located
over the aerial fire apparatus access road or between the aerial fire apparatus road
and the building. Other obstructions shall be permitted to be places with the
approval of the fire code official.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
5
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply
with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times
and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the fire
code official.
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Multi-Family Residential Developments
As per Appendix D, Section D106.1 of the 2012 Arkansas Fire Prevention
Code Vol. 1. Projects having more than 100 dwelling units. Multiple-family
residential projects having more than 100 dwelling units shall be equipped
throughout with two separate and approved fire apparatus access roads.
Exception: Projects having up to 200 dwelling units may have a single
approved fire apparatus access road when all building, including nonresidential
occupancies are equipped throughout with approved automatic sprinkler systems
installed in accordance with Section 903.3.1.1 or 903.3.1.2.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
6
As per Appendix D, Section D106.2 of the 2012 Arkansas Fire prevention
Code Vol. 1. Projects having more than 200 dwelling units. Multiple-family
residential projects having more than 200 dwelling units shall be provided with two
separate and approved fire apparatus access roads regardless of whether they
are equipped with an approved automatic sprinkler system.
One- or Two-Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two-Family dwelling residential developments. Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 – C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal’s Office
(Capt. Tony Rhodes 501-918-3757, or Fire Marshal Derek N. Ingram
501-918-3756 Number and Distribution of Fire Hydrants as per Table C105.1.
If you have any additional questions please contact our office. Contact
Capt. Tony Rhodes at (501) 918-3757, or Fire Marshal Derek N. Ingram
(501) 918-3756.
Parks and Recreation: No comments received.
County Planning: No comments.
F. BUILDING CODES/LANDSCAPE:
Building Code: No comments received.
Landscape: No comments.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
7
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comments received.
Planning Division: No comments.
H. ANALYSIS:
The applicant requesting preliminary plat approval to allow 9.62 acres of property
located at 11308 and 11606 Dreher Road to be subdivided into seven (7) lots for
single family residential development.
The property is located outside the city limits and is not zoned. The property is
located within the City’s Extraterritorial Subdivision Jurisdiction.
The property is currently comprised of two (2) acreage tracts, each being
approximately five (5) acres in size. A single family residence is located on each
of the two (2) tracts.
The proposed lot sizes will be as follows:
Lot 1 – 54,182 sq. ft. (1.24 acres)
Lot 2 – 44,211 sq. ft. (1.01 acres)
Lot 3 – 44,407 sq. ft. (1.02 acres)
Lot 4 – 34,571 sq. ft. (0.79 acres)
Lot 5 – 64,753 sq. ft. (1.49 acres)
Lot 6 – 46,797 sq. ft. (1.07 acres)
Lot 7 – 88,318 sq. ft. (2.03 acres)
The applicant is requesting a variance from Section 31-232 (f) of the City’s
Subdivision Ordinance to allow Lot 7 as a pipe stem lot. Staff supports the variance
request.
The applicant is dedicating additional right-of-way for Dreher Road as part of the
proposed plat. The applicant is requesting a waiver of boundary street
improvements for the roadway. Staff also supports this waiver request.
There is additional information, including a drainage analysis, which the applicant
has not provided to staff. Therefore, staff recommends this application be deferred
to the May 9, 2024 Planning Commission agenda.
June 13, 2024
ITEM NO.: 1 (Cont.) FILE NO.: S-1962
8
I. STAFF RECOMMENDATION:
Staff recommends approval of the proposed preliminary plat subject to compliance
with the comments and conditions outlined in paragraphs D and E, and the staff
analysis, of the agenda staff report.
PLANNING COMMISSION ACTION: (APRIL 11, 2024)
This item was deferred to the May 9, 2024 agenda, as the applicant needed to submit
additional information to staff.
PLANNING COMMISSION ACTION: (MAY 9, 2024)
This item was deferred to the June 13, 2024 agenda, as the applicant needed to submit
additional information to staff.
STAFF UPDATE:
The applicant submitted the required additional information to staff, including the
preliminary drainage analysis and letter from the Arkansas Department of Health
approving the septic systems for the proposed lots. The Department of Planning and
Development Engineering Division has reviewed the preliminary drainage analysis. With
the additional information submittal, staff supports the preliminary plat application.
PLANNING COMMISSION ACTION: (JUNE 13, 2024)
The applicant was present. The application was pulled off the Consent Agenda. Staff
presented the item and a recommendation of approval as outlined in the “staff analysis”
above. There were nine persons registered in opposition. Stanley Pollard, Carline Clella,
Kenneth Pryor, Kevin Strayhorn, Virginia Pollard, Margaret Dreher, Jeff Dreher, Darlene
Davis and Dennis Davis spoke about concerns of traffic and overcrowding. After
extensive discussion, there was a motion to approve the application. There was a
second. The vote was 10 ayes, 0 nays and 1 absent. The motion was approved.