HomeMy WebLinkAboutS-0662-A Staff AnalysisITEM NO.: 9.
NAME: J.A. Riggs Tractor Subdivision Site Plan Review
LOCATION: located at 9125 Interstate 30
Planning Staff Comments:
S-662-A
1. Provide notification of property owners located within 200 feet of the site, complete
with the certified abstract list, notice form with affidavit executed and proof of
mailing. The notice must be mailed no later than May 9, 2007. The Office of
Planning and Development must receive the proof of notice no later than May 16,
2007.
2. Provide the dimension of the street buffer proposed.
3. Provide a time frame for the phasing of the development.
4. Provide details of the proposed fencing including height and construction material.
5. Provide details of any existing signage and any proposed signage including building
signage.
Variance/Waivers:
1. A variance from the Zoning Ordinance to allow a reduced street buffer.
Public Works Conditions:
1. Sidewalks with appropriate handicap ramps are required in accordance with Section
31-175 of the Little Rock Code and the Master Street Plan. The sidewalk should be
completed along Chicot Road to the bridge.
2. A grading permit in accordance with Section 29-186 (c) and (d) will be required prior
to any land clearing or grading activities at the site. Site grading, and drainage plans
will need to be submitted and approved prior to the start of construction.
3. Plans of all work in right-of-way shall be submitted for approval prior to start of work.
Obtain barricade permit prior to doing any work in the right-of-way from Traffic
Engineering at (501) 379-1805 (Travis Herbner).
4. If disturbed area is one (1) or more acres, obtain a NPDES storm water permit from
the Arkansas Department of Environmental Quality prior to the start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per Section 8-283
prior to construction.
6. Street improvement plans shall include signage and striping. Traffic Engineering
must approve completed plans prior to construction.
7. Storm water detention ordinance applies to this property. Show the proposed
location for storm water detention facilities on the plan.
8. In accordance with Section 31-176, floodway areas must be shown as floodway
easements or be dedicated to the public. In addition, a 25-foot wide access
easement is required adjacent to the floodway boundary.
9. Erosion controls must be installed to reduce discharge of polluted storm water.
10.The minimum Finish Floor elevation is required to be shown on plat and grading
Item # 9
plans.
11. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-
of-way prior to occupancy.
Utilities and Fire Department/County Planning:
Wastewater: Sewer available to the property.
Entergy: No comment received.
Center -Point Energy: Approved as submitted.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. Additional on site fire protection will be
required. Contact Central Arkansas Water if larger and/or additional water meter(s) are
required.
Fire Department: Additional fire hydrants may be required. Contact the Little Rock
Fire Department for additional information.
County Planning:
CATA: The site is not located on a dedicated CATA Bus Route.
Planning Division: No comment.
Landscape:
1. Compliance with the City's Landscape and Buffer Ordinances is required.
2. The zoning buffer ordinance requires an average forty-three (43'-0") foot wide street buffer
along the access road. Currently, this site plan is not meeting this minimum requirement.
There should be no new development of any kind in this area.
3. The zoning buffer ordinance requires an average forty-four foot (44'-0") wise street buffer
along Chicot Road. Currently, this site plan is not meeting this minimum requirement.
There should be no new development of any kind in this area.
4. The landscape ordinance requires a minimum thirty foot wide (30'-0") landscape strip along
Interstate 30. Currently, this site plan is not meeting this minimum requirement. A variance
from this requirement must be obtained by the City Beautiful Commission prior to the
issuance of a building permit.
5. This site is located within a scenic corridor for the City of Little Rock thus special attention
should be given to this area.
6. The landscape ordinance requires a minimum nine foot wide landscape strip around the
sites perimeter. A variance from this minimum requirement must be obtained by the City
Beautiful Commission prior to the issuance of a building permit.
7. The landscape ordinance requires a minimum of 8 % of the paved areas be landscaped with
interior islands of at least 7'/z feet in width and 300 square feet in area. Proposed plan does
not currently reflect this minimum.
Item # 9
8. A small amount of building landscaping is also required.
9. Four foot can be taken off of the parking lot depth in 5 areas substantially increasing the
amount of overall green space on the site as well as assisting in meeting the city's minimum
landscape requirements.
10. An automatic irrigation system to water landscaped areas will be required.
11. Prior to the issuance of a building permit, it will be necessary to provide an approved
landscape plan stamped with the seal of a Registered Landscape Architect.
12. The City Beautiful Commission recommends preserving as many existing trees as feasible
on this tree covered site. Credit toward fulfilling Landscape Ordinance requirements can be
given when preserving trees of six (6) inch caliper or larger.
Revised plat/plan. Submit four (4) copies of a revised preliminary plat (to include the
additional information as noted above) to staff on Wednesday, May 9, 2007.
Item # 9
June 7, 2007
ITEM NO.: F
NAME: J.A. Riggs Tractor Subdivision Site Plan Review
LOCATION: Located at 9125 Interstate 30
DEVELOPER:
JA Riggs Tractor Company
9125 Interstate 30
Little Rock, AR 72209
ENGINEER:
McClelland Consulting Engineers, Inc.
P.O. Box 34087
Little Rock, AR 72203
ARCHITECT:
Combined Efforts Design PLLC
201 South 20th Street, Suite 16
Rogers, AR 72758
AREA: 26.9 acres
CURRENT ZONING:
PLANNING DISTRICT:
CENSUS TRACT
NUMBER OF LOTS: 1
R-2, C-3, C-4 and 1-2
15 — Geyer Springs West
41.03
VARIANCES/WAIVERS REQUESTED:
FILE NO.: S-662-A
FT. NEW STREET: 0 LF
1. A variance from the Zoning Ordinance to allow a reduced street buffer.
2. A variance to allow an increased sign height and total sign area.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
Nearly 50 years ago JA Riggs Tractor Company moved from Downtown Little
Rock and built a modern new facility on a site fronting a two-lane highway
outside the southwest edge of the City. As Little Rock grew this area was
annexed into the City, the two-lane highway became Interstate 30, and more
June 7, 2007
ITEM NO.: F (Cont.) FILE NO.: S-662-A
recently road and street modifications through and around the site has shrunk its
size from over 40 acres to 27 acres. It is now surrounded on all sides by roads,
the majority of them one way. These developments, coupled with aging facilities,
has led JA Riggs to develop a Master Plan for a phased redevelopment of the
site to be implemented over the next 20 years. The goals of the redevelopment
and changes proposed are:
GOALS FOR REDEVELOPMENT
PROPOSED CHANGES
• Improve access to and from the site.
a Relocate primary customer access
point to University Avenue.
s Reorient all "customer -facing"
operations toward University
Avenue.
0 Replace and reposition all onsite
signage to direct traffic to new
entrance.
• Improve site security and safety.
• Customer access to equipment
yard limited to drop off and pickup
only. All other traffic diverted
around equipment yard.
o All access to equipment yard will be
via controlled access gates.
■ Employee access and parking
separated from customer access,
shipping and receiving, and
equipment yards.
_
e Improve building and site function
■ Replace the majority of all existing
and appearance.
buildings over the next 20 years.
Expand and improve landscaping,
roads, parking and paving.
■ Use building to screen equipment
service storage areas where
possible.
• Maintain and improve operations
. Phase development to allow
during the rebuilding process.
buildings to be replaced with new,
operations relocated, and the old
ones demolished after that.
• Relocate operations on -site to
maintain or improve operational
efficiencies.
2
June 7, 2007
ITEM NO.: F (Cont.
FILE NO.: S-662-A
Phase One of the plan primarily consists of a single story tilt -up concrete parts
warehouse (52,350 square feet) with an attached two story office/retail sales
space (23,800 square feet) to be built on the east side of the site now used for
equipment display. A major relocation of site access and on -site circulation,
paving, parking and utilities will also occur during this phase. No existing
buildings will be removed during this phase.
Phase Two consists of one small wash bay/truck dyno building (6,800 square
feet) on the west side of the Phase One building. This would consist of a two-
story office addition (29,500 square feet) and a single story equipment shop
(23,550 square feet). At the end of this phase the existing main building that
houses existing parts warehouse and equipment service shop will be demolished
and replaced by employee and equipment service parking.
It is anticipated that the building(s) will be built of a combination of tilt -up
concrete, conventional steel framing, and pre-engineered metal building systems.
Exterior appearance of all buildings will be color coordinated to conform to
Caterpillar corporate identify requirements that consist of a light warm grey
overall color with red, black, or yellow accents. This will be accomplished by
using a combination of low maintenance materials consisting of pre -finished steel
panels, exterior coating systems, brick or tile.
The existing site consists of multiple tracts that were annexed into the City many
years ago many have never been rezoned to a classification that conforms to the
current or future anticipated use. Parallel to this site plan review process Riggs
is requesting a rezoning of the site to 1-2, Light Industrial District as a separate
item on this agenda (Z-3738-A)
The project as planned does not comply with the landscaped buffer ordinance.
The ordinance would typically require the placement of a 38-foot landscape
street buffer along the abutting roadways. The existing site conditions and the
planned development make it difficult for Riggs to comply with the ordinance
requirements.
The request, a key part of Riggs Master Plan, is the first of two phases of the
planned redevelopment. At minimum, Phase one will be implemented
immediately upon approval. Phase Two may be built at the same time
contingent on project costs. If not constructed immediately it is anticipated
Phase Two will be completed within five years.
The applicant is seeking a variance to allow an increased sign height and total
sign area. The signage proposed is a pole sign 60-feet in height and 100 square
feet in area.
3
June 7, 2007
ITEM NO.: F Cont. FILE NO.: 5-662-A
B. EXISTING CONDITIONS:
The site contains a number of buildings currently being used by JA Riggs in their
equipment business. Along the southern boundary of the site is the Cloverdale
Ditch with a wooded area located south of the ditch. The front parking area is
paved and the service yard of the site is graveled.
To the east of the site, across University Avenue, is the Cloverdale Subdivision.
To the west of the site, across Chicot Road, are commercial uses including a gas
station, hotel and strip retail center. North of the site is 1-30. Chicot and South
University Avenue were recently reconstructed. There is not a sidewalk located
along Chicot Road.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. The Cloverdale Neighborhood Association, Southwest Little Rock
United for Progress and all owners of property located within 200-feet of the site
were notified of the Public Hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS.
1. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan. The
sidewalk should be completed along Chicot Road to the bridge.
2. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
3. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Herbner).
4. If disturbed area is one (1) or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
6. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
12
June 7, 2007
ITEM NO.: F (Cont.) FILE NO.: 5-662-A
7. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
8. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25-foot
wide access easement is required adjacent to the floodway boundary.
9. Erosion controls must be installed to reduce discharge of polluted storm
water.
10. The minimum Finish Floor elevation is required to be shown on plat and
grading plans.
11. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to the property.
Entergy: No comment received.
Center -Point Energy: Approved as submitted.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. Additional on site fire
protection will be required. Contact Central Arkansas Water if larger and/or
additional water meter(s) are required.
Fire Department: Additional fire hydrants may be required. Contact the Little
Rock Fire Department for additional information.
County Planninq:
CATA: The site is not located on a dedicated CATA Bus Route.
F. ISSUES/TECHNICAL/DESIGN:
Plannina Division: No comment.
Landscape:
1. Compliance with the City's Landscape and Buffer Ordinances is required.
2. The zoning buffer ordinance requires an average forty-three (43'-0") foot
wide street buffer along the access road. Currently, this site plan is not
5
June 7, 2007
ITEM NO.: F Cont.) FILE NO.: S-662-A
meeting this minimum requirement. There should be no new development
of any kind in this area.
3. The zoning buffer ordinance requires an average forty-four foot (44'-0")
wide street buffer along Chicot Road. Currently, this site plan is not
meeting this minimum requirement. There should be no new development
of any kind in this area.
4. The landscape ordinance requires a minimum thirty foot wide (30'-0")
landscape strip along Interstate 30. Currently, this site plan is not meeting
this minimum requirement. A variance from this requirement must be
obtained by the City Beautiful Commission prior to the issuance of a
building permit.
5. The landscape ordinance requires a minimum nine foot wide landscape
strip around the sites perimeter. A variance from this minimum
requirement must be obtained by the City Beautiful Commission prior to
the issuance of a building permit.
6. The landscape ordinance requires a minimum of 8 % of the paved areas
be landscaped with interior islands of at least 7 Y2 feet in width and 300
square feet in area. Proposed plan does not currently reflect this
minimum.
7. A small amount of building landscaping is also required.
8. Four foot can be taken off of the parking lot depth in 5 areas substantially
increasing the amount of overall green space on the site as well as
assisting in meeting the City's minimum landscape requirements.
9. An automatic irrigation system to water landscaped areas will be required.
10. Prior to the issuance of a building permit, it will be necessary to provide an
approved landscape plan stamped with the seal of a Registered
Landscape Architect.
11. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this tree covered site. Credit toward fulfilling
Landscape Ordinance requirements can be given when preserving trees
of six (6) inch caliper or larger.
G. SUBDIVISION COMMITTEE COMMENT: (May 3, 2007)
The applicant was present representing the request. Staff presented an
overview of the proposed development stating the development was the first step
in implementation of the newly developing Master Plan for J.A. Riggs. Staff
stated the request included a variance to allow a reduced street buffer. Staff
stated all on -site areas would be paved with the exception of the equipment
storage area. Staff stated the time frame for completion of the two phases
proposed for development was two to five years.
9
June 7, 2007
ITEM NO.: F Cont.)FILE NO.: S-662-A
Public Works comments were addressed. Staff stated a 25-foot access
easement should be indicated on the proposed site plan adjacent to the drainage
structures. Staff also stated a sidewalk along Chicot Road was required to extend
from the current terminus to the southern boundary of the property. Staff also
stated a minimum finish floor elevation was required to be shown on the plat and
grading plans.
Landscape comments were addressed. Staff stated a nine foot minimum
landscape strip was required around the perimeter of the site and a 30-foot
minimum landscape strip was required along 1-30. Staff stated variances from
this minimum requirement would require approval from the City Beautiful
Commission. Staff noted the indicated site plan did not include the typically
required street buffers along University Avenue and Chicot Road.
Staff noted comments from the various other reporting departments and
agencies suggesting the applicant contact them directly for additional information
and clarification. There was no further discussion of the item. The Committee
then forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the May 3, 2007, Subdivision Committee meeting. The revised site plan
indicates the reduced street buffer along the abutting roadways. The revised
plan also indicates a 25-foot access easement along the floodway as required by
Section 31-176 of the Little Rock Code of Ordinances.
The applicant is seeking site plan approval for the implementation of a master
plan for the company. The site plan indicates the plan will be constructed in two
phases with the first phase beginning immediately upon approval and the second
phase being completed within five years.
The first phase consists of a single story parts warehouse (52,350 square feet)
with an attached two story office/retail sales space (23,800 square feet) to be
built on the east side of the site now used for equipment display. As a part of this
phase access to the site and on -site circulation, paving, parking and utilities will
occur. No existing buildings will be removed during this construction phase.
The second phase consists of one small wash bay/truck dyno building
(6,800 square feet) on the west side of the parts warehouse - office/retail sales
building. This building is proposed with a two-story office addition
(29,500 square feet) and a single story equipment shop (23,550 square feet). At
the end of this phase the existing main building that houses parts warehouse and
equipment service shop will be demolished and replaced by employee and
equipment service parking.
7
June 7, 2007
ITEM NO.: F (Cont.
FILE NO.: S-662-A
The existing site consists of multiple tracts that were annexed into the City many
years ago many have never been rezoned to a classification that conforms to the
current or future anticipated use. As a separate item on this agenda (Z-3738-A)
the applicant is requesting a rezoning of the site from various zoning
classifications to 1-2, Light Industrial District.
As proposed the plan does not fully comply with the landscaped buffer ordinance.
The landscape ordinance requires a minimum nine foot wide landscape strip
around the site's perimeter. The site plan does meet this typical minimum
requirement. The zoning buffer ordinance typically requires a forty-three foot
wide average street buffer along the access road, a forty-four foot wide average
street buffer along Chicot Road and a thirty foot wide minimum landscape strip
along Interstate 30. Currently, this site plan is not meeting these minimum
requirements. The applicant will seek a variance from the City Beautiful
Commission to allow the reduced landscape strip along Interstate 30. Staff is
supportive of the variance request.
The applicant is seeking a variance to allow an increased sign height and total
sign area. The signage proposed is a pole sign 60-feet in height and 100 square
feet in area. The ordinance typically allows a maximum sign height of 30-feet
and a maximum sign area of 72-square feet. Staff is supportive of an increased
sign area and height but staff recommends the applicant be limited to a single
ground mounted sign along the Frontage Road (north perimeter) and the height
of the sign be measured as allowed in Section 36-557(b) of the Zoning
Ordinance. This section allows sign heights for all ground -mounted on -premise
signs located on properties immediately adjacent to and contiguous to an
expressway or freeway to be measured from the elevation of the centerline of the
traffic lanes (excluding frontage roads) adjacent to subject property to the top of
the sign structure. It shall be the responsibility of the sign owner to submit all
necessary information when this approach is used.
Staff is supportive of the proposed site plan review and the variances associated
with the request. The request is a key part of Riggs Master Plan and is the first
of two phases of the planned redevelopment. Staff does not feel the requested
variance to allow a reduced landscape strip along the abutting roadways or the
increased sign area and sign height will adversely impact the development or the
area. To staffs knowledge there are no outstanding issues associated with the
request.
STAFF RECOMMENDATIONS:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
L3
June 7, 2007
ITEM NO.: F (Cont.
FILE NO.: S-662-A
Staff recommends approval of the variance request to allow a reduced street
buffer along the abutting roadways.
Staff recommends approval of the variance request to allow an increased sign
area and increased sign height along the northern perimeter of the site. Staff
recommends the height be measured as allowed in Section 36-557(b) of the
zoning ordinance.
PLANNING COMMISSION ACTION:
(MAY 24, 2007)
The applicant was present. There were no registered objectors present. The Chairman
explained to the applicant that when fewer than eight (8) Commissioners were present
the Commission routinely allowed the applicant to seek a deferral to a later public
hearing date to allow for additional Commissioner to be present when deciding the
applicant's request. The Chair stated one of the Commissioners present would be
recusing from the vote on this item which did not allow the required six votes to approve
the request. The Chair offered two dates for the deferral request one June 7, 2007, the
second July 5, 2007, and questioned the applicant as to which date they desired their
request to be heard. The applicant stated the June 7, 2007, public hearing date was
acceptable.
There was no further discussion of the item. The Chair entertained a motion for
placement of the item on the June 7, 2007, public hearing docket. A vote of 5 ayes,
0 noes, 4 absent, 1 recusal (Troy Laha) and 1 open position was registered.
STAFF UPDATE:
Staff indicated in the Analysis Section the applicant would be required to seek a
variance from the City Beautiful Commission concerning the allowance for a reduced
landscape strip along Interstate 30. This statement is incorrect. The applicant is
meeting the typical minimum requirements of the Landscape Ordinance and will not be
required to seek approval from the City Beautiful Commission. The applicant is seeking
a variance from the typical buffer ordinance requirements, which is approval by the
Commission, for a reduced landscape strip along the abutting roadways.
PLANNING COMMISSION ACTION: (JUNE 7, 2007)
The applicant was present representing the request. There were no registered
objectors present. Staff presented the item with a recommendation of approval of the
request subject to compliance with the comments and conditions as outlined in
paragraphs D, E and F of the agenda staff report. Staff stated there was an incorrect
statement in the agenda indicating the applicant would be required to seek approval
from the City Beautiful Commission. Staff stated the indicated landscaping did comply
June 7, 2007
ITEM NO.: F (Cont.
FILE NO.: 5-662-A
with the minimum requirements of the Landscape ordinance. Staff presented a
recommendation of approval of the variance request to allow a reduced street buffer
along the abutting roadways. Staff stated the applicant's revised site plan did comply
with the typical requirements of the Landscape Ordinance therefore no approvals from
City Beautiful Commission were required. Staff also presented a recommendation of
approval of the variance request to allow an increased sign area and increased sign
height along the northern perimeter of the site. Staff presented a recommendation the
height of the sign be measured as allowed in Section 36-557(b) of the zoning ordinance.
There was no further discussion of the item. The chair entertained a motion for
placement of the item on the Consent Agenda for Approval. The motion carried by a
vote of 8 ayes, 0 noes, 1 absent, 1 abstention (Commissioner Laha) and 1 open
position.
June 7, 2007
ITEM NO.: F FILE NO.: S-662-A
NAME: J.A. Riggs Tractor Subdivision Site Plan Review
LOCATION: Located at 9125 Interstate 30
DEVELOPER:
JA Riggs Tractor Company
9125 Interstate 30
Little Rock, AR 72209
INre1101a:"-.
McClelland Consulting Engineers, Inc.
P.O. Box 34087
Little Rock, AR 72203
AR(-HITFr..T-
Combined Efforts Design PLLC
201 South 20th Street, Suite 16
Rogers, AR 72758
AREA: 26.9 acres
CURRENT ZONING:
CENSUS TRACT
NUMBER OF LOTS: 1
R-2, C-3, C-4 and 1-2
15 — Geyer Springs West
41.03
VARIANCES/WAIVERS REQUESTED:
FT. NEW STREET: 0 LF
1. A variance from the Zoning Ordinance to allow a reduced street buffer.
2. A variance to allow an increased sign height and total sign area.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
Nearly 50 years ago JA Riggs Tractor Company moved from Downtown Little
Rock and built a modern new facility on a site fronting a two-lane highway
outside the southwest edge of the City. As Little Rock grew this area was
annexed into the City, the two-lane highway became Interstate 30, and more
RECEIVED JUN
June 7, 2007
ITEM NO.: F (Cont.) FILE NO.: S-662-A
recently road and street modifications through and around the site has shrunk its
size from over 40 acres to 27 acres. It is now surrounded on all sides by roads,
the majority of them one way. These developments, coupled with aging facilities,
has led JA Riggs to develop a Master Plan for a phased redevelopment of the
site to be implemented over the next 20 years. The goals of the redevelopment
and changes proposed are:
GOALS FOR REDEVELOPMENT
PROPOSED CHANGES
■ Improve access to and from the site.
• Relocate primary customer access
point to University Avenue.
• Reorient all "customer -facing"
operations toward University
Avenue.
Replace and reposition all onsite
signage to direct traffic to new
entrance.
• Improve site security and safety.
• Customer access to equipment
yard limited to drop off and pickup
only. All other traffic diverted
around equipment yard.
e All access to equipment yard will be
via controlled access gates.
■ Employee access and parking
separated from customer access,
shipping and receiving, and
equipment yards.
• Improve building and site function
• Replace the majority of all existing
and appearance.
buildings over the next 20 years.
■ Expand and improve landscaping,
roads, parking and paving.
■ Use building to screen equipment
service storage areas where
possible.
• Maintain and improve operations
• Phase development to allow
during the rebuilding process.
buildings to be replaced with new,
operations relocated, and the old
ones demolished after that.
• Relocate operations on -site to
maintain or improve operational
efficiencies.
2
June 7, 2007
ITEM NO.: F (Cont.) FILE NO.: S-662-A
Phase One of the plan primarily consists of a single story tilt -up concrete parts
warehouse (52,350 square feet) with an attached two story office/retail sales
space (23,800 square feet) to be built on the east side of the site now used for
equipment display. A major relocation of site access and on -site circulation,
paving, parking and utilities will also occur during this phase. No existing
buildings will be removed during this phase.
Phase Two consists of one small wash bay/truck dyno building (6,800 square
feet) on the west side of the Phase One building. This would consist of a two-
story office addition (29,500 square feet) and a single story equipment shop
(23,550 square feet). At the end of this phase the existing main building that
houses existing parts warehouse and equipment service shop will be demolished
and replaced by employee and equipment service parking.
It is anticipated that the building(s) will be built of a combination of tilt -up
concrete, conventional steel framing, and pre-engineered metal building systems.
Exterior appearance of all buildings will be color coordinated to conform to
Caterpillar corporate identify requirements that consist of a light warm grey
overall color with red, black, or yellow accents. This will be accomplished by
using a combination of low maintenance materials consisting of pre -finished steel
panels, exterior coating systems, brick or tile.
The existing site consists of multiple tracts that were annexed into the City many
years ago many have never been rezoned to a classification that conforms to the
current or future anticipated use. Parallel to this site plan review process Riggs
is requesting a rezoning of the site to 1-2, Light Industrial District as a separate
item on this agenda (Z-3738-A)
The project as planned does not comply with the landscaped buffer ordinance.
The ordinance would typically require the placement of a 38-foot landscape
street buffer along the abutting roadways. The existing site conditions and the
planned development make it difficult for Riggs to comply with the ordinance
requirements.
The request, a key part of Riggs Master Plan, is the first of two phases of the
planned redevelopment. At minimum, Phase one will be implemented
immediately upon approval. Phase Two may be built at the same time
contingent on project costs. If not constructed immediately it is anticipated
Phase Two will be completed within five years.
The applicant is seeking a variance to allow an increased sign height and total
sign area. The signage proposed is a pole sign 60-feet in height and 100 square
feet in area.
3
June 7, 2007
ITEM NO.: F (Cont.) _ FILE NO.: S-662-A
B. EXISTING CONDITIONS:
The site contains a number of buildings currently being used by JA Riggs in their
equipment business. Along the southern boundary of the site is the Cloverdale
Ditch with a wooded area located south of the ditch. The front parking area is
paved and the service yard of the site is graveled.
To the east of the site, across University Avenue, is the Cloverdale Subdivision.
To the west of the site, across Chicot Road, are commercial uses including a gas
station, hotel and strip retail center. North of the site is 1-30. Chicot and South
University Avenue were recently reconstructed. There is not a sidewalk located
along Chicot Road.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received several informational phone calls from area
residents. The Cloverdale Neighborhood Association, Southwest Little Rock
United for Progress and all owners of property located within 200-feet of the site
were notified of the Public Hearing.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan. The
sidewalk should be completed along Chicot Road to the bridge.
2. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
3. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Herbner).
4. If disturbed area is one (1) or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
6. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
0
June 7, 2007
ITEM NO.: F Cont. FILE NO.: S-662-A
7. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
8. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25-foot
wide access easement is required adjacent to the floodway boundary.
9. Erosion controls must be installed to reduce discharge of polluted storm
water.
10. The minimum Finish Floor elevation is required to be shown on plat and
grading plans.
11. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer available to the property.
Entergy: No comment received.
Center -Point Energy: Approved as submitted.
AT & T: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. Additional on site fire
protection will be required. Contact Central Arkansas Water if larger and/or
additional water meter(s) are required.
Fire Department: Additional fire hydrants may be required. Contact the Little
Rock Fire Department for additional information.
County Planning:
CATA: The site is not located on a dedicated CATA Bus Route.
F. ISSUES/TECHNICAUDESIGN:
Planning Division: No comment.
Landscape:
1. Compliance with the City's Landscape and Buffer Ordinances is required.
2. The zoning buffer ordinance requires an average forty-three (43'-0") foot
wide street buffer along the access road. Currently, this site plan is not
5
June 7, 2007
ITEM NO.: F (Cont.
FILE NO.: S-662-A
meeting this minimum requirement. There should be no new development
of any kind in this area.
3. The zoning buffer ordinance requires an average forty-four foot (44'-0")
wide street buffer along Chicot Road. Currently, this site plan is not
meeting this minimum requirement. There should be no new development
of any kind in this area.
4. The landscape ordinance requires a minimum thirty foot wide (30'-0")
landscape strip along Interstate 30. Currently, this site plan is not meeting
this minimum requirement. A variance from this requirement must be
obtained by the City Beautiful Commission prior to the issuance of a
building permit.
5. The landscape ordinance requires a minimum nine foot wide landscape
strip around the sites perimeter. A variance from this minimum
requirement must be obtained by the City Beautiful Commission prior to
the issuance of a building permit.
6. The landscape ordinance requires a minimum of 8 % of the paved areas
be landscaped with interior islands of at least 7 %2 feet in width and 300
square feet in area. Proposed plan does not currently reflect this
minimum.
7. A small amount of building landscaping is also required.
8. Four foot can be taken off of the parking lot depth in 5 areas substantially
increasing the amount of overall green space on the site as well as
assisting in meeting the City's minimum landscape requirements.
9. An automatic irrigation system to water landscaped areas will be required.
10. Prior to the issuance of a building permit, it will be necessary to provide an
approved landscape plan stamped with the seal of a Registered
Landscape Architect.
11. The City Beautiful Commission recommends preserving as many existing
trees as feasible on this tree covered site. Credit toward fulfilling
Landscape Ordinance requirements can be given when preserving trees
of six (6) inch caliper or larger.
G. SUBDIVISION COMMITTEE COMMENT: (May 3, 2007)
The applicant was present representing the request. Staff presented an
overview of the proposed development stating the development was the first step
in implementation of the newly developing Master Plan for J.A. Riggs. Staff
stated the request included a variance to allow a reduced street buffer. Staff
stated all on -site areas would be paved with the exception of the equipment
storage area. Staff stated the time frame for completion of the two phases
proposed for development was two to five years.
M.
June 7, 2007
ITEM NO.: F (Cont.
FILE NO.: S-662-A
Public Works comments were addressed. Staff stated a 25-foot access
easement should be indicated on the proposed site plan adjacent to the drainage
structures. Staff also stated a sidewalk along Chicot Road was required to extend
from the current terminus to the southern boundary of the property. Staff also
stated a minimum finish floor elevation was required to be shown on the plat and
grading plans.
Landscape comments were addressed. Staff stated a nine foot minimum
landscape strip was required around the perimeter of the site and a 30-foot
minimum landscape strip was required along 1-30. Staff stated variances from
this minimum requirement would require approval from the City Beautiful
Commission. Staff noted the indicated site plan did not include the typically
required street buffers along University Avenue and Chicot Road.
Staff noted comments from the various other reporting departments and
agencies suggesting the applicant contact them directly for additional information
and clarification. There was no further discussion of the item. The Committee
then forwarded the item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised site plan to staff addressing most of the issues
raised at the May 3, 2007, Subdivision Committee meeting. The revised site plan
indicates the reduced street buffer along the abutting roadways. The revised
plan also indicates a 25-foot access easement along the floodway as required by
Section 31-176 of the Little Rock Code of Ordinances.
The applicant is seeking site plan approval for the implementation of a master
plan for the company. The site plan indicates the plan will be constructed in two
phases with the first phase beginning immediately upon approval and the second
phase being completed within five years.
The first phase consists of a single story parts warehouse (52,350 square feet)
with an attached two story office/retail sales space (23,800 square feet) to be
built on the east side of the site now used for equipment display. As a part of this
phase access to the site and on -site circulation, paving, parking and utilities will
occur. No existing buildings will be removed during this construction phase.
The second phase consists of one small wash bay/truck dyno building
(6,800 square feet) on the west side of the parts warehouse - office/retail sales
building. This building is proposed with a two-story office addition
(29,500 square feet) and a single story equipment shop (23,550 square feet). At
the end of this phase the existing main building that houses parts warehouse and
equipment service shop will be demolished and replaced by employee and
equipment service parking.
7
June 7, 2007
TEM NO.: F (Cont.
FILE NO.: S-662-A
The existing site consists of multiple tracts that were annexed into the City many
years ago many have never been rezoned to a classification that conforms to the
current or future anticipated use. As a separate item on this agenda (Z-3738-A)
the applicant is requesting a rezoning of the site from various zoning
classifications to 1-2, Light Industrial District.
As proposed the plan does not fully comply with the landscaped buffer ordinance.
The landscape ordinance requires a minimum nine foot wide landscape strip
around the site's perimeter. The site plan does meet this typical minimum
requirement. The zoning buffer ordinance typically requires a forty-three foot
wide average street buffer along the access road, a forty-four foot wide average
street buffer along Chicot Road and a thirty foot wide minimum landscape strip
along Interstate 30. Currently, this site plan is not meeting these minimum
requirements. The applicant will seek a variance from the City Beautiful
Commission to allow the reduced landscape strip along Interstate 30. Staff is
supportive of the variance request.
The applicant is seeking a variance to allow an increased sign height and total
sign area. The signage proposed is a pole sign 60-feet in height and 100 square
feet in area. The ordinance typically allows a maximum sign height of 30-feet
and a maximum sign area of 72-square feet. Staff is supportive of an increased
sign area and height but staff recommends the applicant be limited to a single
ground mounted sign along the Frontage Road (north perimeter) and the height
of the sign be measured as allowed in Section 36-557(b) of the Zoning
Ordinance. This section allows sign heights for all ground -mounted on -premise
signs located on properties immediately adjacent to and contiguous to an
expressway or freeway to be measured from the elevation of the centerline of the
traffic lanes (excluding frontage roads) adjacent to subject property to the top of
the sign structure. It shall be the responsibility of the sign owner to submit all
necessary information when this approach is used.
Staff is supportive of the proposed site plan review and the variances associated
with the request. The request is a key part of Riggs Master Plan and is the first
of two phases of the planned redevelopment. Staff does not feel the requested
variance to allow a reduced landscape strip along the abutting roadways or the
increased sign area and sign height will adversely impact the development or the
area, To staffs knowledge there are no outstanding issues associated with the
request.
STAFF RECOMMENDATIONS:
Staff recommends approval of the request subject to compliance with the
comments and conditions as outlined in paragraphs D, E and F of the agenda
staff report.
0
June 7, 2007
iTEM NO.: F Cont. FILE NO.: S-662-A
Staff recommends approval of the variance request to allow a reduced street
buffer along the abutting roadways.
Staff recommends approval of the variance request to allow an increased sign
area and increased sign height along the northern perimeter of the site. Staff
recommends the height be measured as allowed in Section 36-557(b) of the
zoning ordinance.
PLANNING COMMISSION ACTION: (MAY 24, 2007)
The applicant was present. There were no registered objectors present. The Chairman
explained to the applicant that when fewer than eight (8) Commissioners were present
the Commission routinely allowed the applicant to seek a deferral to a later public
hearing date to allow for additional Commissioner to be present when deciding the
applicant's request. The Chair stated one of the Commissioners present would be
recusing from the vote on this item which did not allow the required six votes to approve
the request. The Chair offered two dates for the deferral request one June 7, 2007, the
second July 5, 2007, and questioned the applicant as to which date they desired their
request to be heard. The applicant stated the June 7, 2007, public hearing date was
acceptable.
There was no further discussion of the item. The Chair entertained a motion for
placement of the item on the June 7, 2007, public hearing docket. A vote of 5 ayes,
0 noes, 4 absent, 1 recusal (Troy Laha) and 1 open position was registered.
STAFF UPDATE:
Staff indicated in the Analysis Section the applicant would be required to seek a
variance from the City Beautiful Commission concerning the allowance for a reduced
landscape strip along Interstate 30. This statement is incorrect. The applicant is
meeting the typical minimum requirements of the Landscape Ordinance and will not be
required to seek approval from the City Beautiful Commission. The applicant is seeking
a variance from the typical buffer ordinance requirements, which is approval by the
Commission, for a reduced landscape strip along the abutting roadways.
F—M
Area.
Vicinity Map
Lullill
Case: S-662-A
Location: 9125 Interstate 30 N
Ward: 7
PD: 15
CT: 41.03 0 500 1,000 Feet
TRS: T1NR13W36
i%
S-662-A*,1.q. RIGGS TRACTORS SUBDIVISION SITE PLAN REVIEW
June 7, 2007
ITEM NO.: H
NAME: J. A. Riggs Rezoning from R-2, C-3, C-4 and 1-2 to 1-2
LOCATION: Located at 9125 Interstate 30
DEVELOPER:
JA Riggs Tractor Company
9125 Interstate 30
Little Rock, AR 72209
ENGINEER:
McClelland Consulting Engineers, Inc.
P.O. Box 34087
Little Rock, AR 72203
ARCHITECT:
Combined Efforts design PLLC
201 South 20th Street, Suite 16
Rogers, AR 72758
AREA: 26.9 acres
CURRENT ZONING
PLANNING DISTRICT:
/ rk If I I TP A /1 _
NUMBER OF LOTS: 1
R-2, C-3, C-4 and 1-2
15 — Geyer Springs West
41.03
VARIANCESYWAIVERS REQUESTED: None requested.
SURROUNDING LAND USE AND ZONING
North — Interstate 30; zoned 1-2
South —Vacant; zoned C-3
East — South University Avenue — City Park; zoned PR
West — Motel and Gas Station; zoned C-3
FILE NO.: Z-3738-A
FT. NEW STREET: 0 LF
June 7, 2007
ITEM NO.: H (Cont.) FILE NO.: Z-3738-A
A. PUBLIC WORKS COMMENTS:
1. Sidewalks with appropriate handicap ramps are required in accordance with
Section 31-175 of the Little Rock Code and the Master Street Plan. The
sidewalk should be completed along Chicot Road to the bridge.
2. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
3. Plans of all work in right-of-way shall be submitted for approval prior to start
of work. Obtain barricade permit prior to doing any work in the right-of-way
from Traffic Engineering at (501) 379-1805 (Travis Herbner).
4. If disturbed area is one (1) or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior to the
start of construction.
5. A special Grading Permit for Flood Hazard Areas will be required per
Section 8-283 prior to construction.
6. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
7. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
8. In accordance with Section 31-176, floodway areas must be shown as
floodway easements or be dedicated to the public. In addition, a 25-foot
wide access easement is required adjacent to the floodway boundary.
9. Erosion controls must be installed to reduce discharge of polluted, storm
water.
10. The minimum Finish Floor elevation is required to be shown on plat and
grading plans.
11. Repair or replace any curb and gutter or sidewalk that is damaged in the
public right-of-way prior to occupancy.
B. PUBLIC TRANSPORTATION ELEMENT:
The site is not located on a dedicated CATA Bus Route.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has not received any comment from area residents. The
Cloverdale Neighborhood Association, Southwest Little Rock United for Progress
2
June 7, 2007
ITEM NO.: H (Cont.) FILE NO.: Z-3738-A
and all owners of property located within 200-feet of the site were notified of the
Public Hearing.
D. LAND USE ELEMENT:
Planning Division: This request is located in the Geyer Springs West Planning
District. The Land Use Plan shows Industrial for this property. The applicant has
applied for a multiple building site plan review of JA Riggs Master Plan to
improve access to and from the site and improve building and site function and
appearance and a rezoning from R-2, C-3 and C-4 to 1-2.
The request does not require a change to the Land Use Plan.
Master Street Plan: Chicot Road is shown as a Collector on the Master Street
Plan. The primary function of a Collector Street is to provide a connection from
Local Streets to Arterials.
Bicycle Plan: A Class III bike route is shown on Chicot Road. A Class III
bikeway is a signed route on a street shared with traffic. No additional paving or
right-of-way is required. Class III bicycle route signage may be required.
City Recognized Neighborhood Action Plan: The applicant's property lies in the
area covered by the Cloverdale Watson Neighborhood Action Plan. The Land
Use and Zoning goal states, "Encourage the use of Planned Zoning Districts for
business developments."
E. STAFF ANALYSIS:
J.A. Riggs owns approximately 27 acres located between Chicot Road, South
University Avenue and the 1-30 Frontage Road. The property is currently zoned
C-3, CA 1-2 and R-2 and J.A. Riggs is requesting to rezone the property to 1-2,
Light Industrial District. The rezoning is proposed to allow the development of
the property consistent with the company's overall master plan. The plan will be
developed in two phases with the anticipated time frame for completion of the
entire project within five years. J.A. Riggs Tractor is currently using the property
for business operation including parts warehouse, office, equipment storage and
equipment repair.
The site contains a number of buildings currently being used by JA Riggs in their
equipment business. Along the southern boundary of the site is the Cloverdale
Ditch with a wooded area located south of the ditch. The front parking area is
paved and the service yard of the site is graveled.
To the east of the site, across University Avenue, is the Cloverdale Subdivision.
To the west of the site, across Chicot Road, are commercial uses including a gas
station, hotel and strip retail center. North of the site is 1-30. Chicot and South
3
June 7, 2007
ITEM NO.: H (Cont.) FILE NO.: Z-3738-A
University Avenue were recently reconstructed. There is not a sidewalk located
along Chicot Road.
The City's Future Land Use Plan designates this property as "Industrial". A Land
Use Plan Amendment is not necessary for the rezoning of the site.
Staff is supportive of the proposed rezoning request. The property proposed for
rezoning is located within the boundary of Riggs property and indicated in the
Company's Overall Master Plan. Staff feels the proposed rezoning of the
property for J.A. Riggs facilities is appropriate and should have no adverse
impact on the surrounding properties and the general area.
F. STAFF RECOMMENDATIONS:
Staff recommends approval of the requested 1-2 rezoning.
PLANNING COMMISSION ACTION: (MAY 24, 2007)
The applicant was present. There were no registered objectors present. The Chairman
explained to the applicant that when fewer than eight (8) Commissioners were present
the Commission routinely allowed the applicant to seek a deferral to a later public
hearing date to allow for additional Commissioner to be present when deciding the
applicant's request. The Chair stated one of the Commissioners present would be
recusing from the vote on this item which did not allow the required six votes to approve
the request. The Chair offered two dates for the deferral request one June 7, 2007, the
second July 5, 2007, and questioned the applicant as to which date they desired their
request to be heard. The applicant stated the June 7, 2007, public hearing date was
acceptable.
There was no further discussion of the item. The Chair entertained a motion for
placement of the item on the June 7, 2007, public hearing docket. A vote of 5 ayes,
0 noes, 4 absent, 1 recusal (Troy Laha) and 1 open position was registered.
rd