Loading...
HomeMy WebLinkAboutS-0467-A Staff AnalysisJuly 9, 1985 SUBDIVISIONS Item No. 8 NAME: Kavanaugh Place "Short -Form PCD" (Z-4473) LOCATION: Southwest Corner of Kavanaugh Boulevard and Ash Street DEVELOPER: ENGINEER: McClelland Dev. Corp. Lewis Engineering 2207 Hidden Valley Dr. 367 I-30 Suite 204 Alexander, AR 72202 Little Rock, AR 72212 Phone: 847-4630 Phone: 225-5569 AREA: .4863 acres NO. OF 40TS: 3 FT. ,NEW ST.: None ZONING: "C-4" (Dots 1 and 2 "R-2" (Lot 3) PROPOSED USE: Mixed Use Office and Retail A. Development Objectives (1) .To provide a development in which location, character and tenant mix will provide the Hillcrest area with desirable retail and office space, while contributing to the visual aesthetics of the community and function of the commercial district. (2) To repeat established patterns in the Heights/Hillcrest area, such as: (a) The crescent shape of the building, which relates to the old trolley turn around the station; (b) The street front pedestrian shopping pattern that is prominent in the area; (c) The similar architectural character (clay tile awning) of the building occupied by The Afterthought will be carried through on the corner building. } 9, 1985 T, yulY SUBDIVISIONS Item No. 8 - Continued B. Proposal (1) To provide a mixed used office/retail development on .4 acres and to replat three lots into a single site. (2) Project Information (a) Building Blueprint ........... 9,530 sq. ft. Building/Land Ratio .......... 45 percent Buildings Corner Bldg. ....... 1st Floor 578 2nd Floor .... 540 Main Bldg. ....... 1st Floor 7,789 2nd Floor .... 8,109 Totai 7,016 net leasable 10 Leasable Units Proposed (b) Parking: 22 cars on -site - 1 car per 773 sq. ft. (c)- Site Improvements Include: i. Landscaping strip along south property line to visually separate parking from the adjacent residential area. -ii. Trees along the east sidewalk to enhance the project and lessen the impact of the Hillcrest Cleaners'. A iii. Sidewalks will be concrete with brick paver • accents. (3) Developmental Time Frame: August 6, 1985 - "PUD" Granted Sept. 6, 1985 - Break Ground for Construction Feb. 6, 1986 - Construction Completed C. Engineerinq Comments (1) A landscaped strip is required adjacent to parking on Ash Street. El July 9, 1985 SUBDIVISIONS Item No. 8 - Continued (2) There is sufficient parking area on the south of the projects for head -in parking if desired. (3) Clarify building at the corner of Kavanaugh and Ash Street - blind corner problem may exist. (4) Recommend dumpster be located at an angle to the alley. D. Analysis The applicant has submitted a project that he describes as being "strategically located at a 'bend in the road' on Kavanaugh," and is by its physical layout, at the visual terminus of the entire commercial district to -the west. Therefore, the building creates a visual backdrop for shoppers in the area drawing them through the shopping district, to "Kavanaugh Place" and beyond. He points out also that the area is located in the Neighborhood Commercial Revitalization Area of the Heights/Hillcrest District Plan of 1981. He has also designed the project to open up to the corner, to maximize visibility for retail and drive -up parking. Staff recognizes and appreciates the applicant's desire to revitalize this area. Parking, however, is a - definite problem. Only 22 spaces are provided. The applicant offers an estimate of approximately 50 addtional off -site spots available within one block,. considering the local restaurant and business hours each project will operate. He is asked to clarify this statement. Staff has other concerns. First of all, the applicant sho.'ld.identify each building on his site plan. Fie is asked to clarify what appears to be the corner building, it may create a problem for traffic. Also, the 4' screen proposed is insufficient; it should be at least 61. E. Staff Recommendation Staff defers recommendation until above issues are resolved. . i July 9, 1985 SUBDIVISIONS Item No. 8 - Continued SUBDIVISION COMMITTEE REVIEW: Ms. Cynthia Alderman represented the developer. A revised plan was submitted which reduced the square footage to 12,894, provided 39 parking spaces and a 6-foot fence. The main issued discussed the corner building and a possible blind corner. The applicant was asked to meet with Engineering before the public hearing to resolve the issue. Water Works - An 8 inch water main extension from Woodlawn will be required if the building is to have fire service. if