HomeMy WebLinkAboutS-0046-AA Staff AnalysisFILE NO.: S-46-AA
NAME: Overlook Park Revised Preliminary Plat
LOCATION: Located South of Overlook Drive, at the end of Woodglen Road
DEVELOPER:
Pfeifer Development Company
P.O. Box 99
N. Little Rock, AR 72115
ENGINEER:
White-Daters and Associates
#24 Rahling Circle
Little Rock, AR 72223
AREA: 38 acres
CURRENT ZONING:
PLANNING DISTRICT:
CENSUS TRACT:
NUMBER OF LOTS: 35
R-2, Single-family
FT. NEW STREET: 3600 LF
3 —West Little Rock Planning District
22.01
VARIANCESMAIVERS REQUESTED:
1. A variance to allow Woodglen Drive to be constructed to a minor residential
street standard, including a variance to allow a 50-foot centerline radius in two
locations and a variance to allow 18% grades in several locations.
2. A variance to allow double frontage lots for Lots 166-173.
3. A variance to allow a reduced front building line (15-feet) for Lots 152-164.
A. PROPOSAUREQUEST:
A preliminary plat was approved for the proposed subdivision in the Mid-1960's.
The approved preliminary plat included the development of this 38 acres with
39 single-family lots. The lots were proposed as rear loaded lots and the lots
were to be developed with a minor residential street standard and no sidewalk.
The lots were never developed and the developer is proposing to reconfigure the
existing preliminary plat to reduce the number of lots and eliminate the private
drive access with the exception of the drive on the east side. The current layout
proposes 35 lots. The developer has indicated Woodglen Drive is partially
FILE NO.: S-46-AA (Cont.
constructed to a minor residential standard. The property contains challenging
slopes and requires the development standards outlined under the minor
residential street requirement to function properly. Specifically, the developers
will need a centerline radius of 50-feet in two locations, 18 percent grades in
several locations and no sidewalks on this portion of the street. The applicant
has indicated Woodglen does not have sidewalks on the existing section of the
street.
The applicant has indicated in their opinion the eliminating of the rear access will
be more compatible with the existing neighbors and will eliminate the need to
clear trees adjacent to their backyards. The applicant has indicated they believe
the adjoining property owners will be pleased with fewer lots and no alleys.
B. EXISTING CONDITIONS:
The lots are extremely steep falling from the road with topography ranging in
elevation from 475-feet to 525-feet. Single-family homes have developed in -the
area in similar conditions. The site is wooded with a ravine running along the
south and west. Foxcroft has developed to the south of the site across the
ravine. Single-family homes are located north of the site in the Overlook
Subdivision.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received one informational phone call from an area
resident. All property owners abutting the site along with the Robinwood and
Overlook Property Owners Associations were notified of the Public Hearing.
D. ENGINEERING COMMENTS:
Public Works Conditions:
1. With site development, provide design of street conforming to the Master
Street Plan.
2. Street names and street naming conventions must be approved by Public
Works. Contact David Hathcock at (501) 371-4808.
3. Due to elevation changes and street curvature, proposed street should be
one (1) way. Reconfigure intersection for no left turns from existing
entrance into subdivision.
4. A Sketch Grading and Drainage Plan with street design will be required per
Section 29-186 (e). Show compliance with City of Little Rock street
standards specifically pertaining to horizontal radius of 75 ft and maximum
centerline grade of 16%. Up to 18% centerline grade can be approved in
special situation.
5. On site striping and signage plans should be forwarded to Public Works,
Traffic Engineering for approval prior to construction.
6. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock code. Contact Traffic Engineering at
2
FILE NO.: S-46-AA (Cont.
E.
F
(501) 379-1813 (Steve Philpott) for more information regarding street light
requirements.
7. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
8. Historically, unusual soil conditions involving springs have existed in this
area. All construction should account for these conditions.
9. The proposed right-of-way dedication meets Master Street Plan
requirements.
10. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
11. Easements are required for all storm water drainage areas.
12. Obtain a NPDES storm water permit from the Arkansas Department of
Environmental Quality prior to the start of construction.
13. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements, if service is
required for the project. Contact Little Rock Wastewater Utility at 688-1414 for
additional information.
Enter : No comment received.
Center -Point Energy: No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A water main extension will be
required in order to provide service to this property. This development will have
minor impact on the existing water distribution system. Proposed water facilities
will be sized to provide adequate pressure and fire protection.
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3700 for additional information.
County_Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
ISSUESTFECHNICAL/DESIGN:
Planning Division: No comment.
Landscape: No comment.
3
NO.: S-46-AA (Cont.
G. SUBDIVISION COMMITTEE COMMENT: (October 20, 2005)
Mr. Joe White of White Daters and Associates was present representing the
request. Staff presented an overview of the proposed development indicating
there were additional items necessary to complete the review process. Staff
requested the applicant provide the names and address of the landowner along
with the source of title in the general notes section of the proposed preliminary
plat. Staff also requested the applicant provide the average size of the lots and
the minimum lot size in the general notes section of the proposed preliminary
plat.
Public Works comments were addressed. Staff noted the street names and
street naming conventions would need to be approved by Public Works prior to
final platting. Staff also stated due, to the elevation changes and street
curvature, the proposed street should be one way, reconfiguring intersections for
no left turns from existing entrances into the subdivision. Mr. White questioned
this comment. He stated the proposed street design was very similar to the
existing development pattern in the area. Staff stated with the requested
curvatures, traffic circulation in the area would not be safe. Mr. White stated he
would meet with Public Works staff to discuss this request in greater details.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised preliminary plat to staff addressing most of the
issues raised at the October 20, 2005, Subdivision Committee meeting. The
applicant has indicated the name and address of the landowner along with the
source of title for the landowner in the general notes section of the proposed
preliminary plat. The applicant has also indicated the average size (140-feet by
275-feet) of the lots and the minimum lot size (145-feet by 250-feet) in the
general notes section of the proposed preliminary plat. The applicant has
indicated prior to final platting the developer will contact Public Works staff to
confirm the proposed street names within the proposed subdivision.
The applicant has met with Public Works staff concerning the request to one-way
the proposed street serving the indicated lots. Staff feels the developers should
increase the radius of the two curves proposed within the subdivision or one-way
the proposed street. Staff feels the curb radius should be increased to 75-foot
radius to allow sufficient pavement for motorist to travel. Staff also feels these
two curve areas should be signed for no parking to increase the visibility.
The applicant is requesting a variance to allow Woodglen Drive to be constructed
to a minor residential street standard. Staff is supportive of this variance request.
FILE NO.: S-46-AA (Cont.
Typically a minor residential street is limited to 1500 linear feet and serving no
more than 35 lots. Although, the street exceeds the maximum length typically
allowed, the number of lots is consistent with the proposed street design.
The applicant is requesting a variance to allow double frontage lots for Lots 166 —
173. Staff is supportive of this request. The lots have a depth which will allow for
building setbacks sufficient to allow developable area for the new homes. Staff
does not feel a street adjacent to the front and rear of the homes will have a
significant impact of the potential development.
The applicant is requesting a variance to allow a 15-foot building line on
proposed Lots 152 — 164. The applicant has indicated the steepness of the lots
does not lend itself to development with the traditional 25-foot building line. The
subdivision Ordinance typically allows lots with a 18 percent slope or greater to
be developed with reduced design standards. The applicant has indicated
several areas have steep slopes, which would typically allow special subdivision
development standards. Staff is supportive of the applicant's request. The
applicant has indicated reduced front building lines in areas abutting existing
single-family neighborhoods. The reduced front building line will allow for the
development of the proposed lots with minimal disturbance to the existing
vegetation in the area.
Staff is supportive of the proposed preliminary plat with the exception as noted
above concerning the radius of the proposed roadway. As indicated, staff feels
the radius should be a 75-foot minimal to allow for sufficient sight distance and
maneuvering. The applicant is proposing the subdivision of this 38 acre tract into
35 single-family lots resulting in a density of 1.08 units per acre. The proposed
preliminary plat removes the rear drives along the Overlook side of the
development. The Foxcroft side of the development remains virtually the same.
Staff feels the subdivision of this site and the development of thirty-five new
single-family homes is an appropriate use of this property.
I. STAFF RECOMMENDATION:
Staff recommends approval of the proposed preliminary plat subject to
compliance with the conditions and comments outlined in paragraphs D, E, F and
H of the above agenda staff report.
Staff recommends approval of the requested variance to allow Woodglen Drive to
be constructed to a minor residential street standard. Staff is supportive of the
requested variance to allow 18% grades in several locations.
Staff recommends approval of the requested variance to allow double frontage
lots for Lots 166-173.
Staff recommends approval of the requested variance to allow a reduced front
building line (15-feet) for Lots 152-164.
5
ICI I IQUGM�-I- . _1_w(e:Titi
PLANNING COMMISSION ACTION: (NOVEMBER 10, 2005)
Mr. Joe White of White-Daters and Associates was present representing the request.
There were registered objectors present. Staff presented the item with a
recommendation of approval of the proposed preliminary plat subject to compliance with
the conditions and comments outlined in paragraphs D, E, F and H of the agenda staff
report. Staff also presented a recommendation of approval of the requested variance to
allow Woodglen Drive to be constructed to a minor residential street standard and the
requested variance to allow 18% grades in several locations. Staff presented a
recommendation of approval of the requested variances to allow reduced lot
development standards limited to the requested variance to allow double frontage lots
for Lots 166-173 and the requested variance to allow a reduced front building line
(15-feet) for Lots 152-164.
Dr. Whit Goodwin addressed the Commission in opposition of the proposed subdivision.
He stated his home was located at 22 Tallyho Lane. He stated his concerns were with
drainage, the grade of the site and property values. He questioned the number of trees
that were to be cut for the proposed development. He stated the development would
drain to Jamison Creek as did the entire area. He stated with the development of lots
on the site there would be less area for absorption and questioned the ability of the
creek to handle the drainage.
Mr. Joe White of White-Daters and Associates addressed the Commission on the merits
of the request. He stated the development would pay the City an in -lieu contribution for
the required drainage. He stated based on the location of the development, near the
Arkansas River, the in -lieu would benefit the City more than a detention basin. He
stated with the construction of a detention basin additional trees would need to be
removed from the site.
Staff stated they felt the in -lieu more beneficial than actual construction. Staff stated the
in -lieu contribution would be held in an account and used for drainage improvements
within the watershed.
There was a question concerning the proposed grades and the construction of the
proposed street to a minor residential standard. Staff stated the grades were necessary
in two locations at hairpin turns. Staff stated they were supportive of the proposed
grades and the construction of the street to minor residential street standard including
the minor residential street radius for curves.
There was a general discussion concerning the proposed subdivision and the proposed
detention, cutting of trees and the proposed roadway construction. Staff stated prior to
construction the developer would be required to submit construction plans for the
development of the proposed subdivision. Staff stated the subdivision would be
inspected through the process to ensure the developers were complying with City
ordinances.
A
FILE NO.: S-46-AA Cont.
There was no further discussion of the item. The Chair entertained a motion for
approval. The motion carried by a vote of 9 ayes, 0 noes and 2 absent.
7
November 10, 2005
ITEM NO.: 3 FILE NO.: S-46-AA
NAME: Overlook Park Revised Preliminary Plat
LOCATION: Located South of Overlook Drive, at the end of Woodglen Road
DEVELOPER:
Pfeifer Development Company
P.O. Box 99
N. Little Rock, AR 72115
ENGINEER:
White-Daters and Associates
#24 Rahling Circle
Little Rock, AR 72223
AREA: 38 acres NUMBER OF LOTS: 35 FT. NEW STREET: 3600 LF
CURRENT ZONING: R-2, Single-family
PLANNING DISTRICT: 3 — West Little Rock Planning District
CENSUS TRACT: 22.01
VARIANCES/WAIVERS REQUESTED:
1. A variance to allow Woodglen Drive to be constructed to a minor residential
street standard, including a variance to allow a 50-foot centerline radius in two
locations and a variance to allow 18% grades in several locations.
2. A variance to allow double frontage lots for Lots 166-173.
3. A variance to allow a reduced front building line (15-feet) for Lots 152-164.
A. PROPOSAUREQUEST:
A preliminary plat was approved for the proposed subdivision in the Mid-1960's.
The approved preliminary plat included the development of this 38 acres with
39 single-family lots. The lots were proposed as rear loaded lots and the lots
were to be developed with a minor residential street standard and no sidewalk.
The lots were never developed and the developer is proposing to reconfigure the
existing preliminary plat to reduce the number of lots and eliminate the private
drive access with the exception of the drive on the east side. The current layout
November 10, 2005
SUBDIVISION
ITEM NO.: 3 (Cont.) FILE NO.: S-46-AA
proposes 35 lots. The developer has indicated Woodglen Drive is partially
constructed to a minor residential standard. The property contains challenging
slopes and requires the development standards outlined under the minor
residential street requirement to function properly. Specifically, the developers
will need a centerline radius of 50-feet in two locations, 18 percent grades in
several locations and no sidewalks on this portion of the street. The applicant
has indicated Woodglen does not have sidewalks on the existing section of the
street.
The applicant has indicated in their opinion the eliminating of the rear access will
be more compatible with the existing neighbors and will eliminate the need to
clear trees adjacent to their backyards. The applicant has indicated they believe
the adjoining property owners will be pleased with fewer lots and no alleys.
B. EXISTING CONDITIONS:
The lots are extremely steep falling from the road with topography ranging in
elevation from 475-feet to 525-feet. Single-family homes have developed in the
area in similar conditions. The site is wooded with a ravine running along the
south and west. Foxcroft has developed to the south of the site across the
ravine. Single-family homes are located north of the site in the Overlook
Subdivision.
C. NEIGHBORHOOD COMMENTS:
As of this writing, staff has received one informational phone call from an area
resident. All property owners abutting the site along with the Robinwood and
Overlook Property Owners Associations were notified of the Public Hearing.
D. ENGINEERING COMMENTS:
Public Works Conditions:
1. With site development, provide design of street conforming to the Master
Street Plan.
2. Street names and street naming conventions must be approved by Public
Works. Contact David Hathcock at (501) 371-4808.
3. Due to elevation changes and street curvature, proposed street should be
one (1) way. Reconfigure intersection for no left turns from existing
entrance into subdivision.
4. A Sketch Grading and Drainage Plan with street design will be required per
Section 29-186 (e). Show compliance with City of Little Rock street
standards specifically pertaining to horizontal radius of 75 ft and maximum
centerline grade of 16%. Up to 18% centerline grade can be approved in
special situation.
5. On site striping and signage plans should be forwarded to Public Works,
Traffic Engineering for approval prior to construction.
2
November 10, 2005
SUBDIVISION
ITEM NO.: 3 Cont. FILE NO.: S-46-AA
6. Prepare a letter of pending development addressing streetlights as required
by Section 31-403 of the Little Rock code. Contact Traffic Engineering at
(501) 379-1813 (Steve Philpott) for more information regarding street light
requirements.
7. Storm water detention ordinance applies to this property. Show the
proposed location for storm water detention facilities on the plan.
8. Historically, unusual soil conditions involving springs have existed in this
area. All construction should account for these conditions.
9. The proposed right-of-way dedication meets Master Street Plan
requirements.
10. A grading permit in accordance with Section 29-186 (c) and (d) will be
required prior to any land clearing or grading activities at the site. Site
grading, and drainage plans will need to be submitted and approved prior to
the start of construction.
11. Easements are required for all storm water drainage areas.
12. Obtain a NPDES storm water permit from the Arkansas Department of
Environmental Quality prior to the start of construction.
13. Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
E. UTILITIES AND FIRE DEPARTMENT/COUNTY PLANNING:
Wastewater: Sewer main extension required with easements, if service is
required for the project. Contact Little Rock Wastewater Utility at 688-1414 for
additional information.
Entergy: No comment received.
Center -Point Energy: No comment received.
SBC: No comment received.
Central Arkansas Water: All Central Arkansas Water requirements in effect at
the time of request for water service must be met. A water main extension will be
required in order to provide service to this property. This development will have
minor impact on the existing water distribution system. Proposed water facilities
will be sized to provide adequate pressure and fire protection.
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3700 for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
3
November 10, 2005
SUBDIVISION
ITEM NO.: 3 Cont. FILE NO.: S-45-AA
F. I SS U ESITEC H N 1 CAUD ES I G N:
Planning Division: No comment.
Landscape: No comment.
G. SUBDIVISION COMMITTEE COMMENT: (October 20, 2005)
Mr. Joe White of White Daters and Associates was present representing the
request. Staff presented an overview of the proposed development indicating
there were additional items necessary to complete the review process. Staff
requested the applicant provide the names and address of the landowner along
with the source of title in the general notes section of the proposed preliminary
plat. Staff also requested the applicant provide the average size of the lots and
the minimum lot size in the general notes section of the proposed preliminary
plat.
Public Works comments were addressed. Staff noted the street names and
street naming conventions would need to be approved by Public Works prior to
final platting. Staff also stated due, to the elevation changes and street
curvature, the proposed street should be one way, reconfiguring intersections for
no left turns from existing entrances into the subdivision. Mr. White questioned
this comment. He stated the proposed street design was very similar to the
existing development pattern in the area. Staff stated with the, requested -
curvatures, traffic circulation in the area would not be safe. Mr. White stated he
would meet with Public Works staff to discuss this request in greater details.
Staff noted comments from the other reporting departments and agencies
suggesting the applicant contact them individually for additional clarification.
There was no further discussion of the item. The Committee then forwarded the
item to the full Commission for final action.
H. ANALYSIS:
The applicant submitted a revised preliminary plat to staff addressing most of the
issues raised at the October 20, 2005, Subdivision Committee meeting. The
applicant has indicated the name and address of the landowner along with the
source of title for the landowner in the general notes section of the proposed
preliminary plat. The applicant has also indicated the average size (140-feet by
275-feet) of the lots and the minimum lot size (145-feet by 250-feet) in the
general notes section of the proposed preliminary plat. The applicant has
indicated prior to final platting the developer will contact Public Works staff to
confirm the proposed street names within the proposed subdivision.
0
November 10, 2005
SUBDIVISIO
ITEM NO.: 3 {Cant.
FILE NO.: S-46-AA
The applicant has met with Public Works staff concerning the request to one-way
the proposed street serving the indicated lots. Staff feels the developers should
increase the radius of the two curves proposed within the subdivision or one-way
the proposed street. Staff feels the curb radius should be increased to 75-foot
radius to allow sufficient pavement for motorist to travel. Staff also feels these
two curve areas should be signed for no parking to increase the visibility.
The applicant is requesting a variance to allow Woodglen Drive to be constructed
to a minor residential street standard. Staff is supportive of this variance request.
Typically a minor residential street is limited to 1500 linear feet and serving no
more than 35 lots. Although, the street exceeds the maximum length typically
allowed, the number of lots is consistent with the proposed street design.
The applicant is requesting a variance to allow double frontage lots for Lots 166 —
173. Staff is supportive of this request. The lots have a depth which will allow for
building setbacks sufficient to allow developable area for the new homes. Staff
does not feel a street adjacent to the front and rear of the homes will have a
significant impact of the potential development.
The applicant is requesting a variance to allow a 15-foot building line on
proposed Lots 152 — 164. The applicant has indicated the steepness of the lots
does not lend itself to development with the traditional 25-foot building line. The
subdivision Ordinance typically allows lots with a 18 percent slope or greater to
be developed with reduced design standards. The applicant has indicated
several areas have steep slopes, which would typically allow special subdivision
development standards. Staff is supportive of the applicant's request. The
applicant has indicated reduced front building lines in areas abutting existing
single-family neighborhoods. The reduced front building line will allow for the
development of the proposed lots with minimal disturbance to the existing
vegetation in the area.
Staff is supportive of the proposed preliminary plat with the exception as noted
above concerning the radius of the proposed roadway. As indicated, staff feels
the radius should be a 75-foot minimal to allow for sufficient sight distance and
maneuvering. The applicant is proposing the subdivision of this 38 acre tract into
35 single-family lots resulting in a density of 1.08 units per acre. The proposed
preliminary plat removes the rear drives along the Overlook side of the
development. The Foxcroft side of the development remains virtually the same.
Staff feels the subdivision of this site and the development of thirty-five new
single-family homes is an appropriate use of this property.
5
November 10, 2005
SUBDIVISIO
ITEM NO.: 3 (Cont.) FILE NO.: S-46-AA
STAFF RECOMMENDATION:
Staff recommends approval of the proposed preliminary plat subject to
compliance with the conditions and comments outlined in paragraphs D, E, F and
H of the above agenda staff report.
Staff recommends approval of the requested variance to allow Woodglen Drive to
be constructed to a minor residential street standard. Staff is supportive of the
requested variance to allow 18% grades in several locations.
Staff recommends approval of the requested variance to allow double frontage
lots for Lots 166-173.
Staff recommends approval of the requested variance to allow a reduced front
building line (15-feet) for Lots 152-164.
PLANNING COMMISSION ACTION: (NOVEMBER 10, 2005)
Mr. Joe White of White-Daters and Associates was present representing the request.
There were registered objectors present. Staff presented the item with a
recommendation of approval of the proposed preliminary plat subject to compliance with
the conditions and comments outlined in paragraphs D, E, F and H of the agenda staff
report. Staff also presented a recommendation of approval of the requested variance to
allow Woodglen Drive to be constructed to a minor residential street standard and the
requested variance to allow 18% grades in several locations. Staff presented a
recommendation of approval of the requested variances to allow reduced lot
development standards limited to the requested variance to allow double frontage lots
for Lots 166-173 and the requested variance to allow a reduced front building line
(15-feet) for Lots 152-164.
Dr. Whit Goodwin addressed the Commission in opposition of the proposed subdivision.
He stated his home was located at 22 Tallyho Lane. He stated his concerns were with
drainage, the grade of the site and property values. He questioned the number of trees
that were to be cut for the proposed development. He stated the development would
drain to Jamison Creek as did the entire area. He stated with the development of lots
on the site there would be less area for absorption and questioned the ability of the
creek to handle the drainage.
Mr. Joe White of White-Daters and Associates addressed the Commission on the merits
of the request. He stated the development would pay the City an in -lieu contribution for
the required drainage. He stated based on the location of the development, near the
Arkansas River, the in -lieu would benefit the City more than a detention basin. He
stated with the construction of a detention basin additional trees would need to be
removed from the site.
0
November 10, 2005
SUBDIVISION
ITEM NO.: 3 Cont. FILE NO.: S-46-AA
Staff stated they felt the in -lieu more beneficial than actual construction. Staff stated the
in -lieu contribution would be held in an account and used for drainage improvements
within the watershed.
There was a question concerning the proposed grades and the construction of the
proposed street to a minor residential standard. Staff stated the grades were necessary
in two locations at hairpin turns. Staff stated they were supportive of the proposed
grades and the construction of the street to minor residential street standard including
the minor residential street radius for curves.
There was a general discussion concerning the proposed subdivision and the proposed
detention, cutting of trees and the proposed roadway construction. Staff stated prior to
construction the developer would be required to submit construction plans for the
development of the proposed subdivision. Staff stated the subdivision would be
inspected through the process to ensure the developers were complying with City
ordinances.
There was no further discussion of the item. The Chair entertained a motion for
approval. The motion carried by a vote of 9 ayes, 0 noes and 2 absent.
7
js�
Z
ITEM NO.: 3.
NAME: Overlook Park Revised Preliminary Plat
FILE NO.: S-46-AA
LOCATION: located South of Overlook Drive, at the end of Woodglen Road v\A*
Planning Staff Comments-° '�
0
7
Provide notification of abutting property owners of the site, complete with the
certified abstract list, notice form with affidavit executed and proof of mailing.
Provide the names and address of the landowner along with the source of title in
the general notes section of the proposed preliminary plat.
Provide the linear feet of internal street in the general notes section of the
proposed preliminary plat.
Provide the average size of the lots and the minimum lot size of the lots in the
general notes section of the proposed preliminary plat.
Provide the total number of lots within this phase of the proposed preliminary plat
in the general notes section of the proposed preliminary plat.
Provide the source of water and the means of wastewater disposal in the general
notes section of the proposed preliminary plat.
Provide a preliminary storm drainage analysis and a preliminary storm drainage
plan.
Provide the names of any landlocked parcels within or abutting the plat area.
Provide a phasing plan, if applicable for the proposed preliminary plat area.
Variance/Waivers:
1. A variance to allow Woodglen Drive to be constructed to a minor residential
street standard, including a variance to allow a 50-foot centerline radius in two
locations and a variance to allow 18% grades in several locations.
2. A waiver of the Master Street Plan requirement for the placement of sidewalks.
3. A variance to allow double frontage lots for Lots 166-173.
4. A variance to allow a reduced front building line (15-feet)for Lots 152-164.
Public Works Conditions:
1 With site development, provide design of street conforming to the Master Street
Plan.
2 Street names and street naming conventions must be approved by Public
Works. Contact David Hathcock at (501) 371-4808.
3 Due to elevation changes and street curvature, proposed street should be one
(1) way. Reconfigure intersection for no left turns from existing entrance into
subdivision.
4 A Sketch Grading and Drainage Plan with street design will be required per Sec.
29-186 (e). Show compliance with City of Little Rock street standards
specifically pertaining to horizontal radius of 75 ft and maximum centerline grade
of 16%. Up to 18% centerline grade can be approved in special situation.
5 On site striping and signage plans should be forwarded to Public Works, Traffic
Engineering for approval prior to construction.
6 Prepare a letter of pending development addressing streetlights as required by
Section 31-403 of the Little Rock code. Contact Traffic Engineering at (501) 379-
1813 (Steve Philpott) for more information regarding street light requirements.
7 Storm water detention ordinance applies to this property. Show the proposed
location for storm water detention facilities on the plan.
8 Historically, unusual soil conditions involving springs have existed in this area.
All construction should account for these conditions.
9 The proposed right-of-way dedication meets Master Street Plan requirements.
10 A grading permit in accordance with Section 29-186 (c) and (d) will be required
prior to any land clearing or grading activities at the site. Site grading, and
drainage plans will need to be submitted and approved prior to the start of
construction.
11 Easements are required for all storm water drainage areas.
12 Obtain a NPDES storm water permit from the Arkansas Department of
Environmental Quality prior to the start of construction.
13 Street improvement plans shall include signage and striping. Traffic
Engineering must approve completed plans prior to construction.
Utilities and Fire Department/County Planning:
Wastewater: Sewer main extension required with easements, if service is required
for the project. Contact Little Rock Wastewater Utility at 688-1414 for additional
information.
Entergy:
Center -Point Ener :
SBC:
Central Arkansas Water: All Central Arkansas Water requirements in effect at the
time of request for water service must be met. A water main extension will be
required in order to provide service to this property. This development will have
minor impact on the existing water distribution system. Proposed water facilities will
be sized to provide adequate pressure and fire protection.
Fire Department: Place fire hydrants per code. Contact the Little Rock Fire
Department at 918-3700 for additional information.
County Planning: No comment.
CATA: The site is not located on a dedicated CATA Bus Route.
Plannina Division: No comment.
Landscape: No comment.
Revised pIat/plan: Submit four (4) copies of a revised preliminary plan (to
include the additional information as noted above) to staff on Wednesday, October
26, 2005.