Loading...
HomeMy WebLinkAboutZ-7500-F Map 4\\ \ * \ \\ \\ \\ GRAPHIC SCALE IN FEET PROJECT \\\ FENCE ENDS �ss \\ \\\ \\ 40' 0 40' LOCATION L411 \\\ \ I \ i %�%% N, I , 12 ��� vv� v `�>> // vv VICINITY MAP ETAINING / I i1 i� \'\� / 6,' / S6� ' — `. ■_ f WALL I 11 1 ��- 00 \ to \ N \ wl \ of N d- O Z I I IGARAGE (TYP.) CANOPY - (TYP.) 41' SWING GATE 6'JECORATIVE TAL FENCE SAXl TA EASIEVE 60' M N L ACCESS AND TURNAROUND EASEMENT lJ+ 2 1C 67 ACRES+ v v�v O vv o /i � CHAIN LINK \ C/ FENCE W/GATE S i� O 8 \ GARDEN FENCE ENDS GARAGE \ n� ,< / vvSv(Zyp•) vvmoo �. LLJ W Lt A N I 19.15' v� 414.65I Y �. / 21.88'a I i i 1 6 v ", 0 \ ` I I \ �I �� // 24.21, I 60 �,IIm ®rImIu;!; •• •• iuui 0 PROJECT DATA APARTMENTS 248 PARKING SPACES: 442 (22 - UNDER BUUILDING, 36 - IN GARAGES, 206 - COVERED, 178 - OPEN) STANDARD 433 ACCESSIBLE 9 PARKING SPACES/UNIT 1.78 SITE 10.67 ACRES (100% ) BUILDING 98,925 SF (21.2% ) IMPERVIOUS AREA 6.0 ACRES (56.3% ) GREEN SPACE 4.67 ACRES (43.7% ) 60' 6' DECORATIVE - METAL FENCE o. SITE NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIIMITED TO, SEGMENTAL RETAINING WALLS MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. 2. ALL WORK AND MATERIALS SHALL COMPLY WITH ALL CITY/COUNTY/STATE/FEDERAL REGULATIONS AND CODES AND OSHA STANDARDS 3. CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT UTILITY ENTRANCE LOCATIONS 4. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED. 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 6. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE. 7. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. 8. CONTRACTOR SHALL MATCH NEW CURB AND GUTTER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. 9. CONTRACTOR SHALL MAINTAIN ALL EXISTING PARKING, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVITY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC TO AND FROM THE SITE T \ \ \,OWN \� FIL DWAY \ v ACCESS - .EASEMENT EMERGENCY EXIT GATE W/KNOXBOX . LEGEND (EXISTING SYMBOLS) SYMBOLS LINEWORK 0 FOUND IRON PIN EASEMENT LIGHT POLE --- ---- --- - ---- - --- ---- --------- 'R POWER POLE CURB IM TELEPHONE PEDESTAL -- - - ---- - -- - N TV PEDESTAL INTERMEDIATE CONTOUR O MANHOLE INDEX CONTOUR o SANITARY SEWER CLEANOUT ss ss ss ss GAS METER SANITARY SEWER LINE D4 GAS VALVE G---G---G---c GAS LINE ------------- ------ STORM SEWER PIPE w---W-- w---W DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) D4 WATER VALVE — ucT--- ucT--- uGT FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE C8I AIR RELEASE VALVE UNDERGROUND ELECTRIC 6, FIRE DEPARTMENT CONNECTION —oRE--(---oNE—=R O WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD --ucrv---ucry --ucry ® ELECTRIC PEDESTAL UNDERGROUND TELEVISION -- -- GRATED INLET OVERHEAD TELEVISION _ - CHAIN LINK FENCE DROP INLET � m 1..F... _---_ 1-- - WOOD FENCE BARBED WIRE FENCE TREE o FIBER OPTIC RIGHT OF WAY TREE TO BE REMOVED f ROAD CENTERLINE LEGEND (CONSTRUCT) SYMBOLS LINEWORK • SET IRON PIN ------------------ EASEMENT LIGHT POLE ll( POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 0 TV PEDESTAL INTERMEDIATE CONTOUR Q MANHOLE 1205 INDEX CONTOUR O SANITARY SEWER CLEANOUT 55 • GAS METER SANITARY SEWER LINE N GAS VALVE O STORM SEWER PIPE GAS LINE QED STRUCTURE NUMBER ■ WATER LINE WATER VALVE ll -H T FIRE HYDRANT ASSEMBLY UNDERGROUND 11]�'PNONE ucr FBI AIR RELEASE VALVE uce { FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METER ONE 6 BACK FLOW PREVENTER OVERHEAD ELECTRIC • REDUCER FIBER OPTIC FO RECTANGULAR DROP INLET, GRATED INLET OR JUNCTION Um BOX (SPECIFY ON PLAN UNDERGROUND TELEVISION SHEET) --OHTV---allW---OHTV OVERHEAD TELEVISION -� CIRCULAR DROP INLET, GRATED INLET OR JUNCTION CHAIN LINK FENCE BOX (SPECIFY ON PLAN SHEET) WOOD FENCE --„ BARBED WIRE FENCEx tI GENERAL NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE ONLY FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS. 2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPESTRUCTURES S OR SHOWN ON THESE DRAWINGS IS BASED ON A SEARCH OF THE AVAILABLE RECORDS. TO THE BEST OF OUR KNOWLEDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS. CRAFTON TULL ASSUMES NO RESPONSIBILITY REGARDING THE ACCURACY OF THE DEPICTED LOCATION(S) OF THE UNDERGROUND FACILITIES ON THESE DRAWINGS CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ANY OTHER FACILITIES NOT SHOWN ON THESE DRAWINGS CONTRACTOR SHALL VERIFY LOCATION OF ALL FACILITIES BEFORE BEGINNING WORK. 3. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK. THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN OR NEAR THE CONSTRUCTION SITE 4, THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC. AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. 5. CONTRACTOR SHALL NOT CAUSE ANY LONG-TERM INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING CONSTRUCTION OF THIS PROJECT. CONTRACTOR SHALL PROVIDE ACCESS TO ALL ADJACENT PROPERTIES AT ALL TIMES DURING BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE Arkansas One Call Know what's below. Call before you dig. CCWSTRUC'ION, 6. CONTRACTOR SHALL CONTACT THE ENGINEER/ARCHITECT FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED IN THE PLANS OR SPECIFICATIONS. 7. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT WHICH ARE NECESSARY TO CONFORM TO OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. 8. CRAFTON TULL & ASSOCIATES, INC. (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES FOR THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT CRAFTON, TULL & ASSOCIATES, INC. ASSUMES NO RESPONSIBILITY FOR THE INTERPRETATION, COORDINATION, OR ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREOF. FURTHERMORE, GRAFTON, TULL & ASSOCIATES, INC. WILL NOT BE RESPONSIBLE FOR ANY EFFECTS THAT ANY CHANGES TO THESE DOCUMENTS MAY HAVE ON ANY RELATED TRADES, CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT EXCEPT AS SPECIFICALLY NOTED IN THE AGREEMENT BETWEEN CRAFTON, TULL & ASSOCIATES AND THE OWNER. g, ENERGIZED ELECTRICAL LINESAFETY, WARNINGS. AND ADVANCED NOTICES: ALL OWNERS, GENERAL CONTRACTORS, AND SUBCONTRACTORS ASSOCIATED WITH THIS PROJECT SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH, COMPLYING WITH, AND THE ENFORCEMENT OF ARKANSAS CODES AR ST 4 11-5-307 AND§ AR ST 11-5-308 AND ANY OTHER CURRENT STATE CODES PERTAINING TO ADVANCE NOTICE REQUIREMENTS AND FOR SAFETY OF ALL PERSONNEL. INCLUDING THE GENERAL PUBLIC, PERTAINING TO ANY WORK, MOVEMENT, AND ACTIVITY IN CLOSE PROXIMITY TO ANY ENERGIZED ELECTRICAL LINE 10825 Financial Centre Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull ® engineering I surveying 501.664.3245 t 501.664,6704 f www.craftontull.com THE HAMILTON APARTMENTS LITTLE ROCK, ARKANSAS Key Plan i N. Description Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to he used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. ,�S.fRUCTION PROJECT NO: 00 RF` ISSUEDATE: mm/dd/yy ACT THIS FZ2-1 CONTACT: F.RIGGINS DOCUMENT IS N CHECKED BY: 2 PRELIMINARY IN NATURE AND IS NOT PRELIMINARY m A FINAL, SIGNED o PLANS 3 AND SEALED DOCUMENT a° 02017 Crafton,Tull & Associates, Inc. 'o' O13 ' N011onb)s� SITE PLAN MAY 2 4 2017 I C-101