Loading...
HomeMy WebLinkAboutZ-7500-F Map 2\ ass GRAPHIC SCALE IN FEET \\ PROJECT FENCE ENOS\\ \ \\ A 0 40' LOCATION q 12 ` \ ss �' ' VICINITY MAP I if WALL SAfi TA E A SIE11M E o 00 LIB N I \ \ \ w I \ OI N d- f O Z GARAGE (TYP.) CANOPY (TYP.) v N \V., A ���✓ �� FENCE ENDS—, \\ / GARAGE .`� % 0 3 6' ECORATIVE TAL FENCE I _ �, f Cd IT I \ 2 7 �...:... � 2) 2 U* SWING GATE 4.0- � ���• A ' I 9.22' 24 37.42' 7 � ,- � „ V 'y I D n -- -- - �� --o _ _ ----- - _ —T���-- - DECORATIVE ___ --- METAL FENCE \ ACCESS AND TURNAROUND —� — EASEMENT PROJECT DATA APARTMENTS 248 PARKING SPACES: 442 (22 - UNDER BUUILDING, 36 - IN GARAGES, 206 - COVERED, 178 - OPEN) STANDARD 433 ACCESSIBLE 9 PARKING SPACES/UNIT 1.78 SITE 10.67 ACRES (100% ) BUILDING 98,925 SF (21.2% ) IMPERVIOUS AREA 6.0 ACRES (56.3% ) GREEN SPACE 4.67 ACRES (43.7% ) o. SITE NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATICN OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT UNITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETG, GREAt7R THAN FORTY-EIGHT INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL, DATA SHOWN OR REFERENCED HEREIN SHALL BE FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS ONLY. 2. ALL WORK AND MATERIALS SHALL COMPLY WTEH ALL CITY/COUNTY/STATE/TEDFRAL REGULATIONS AND CODES AND OSHA STANDARDS 3, CONTRACTOR SHALL REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATIONS AND DIMENSIONS OF VESTIBULES, SLOPE PAVING, SIDEWALKS, EXIT PORCHES, TRUCK DOCKS, PRECISE BUILDING DIMENSIONS AND EXACT (TILITY ENTRANCE LOCATIONS 4. ALL DIMENSIONS AND RADII ARE TO BACK OF CURB UNLESS OTHERWISE NOTED, 5. ALL WORK SHALL BE DONE IN STRICT ACCORDANCE WITH THE PROJECT SPECIFICATIONS. 6. ALL CURB/SIDEWALK/HANDICAP RAMP DESIGNS SHALL CONFORM TO ADA STANDARDS OR LOCAL RESTRICTIVE CODES, WHICHEVER IS MORE RESTRICTIVE 7. CONTRACTOR SHALL ENSURE ALL NECESSARY PERMITS ARE OBTAINED PRIOR TO CONSTRUCTION START. B. CONTRACTOR SHALL MATCH NEW CURB AND WATER, CONCRETE, AND PAVEMENT TO EXISTING IN GRADE AND ALIGNMENT. B. CONTRACTOR SHALL MAINTAIN ALL EXISTINGPARKINC, SIDEWALKS, DRIVES, ETC. CLEAR AND FREE FROM ANY CONSTRUCTION ACTIVIY AND/OR MATERIAL TO ENSURE EASY AND SAFE PEDESTRIAN AND VEHICULAR TRAFFIC'0 AND FROM THE SITE. \ F FLOODWAY \ _ ACCESS \.EASEMENT EMERGENCY EXIT GATE W/KNOXBOX o. LEGEND (EXISTING SYMBOLS) SYMBOLS LINEWORK o FOUND IRON PIN EASEMENT 3� LIGHT POLE ___ ____ _________ � POWER POLE CURB m TELEPHONE PEDESTAL _- ..-. ...... ...... 205 _ EN TV PEDESTAL INTERMEDIATE CONTWR O MANHOLE INDEX CONTOUR e SANITARY SEWER CLEANOUT _ ss ss ss ss 0 GAS METER SANITARY SEWER LINE I>< GAS VALVE —c--c---G---c GAS LINE -__- - STORM SEWER PIPE _ W—W---W---W DOWN GUY WATER LINE (SPECIFY SIZE & TYPE) DQ WATER VALVE -- UCT----UGT--- UOT FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE C81 AIR RELEASE VALVE —UGE--( - UNDERCRWFD ELECTRIC —VGE—� A FIRE DEPARTMENT CONNECTION —ONE--(r----ONE— � O WATER METER OVERHEAD ELECTRIC ® SPRINKLER HEAD —UGTV---UGTV---UON m ELECTRIC PEDESTAL UNDERGROUND TELEVISION OHTV---GHTV OHTV — , OVERHEAD TELEVISION GRATED INLET ===1 CHAIN LINK FENCE (� (; DROP INLET _J WOOD FENCE BARBED WORE FENCE TREE FO FIBER OPTIC RIGHT OF WAY X TREE TO BE REMOVED ROAD CENTERLINE LEGEND (CONSTRUCT) SYMBOLS LINEWORK • SET IRON PIN ------------------ EASEMENT LIGHT POLE tit POWER POLE CURB ■ TELEPHONE PEDESTAL 1206 TV PEDESTAL INTERMEDIATE CONTOUR 0 MANHOLE 1205 INDEX CONTOUR 0 SANITARY SEWER CLEANOUT SS A GAS METER SANITARY SEWER LINE ►� GAS VALVE O STORM SEWER PIPE GAS LINE STRUCTURE NUMBER r WATER LINE WATER VALVE ll `N'' T FIRE HYDRANT ASSEMBLY UNDERGROUND TELEPHONE ucr RBI AIR RELEASE VALVE UGE 1 F FIRE DEPARTMENT CONNECTION UNDERGROUND ELECTRIC • WATER METIER WE B BACK FLOW PREVENTER OVERHEAD ELECTRIC ♦ REDUCER OPTIC FinH`C3ER RECTANGULAR DROP INLET, GRATED INLT OR JUNCTION Um BOX (SPECIIY ON PLAN UNDERGROUND TELEVISION SHEET) --mw---011TV---wry OVERHEAD TELEVISION .� CIRCULAR DROP INLET, GRATED INLET OR JUNCTION CHAIN LINK FENCE o o BOX (SPECIFY ON PLAN SHEET) Al �- WOOD FENCE R — BARBED WIRE FENCE BUILDING SET BACK RIGHT OF WAY PROPERTY LINE ROAD CENTERLINE i . GENERAL NOTES 1. THE DESIGN, INSPECTION, AND CERTIFICATION OF ANY RETAINING WALL SHOWN OR REFERENCED HEREIN, INCLUDING BUT NOT LIMITED TO, SEGMENTAL RETAINING WALLS, MASS GRAVITY WALLS, GABION WALLS, ETC., GREATER THAN FORTY-EIGHII INCHES IN HEIGHT, SHALL BE BY OTHERS. ANY RETAINING WALL DATA SHOWN OR REFERENCED HEREIN SHALL BE ONLY FOR COORDINATION OF THE WALL LOCATION AND ELEVATIONS. 2. THE EXISTENCE AND LOCATION OF ANY UNDERGROUND UTILITY PIPES OR STRUCTURES SHOWN ON THESE DRAWINGS IS BASED ON A SEARCH OF THE AVAILABLE RECORDS, TO THE BEST OF OUR KNOW -EDGE THERE ARE NO EXISTING UTILITIES EXCEPT AS SHOWN ON THESE DRAWINGS. GRAFTON TULL ASSUMES NO RESPONSIBILITY REGARDING THE ACCURACY OF THE DEPICTED LOCATION(S) OF THE UNDERGROUND FACILITIES ON THESE DRAWINGS CONTRACTOR IS RESPONSIBLE FOR THE LOCATION AND PROTECTION OF ANY OTHER FACILITIES NOT SHOWN ON THESE DRAWINGS CONTRACTOR SHAH VERIFY LOCATION OF ALL FACILITIES BEFORE BEGINNING WORK. 3. IN ACCORDANCE WITH GENERALLY ACCEPTED CONSTRUCTION PRACTICES, THE CONTRACTOR WILL BE SOLELY AND COMPLETELY RESPONSIBLE FOR CONDITIONS OF THE JOB SITE INCLUDING SAFETY OF ALL PERSONS AND PROPERTY DURING PERFORMANCE OF THE WORK, THIS REQUIREMENT WILL APPLY CONTINUOUSLY AND NOT BE LIMITED TO NORMAL WORKING HOURS. THE DUTY OF THE ENGINEER TO CONDUCT CONSTRUCTION REVIEW OF THE CONTRACTOR'S PERFORMANCE IS NOT INTENDED TO INCLUDE REVIEW OF THE ADEQUACY OF THE CONTRACTOR'S SAFETY MEASURES IN OR NEAR THE CONSTRUCTION SITE 4. THIS DOCUMENT AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICES, IS THE PROPERTY OF CRAFTON, TULL & ASSOCIATES, INC, AND IS NOT TO BE USED, IN WHOLE OR PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF CRAFTON, TULL & ASSOCIATES, INC. 5. CONTRACTOR SHALL NOT CAUSE ANY LONG-TERM INCONVENIENCE TO THE PUBLIC, ADJACENT PROPERTY OWNERS, PEDESTRIANS, ETC. DURING CONSTRUCTION OF THIS PROJECT, CONTRACTOR SHALL PROVIDE ACCESS TO ALL ADJACENT PROPERTIES AT ALL TIMES DURING Arkansas One Call Know what's below. Cal I before you dig. CONSTRUCTION. 6. CONTRACTOR SHALL CONTACT THE ENGINEER/ARCHITECT FOR CLARIFICATION IF A DISCREPANCY OR INCONSISTENCY IS IDENTIFIED IN THE PLANS OR SPECIFICATIONS. 7. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN AND IMPLEMENTATION OF ALL SHEETING, SHORING, AND SPECIAL EXCAVATION MEASURES REQUIRED ON THE PROJECT WHICH ARE NECESSARY TO CONFORM TO OSHA, FEDERAL, STATE AND LOCAL REGULATIONS. S. MAFTON TULL & ASSOCIATES, INC. (CTA) HAS NOT BEEN RETAINED BY THE OWNER FOR CONSTRUCTION ADMINISTRATION OR OBSERVATION SERVICES FOR THE WORK INDICATED ON THESE DRAWINGS. THEREFORE, CTA HEREBY NOTIFIES ALL PARTIES INVOLVED THAT DW70N, TULL & ASSOCIATES, INC. ASSUMES NO RESPONSIBILITY FOR THE NTETRPREfATION, COORDINATION, OR ADMINISTRATION OF THESE DOCUMENTS AND/OR DEVIATIONS THEREOF. FURTHERMORE, CRAFTON, TULL & ASSOCIATES, INC. WILL NOT BE RESPONSIBLE FOR ANY EFFECTS THAT ANY CHANGES TO THESE DOCUMENTS MAY HAVE ON ANY RELATED TRADES, CONSTRUCTION SEQUENCES, OR OPERATION OF THE COMPLETED PROJECT EXCEPT AS SPECIFICALLY NOTED IN THE AGREEMENT BETWEEN CRAFTON, TULL & ASSOCIATES AND THE OWNER. 9. ENERGIZED FI-ECTRICAL I INE SAFETY, WARNINGS, AND ADVANCED NOTIC S ALL OWNERS, GENERAL CONTRACTORS, AND SUBCONTRACTORS ASSOCIATED WITH THIS PROJECT SHALL BE RESPONSIBLE FOR FAMILIARIZING THEMSELVES WITH, COMPLYING WITH, AND THE ENFORCEMENT OF ARKANSAS COIFS AR ST § 11-5-307 AND § AR ST 11-5-308 AND ANY OTHER CURRENT STATE CODES PERTAINING TO ADVANCE NOTICE REQUIREMENTS AND FOR SAFETY OF ALL PERSONNI-1INCLUDING THE GENERAL PUBLIC, PERTAINING M ANY WORK, MOVEMENT, AND ACTIVITY IN CLOSE PROXIMITY TO ANY ENERGIZED ELECTRICAL LINE 10825 Financial Centre Parkway, Suite 300 Little Rock, Arkansas 72211 Crafton Tull ® engineering surveying 501.664.3245 t 501.664.6704 f www.craftontull.com I THE HAMILTON APARTMENTS LITTLE ROCK, ARKANSAS Key Plan NoDesci Ption Date This document, and the ideas and designs incorporated herein, as an instrument of professional service, is the property of Crafton, Tull & Associates, Inc., and is not to be used, in whole or in part, for any other project, without the written authorization of Crafton, Tull & Associates, Inc. �S.11?,UCTION PROJECT NO: oo RF,� ISSUEDATE: mm/dd/YY THIS F� CONTACT: F.RIGGINS DOCUMENT IS N CHECKED BY: -- PRELIMINARY IN NATURE AND IS NOT PRELIMINARY m A FINAL, SIGNED o PLANS z AND SEALED DOCUMENT �o © 2017 Crafton, Toll & Associates, Inc. db, 00 ° NoiionaLs� SITE PLAN MAY 2 4 2017 I C - 1