HomeMy WebLinkAboutZ-9498 Staff AnalysisMarch 12, 2020
ITEM NO.: 6
NAME:
LOCATION:
OWNER/APPLICANT
FILE NO.: Z-9498
Phillips Duplexes — Conditional Use Permit
Mid -block, east side, 4400 block of Malloy Street
Samantha Duelmer/Stanley Phillips
PROPOSAL: A conditional use permit is requested to allow the
construction of two duplexes on property zoned R-3.
1. SITE LOCATION:
The site is located on the east side of Malloy Street between West 44th Street
and West 46th Street.
2. COMPATIBILITY WITH NEIGHBORHOOD:
This property is situated mid -block on the east side of Malloy Street. This area is
characterized by residential uses, primarily single-family. About one-third of the
lots on this two -block section of Malloy Street are undeveloped; however, the
properties abutting this parcel are all developed with residences. Malloy Street is
two blocks west of John Barrow Road. This site is also less than a quarter mile
north of Colonel Glenn Road. Duplex residential units would be compatible with
both the commercial and residential development in the vicinity.
Notice of the public hearing was sent to the John Barrow Neighborhood
Association.
3. ON SITE DRIVES AND PARKING:
The proposed development would have a shared driveway 20-feet in width
situated near the midpoint of the lot frontage along Malloy Street. This driveway
would connect to an eight -space parking area, dividing four spaces to each side
of the maneuvering area. Per the zoning ordinance, 1.5 spaces are required for
each dwelling unit, the 8 proposed spaces exceed the standard.
4. SCREENING AND BUFFERS:
Any new site development must comply with the City's minimal landscape and
buffer ordinance requirements.
A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property, or the right-of-way of any street. This strip shall be at
March 21, 2020
ITEM NO.: 6 (Cont.) FILE NO.:
least nine (9) feet wide. One (1) tree and three (3) shrubs or vines shall be
planted for every thirty (30) linear feet of perimeter planting strip.
Screening requirements will need to be met for the vehicular use areas adjacent
to street right-of-way. Provide screening shrubs with an average linear spacing
of not less than three (3) feet within the required landscape area. Provide trees
with an average linear spacing of not less than thirty (30) feet.
The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper or larger.
5. PUBLIC WORKS:
Malloy Street is classified on the Master Street Plan as a residential street.
A dedication of right-of-way 25 feet from centerline will be required.
6. UTILITIES/FIRE DEPARTMENT/BUILDING CODES:
Little Rock Water Reclamation Authority: Sewer available to this site. Separate
service required for each building. 2 units per building service line is allowed.
Entergy: Entergy does not object to this proposal. There does not appear to be
any conflicts with existing electrical utilities at this location. Contact Entergy in
advance to discuss electrical service requirements, or adjustments to existing
facilities (if any) as this project proceeds.
CenterPoint Energy: No comments received.
AT&T: No comments received.
Central Arkansas Water: No comments received.
Fire Department:
Full Plan Review
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
2
March 21, 2020
ITEM NO.: 6 (Cont.) FILE NO.:
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access
roads shall not exceed 10 percent in grade except as approved by the fire chief.
Loadinq
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface
capable of supporting the imposed load of fire apparatus weighing at least
75,000 pounds.
r)pari Fnrlc
Maintain fire apparatus access roads at dead end locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.4 Dead Ends. Dead-end fire apparatus access roads in excess of 150 feet
shall be provided with width and turnaround provisions in accordance with Table
D103.4. Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply
with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times
and replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and
padlock unless they are capable of being opened by means of forcible entry
tools or when a key box containing the keys to the lock is installed at the
gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
3
March 21, 2020
ITEM NO.: 6
FILE NO.: Z-9498
8. Electric gate operators, where provided, shall be listed in accordance with
U L 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two -Family dwelling residential developments.
Developments of one- or two-family dwellings where the number of dwelling units
exceeds 30 shall be provided with two separate and approved fire apparatus
access roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road
shall not be increased unless fire apparatus access roads will connect
with future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office
(Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number
and Distribution of Fire Hydrants as per Table C105.1.
Building Codes: Project is subject to full commercial plan review and approval
prior to issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner to coordinate
review:
Curtis Richey at 501.371.4724 cricheyalittlerock. gov or
Steve Crain at 501.371-4875 scrain(ablittlerock.gov
7. TRANSPORTATION/PLANNING.
County Planning: No comments received.
Rock Region METRO: No comments received.
52
March 21, 2020
ITEM NO.: 6 (Cont.
Planning Division: No comments received.
FILE NO.: Z-9498
SUBDIVISION COMMITTEE COMMENT: (February 19, 2020)
The applicant was present. Staff introduced the item and requested a platted access
easement be added to the final plat for the property. A request was also made to
consider additional landscaping on the property to enhance the residential appear and
diminish the visual impact of the parking area. Lastly, the applicant was reminded of the
requirement for notification of property owners.
Public works brought up the requirement for dedication of 25-feet of right-of-way from
the centerline of Malloy Street.
Landscape comments included the perimeter planting strip required along any side of a
vehicular use area abutting adjoining property or the right-of-way of any street. One
tree and three shrubs must be planted for each 30 linear feet of planting strip and the
strip must be a minimum of 9 feet in width.
Other comments were generally noted.
The applicant was advised to respond to comments and issues by February 26, 2020.
The item was forwarded by the committee for consideration by the planning
commission.
STAFF ANALYSIS:
Development within the R-3 district must comply with the following development
standards:
Front yard setback of not less than 25-feet
Side yard setback of no less than 10% of the average lot width,
but not to exceed 8-feet
• Rear yard setback of not less than 25 feet
® Building height of no greater than 35 feet
The proposed duplexes would be in compliance with the development standards. The
applicant has indicated he intends to construct two-story buildings each containing two
dwelling units.
As noted, the number of parking spaces provided exceeds the minimum.
5
March 21, 2020
ITEM NO.: 6 (Cont.
FILE NO.: Z-9498
The applicant will provide additional right-of-way for Malloy Street and intends to exceed
the required landscaping within the perimeter planting strip.
A handful of duplexes have been approved through the conditional use process in the
John Barrow neighborhood. Staff is supportive of this request as it is not out of
character with the residential nature of the vicinity.
STAFF RECOMMENDATION. -
Staff recommends approval of the requested CUP to allow the construction of two
duplexes on the property subject to compliance with the comments and conditions
outlined in Sections 4, 5, and 6 of the agenda staff report.
PLANNING COMMISSION ACT
(MARCH 12, 2020)
The applicant was present. There were no registered objectors present. Staff presented
the item and a recommendation of approval as outlined in the "staff recommendation"
above. There was no further discussion. The item was placed on the consent agenda
and approved as recommended by staff, including all staff comments and conditions.