HomeMy WebLinkAboutZ-9466 Staff AnalysisFebruary 20, 2020
ITEM NO.: B FILE NO.: Z-9466
NAME: Kanis Office Building Short -form PCD
LOCATION: 17201 Kanis Road
DEVELOPER:
Ben Robles
Kanis Land LLC
17201 Kanis Road
Little Rock, AR 72211
OWNER/AUTHORIZED AGENT:
Kanis Land LLC/Owner
Rogue Architecture/Agent
SURVEYOR/ARCHITECT:
Brooks Surveying, Inc./Surveyor
Rogue Architecture/Architect
AREA: 0.714 acres
WARD: N/A
RRENT ZONING
ALLOWED USES
NUMBER OF LOTS: 1
PLANNING DISTRICT: 18
R-2, Single-family Residential
Single-family Residence
FT. NEW STREET: 0 LF
CENSUS TRACT: 42.07
PROPOSED ZONING: PCD, Planned Commercial Development
PROPOSED USE: Mixed Office and Commercial
VARIANCE/WAIVERS: None
BACKGROUND:
This property is situated immediately west of the city limits on the south side of Kanis
Road. The tract contains slightly more than 0.70-acres and is developed with a residence.
Staff is unaware of any previous zoning actions regarding this property.
February 20, 2020
SUBDIVISION
ITEM NO.: B Cont. FILE NO.: Z-9466
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant proposes to construct a 50-foot by 145-foot steel two-story structure
after demolishing the residence on the site.
Associated parking and new utilities would also be constructed.
Mixed Commercial and Office uses are proposed for the site.
B. EXISTING CONDITIONS:
The site is somewhat wooded and currently is developed with a residential
structure. Immediately to the west is an Entergy electric transmission line
connecting to the substation situated across Kanis Road to the northwest. All of
the abutting property is undeveloped and wooded.
Kanis Road transitions from a five -lane improved road to the east toward the
intersection with Chenal Parkway to an unimproved two-lane road to the west at
this location. This site is less than a quarter of a mile west of the intersection of
Kanis Road and Chenal Parkway and less than a half mile from the intersection of
Kanis Road with Rahling Road.
C. NEIGHBORHOOD COMMENTS,
As of this writing, staff has not received any comments from area property owners
or neighborhood associations. Notice of the public hearing was sent to the Citizens
of West Pulaski County and all owners of properties located within 200 feet of
the site.
D. ENGINEERING COMMENTS:
BLIC WORKS CONDITIONS:
Kanis Road is classified on the Master Street Plan as a minor arterial.
A dedication of right-of-way 45 feet from centerline will be required.
2. With site development, provide design of street conforming to the Master Street
Plan. Construct one-half street improvement to Kanis Road including 5-foot
sidewalks with planned development. The new curb should connect with the
existing curb to the east and taper to 59 ft. at the west property line measured
from the existing back of curb on the northside of Kanis Road.
2
February 20, 2020
SUBDIVISION
ITEM NO.: B Cont. FILE NO.. Z-9466
3. Show the proposed driveway connection from the subject property to the Kanis
Road right-of-way with written permission from the adjacent property owners
for construction.
4. If the property is proposed to be annexed into the City of Little Rock, a grading
permit in accordance with section 29-186 (c) & (d) will be required prior to any
land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved
prior to the start of construction.
5. Storm water detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan. Maintenance of the
detention pond and all private drainage improvements is the responsibility of
the developer and/or property owner.
6. Damage to public and private property due to hauling operations or operation
of construction related equipment from a nearby construction site shall be
repaired by the responsible party prior to issuance of a certificate of occupancy.
E. UTILITIES/FIRE DEPARTMENT/PARKSICOUNTY PLANNING
Little Rock Water Reclamation Authority. -
Outside Service Boundary — No Comment.
Entergy
Entergy cannot commit to this proposal at this time. The property is close to
the Transmission lines and typically Transmission ROW is 100 to 150ft. This
would need to be referred to our Transmission Group for a decision. Tina
Givens kgivens@entergy.com and Aaron Boone rboone1@entergy.com
would be the place to start. I have forwarded this to them.
There does not appear to be any conflicts with existing electrical distribution
utilities, however the green spaces appear to be in the distribution ROW and
would be subject to trimming. Entergy would prefer that green space
plants/trees should be selected with consideration of the overhead lines
around the property. Contact Entergy in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project proceeds.
CenterPoint Ener :
Our facilities run within the eastern edge of the utility Right -of -Way marked on the
proposed plat as "Assumed Entergy Right -of -Way For Overhead Power Lines".
3
February 20, 2020
SUBDIVISION
ITEM NO.: B (Cont.) FILE NO.: Z-9466
CNP requests our natural gas facilities be located and surveyed so they may be
added to the proposed plat prior to approval.
AT & T: No comment received.
Central Arkansas Water:
All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
Please submit plans for water facilities and/or fire protection system to Central
Arkansas Water for review. Plan revisions may be required after additional review.
Contact Central Arkansas Water regarding procedures for installation of water
facilities and/or fire service. Approval of plans by the Arkansas Department of
Health Engineering Division and Little Rock Fire Department is required.
Due to the nature of this facility, installation of an approved reduced pressure zone
backflow preventer assembly (RPZ) is required on the domestic water service. This
assembly must be installed prior to the first point of use. Central Arkansas Water
(CAW) requires that upon installation of the RPZA, successful tests of the
assembly must be completed by a Certified Assembly Tester licensed by the State
of Arkansas and approved by CAW. The test results must be sent to CAW s Cross
Connection Section within ten days of installation and annually thereafter. Contact
the Cross Connection Section at 377-1226 if you would like to discuss backflow
prevention requirements for this project.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall
not exceed 10 percent in grade except as approved by the fire chief.
ll
February 20, 2020
SUBDIVISION
ITEM N
Loading
FILE NO.: Z-9466
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments — 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5
February 20, 2020
SUBDIVISION
ITEM NO.: B (Cont.) FILE NO.: Z-9466
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office
(Capt. Tony Rhodes 501-918-3757 or Capt. John Hogue 501-918-3754). Number
and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation. No comment received.
County Planning: No comment.
F. BUILDING CODES/LANDSCAPE
Building Code:
Project is subject to full commercial plan review and approval prior to issuance of
a building permit. For information on submittal requirements and the review
process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; crichey(a-littlerock.gov or
Steve Crain at 501-371-4875; _scrain __littlerock.gov.
Landscape:
1. Site plan must comply with the City's minimal landscape and buffer ordinance
requirements.
10
February 20, 2020
SUBDIVISION
ITEM NO.: B (Cont.) FILE NO Z-9466
2. Street buffers will be required at six (6) percent of the average depth of the lot.
The minimum dimension shall be one-half ('/2) the full width requirement but in
no case be less than nine (9) feet. The street buffer is deficient. The
approximate average depth of the site is 300 feet. A minimum ei hteen
18 foot street buffer is required between the Kanis Road right-of-way and
the Proposed Rarking.
3. Screening requirements will need to be met for the vehicular use .areas
adjacent to street rights -of -way. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape area.
Provide trees with an average linear spacing of not less than thirty (30) feet.
4. A perimeter planting strip is required along any side of a vehicular use area that
abuts adjoining property or the right-of-way of any street, highway or freeway.
This strip shall be at least nine (9) feet wide. Provide trees with an average
linear spacing of not less than thirty (30) feet within the perimeter planting strip.
Provide three (3) shrubs or vines for every thirty (30) linear feet of perimeter
planting strip. The east perimeter planting strip is deficient. The north, south,
east and west perimeter planting strips are deficient. The minimum
dimension shall be nine (9) feet in all instances.
5. Landscape areas shall be provided between the vehicular use area used for
public parking and the general vicinity of the building, excluding truck loading
or service areas not open to public parking. These areas shall be equal to an
equivalent planter strip three (3) feet wide along the vehicular use area.
Buildinq landscape areas are deficient.
6. A land use buffer six (6) percent of the average width / depth of the lot will be
required when an adjacent property has a dissimilar use of a more restrictive
nature. The property to the west is zoned R-2. As a component of all land use
buffer requirements, opaque screening, whether a fence or other device, six (6)
feet in height shall be required upon the property line side of the buffer. In
addition to the required screening, buffers are to be at the rate of one (1) tree
and three (3) shrubs for every thirty (30) linear feet. The land use buffer is
deficient. The minimum dimension shall be nine 9 feet in all instances
7. Eight percent (8%) of the vehicular use area must be designated for green
space, this green space needs to be evenly distributed throughout the parking
area(s). The minimum size of an interior landscape area shall be one hundred
fifty (150) square feet for developments with one hundred fifty (150) or fewer
parking spaces. Interior islands must be a minimum of seven and one half
(7 1/2) feet in width. Trees shall be included in the interior landscape areas at
7
February 20, 2020
SUBDIVISION
ITEM NO.: B (Cont.) FILE NO.: Z-9466
the rate of one (1) tree for every twelve (12) parking spaces. Interior
landscape areas may be deficient.
8. The City Beautiful Commission recommends preserving as many existing trees
as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
G. TRANSPORTATION/PLANNING:
Rock Region Metro: No comment.
Planning Division: The request is in the Ellis Mountain Planning District. The Land
Use Plan shows Mixed Office Commercial (MOC) for the requested area. Mixed
Office Commercial category provides for a mixture of office and commercial uses
to occur. Acceptable uses are office or mixed office and commercial. A Planned
Zoning District is required if the use is mixed office and commercial. The
application is to change an area from R-2 (Single Family District) to PCD (Planned
Commercial Development) District to allow construction of a two-story office
building on the site.
Master Street Plan: To the north is Kanis Road and it is shown as a Minor Arterial
on the Master Street Plan. A Minor Arterial provides connections to and through
an urban area and their primary function is to provide short distance travel within
the urbanized area. Entrances and exits should be limited to minimize negative
effects of traffic and pedestrians on Kanis Road since it is a Minor Arterial. This
street may require dedication of right-of-way and may require street improvements
for entrances and exits to the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
H. SUBDIVISION COMMITTEE COMMENT: October 30, 2019
The applicant was present. Staff presented the item to the committee. Planning
comments included additional information on the mix of uses, whether just office
was proposed or some commercial uses and on the proposed signage.
Public Works noted storm water and drainage requirements applied to the site,
also additional right-of-way and road improvements to Kanis Road were required
with development.
Landscape comments were in regard to the insufficient buffers, perimeter strips,
interior landscaping, and building landscaping illustrated on the site plan.
H.,
February 20, 2020
SUBDIVISION
ITEM NO.: B (Cont.
I L E NO.: Z-9466
Additional comments from Entergy stating the proposed use of the abutting power
line easement for site access from Kanis Road as well as any landscaping
proposed to be located within the easement.
CenterPoint also indicated a gas line was not shown on the preliminary plan and
should be added.
The applicant was informed responses were to be received by November 6, 2019.
The committee forwarded the item to the full commission.
ANALYSIS:
A revised site plan and comments were submitted by the applicant.
As the project is still being designed, the signage remains undetermined. Any
signage would comply with the allowed maximum for office zones. This would
allow for a freestanding sign of up to 64 square feet in area and 6 feet in height.
Additionally, there may be either wall signs of up to 10% of the fagade area or a
projecting sign or under -canopy sign of up to 12 square feet in area for each
occupancy.
The owner intends to lease the building for office use; however would like to also
reserve the option for some retail use or a cafe. A full -service restaurant would not
be allowed, nor would a drive-thru.
Additional right-of-way for Kanis Road has been added to the site plan and the
half -street improvements with a five-foot sidewalk would be constructed, as
requested by Public Works.
A drive toward the east edge of the property will provide access to Kanis Road.
This drive would be 26-feet in width. Public Works finds this drive to have adequate
site distance. No access is proposed to the property to the east. A potential
connection to the property to the west is indicated. This would require written
permission of the property owner before construction.
Underground detention is planned for storm water ordinance compliance.
A landscape strip is shown on the west property boundary. This would be
maintained in conformance to the requirements of Entergy regarding the overhead
power lines.
The applicant states the building is located outside of any utility easements.
9
February 20, 2020
SUBDIVISION
ITEM NO.: B Cont. FILE NO.: Z-9466
An 18-foot wide street buffer is shown with illustrative landscaping along Kanis
Road.
Building landscaping has been added to the west side of the structure
An opaque screen is not clearly identified for the land use buffer on the west
property line. This would be added during review for permits.
Interior landscaping has been provided. It appears the landscaping provided is
still insufficient. This may also be addressed during permit review.
The applicant has stated no trees are proposed to be preserved with the
development.
The revised site plan shows 17 parking spaces. The proposed building is
13,000-square feet in area. For office uses, the zoning ordinance requires one
parking space for each 400 square feet of gross square footage of the building,
yielding a requirement of 32 parking spaces. A reduction of 5% is allowed for
buildings with an area of 10,000 to 20,000 square feet. This would make the
requirement 31 parking spaces. As the overall mix of office/retail/limited restaurant
uses has not been identified, it is not possible to calculate the minimum number of
parking spaces required; however, as the ratio of parking spaces to gross square
footage for retail uses is one space per 300 square feet of gross floor area, yielding
a requirement for more than 31 spaces.
Staff is supportive of the proposed office and limited commercial uses for the
property. Staff is not supportive of the current proposal and would suggest the
square footage of the building be reduced.
J. STAFF RECOMMENDATION
Staff recommends denial of the proposal due to the number of parking spaces to
be provided is insufficient for the proposed uses of the property and size of the
building and the lack of specificity regarding the proposed use mix.
PLANNING COMMISSION ACTION: (NOVEMBER 21, 2019)
The applicant was not present. There were no registered objectors present. Staff
informed the commission that a request to defer the item was received by staff on
November 7, 2019. Staff recommends approval of the deferral request. There was no
further discussion. The item was placed on the consent agenda and deferred to the
January 9, 2020 agenda. The vote was 10 ayes, 0 noes, and 1 absent.
10
February 20, 2020
SUBDIVISION
ITEM NO.: B (Cont.) FILE NO.: Z-9466
PLANNING COMMISSION ACTION: (JANUARY 9, 2020)
The applicant was not present. There were no registered objectors present. Staff
informed the commission that a request to defer the item to the February 20, 2020
meeting was received by staff on December 29, 2019. Staff recommends approval of the
deferral request. There was no further discussion. The item was placed on the consent
agenda and the item was deferred to the February 20, 2020 meeting. The vote was
10 ayes, 0 noes, and 1 absent.
PLANNING COMMISSION ACTION: (FEBRUARY 20, 2020)
The applicant was not present. There were no registered objectors present. Staff
informed the commission that staff received a request to withdraw the item without
prejudice on February 19, 2020. There was no further discussion. The item was placed
on the consent agenda and approved as recommended by staff. The vote was 9 ayes,
0 noes, and 2 absent.
11
January 9, 2020
ITEM NO. C FILE NO.: Z-9466
NAME: Kanis Office Building Short -form PCD
LOCATION: 17201 Kanis Road
npvpi nppQ-
Ben Robles
Kanis Land LLC
17201 Kanis Road
Little Rock, AR 72211
OWNER/AUTHORIZED AGENT:
Kanis Land LLC/Owner
Rogue Architecture/Agent
SURVEYOR/ARCHITECT-
Brooks Surveying, Inc./Surveyor
Rogue Architecture/Architect
AREA: 0.7.14 acres
WARD: N/A
CURRENT ZONING
ALLOWED USES
PROPOSED ZONING
PROPOSED USE:
VARIANCE/WAIVERS:
NUMBER OF LOTS: 1
PLANNING DISTRICT: 18
R-2, Single-family Residential
Single-family Residence
FT. NEW STREET: 0 LF
CENSUS TRACT: 42.07
PCD, Planned Commercial Development
General Office
PLANNING COMMISSION ACTION:
(NOVEMBER 21, 2019)
The applicant was not present. There were no registered objectors present. Staff
informed the commission that a request to defer the item was received by staff on
November 7, 2019. Staff recommends approval of the deferral request. There was no
January 9, 2020
SUBDIVISION
ITEM NO.: C Cont. FILE NO.: Z..9466
further discussion. The item was placed on the consent agenda and deferred to the
January 9, 2020 agenda. The vote was 10 ayes, 0 noes, and 1 absent.
S�r.r. Ito^..^.T AKIM. ^n�AIMAE:KIMATlfl�l
! J'^%F ` rPi Jry l E r-kNU REC"(DiN 1V11_IVL rn 1 1tJ1V.
On December 29, 2019, a deferral of this item to the February 20, 2020, meeting was
requested by the applicant. Staff recommends approval of the deferral request.
PLANNING COMMISSION ACTION: (JANUARY 9, 2020)
The applicant was not present. There were no registered objectors present. Staff
informed the commission that a request to defer the item to the February 20, 2020
meeting was received by staff on December 29, 2019. Staff recommends approval of the
deferral request. There was no further discussion. The item was placed on the consent
agenda and the item was deferred to the February 20, 2020 meeting. The vote was
10 ayes, 0 noes, and 1 absent.
E
November 21, 2019
ITEM NO.: 11 FILE NO.: Z-946E
NAME: Kanis Office Building Short -form PCD
LOCATION: 17201 Kanis Road
Ben Robles
Kanis Land LLC
17201 Kanis Road
Little Rock, AR 72211
OWNER/AUTHORIZED AGENT:
Kanis Land LLC/Owner
Rogue Architecture/Agent
SURVEYOR/ARCHITECT:
Brooks Surveying, Inc./Surveyor
Rogue Architecture/Architect
AREA: 0.7.14 acres
CURRENT ZONING
ALLOWED USES
NUMBER OF LOTS: 1
PLANNING DISTRICT: 18
R-2, Single-family Residential
Single-family Residence
NEW STREET- 0 LF
CENSUS TRACT: 42.07
PROPOSED ZONING: PCD, Planned Commercial Development
PROPOSED USE: General Office
VARIANCEM/AIVERS-
AFF UPDATE AND RECOMMENDATIO
On November 7, 2019, a deferral of this item to the January 9, 2020, meeting was
requested by the applicant. Staff recommends approval of the deferral request.
November 21, 2019
SUBDIVISION
ITEM NO.: 11
FILE NO. Z-9466
PLANNING COMMISSION ACTION: (NOVEMBER 21, 2019)
The applicant was not present. There were no registered objectors present. Staff
informed the commission that a request to defer the item was received by staff on
November 7, 2019. Staff recommends approval of the deferral request. There was no
further discussion. The item was placed on the consent agenda and deferred to the
January 9, 2020 agenda. The vote was 10 ayes, 0 noes, and 1 absent.
1