Loading...
HomeMy WebLinkAboutZ-9463 Staff AnalysisOCTOBER 28, 2019 ITEM NO.: 7 File No.: Z-9463 Owner: Centennial Bank Applicant: Jason Bouwknegt Address: 1301 Rebsamen Park Road Description Lots 1 and 2, Mauney Ross Commercial Addition and Lot 2, Top Cat Addition Zoned: C-3 and 1-2 Variance Requested: A variance is requested from the area provisions of Section 36- 320 to allow the drive-thru canopy portion of a new building with a reduced side setback. Justification: The applicant's justification is presented in an attached letter. Present Use of Property: Vacant Commercial Buildings Proposed Use of Property: Bank STAFF REPORT A. Public Works Issues: 1. Public Works has no comment with regard to the requested variance to Chapter 36 of the Code of Ordinances. 2. Prior to approval of the building permit, the applicant must agree to contact Public Works, Civil Engineering Private Development at 501-371-4461 or 501- 744-1773 for inspections of any work in the public right-of-way prior to placement of concrete or asphalt or for on -site clarification of requirements prior to commencing work. Failure to do so can result in removal of any improperly placed concrete or asphalt at the expense of the owner or contractor. 3. Prior to approval of the building permit, a grading permit must be obtained if total cut or fill equals or exceeds 1,000 cubic yards. If a grading permit is not required; however, all construction work must include appropriate drainage and erosion control measures (i.e. hay bales, silt fencing, mulching etc.) to protect the municipal storm water drainage system and neighboring properties from sediment runoff. New development may be subject to inspections for compliance. 4. Hauling of fill material on or off project sites over municipal streets require approval prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway 501-379-1805 with any questions or for more information. OCTOBER 28, 2019 ITEM NO.: 7 (CON'T. 5. Prior to approval of the building permit, the applicant must show that the total impervious area is less than or equal to the current impervious surface area. If additional impervious surface is proposed, stormwater detention must be provided in accordance with the City of Little Rock Stormwater Management and Drainage Manual. 6. The maximum cross slope at the sidewalk crossing is 1:50 over a 3-foot pathway. All driveway aprons within the public right-of-way shall be a minimum eight (8) inches thick of 3000 psi concrete and must conform to Ordinance #16,577 and #18,031 for grade, spacing, and other design provisions. Driveway aprons must be installed per City of Little Rock Standard Details PW-30 thru PW-35. 7. Prior to the certificate of occupancy, the applicant must provide five (5) foot wide sidewalks with ADAAG compliant ramps on the property line. Sidewalks are required to be installed per City of Little Rock Standard Details PW-41 thru PW- 47. A one (1) year maintenance bond for newly installed improvements in the right-of-way must be provided to Public Works, Civil Engineering prior to the issue of a certificate of occupancy. 8. Prior to approval of the building permit, the applicant must agree to provide boundary street improvements, if necessary. Boundary street improvements shall include, but not be limited to, reconstruction of one-half section of the abutting street if the existing street is not up to city standards. Where the existing street does not conform to the Master Street Plan, construction of one- half street improvements, including sidewalk at the property boundary, is required. Repair, replace, or extend existing damaged, missing, and noncompliant curb and gutter, sidewalk, access ramps or concrete driveway aprons within the public right-of-way adjacent to the site. Remove abandoned driveway cuts and replace with curb, gutter, and sidewalk. All work within the public right-of-way shall conform to City of Little Rock Standard Details and ADAAG. 9. Plans and specifications for all work in the right-of-way must be prepared by a professional engineer, registered in the State of Arkansas, and two (2) copies submitted for approval prior to construction. 10. Prior to approval of the certificate of occupancy, provide as -built plans and data entry template of newly installed or modified public and private stormwater drainage system prior to issuance of the certificate of occupancy. The as -built plans should contain information as found on the City of Little Rock website at https://www.Iittlerock.gov/city-administration/city-departments/public-works/. Provide the as -built plans and data entry template to Public Works, Civil Engineering Private Development by email to CEPermits@littlerock.gov. If you have any questions or desire additional information, please do not hesitate to contact Public Works, Civil Engineering Private Development at 501-371-4817 or at 501-918-5348 or CEPermits@littlerock.gov. 2 OCTOBER 28, 2019 ITEM NO.: 7 (CON'T. B. Landscape and Buffer Issues: PAWDRO 3 Site plan must comply with the City's minimal landscape / buffer ordinance requirements. A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining property or the right-of-way of any street. A twenty-five (25) percent reduction of the landscape provisions can be taken for developments within mature areas. In these areas it is allowable for perimeter planting strips to be a minimum of six (6) feet nine (9) inches wide. One (1) tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting strip. Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet. For parking areas with twelve or more spaces eight percent (8%) of the vehicular use area must be designated for green space; this green space needs to be evenly distributed throughout the parking area(s). The minimum size of an interior landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty (150) or fewer parking spaces. Building landscape areas shall be provided between the vehicular use area used for public parking and the general vicinity of the building. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each forty (40) linear feet of vehicular use area abutting the building. A landscape irrigation system shall be required for developments of one (1) acre or larger. The City Beautiful Commission recommends preserving as many existing trees as feasible on this site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees of six (6) inch caliper or larger. C. Staff Analysis: The C-3/1-2 zoned property located at 1301 Rebsamen Park Road is occupied by two (2) commercial buildings and associated parking areas. The property is located on the east side of Rebsamen Park Road, north of Cantrell Road. The northernmost building was previously a Dixie Cafe restaurant. The south building is a one-story office building. Paved parking is located adjacent to and between the two (2) buildings. A private access road is located along the south property line. Access drives to the property are located along the Rebsamen Park Road and private driveway frontages. The applicant proposes to remove the two (2) buildings from the site and construct a new building for a bank facility, as noted on the attached site plan. The proposed OCTOBER 28, 2019 ITEM NO.: 7 (CON'T. Z-94 building will be located within the south half of the property. Paved parking will be located on the east, west and north sides of the building. One (1) driveway from Rebsamen Park Road and two (2) driveways from the private driveway along the south property line will serve as access to the property. A drive-thru canopy will be located on the south side of the building. The canopy structure will be located approximately 10.3 feet back from the south side property line. Section 36-320(e)(2) of the City's Zoning Ordinance requires a minimum side setback of 15 feet for this 1-2 portion of the overall property. Therefore, the applicant is requesting a variance to allow the drive-thru canopy portion of the building with a reduced side setback. Staff is supportive of the requested side setback variance. Staff views the request as reasonable. The requested side setback encroachment for the drive-thru portion of the overall building is very minor in nature. All other minimum building setbacks comply with ordinance standards. The building immediately to the south (across the private driveway) has a similar setback from its north side property line as the subject building. Therefore, the proposed side building setback will not be out of character with other building setbacks in the area. Staff believes the proposed drive-thru canopy with reduced side setback will have no adverse impact on the adjacent properties or the general area. D. Staff Recommendation: Staff recommends approval of the requested side setback variance, subject to compliance with the Public Works and Landscape and Buffer requirements as noted in paragraphs A. and B. of the agenda staff report. Board of Adjustment (October 28, 2019) The applicant was present. There were no objectors present. Staff presented the application with a recommendation of approval. There was no further discussion. The item was placed on the consent agenda and approved, as recommended by staff. The vote was 3 ayes, 0 noes and 2 absent. M