HomeMy WebLinkAboutZ-9455 Map 8ZONED
O-3 CUP
ZONED 0-3 i
I
I
I
RIP RAP TO CONTROL EROSION AT BASE
OUTLET PIPE
(APPROX 1.5 CY) \
I
I
I
CANOPY TREE,TYP
I
(N)
UNDERGROUND
POWER __]
ZONED
R2 TO BE ZONED
INDUSTRIAL BY
DEVELOPER IN FUTURE ss ss
K.11\ / 11111V1
T
ss EXISTING SEVER LIN s ss SS
NEW 8FT CHAIN LINK FENCE
/ WITH OPAQUE MATERIAL
-.._ _...- thlJ I IIWo IIALt I —
RIM ELEV - 321.01
CENTER LINE REMINGTON COVE 60'R/W F/L ELEV -315.0
NORTH
OVERALL SITE LAYOUT PLAN
" SCALE: 1"=20'
p L s 31012
lull,I:TE`.'- 0,1.,''S0UI.II
NV _ s - 1301EAS r..,.
— ss ss ss -
} (N) 20' MOTORIZED SLIDE GATE INSTALLED ON A
2'x2' CONC. PAD, MONITORING AND CONTROLS
TO BE SPECIFIED BY OWNER, CONTRACTOR TO
COORDINATE
! NEW SANITARTY SEWER
MANHOLE, TIE INTO EXISTING
LINE, FIELD DETERMINE
DEPTH
NO CURB EAST SIDE OF
DRIVE FOR FUTURE SHARED
DRIVE DEVELOPMENT
I
— (N) SECURITY KEYPAD
AND (N) KNOX BOX -
I
(N) CONC. CURB
EXISTING 15' UTILITY
EASMENT
EXISTING 37FT WIDE
CONCRETE APRON
EXISTING SEWER LINE
SITE PLAN NOTES
DEVELOMENT:
CURRENT ZONING:
PROPERTY AREA:
PROPERTY ADDRESS:
EPA - TALLEY ROAD
ADDITION
1-1
50,300 SQ. FT. /
1.156 ACRES
2 REMINGTON COVE,
LITTLE ROCK, AR.
SETBACKS:
- FRONT SETBACK:
70 FEET
- SIDE SETBACK:
30 FEET
- REAR SETBACK:
40 FEET (VARIANCE
REQ'D)
ACTUAL BUILDING AREA:
8,010 SQ. FT.
PARKING REQUIRED:
WAREHOUSE (1 / 2000 + 5)
= 4935 / 2000 = 2.46 + 5 = 7.46
8 SPACES
OFFICE (1 / 400)
= 3075 / 400 = 7.69
8 SPACES
PARKING PROVIDED:
16 SPACES
CALL BEFORE YOU
/� DIG - DRILL - BLAST
Y 1-800-482-8998
(TOLL FREE)
ARKANSAS ONE CALL SYSTEM, INC.
THE UTILITIES AS SHOWN ON THIS DRAWING
WERE DEVELOPED FROM THE INFORMATION
AVAILABLE, THIS IS NOT IMPLIED NOR INTENDED
TO BE THE COMPLETE INVENTORY OF UTILITIES
IN THIS AREA. IT IS THE CONTRACTORS
RESPONSIBILITY TO VERIFY THE LOCATION OF
ALL UTILITIES (WHETHER SHOWN OR NOT) AND
PROTECT SAID UTILITIES FROM ANY DAMAGE.
LEGEND
— — —
— BOUNDARY LINE
0
— EXISTING POWER POLE
®
— EXISTING SANITARY SEWER MANHOLE
e
— EXISTING WATER VALVE
— EXISTING WATER METER
3
— OVERHEAD POWER LINE
W
— UNDERGROUND WATER LINE
G
— EXISTING GAS LINE
(E)
— EXISTING
(N)
— NEW
FLOOD PLAIN STATEMENT:
NO PORTION OF THE PROPERTY SHOWN IS LOCATED
WITHIN THE 100-YEAR FLOOD PLAIN AS DESIGNED BY THE
FLOOD INSURANCE RATE MAP, PANEL NO. 05119C0434G,
PUBLISH BY THE FEDERAL EMERGENCY MANAGEMENT
AGENCY DATED JULY 6, 2015
LANDSCAPING:
LANDSCAPING IS THE RESPONSIBILITY OF OTHERS.
FINAL LANDSCAPING PLAN IS TO BE PROVIDED BY A
LANDSCAPE ARCHITECT TO CONFORM TO THE CITY OF
LITTLE ROCKS REQUIREMENTS.
NOTES:
ALL STREETS, WALKS, DRIVES, DRAINAGE
STRUCTURES, FENCES, UTILITIES, ETC,. THAT ARE
DISTRIBUTED INSIDE OR OUTSIDE THE PROPERTY LINE
SHALL BE RESTORED TO THEIR ORIGINAL CONDITION
OR BETTER AT THE CONTRACTORS EXPENSE.
CAUTION EXISTING SITE UTILITIES:
INFO WAS NOT FIELD VERIFIED. INFO WAS TAKEN FROM
DRAWING AND LIMITED MARKING ON THE GROUND.
N
1
T
s
BEARINGS ARE BASED ON ARKANSAS
STATE PLANE GRID NORTH DERIVED
FROM GPS OBSERVATIONS.
0 20 40 60
0 COPYRIGHT HERITAGE ENGINEERING PLLC 2019
ENGINEERING EXCELLENCE
Heritage
Engineering
PLLC
P.O. BOX 505
Benton, Arkansas 72018
(501)939-2303
FAX(501)939-2016
Z
Ir)
J
Z
m
Z
O
w
Q
U
o
�
o
F-
a
C)
3:
w
Zo
L:
O
z
co
U
Q
w
O
U
LL
w
LU
p
O
w
Z
w
J
W
W
HE JOB NO.:
2019-198
FILE NAME:
PLOT SCALE:
1:20
ISSUE DATE 1:
19 AUG 2019
ISSUE DATE 2:
ISSUE DATE 3:
WARNING
0 1/2 1
IF THIS BAR DOES NOT MEASURE
1" THEN DRAWING HASSBEENBEEN
REDUCED AND IS NOT TO SCALE
SCALE:
DESIGNED BY: EAW
DRAWN BY: EAW
CHECKED BY: EAW
SHEET No.