HomeMy WebLinkAboutZ-9419 Staff AnalysisMay 15, 2019
ITEM NO.: 13
NAME: Hamm Diesel Electric Short -form PD-C
LOCATION: 10,524 Helm Drive
Planning Staff Comments:
File No. Z-9419
1. Provide notification of the (abutting ro ert owners/ rfl ert owners within 200-feet
of the site) including the certified abstract list, notice form with affidavit executed and
proof of mailing. The notice must be mailed no later than May 22, 2019. The Office
of Planning and Development must receive the proof of notice no later than May 31,
2019.
2. Provide days and hours of operation
3. Locate dumpster and required screening.
4. Confirm there will be no outside storage of materials or merchandise.
5. Will any equipment such as compressors or generators be located outside?
6. Confirm signage will comply with that allowed in commercial zones.
7. Provide typical number of employees.
Variance/Waivers: none requested
Engineering Comments:
Public Works Conditions:
1. Mabelvale Main is classified on the Master Street Plan as a minor arterial. A dedication
of right-of-way 45 feet from centerline will be required. Show the centerline of the right-
of-way. At the building foot print, right-of-way should be dedicated to the exterior wall of
the building.
2. Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the private
improvements such as parking and sign pole located in the right-of-way.
Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority:
Sewer Available to this site. EAD Analysis Required
Entergy
ITEM NO.: 13 File No. Z-9419
Entergy does not object to this proposal. There does not appear to be any conflicts with
existing electrical utilities at this location. Contact Entergy in advance to discuss electrical
service requirements, or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comments received
AT & T: No comments received
Central Arkansas Water:
NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of
request for water service must be met.
Fire Department:
Full Plan Review
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a
hydrant. Where a fire hydrant is located on a fire apparatus access road, the minimum
road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not
exceed 10 percent in grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas
Fire Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings
or portions of buildings hereafter constructed shall be accessible to fire department
apparatus by way of an approved fire apparatus access road with an asphalt, concrete
or other approved driving surface capable of supporting the imposed load of fire
apparatus weighing at least 75,000 pounds.
Commercial and Industrial Developments — 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building or
facilities exceeding 30 feet or three stories in height shall have at least two means of fire
apparatus access for each structure.
ITEM NO.: 13
rile No. L-U41U
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or facilities
having a gross building area of more than 62,000 square feet shall be provide with two
separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square feet
that have a single approved fire apparatus access road when all building are
equipped throughout with approved automatic sprinkler systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they shall
be placed a distance apart equal to not less than one half of the length of the maximum
overall diagonal dimension of the lot or area to be served, measured in a straight line
between accesses.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of
the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-
end fire apparatus access roads in excess of 150 feet shall be provided with width and
turnaround provisions in accordance with Table D103.4. Requirements for Dead-end
fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access road
gates. Gates securing the fire apparatus access roads shall comply with all of the
following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices shall
be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or when
a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with UL
325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
ITEM NO.: 13
File No. Z-9419
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention
Code. Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull
501-377-1245) and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-
3757). Number and Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: no comments received
County Planning_ No comments received
Building Codes/Landscape:
Building Code:
Landscape: No comments.
Transportation/Planning:
Rock Region Metro: No comments
Planning Division- This request is located Otter Creek Planning District. The Land Use
Plan shows Mixed Use (MX) for this property. The Mixed Use Category provides for a
mixture of residential, office and commercial uses to occur. A Planned Zoning District is
required if the use is entirely office or commercial or if the use is a mixture of the three.
The applicant has applied for a rezoning from R-2 (Single -Family District) to PDC
(Planned Development Commercial) to use existing building for a business that a rebuild
and sell starters and alterations.
Master Street Plan: South of the property is Helm Drive and it is shown as a Local Street
on the Master Street Plan. West of the property is Mabelvale Main Street and it is shown
as a Minor Arterial on the Master Street Plan. The primary function of a Local Street is to
provide access to adjacent properties. Local Streets that are abutted by non-residential
zoning/use or more intensive zoning than duplexes are considered as "Commercial
Streets". A Collector design standard is used for Commercial Streets. A Minor Arterial
provides connections to and through an urban area and their primary function is to provide
short distance travel within the urbanized area. Entrances and exits should be limited to
minimize negative effects of traffic and pedestrians on Mabelvale Main Street since it is
a Minor Arterial. These streets may require dedication of right-of-way and may require
street improvements for entrances and exits to the site.
ITEM NO.: 13
File No. Z-9419
Bicycle Plan: A Class II Bike Lane is shown along Mabelvale Main Street. Bike Lanes
provide a portion of the pavement for the sole use of bicycles.
Revised plat/plan: Submit responses to staff issues and four (4) copies of a revised
preliminary plat/plan (to include the additional information as noted above) to staff on or
before May 22, 2019. If you have any questions please contact Dana Carney,
dcarney@littlerock.gov or 501.371.6817 or Jamie Collins, gcollins littlerock.gov or
501.371.6818.
FILE NO.: Z-941
NAME: Hamm Diesel Electric Short -form PD-C
LOCATION- 10,524 Helm Drive
DEVELOPER:
Shawn Furton
Hamm Diesel Electric
P. O. Box 1088
Mabelvale, AR 72103
OWNER/AUTHORIZED AGENT:
Timothy Helm/Owner
Shawn Furton/ Authorized Agent
SURVEYOR/ENGINEER:
Laha Engineers
6602 Baseline Rd., Suite E
Little Rock, AR 72209
AREA: .3 acres
WARD: 7
CURRENT ZONING:
ALLOWED USES:
PROPOSED ZONING
PROPOSED USE
NUMBER OF LOTS: 1 FT. NEW STREET: 0 LF
PLANNING DISTRICT: 15 CENSUS TRACT: 41.03
R-2
Single family (non -conforming commercial has been lost)
PD-C, planned development -commercial
Rebuild and sell starters and alternators; no vehicle
installation
VARIANCEM/AIVERS: None requested.
FILE NO.: Z-9419 (Cont.
BACKGROUND:
The commercial building on the site was constructed circa 1960 and was once occupied
by Helm's Grocery. The property was annexed into the City in 1979 and zoned R-2 single
family. There has not been an application to change the zoning since the annexation and
the building was occupied by commercial uses on and off over the years. The building
has been vacant for some time and the property has lost its non -conforming status.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is requesting approval of PD-C zoning to allow for use of the building
for Hamm Diesel electric, a small business that rebuilds and sells vehicle starters
and alternators. The business does not do any vehicle installation. The products
are sold to garages and businesses who perform installation. All work occurs inside
the building. There is no outside storage of materials or product. No changes to
the site or building, outside of what minor remodeling might be required inside the
building, are proposed.
B. EXISTING CONDITIONS:
The site is occupied by a one-story, commercial building and paved parking. The
property is located in an area of mixed zoning and uses. A multi -tenant commercial
building is located across Mabelvale Main to the west. Single family property,
neighborhood commercial and light industrial properties are located to the east.
The new Southwest Little Rock High School is being constructed farther to the
east. The main line railroad track is located across Helm Drive to the south. Single
family and a convenience store with gas pumps and a car wash are located to the
north.
C. NEIGHBORHOOD COMMENTS:
Notice of the public hearing was sent to all owners of properties located within
200 feet of the site and the SWLRUP and Mavis Circle neighborhood Associations.
D. ENGINEERING COMMENTS.
PUBLIC WORKS CONDITIONS:
1. Mabelvale Main is classified on the Master Street Plan as a minor arterial.
A dedication of right-of-way 45 feet from centerline will be required. Show the
centerline of the right-of-way. At the building foot print, right-of-way should be
dedicated to the exterior wall of the building.
2. Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818)
for the private improvements such as parking and sign pole located in the
right-of-way.
2
FILE NO.: Z-9419 (Cont.
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority:
Sewer Available to this site. EAD Analysis Required.
Entergy
Entergy does not object to this proposal. There does not appear to be any conflicts
with existing electrical utilities at this location. Contact Entergy in advance to
discuss electrical service requirements, or adjustments to existing facilities (if any)
as this project proceeds.
Centerpoint Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water:
NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time
of request for water service must be met.
Fire Department:
Full Plan Review
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall
not exceed 10 percent in grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
3
FILE NO.: Z-9419 (Cont.
Commercial and Industrial Developments — 2 means of access. - Maintain fire
apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1
Section D104.1 Buildings exceeding three stories or 30 feet in height. Building
or facilities exceeding 30 feet or three stories in height shall have at least two
means of fire apparatus access for each structure.
Section D104.2 Building exceeding 62,000 square feet in area. Buildings or
facilities having a gross building area of more than 62,000 square feet shall be
provide with two separate and approved fire apparatus access roads.
Exception: Projects having a gross building area of up to 124,000 square
feet that have a single approved fire apparatus access road when all
building are equipped throughout with approved automatic sprinkler
systems.
D104.3 Remoteness. Where two fire apparatus access roads are required, they
shall be placed a distance apart equal to not less than one half of the length of the
maximum overall diagonal dimension of the lot or area to be served, measured in
a straight line between accesses.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
4
FMV:rk [0]WA&9 1LONI "OT,9
7. Locking device specifications shall be submitted for approval by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with UL
325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office
(Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as
per Table C105.1.
Parks and Recreation: No comments received.
County Planninq: No comments received-
F. BUILDING CODES/LANDSCAPE:
Building Code:
Landscap : No comments.
G. TRANSPORTATION/PLANNING-
Rock Region Metro: No comments
Planning Division: This request is located Otter Creek Planning District. The Land
Use Plan shows Mixed Use (MX) for this property. The Mixed Use Category
provides for a mixture of residential, office and commercial uses to occur. A
Planned Zoning District is required if the use is entirely office or commercial or if
the use is a mixture of the three. The applicant has applied for a rezoning from
R-2 (Single -Family District) to PDC (Planned Development Commercial) to use
existing building for a business that a rebuild and sell starters and alterations.
Master Street Plan: South of the property is Helm Drive and it is shown as a Local
Street on the Master Street Plan. West of the property is Mabelvale Main Street
and it is shown as a Minor Arterial on the Master Street Plan. The primary function
of a Local Street is to provide access to adjacent properties. Local Streets that are
abutted by non-residential zoning/use or more intensive zoning than duplexes are
considered as "Commercial Streets". A Collector design standard is used for
Commercial Streets. A Minor Arterial provides connections to and through an
urban area and their primary function is to provide short distance travel within the
urbanized area. Entrances and exits should be limited to minimize negative effects
5
FILE NO.: Z-9419 Cont.
of traffic and pedestrians on Mabelvale Main Street since it is a Minor Arterial.
These streets may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Mabelvale Main Street. Bike
Lanes provide a portion of the pavement for the sole use of bicycles.
Revised plat/plan: Submit responses to staff issues and four (4) copies of a
revised preliminary plat/plan (to include the additional information as noted
above) to staff on or before May 22, 2019. If you have any questions please contact
Dana Carney, dcarneyP,Iittlerock. go_v or 501.371.6817 or Jamie Collins,
gcollins(cD_Iittlerock.gov or 501.371.6818.
H. SUBDIVISION COMMITTEE COMMENT:
(May 15, 2019)
The applicant was present. Staff presented the item and noted some additional
information was needed. The applicant was asked to provide the days and hours
of operation and the number of employees. The applicant was advised to locate
the dumpster and required screening on the site plan and to confirm there will be
no outside storage of materials or merchandise. Staff asked if any equipment such
as compressors or generators would be located outside. The applicant was asked
to confirm that signage would comply with that allowed in commercial zones.
Pubic Work's comments were presented. Staff discussed the requirement to
dedicate right of way and the process to obtain a franchise for the parking and sign
currently in the right of way.
Comments from the other departments and reviewing agencies were noted. The
applicant was advised to respond to staff issues by May 22, 2019. The committee
forwarded the item to the full commission.
ANALYSIS -
The applicant is requesting approval of PD-C zoning to allow Hamm Diesel and
Electric, a small business that rebuilds and sells vehicle starters and alternators,
to occupy the non -conforming commercial building located on this site. No vehicle
installation occurs on the site. The products are sold to garages and businesses
who perform installation.
The applicant submitted responses to issues raised at subdivision committee.
Employees will consist of the applicant plus two others. Days and hours of
operation are Monday — Friday, 7:30 am — 4:30 pm. The applicant states the
dumpster will be enclosed by a wood privacy fence. Staff will work with the
applicant regarding placement of a dumpster as it is currently proposed to be
located at the southwest corner. Staff would prefer to see the dumpster located
away from the street perimeter. There will be no outside storage of materials and/or
merchandise on the property. There will be no equipment such as compressors or
R
FILE NO.: Z-9419 Cont.
generators located on the exterior of the building. Signage will comply with that
allowed in commercial zones. Right of way will be dedicated and a franchise
sought for the parking and sign pole in the existing right of way.
To staff's knowledge, there are no outstanding issues. Reuse of this existing
commercial building as proposed seems to staff to be an appropriate use.
J. STAFF RECOMMENDATION:
Staff recommends approval of the PD-C subject to compliance with the comments
and conditions outlined in paragraphs D, E and F and the staff analysis in the
agenda staff report.
PLANNING COMMISSION ACTION: (JUNE 6, 2019)
The applicant was present. There were no registered objectors present. Staff presented
the item and a recommendation of approval as outlined in the "staff recommendation"
above. There was no further discussion. The item was placed on the consent agenda
and approved as recommended by staff, including all staff comments and conditions. The
vote was 8 ayes, 0 noes and 3 absent.