HomeMy WebLinkAboutZ-9409 Staff AnalysisFILE NO.: Z-9409
NAME: Fletcher Ridge Long -form PRD
LOCATION: North side of Kanis Road, west of Chenal Downs Blvd.
DEVELOPER:
Potlatch/Deltic
7 Chenal Club Blvd.
Little Rock, AR 72223
OWNER/AUTHORIZED AGENT:
Potlatch/Deltic/Owner
White-Daters and Associates/authorized agent
SURVEYOR/ENGINEER:
White-Daters and Associates
24 Rahling Circle
Little Rock, AR 72223
AREA: 52 acres NUMBER OF LOTS: 205 FT. NEW STREET: 7,450 LF
WARD: 5 PLANNING DISTRICT: 21 CENSUS TRACT: 42.02
CURRENT ZONING: R-2
ALLOWED USES: Single Family
PROPOSED ZONING: PRD
PROPOSED USE: Single Family
VARIANCE/WAIVERS:
1. Advance grade entire project with 1st Phase development
BACKGROUND:
This property was zoned R-2 with the extension of the City's extraterritorial zoning to this
area in 1990. This property was annexed into the city on August 20, 2018 through the
passage of Ordinance NO. 21.615.
FILE NO.: Z-9409 Cont.
A. PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicants are requesting approval of PRD zoning for this 52 +/- acre property
to allow for the phased development of a single family residential subdivision
containing 205 lots, 6 tracts and 6,910 linear feet of new public street. The project
will be developed in five phases. A variance is requested to allow for advance
grading of the entire site in conjunction with development of the first phase. The
average lot size is 50' x 110'. The proposed density is 3.92 lots per acre. The lots
are proposed to have front and rear setbacks of 20 feet and side yard setbacks of
5 feet. 15.99 of the 52 acres, or roughly 31 %, are proposed to be common open
space and buffers.
The applicant proposes to dedicate right-of-way as required for Kanis Road. A
roundabout is proposed at Kanis Road/Chenal Downs Blvd. and the planned
entrance into the proposed new subdivision. The applicant is proposing to do any
required Master Street Plan improvements to Kanis Road. The Master Street Plan
establishes an alternative design standard for this portion of Kanis of paving with
22 feet and two 4-foot gravel shoulders east of Chenal Downs Blvd. and two, 10.5'
lanes with no shoulders west of Chenal Downs Blvd.. A secondary emergency/Fire
Department access road is shown at the north perimeter of the subdivision, tying
into Wildwood Place Subdivision which is developing to the north.
B. EXISTING CONDITIONS:
The site is undeveloped and wooded. New subdivisions are developing adjacent
to the north. The lot sizes in those subdivisions are similar to those proposed
under this application. A development of single family homes on five acre tracts is
located across Kanis Road to the south. Undeveloped timberland, also owned by
this applicant, extends to the west. Single family homes on larger lots are located
to the east.
C. NEIGHBORHOOD COMMENTS:
Notice of the public hearing was sent to all owners of properties located within 200
feet of the site and the Chenal Downs, and Citizens of West Pulaski County
Neighborhood associations.
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
Kanis Road is classified on the Master Street Plan as a minor arterial with a
special design standard. A dedication of right-of-way 45 feet from centerline
will be required.
2. With site development, provide design of street conforming to the Master
Street Plan. Construct one-half street improvement to Kanis Road with
planned development. Per the MSP, one half street improvements to Kanis
2
FILE NO.: Z-9409 (Cont.)
Road east of Chenal Downs Blvd consists of a 10.5 ft. travel lane and no
shoulder and Kanis Road west of Chenal Downs Blvd consists of an 11ft
travel lane with a 4ft gravel shoulder.
3. The MSP defines a minor residential street as: (a) a cul-de-sac street not
exceeding 40 lots, or (b) a loop street not exceeding 80 lots, and (c ) and in
no case generating more than 400 trips per day with the assumption of ten
vehicles trips per day per lot. Fletcher Ridge Place, Fletcher Ridge Drive,
Fletcher Ridge Lane, and Fletcher Creek Drive do not meet minor residential
street standards. Variances are required to be obtained for the minimum
right-of-way widths and absence of sidewalks.
4. The Kanis Road round -a -bout should be constructed with exterior class 3
curb and gutter, mountable interior curb, islands, signage, striping, and
consideration for future pedestrian crossing capabilities in conformance with
AASHTO and MUTCD standards. The proposed entry street design from
Fletcher Ridge cannot be approved for a round -a -bout. Contact Nat Banihatti
at 379-1818 for additional information. What is proposed in the center of the
round -a -bout?
5. Street names and street naming conventions must be approved by Public
Works. Fletcher Ridge Lane is the 4th repeat of the same street name with
houses located on that street. Typically, no more than 3 streets with the same
name with houses located on that street is approved. A different street name
should be provided. Will the entrance street off Kanis Road be given a
different street name or is it proposed to be Fletcher Ridge Circle or Chenal
Downs Blvd.? Contact Glenn Haley at (501) 371-4537 for more information.
6. A grading permit in accordance with section 29-186 (c) & (d) will be required
prior to any land clearing or grading activities at the site. Other than
residential subdivisions, site grading and drainage plans must be submitted
and approved prior to the start of grading activities. An variance is being
requested to advance grade the entire subdivision with the issuance of a
grading permit for
7. Provide a sketch grading and drainage plan. Determine if strips of tract land
should be provided for the installation of drainage improvements.
8. Storm water detention ordinance applies to this property. Maintenance of the
detention pond and all private drainage improvements is the responsibility of
the developer and/or POA. Show on plan the locations of access to the
detention ponds from the public right-of-way for future maintenance.
9. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from
the Arkansas Department of Environmental Quality prior to the start of
construction.
10. Street Improvement plans shall include signage and striping. Public Works
must approve completed plans prior to construction.
11. Hauling of fill material on or off site over municipal streets and roads requires
approval prior to a grading permit being issued. Contact Public Works Traffic
3
E
.: Z-9409 (Cont.
Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more
information.
12. Street lights are required by Section 31-403 of the LR code. Provide plans
for approval to Traffic Engineering. Street lights must be installed prior to
platting/certificate of occupancy. Contact Traffic Engineer 379-1813 (Greg
Simmons) for more info.
13. USPS cluster box units should be placed in conformance with USPS and City
of Little Rock policy design standards. All mail kiosk must be constructed to
be ADA accessible. Sidewalks are not shown adjacent to kiosks on Fletcher
Ridge Drive.
14. Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818)
for the private improvements located in the right-of-way.
15. Alteration of the water course will require approval from the Little Rock District
of the US Army Corps of Engineers prior to start of work.
16. Traffic calming devices are required for long straight streets to discourage
speeding that exceed 900 ft as suggested by MUTCD. Traffic circles,
pedestrian tables or round -a -bouts are suggested at regular intervals and at
main intersections. Staff suggests pedestrian tables be installed at mail kiosk
locations and adjacent to tract land. Contact Travis Herbner, Traffic Engineer
at 379-1805 for additional info.
17. Damage to public and private property due to hauling operations or operation
of construction related equipment from a nearby construction site shall be
repaired by the responsible party prior to issuance of a certificate of
occupancy.
18. A minimum undisturbed strip 25 ft. wide except for reasonable access shall
be provided along each side of streams having a 10 yr storm >150 cfs unless
approval to vary has been obtained from the USCOE. The undisturbed strip
should be measured from the top of the bank.
19. All public drainage easements must be unobstructed and access provided to
the public right-of-way by constructed infrastructure and/or documented on
the final plat.
20. All public drainage easements must contain drainage infrastructure approved
by the City of Little Rock Public Works Department.
21. 100 year overflow swales must be constructed and placed within public
drainage easements.
UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Autho
Sewer main extension required with easements if new sewer service is required
for this project. LRWRA Commission Approval and Zero Capacity Fee Required
if pumping out of sewer basin.
4
FILE NO.: Z-9409 Cont.
Entergy
Entergy does not object to this proposal. There do not appear to be any conflicts
with existing electrical utilities at this location. There is an existing three phase,
overhead power line along Kanis Road just to the east which may need to be
extended to serve this development. Contact Entergy in advance to discuss
electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
Centerpoint Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water:
Sewer main extension required with easements if new sewer service is required
for this project. LRWRA Commission Approval and Zero Capacity Fee Required
if pumping out of sewer basin.
Fire Department:
Full Plan Review
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall
not exceed 10 percent in grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
5
FILE NO.: Z-9409 (Cont.
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one
person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with
U L 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two -Family dwelling residential developments. Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
R
FILE NO.: Z-9409 (Co
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office
(Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as
per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODESILANDSCAPE:
Building Code:
Second / emergency fire access required before 30th occupancy can take place.
Consult with Fire Marshal's Office for further review.
Landscape: No comments.
G. TRANSPORTATION/PLANNING:
Rock Region -Metro: No comments received.
Plannina Division.
This request is located in Burlingame Valley Planning District. The Land Use Plan
shows Residential Low Density (RL) for this property. The Residential Low Density
is for single-family homes at densities no greater than six dwelling units per acre.
Such residential development is typically characterized by conventional single
family homes, but may also include patio or garden homes and cluster homes,
provided that the density remain less than 6 units per acre. The applicant has
applied for rezoning from R-2 (Single Family District) to PRD (Planned Residential
District) to allow for future development of a single family subdivision in 5 phases
Master Street Plan: South of the property is Kanis Road are shown as Minor
Arterial on the Master Street Plan. A Minor Arterial provides connections to and
through an urban area and their primary function is to provide short distance travel
within the urbanized area. Entrances and exits should be limited to minimize
negative effects of traffic and pedestrians on Kanis Road since it is a Minor Arterial.
This street may require dedication of right-of-way and may require street
improvements for entrances and exits to the site.
7
FILE NO.: Z-9409 Cont.
Bicycle Plan: A Class II Bike Lane is shown along Kanis Road. Bike Lanes provide
a portion of the pavement for the sole use of bicycles.
Revised plat/plan: Submit responses to staff issues and four (4) copies of a
revised preliminary plat/plan (to include the additional information as noted
above) to staff on or before April 10, 2019. If you have any questions please
contact Dana Carney, dcarne littlerock. ❑v or 501.371.6817 or Jamie Collins,
gcollins(cD-littlerock.goov or 501.371.6818.
H. SUBDIVISION COMMITTEE COMMENT:
(April 3, 2019)
The applicants were present. Staff presented the item and noted some additional
information was needed. Staff asked the applicants to confirm the percentage of
open space in the general notes as the information appeared to be incorrect. Staff
requested the maximum building height and some information on the proposed
architectural style of the houses; exterior finish and roofing. Staff asked if fencing
would be permitted as per typical residential properties. The applicants were asked
to describe the treatment of the proposed landscape easement along Kanis Road
and to confirm that the 75' wooded buffer along Kanis Road would remain
undisturbed. Staff asked what portions of tract F wrapping around the north, west
and east perimeters would remain undisturbed. The applicants were asked to
indicate the location and size of any proposed subdivision sign.
Staff noted the requested variances to allow advance grading of the entire site in
conjunction with the first phase of construction and to allow a reduced standard of
half -street improvements to Kanis Road.
Public Works comments were presented and discussed. Several comments were
discussed in detail. Staff commented that several proposed streets were indicated
as minor residential although they do not meet the Master Street Plan criteria for
a minor residential street. Staff stated variances would have to be requested for
those streets, including the absence of sidewalks. Staff requested a sketch grading
and drainage plan. Staff stated traffic calming devices were required for long
straight streets. Staff suggested pedestrian tables be installed at mail kiosk
locations and adjacent to tract land. Staff added the following additional comment:
For the areas of the proposed development suspected to be flood prone and that
area is not covered by the flood insurance study prepared by the federal insurance
administration for the national flood insurance program, or is not covered by
available U. S. Army Corps of Engineers information, provide an engineering
analysis to determine to the best of the engineer's ability safe building lines on the
preliminary plat.
Staff stated there was an area on the west perimeter of the site where such an
analysis was needed.
FILE NO.: Z-9409 (Cont.
Staff noted a secondary emergency access to be approved by the Fire Marshall
would have to be installed with the first phase since it exceeded 30 dwelling units.
Comments from the other departments and reviewing agencies were noted. The
applicants were advised to respond to staff issues by April 10, 2019. The
committee forwarded the item to the full commission.
ANALYSIS. -
The applicant submitted responses to issues raised at subdivision committee. The
maximum building height will be 35 feet, as per the R-2 district. Design guidelines
will be similar to Wildwood Place located adjacent to the north. That development
requires exterior finishes of brick or stone with pitched/shingled roof. Minimum
house size will be set by the bill of assurance and design standards will be
overseen by an architectural review committee. Fencing will be included in those
guidelines but will not exceed the height limits allowed by code for residential
districts. The 25 foot landscape easement along Kanis Road will typically remain
undisturbed. Its purpose is to allow construction of a fence or other architectural
feature generally along Kanis Road. The applicant states a similar easement exists
along the south side of Kanis Road in this area. The 75 foot buffer along Kanis will
remain undisturbed. While none are planned at present, utility companies may find
it necessary to install underground utilities across the buffer. These crossings
would be limited as to impact and oriented to minimize the removal of trees and
the visual impact of the installation. Only small areas of Tract F which wraps around
the north, east and west premiers of the plat will remain undisturbed. A single
subdivision identification sign is proposed at the entrance. It will be 6 feet in height
and 32 square feet in area.
Staff has the following comments in response to the applicant's resubmittal.
A street name must be provided for the entrance street off of Kanis. A Master
Street Plan variance is required for a residential street (Fletcher Ridge Circle) to
be constructed with a minor residential right-of-way of 45 ft. in width. A Master
Street Plan variance is required for a portion of a residential street (Fletcher Ridge
Circle) to not be constructed with sidewalks. Kanis Road round -a -bout must be
constructed in consideration for future pedestrian access, with curb and gutter,
with street lights installed in all four corners, and constructed in conformance with
AASHTO and MUTCD standards. The proposed subdivision sign must be located
no closer than 30 ft. from the south end of the round -a -bout directional median to
not deter sight distance. The engineering analysis has been provided and is being
reviewed by staff. Findings will be provided.
J. STAFF RECOMMENDATION:
Staff's recommendation is forthcoming.
E
FILE NO.: Z-9409 (Cont.
PLANNING COMMISSION ACTION: (APRIL 25, 2019)
The applicants were present. There were no registered objectors present. Staff informed
the commission that they had completed their review and there were no outstanding
issues. All sidewalks will be 5 ft. in width, where required. There are no Master Street
Plan variances required for right-of-way width or street design. The Kanis Road round -
a -bout will be constructed in consideration for future pedestrian access, with curb and
gutter, with street lights installed in all four corners and constructed in conformance with
AASHTO and MUTCD standards. An access easement must be provided for the
secondary and emergency access from this subdivision, through the Potlatch/Deltic
property, through Tract O of Wildw- ood Place Phase VII to the Wildcreek Circle right-of-
way. The subdivision sign is to be placed no closer than 30 ft. from the south end of the
round -a -bout median. The drainage analysis has been reviewed and found to be
sufficient.
Staff read into the record a statement from the Citizens of West Pulaski County described
as a position statement on Fletcher Ridge PRD. The applicant had stated they did not
object to that statement being presented. The statement read as follows:
"The Citizens of West Pulaski County's expanded steering committee understands the
City of Little Rock will grow into the western part of Pulaski County and wishes to see that
growth be done in ways that will preserve the character of the area.
The CWPC committee and other community leaders have met several times with
representatives of Potlatch/Deltic and its subsidiaries regarding a proposed development
on Kanis Road across from Chenal Downs. While this should not be taken as an objection
to the plan, there were 3 concerns expressed as follows: the density of the proposal (3.92
lots per acre) as it bears on the expected increase in traffic on Kanis Road; the proposal
appears inconsistent with the character of the area; concern about the effect the plan will
have on Fletcher's Hollow (2 miles on Kanis Road form Chenal Downs entry to Walnut
Grove Road).
CWPC hopes to constructively work with Potlatch/Deltic in the future to preserve the
character of the area, including Fletcher's Hollow."
Staff recommended approval of the item subject to compliance with all comments and
conditions presented and as outlined in paragraphs D, E and F and the staff analysis in
the agenda staff report. There was no further discussion. The item was placed on the
consent agenda and approved as recommended by staff. The vote was 10 ayes, 0 noes
and 1 absent.
10
ITEM NO.: 18
NAME: Fletcher Ridge Long -form PRD
LOCATION: North side of Kanis road, west of Chenal Downs Blvd.
Planning Staff Comments:
File No. Z-9409
1. Provide notification of the (abutting property owners&operty owners within 200-feet of the
site) including the certified abstract list, notice form with affidavit executed and proof of
mailing. The notice must be mailed no later than April 10, 2019. The Office of Planning
and Development must receive the proof of notice no later than April 19, 2019.
2. Confirm percentage of open space in general notes; indicated at 3.27%.
3. Provide maximum building height.
4. Provide some information on proposed architectural style of houses; exterior finish and
roofing.
5. Will fencing be permitted as per typical residential?
6. Describe treatment of 25' landscape easement along Kanis.
7. Confirm that 75' wooded buffer along Kanis is to remain undisturbed.
8. Indicate what portions of Tract F wrapping around the north, east and west perimeters will
remain undisturbed.
9. Indicate location and size of subdivision sign.
Variance/Waivers:
1. Advance grade the entire site with first phase
2. Variance from Boundary Street required improvements to Kanis Road
Engineering Comments:
lic Works Conditions:
1. Kanis Road is classified on the Master Street Plan as a minor arterial with a special
design standard. A dedication of right-of-way 45 feet from centerline will be required.
2. With site development, provide design of street conforming to the Master Street Plan.
Construct one-half street improvement to Kanis Road with planned development. Per
the MSP, one half street improvements to Kanis Road east of Chenal Downs Blvd
consists of a 10.5 ft travel lane and no shoulder and Kanis Road west of Chenal Downs
Blvd consists of an 11ft travel lane with a 4ft gravel shoulder.
3. The MSP defines a minor residential street as: (a) a cul-de-sac street not exceeding 40
lots, or (b) a loop street not exceeding 80 lots, and (c ) and in no case generating more
than 400 trips per day with the assumption of ten vehicles trips per day per lot. Fletcher
Ridge Place, Fletcher Ridge Drive, Fletcher Ridge Lane, and Fletcher Creek Drive do
not meet minor residential street standards. Variances are required to be obtained for
the minimum right-of-way widths and absence of sidewalks.
ITEM NO.: 18 File No. Z-9409
4. The Kanis Road round -a -bout should be constructed with exterior class 3 curb and
gutter, mountable interior curb, islands, signage, striping, and consideration for future
pedestrian crossing capabilities in conformance with AASHTO and MUTCD standards.
The proposed entry street design from Fletcher Ridge cannot be approved for a round -
a -bout. Contact Nat Banihatti at 379-1818 for additional information. What is proposed
in the center of the round -a -bout?
5. Street names and street naming conventions must be approved by Public Works.
Fletcher Ridge Lane is the 4th repeat of the same street name with houses located on
that street. Typically, no more than 3 streets with the same name with houses located
on that street is approved. A different street name should be provided. Will the entrance
street off Kanis Road be given a different street name or is it proposed to be Fletcher
Ridge Circle or Chenal Downs Blvd.? Contact Glenn Haley at (501) 371-4537 for more
information.
6. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any
land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of grading
activities. An variance is being requested to advance grade the entire subdivision with
the issuance of a grading permit for
7. Provide a sketch grading and drainage plan. Determine if strips of tract land should be
provided for the installation of drainage improvements.
8. Storm water detention ordinance applies to this property. Maintenance of the detention
pond and all private drainage improvements is the responsibility of the developer and/or
POA. Show on plan the locations of access to the detention ponds from the public right-
of-way for future maintenance.
9. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
10. Street Improvement plans shall include signage and striping. Public Works must
approve completed plans prior to construction.
11. Hauling of fill material on or off site over municipal streets and roads requires approval
prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621
S. Broadway, (501) 379-1805 (Travis Herbner) for more information.
12. Street lights are required by Section 31-403 of the LR code. Provide plans for approval
to Traffic Engineering. Street lights must be installed prior to platting/certificate of
occupancy. Contact Traffic Engr 379-1813 (Greg Simmons) for more info.
13. USPS cluster box units should be placed in conformance with USPS and City of Little
Rock policy design standards. All mail kiosk must be constructed to be ADA accessible.
Sidewalks are not shown adjacent to kiosks on Fletcher Ridge Drive.
14.Obtain a franchise agreement from Public Works (Bennie Nicolo, 371-4818) for the
private improvements located in the right-of-way.
15.Alteration of the water course will require approval from the Little Rock District of the US
Army Corps of Engineers prior to start of work.
16.Traffic calming devices are required for long straight streets to discourage speeding that
exceed 900 ft as suggested by MUTCD. Traffic circles, pedestrian tables or round -a -
bouts are suggested at regular intervals and at main intersections. Staff suggests
pedestrian tables be installed at mail kiosk locations and adjacent to tract land. Contact
Travis Herbner, Traffic Engr. At 379-1805 for additional info.
ITEM NO.: 18
File No. Z-9409
17. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
18.A minimum undisturbed strip 25 ft wide except for reasonable access shall be provided
along each side of streams having a 10 yr storm >150 cfs unless approval to vary has
been obtained from the USCOE. The undisturbed strip should be measured from the
top of the bank.
19.All public drainage easements must be unobstructed and access provided to the public
right-of-way by constructed infrastructure and/or documented on the final plat.
20. All public drainage easements must contain drainage infrastructure approved by the City
of Little Rock Public Works Department.
21.100 year overflow swales must be constructed and placed within public drainage
easements.
Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority:
Sewer main extension required with easements if new sewer service is required for this project.
LRWRA Commission Approval and Zero Capacity Fee Required if pumping out of sewer basin.
Entergy:
Entergy does not object to this proposal. There do not appear to be any conflicts with existing
electrical utilities at this location. There is an existing three phase, overhead power line along
Kanis Road just to the east which may need to be extended to serve this development. Contact
Entergy in advance to discuss electrical service requirements, or adjustments to existing
facilities (if any) as this project proceeds.
Centerpoint Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water:
Sewer main extension required with easements if new sewer service is required for this project.
LRWRA Commission Approval and Zero Capacity Fee Required if pumping out of sewer basin.
Fire Department'.
Full Plan Review
Maintain Access:
ITEM NO.: 18 File No. Z-9409
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant.
Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall
be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent
in grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions
of buildings hereafter constructed shall be accessible to fire department apparatus by way of
an approved fire apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at least 75,000
pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire
apparatus access roads in excess of 150 feet shall be provided with width and turnaround
provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access
roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing
the fire apparatus access roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces
or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire department
personnel for emergency access. Emergency opening devices shall be approved by the
fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless
they are capable of being opened by means of forcible entry tools or when a key box
containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to
comply with requirements of ASTM F 2200.
ITEM NO.: 18
File No. Z-9409
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or
Two -Family dwelling residential developments. Developments of one- or two-family
dwellings where the number of dwelling units exceeds 30 shall be provided with two separate
and approved fire apparatus access roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private fire
apparatus access road and al dwelling units are equipped throughout with an
approved automatic sprinkler system in accordance with Section 903.3.1.1,
903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall
not be required.
2. The number of dwelling units on a single fire apparatus access road shall not be
increased unless fire apparatus access roads will connect with future development,
as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code.
Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245)
and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757). Number and
Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
Building Codes/Landscape:
Building Code:
Second / emergency fire access required before 30t" occupancy can take place. Consult with
Fire Marshals office for further review.
Landscape: No comments.
Transportation/Planning:
Rock Region Metro: No comments received.
Planning Division:
This request is located in Burlingame Valley Planning District. The Land Use Plan shows
Residential Low Density (RL) for this property. The Residential Low Density is for single-family
homes at densities no greater than six dwelling units per acre. Such residential development
is typically characterized by conventional single family homes, but may also include patio or
ITEM NO.: 18
File No. Z-9409
garden homes and cluster homes, provided that the density remain less than 6 units per acre.
The applicant has applied for rezoning from R-2 (Single Family District) to PRD (Planned
Residential District) to allow for future development of a single family subdivision in 5 phases
Master Street Plan: South of the property is Kanis Road are shown as Minor Arterial on the
Master Street Plan. A Minor Arterial provides connections to and through an urban area and
their primary function is to provide short distance travel within the urbanized area. Entrances
and exits should be limited to minimize negative effects of traffic and pedestrians on Kanis
Road since it is a Minor Arterial. This street may require dedication of right-of-way and may
require street improvements for entrances and exits to the site.
Bicycle Plan: A Class II Bike Lane is shown along Kanis Road. Bike Lanes provide a portion of
the pavement for the sole use of bicycles.
Revised plat/plan. Submit responses to staff issues and four (4) copies of a revised
preliminary plat/plan (to include the additional information as noted above) to staff on or before
April 10, 2019. if you have any questions please contact Dana Carney, dcarne littlervck. ov
or 501.371.6817 or Jamie Collins, gcollins@littlergck.gov or 501.371.6818.
DRAINAGE REPORT
FLETCHER RIDGE
LITTLE ROCK, AR
April 15, 2019
GENERAL BACKGROUND
Fletcher Ridge is a 52 acre Planned Residential Development on the North side of Kanis Road. Chenal
Downs, a 5 acre tract development is located on the South side of Kanis Road across from the PRD. The
area to be occupied by single family homes will be graded as part of the initial development of the
subdivision. When complete the site will generally slope from the SE corner to the NW corner.
After development none of the lots will be "flood prone".
SIGNIFICANT DRAINAGE FEATURES
An unnamed tributary to Fletcher Creek (UT-2) flows westerly along the North side of Kanis Road
adjacent to the PRD and then northerly along the west side of the PRD. When UT-2 is located on this
PRD/Preliminary Plat it is entirely within Tract A. Where UT-2 flows northwesterly from this PRD it drains
approximately 54.7 acres. Looking down stream, the left channel bank is relatively flat with the right
channel bank sloping rapidly up. Pictures of UT-2 are attached.
ANALYSIS
With a total drainage are of only 54.7 acres the Rational method is acceptable for a determination of
peak flow rates.
Q=(c) x (i) x (A) Q=Discharge (cubic feet per second)
1=Rainfall Intensity based on Tc (time of concentration)
A=Drainage Area (acres)
Conservatively use a time of concentration of 20 minutes and a 100 year event i=6.9
Conservatively use a runoff coefficient of 0.55
Therefore Q=(0.55) x (6.9) x (54.7) = 207 cfs
With this flow rate the attached calculations show a conservative depth of flow of 2.5 feet during the
100 year event.
RECOMMENDATION
All structures shall be located a minimum of 5 feet above (based on existing ground elevations) the
adjacent top of bank elevation and a minimum of 25 feet from the edge of the flow channel. No
structures shall be constSucted in Tract A.
n&.-bTimrs, P.E.
110)IN
;L ' 105033 � s
..
r{�J,