HomeMy WebLinkAboutZ-9407 Staff AnalysisITEM NO.: 16
File No. Z-9407
NAME: Village at the gateway Long -form PRD
LOCATION: west of the existing Village at the Gateway, 4 blocks west of Vimy Ridge Rd,
Planning Staff Comments:
1. Provide notification of the (abutting property owners/property owners within 200-feet of the
site) including the certified abstract list, notice form with affidavit executed and proof of
mailing. The notice must be mailed no later than April 10, 2019. The Office of Planning
and Development must receive the proof of notice no later than April 19, 2019.
2. Provide agent authorization.
3. Provide linear feet of new street.
4. Provide a phasing plan and indicate such on the proposed plan.
5. Proposed open space is 8 %. Should be 10-15% as common usable open space.
6. Provide some description of the proposed exterior of the proposed structures; materials,
roof design...
7. Locate and describe any proposed fencing.
8. Describe dumpster screening materials. Dumpster service hours should be limited to 7 a.m.
— 6 p. m. Monday — Friday.
9. Where is the management office located?
10. What is the proposed ownership plan for the development? Can individual lots be sold?
Variance/Waivers:
Advance grading
Engineering Comments:
Public Works Conditions:
1. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. Maximum residential driveway width is 20
ft.
2. Backing out into public streets is not permitted due to safety concerns for any
development other than R-2.
3. Currently, waste is being collected privately. Does the owner plan to vary from the
private service with this revision?
4. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any
land clearing or grading activities at the site. Other than residential subdivisions, site
grading and drainage plans must be submitted and approved prior to the start of
construction. Is a variance being requested to advance grade future phases? What is
the proposed timing or trigger for the advance grading activities?
ITEM NO.: 16 File No. Z-9407
5. Storm water detention ordinance applies to this property. Show the proposed location
for stormwater detention facilities on the plan. Maintenance of the detention pond and
all private drainage improvements is the responsibility of the developer and/or land
owner.
6. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the
Arkansas Department of Environmental Quality prior to the start of construction.
7. Hauling of fill material on or off site over municipal streets and roads requires approval
prior to a grading permit being issued. Contact Public Works Traffic Engineering at 621
S. Broadway, (501) 379-1805 (Travis Herbner) for more information.
8. Damage to public and private property due to hauling operations or operation of
construction related equipment from a nearby construction site shall be repaired by the
responsible party prior to issuance of a certificate of occupancy.
9. Staff understands no changes are proposed to the previously approved street and
drainage plans. Are any changes proposed?
Utilities/Fire Department/Parks/County Planning:
Little Rock Water Reclamation Authority:
Sewer main extension required with easements if new sewer service is required for this project.
Capacity Fee Analysis required.
Entergy:
Entergy does not object to this proposal. There do not appear to be any conflicts with existing
electrical utilities at this location. There is an existing underground power line in this area
serving existing developments in the subdivision to the east. Contact Entergy in advance to
discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
Centerpoint Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water:
All Central Arkansas Water requirements in effect at the time of request for water service must
be met.
A water main extension will be needed to provide water service to this property.
Please submit plans for water facilities to Central Arkansas Water for review. Plan revisions
may be required after additional review. Contact Central Arkansas Water regarding procedures
for installation of water facilities. Approval of plans by Central Arkansas Water, the Arkansas
Department of Health Engineering Division and Little Rock Fire Department is required.
ITEM NO.: 16
File No. Z-9407
Additional fire hydrant(s) will be required. Contact the Little Rock Fire Department to obtain
information regarding the required placement of the hydrant(s) and contact Central Arkansas
Water regarding procedures for installation of the hydrant(s).
Fire Department:
Full Plan Review
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant.
Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall
be 26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent
in grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions
of buildings hereafter constructed shall be accessible to fire department apparatus by way of
an approved fire apparatus access road with an asphalt, concrete or other approved driving
surface capable of supporting the imposed load of fire apparatus weighing at least 75,000
pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead Ends. Dead-end fire
apparatus access roads in excess of 150 feet shall be provided with width and turnaround
provisions in accordance with Table D103.4. Requirements for Dead-end fire apparatus access
roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.5 Fire apparatus access road gates. Gates securing
the fire apparatus access roads shall comply with all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by one person.
4. Gate components shall be maintained in an operable condition at all times and replaces
or repaired when defective.
ITEM NO.: 16
File No. Z-9407
5. Electric gates shall be equipped with a means of opening the gate by fire department
personnel for emergency access. Emergency opening devices shall be approved by the
fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock unless
they are capable of being opened by means of forcible entry tools or when a key box
containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code official
8. Electric gate operators, where provided, shall be listed in accordance with UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and installed to
comply with requirements of ASTM F 2200.
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code Vol. 1, One- or
Two -Family dwelling residential developments. Developments of one- or two-family
dwellings where the number of dwelling units exceeds 30 shall be provided with two separate
and approved fire apparatus access roads, and shall meet the requirements of Section D104.3.
Exceptions:
1. Where there are more than 30 dwelling units on a single public or private fire
apparatus access road and al dwelling units are equipped throughout with an
approved automatic sprinkler system in accordance with Section 903.3.1.1,
903.3.1.2 or 903.3.1.3 of the Arkansas Fire Code, access from two directions shall
not be required.
2. The number of dwelling units on a single fire apparatus access road shall not be
increased unless fire apparatus access roads will connect with future development,
as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire Prevention Code.
Section C101 — C105, in conjunction with Central Arkansas Water (Daniel Tull 501-377-1245)
and the Little Rock Fire Marshals Office (Capt. Tony Rhodes 501-918-3757). Number and
Distribution of Fire Hydrants as per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
Building CodeslLandsca e:
Building Code:
Code Fire Separation is required between units. Type of separation depends on exact distance
between buildings. No shared utilities between properties. Utilities must be in easement and
on property of the dwelling served.
ITEM NO.: 16
File No. Z-9407
Landscape: No Comment.
Transportation/Planning:
Rock Region Metro: No comments received.
Planning Division:
This request is located Otter Creek Planning District. The Land Use Plan shows Residential
Low Density (RL) and Residential Medium Density (RM) for this property. The Residential Low
Density is for single-family homes at densities no greater than six dwelling units per acre. Such
residential development is typically characterized by conventional single family homes, but may
also include patio or garden homes and cluster homes, provided that the density remain less
than 6 units per acre. The Residential Medium Density category accommodates a broad range
of housing types including single family attached, single family detached, duplex, town homes,
multi -family and patio or garden homes. Any combination of these and possibly other housing
types may fall in this category provided that the density is between six (6) and twelve (12)
dwelling units per acre. The applicant has applied for a rezoning from R-2 (Single-family
District) to PRD (Planned Residential District) to allow the construction of a subdivision of triplex
and quad-plex units on separate lots.
Master Street Plan: There are not streets adjacent to the site. Pine Rock Court and Big Rock
Avenue enter the site from the east in the north and south parts of the site respectively. Both
are shown on the Master Street Plan as Local Streets. The primary function of Local Streets
is to provide access to adjacent properties. Local Streets that are abutted by non-residential
zoning/use or more intensive zoning than duplexes are considered as "Commercial Streets".
A Collector design standard is used for Commercial Streets. These streets may require
dedication of right-of-way and may require street improvements for entrances and exits to the
site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Revised plat/plan: Submit responses to staff issues and four (4) copies of a revised
preliminary plat/plan (to include the additional information as noted above) to staff on or before
April 10, 2019. If you have any questions please contact Dana Carney, dcarney@littlerock.gov
or 501.371.6817 or Jamie Collins, gcolfins_ _ littlerock.gov or 501.371.6818.
FILE NO.: Z-9407
NAME: Village at the Gateway Long -form PRD
LOCATION: West of the existing Village at the Gateway, 4 blocks west of
Vimy Ridge Road
DEVELOPER:
Big Rock Development
12506 Vimy Ridge Road
Little Rock, AR 72002
OWNER/AUTHORIZED AGENT:
Big Rock Development/owner
McGetrick & McGetrick/authorized agent
SURVEYOR/ENGINEER:
McGetrick & McGetrick
11601 Bass Pro Parkway
Little Rock, AR 72210
AREA: 12.7 acres NUMBER OF LOTS: 48
WARD: 7 PLANNING DISTRICT: 16
CURRENT ZONING: R-2
ALLOWED USES
PROPOSED ZONING
PROPOSED USE
VARIANCEMAIVERS
BACKGROUND:
FT. NEW STREET: 2,475 LF
CENSUS TRACT: 41.04
Single Family, Townhouse Development
a-1
Multi -family; Tri-plex and Four-plex
Advance grading of the entire site with first phase_
This 12.70 acre site is part of a larger 35 acre site which was previously approved for
development as a 293 lot townhouse community with lots that averaged 30 feet in width
and 100 feet in depth. That use is permitted in the R-2 zoning district. The eastern portion
FILE NO.: Z-9407 (Cont.
of the development is nearing completion. Within this 12.7 acre portion of the
development, 106 townhouse style lots had been approved.
0
PROPOSAL/REQUEST/APPLICANT'S STATEMENT:
The applicant is now proposing a PRD zoning to allow for the combining of pairs
of the 30 foot wide townhouse style lots into 48, 60- foot wide lots to be developed
with a mixture of tri-plex and four-plex units. The proposed units are as follows:
3 bedroom
1 % level
22 units
1,465 sq.
ft. each
2 bedroom
1 level
2 units
1,025 sq.
ft. each
2 bedroom
1 Y2 level
22 units
1,360 sq.
ft. each
1 bedroom
1 level
49 units
710 sq.
ft. each
Studio
1 level
51 units
515 sq.
ft. each
Setbacks are proposed to be 15' in the front except along the east side of Pine
Rock and along both sides of Woodstone where a minimum of 5 feet is requested.
The lots in those areas are rear loaded off of the alley and have no driveways onto
the streets. The applicant states he desires to be able to offset some of the homes
so they don't all line up for aesthetic purposes. Rear yard setbacks are proposed
as 15'except along the northern perimeter where 30' rear yard is indicated. Interior
setbacks are proposed at 5'.
Parking is proposed at 206 open spaces at the units, 63 garage spaces within
some of the units and 33 general shared spaces located within parking lots in the
middle of the development.
Open space is proposed as 2.21 acres to be used for playgrounds, dog park and
lounging areas.
The street are proposed to be private.
EXISTING CONDITIONS:
The site is cleared and undeveloped. The first phase of the development to the
east is nearing completion. North of the site the uses include residential,
commercial and industrial. Undeveloped property extends to the west. The PCD
to the south was approved for a mixed use development by this same developer.
No development has yet occurred.
C. NEIGHBORHOOD COMMENTS:
Notice of the public hearing was sent to all owners of properties located within
200 feet of the site and the Alexander road, Quail Run and SWLRUP
Neighborhood Associations.
16
FILE NO.: Z-9407 (Cont.)
D. ENGINEERING COMMENTS:
PUBLIC WORKS CONDITIONS:
1. Driveway locations and widths do not meet the traffic access and circulation
requirements of Sections 30-43 and 31-210. Maximum residential driveway
width is 20 ft.
2. Backing out into public streets is not permitted due to safety concerns for any
development other than R-2.
3. Currently, waste is being collected privately. Does the owner plan to vary from
the private service with this revision?
4. A grading permit in accordance with section 29-186 (c) & (d) will be required
prior to any land clearing or grading activities at the site. Other than residential
subdivisions, site grading and drainage plans must be submitted and approved
prior to the start of construction. Is a variance being requested to advance
grade future phases? What is the proposed timing or trigger for the advance
grading activities?
5. Storm water detention ordinance applies to this property. Show the proposed
location for stormwater detention facilities on the plan. Maintenance of the
detention pond and all private drainage improvements is the responsibility of
the developer and/or land owner.
6. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from
the Arkansas Department of Environmental Quality prior to the start of
construction.
7. Hauling of fill material on or off site over municipal streets and roads requires
approval prior to a grading permit being issued. Contact Public Works Traffic
Engineering at 621 S. Broadway, (501) 379-1805 (Travis Herbner) for more
information.
8. Damage to public and private property due to hauling operations or operation
of construction related equipment from a nearby construction site shall be
repaired by the responsible party prior to issuance of a certificate of occupancy.
9. Staff understands no changes are proposed to the previously approved street
and drainage plans. Are any changes proposed?
E. UTILITIES/FIRE DEPARTMENT/PARKS/COUNTY PLANNING:
Little Rock Water Reclamation Authority: Sewer main extension required with
easements if new sewer service is required for this project. Capacity Fee Analysis
required.
Entergy:
Entergy does not object to this proposal. There do not appear to be any conflicts
with existing electrical utilities at this location. There is an existing underground
3
FILE NO.: Z-9407 (Cont.
power line in this area serving existing developments in the subdivision to the east.
Contact Entergy in advance to discuss electrical service requirements,
or adjustments to existing facilities (if any) as this project proceeds.
Centerpoint Energy: No comments received.
AT & T: No comments received.
Central Arkansas Water:
All Central Arkansas Water requirements in effect at the time of request for water
service must be met.
A water main extension will be needed to provide water service to this property.
Please submit plans for water facilities to Central Arkansas Water for review. Plan
revisions may be required after additional review. Contact Central Arkansas Water
regarding procedures for installation of water facilities. Approval of plans by Central
Arkansas Water, the Arkansas Department of Health Engineering Division and
Little Rock Fire Department is required.
This development will have minor impact on the existing water distribution system.
Proposed water facilities will be sized to provide adequate pressure and
fire protection.
If there are facilities that need to be adjusted and/or relocated, contact Central
Arkansas Water. That work would be done at the expense of the developer.
Additional fire hydrant(s) will be required
to obtain information regarding the
and contact Central Arkansas Water
the hydrant(s).
Fire Department:
Full Plan Review
Maintain Access:
Fire Hydrants.
. Contact the Little Rock Fire Department
required placement of the hydrant(s)
regarding procedures for installation of
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D
of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road
width with a hydrant. Where a fire hydrant is located on a fire apparatus access
road, the minimum road width shall be 26 feet, exclusive of shoulders.
4
FILE NO.: Z-9407 (Cont.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall
not exceed 10 percent in grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access and loading.
Facilities, buildings or portions of buildings hereafter constructed shall be
accessible to fire department apparatus by way of an approved fire apparatus
access road with an asphalt, concrete or other approved driving surface capable
of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
Dead Ends.
Maintain fire apparatus access roads at dead end locations as per Appendix
D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section D103.4 Dead
Ends. Dead-end fire apparatus access roads in excess of 150 feet shall be
provided with width and turnaround provisions in accordance with Table D103.4.
Requirements for Dead-end fire apparatus access roads.
Gates
Maintain fire apparatus access road gates as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.5 Fire apparatus access
road gates. Gates securing the fire apparatus access roads shall comply with
all of the following criteria:
1. Minimum gate width shall be 20 feet.
2. Gates shall be of swinging or sliding type.
3. Construction of gates shall be of material that allow manual operation by
one person.
4. Gate components shall be maintained in an operable condition at all times and
replaces or repaired when defective.
5. Electric gates shall be equipped with a means of opening the gate by fire
department personnel for emergency access. Emergency opening devices
shall be approved by the fire code official.
6. Manual opening gates shall not be locked with a padlock or chain and padlock
unless they are capable of being opened by means of forcible entry tools or
when a key box containing the keys to the lock is installed at the gate location.
7. Locking device specifications shall be submitted for approval \by the fire code
official
8. Electric gate operators, where provided, shall be listed in accordance with
UL 325.
9. Gates, intended for automatic operation shall be designed, constructed and
installed to comply with requirements of ASTM F 2200.
5
FILE NO.: Z-9407
One- or Two -Family Residential Developments.
As per Appendix D, Section D107.1 of the Arkansas Fire Prevention Code
Vol. 1, One- or Two -Family dwelling residential developments. Developments
of one- or two-family dwellings where the number of dwelling units exceeds 30
shall be provided with two separate and approved fire apparatus access roads,
and shall meet the requirements of Section D104.3.
Exceptions:
Where there are more than 30 dwelling units on a single public or
private fire apparatus access road and al dwelling units are equipped
throughout with an approved automatic sprinkler system in
accordance with Section 903.3.1.1, 903.3.1.2 or 903.3.1.3 of the
Arkansas Fire Code, access from two directions shall not be required.
2. The number of dwelling units on a single fire apparatus access road shall
not be increased unless fire apparatus access roads will connect with
future development, as determined by the fire code official.
Fire Hydrants
Locate Fire Hydrants as per Appendix C of the 2012 Arkansas Fire
Prevention Code. Section C101 — C105, in conjunction with Central Arkansas
Water (Daniel Tull 501-377-1245) and the Little Rock Fire Marshal's Office
(Capt. Tony Rhodes 501-918-3757). Number and Distribution of Fire Hydrants as
per Table C105.1.
Parks and Recreation: No comments received.
County Planning: No comments received.
F. BUILDING CODES/LANDSCAPE:
Building Code:
Code Fire Separation is required between units. Type of separation depends on
exact distance between buildings. No shared utilities between properties. Utilities
must be in easement and on property of the dwelling served.
Landscape: No Comment.
G. TRANSPORTATION/PLANNIN
Rock Region Metro: No comments received.
Planning Division:
This request is located Otter Creek Planning District. The Land Use Plan shows
Residential Low Density (RL) and Residential Medium Density (RM) for this
property. The Residential Low Density is for single-family homes at densities no
A
FILE NO.: Z-9407 (Cont.
greater than six dwelling units per acre. Such residential development is typically
characterized by conventional single family homes, but may also include patio or
garden homes and cluster homes, provided that the density remain less than
6 units per acre. The Residential Medium Density category accommodates a broad
range of housing types including single family attached, single family detached,
duplex, town homes, multi -family and patio or garden homes. Any combination of
these and possibly other housing types may fall in this category provided that the
density is between six (6) and twelve (12) dwelling units per acre. The applicant
has applied for a rezoning from R-2 (Single-family District) to PRD (Planned
Residential District) to allow the construction of a subdivision of triplex and
quad-plex units on separate lots.
Master Street Plan: There are not streets adjacent to the site. Pine Rock Court
and Big Rock Avenue enter the site from the east in the north and south parts of
the site respectively. Both are shown on the Master Street Plan as Local Streets.
The primary function of Local Streets is to provide access to adjacent properties.
Local Streets that are abutted by non-residential zoning/use or more intensive
zoning than duplexes are considered as "Commercial Streets". A Collector design
standard is used for Commercial Streets. These streets may require dedication of
right-of-way and may require street improvements for entrances and exits to
the site.
Bicycle Plan: There are no bike routes shown in the immediate vicinity.
Revised plat/plan: Submit responses to staff issues and four (4) copies of a
revised preliminary plat/plan (to include the additional information as noted
above) to staff on or before April 10, 2019. If you have any questions please
contact Dana Carney, dcarney@littlerock.gov or 501.371.6817 or Jamie Collins,
gcollins@littlerock.gov or 501.371.6818.
H. SUBDIVISION COMMITTEE COMMENT: (April 3, 2019)
The applicant was present. Staff presented the item and noted some additional
information was needed. Staff noted the applicant was requesting to advance
grade the site. Staff requested the applicant provide the linear feet of new street.
The applicant was asked to provide a phasing plan and to indicate it on the plan.
Staff noted the proposed open space comprised 8% of the site, less than the code
requirement of 10-15% as common usable open space. Staff requested some
description of the exterior of the proposed units. A fencing plan was requested.
Staff asked the applicant to describe the dumpster screening materials and stated
dumpster service hours should be limited to 7 am — 6 pm, Monday — Friday. The
applicant was asked to describe the proposed ownership plan for the development;
if individual lots could be sold. Staff commented that the proposed increase in
density was causing staff to consider the potential impact on existing infrastructure,
specifically Vimy Ridge Road.
rA
1�1��►[�af�'L��r/
Public Works comments were discussed. Specifically, staff stated vehicles backing
out into public streets was not permitted due to safety concerns for any
development other than R-2 single family.
Comments from the other departments and reviewing agencies were noted. The
applicant was advised to respond to staff issues by April 10, 2019. The committee
forwarded the item to the full commission.
ANALYSIS -
The applicant submitted responses and a revised site plan subsequent to
subdivision committee. The number of lots was reduced from 53 to 48. The number
of units was reduced from 166 to 146. Density is 11.5 units per acre. Open space
has been increased to 2.21 acres; 17.5% of the development. The streets are now
proposed as private, eliminating the concern about vehicles backing out into a
public street. The streets will be in an access and utility easement within a tract.
Big Rock Avenue will dead-end at the western perimeter of the site. A gate will be
installed so that a secondary emergency access can be provided when the
property adjacent to the west is developed. That property to the west will be
developed off of the new collector street which will extend from Vimy Ridge Road
to Alexander Road. All construction will take place in one phase.
The exterior of the new structures will match the structures now existing on the
development to the east; siding and rock finish. A six foot fence will be installed
along the north perimeter of the property. The management office will be located
in the clubhouse which is being constructed as a part of the first phase adjacent to
the east. All lots will be maintained under one ownership and the units are to be
leased. Dumpsters and mail kiosks are located in the center of the development.
Dumpster service hours should be limited to 7 am — 6 pm, Monday — Friday.
Although the applicant has requested a variance to allow advance grading of the
entire site with development of the first phase, the intent is to complete all
construction in one phase.
J. STAFF RECOMMENDATION:
Staff recommends approval of the requested PRD subject to compliance with the
comments and conditions outlined in paragraphs D, E and F and the staff analysis
in the agenda staff report.
PLANNING COMMISSION ACTION:
(APRIL 25, 2019)
The applicant was present. There were no objectors present. Staff presented the item
and a recommendation of approval as outlined in the "staff recommendation" above.
There was no further discussion. The item was placed on the consent agenda and
approved as recommended by staff, including all staff comments and conditions. The
vote was 10 ayes, 0 noes and 1 absent.