Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Z-9313 Map
r CD l �IF IY: T-MOBILE SITE NUMBER: T-MOBILE SITE NAME: PROJECT TYPE: AR01151 A FREEWAY MEDICAL NEW BUILD `71) STRUCTURE TYPE: ROOFTOP PC it PROJECT SUMMARY CONTACTS AREA MAP DRAWING INDEX SITE NAME: FREEWAY MEDICAL APPLICANT: F,ry ;rl�•' 1)'r '�;f'•,��' "ar SITE NUMBER: AR01151A T—MOBILE ! + T1 911 ADDRESS: 5800 W IOTH ST 12980 S FOSTER ST., SUITE 200 N1.0 LITTLE ROCK, AR 72204 OVERLAND PARK, KS 66213 1� �• PULASKI COUNTY PM CONTACT: DANA KELLY N1.1 ALPHA LATITUDE: 34 44' 39.Q7" PHONE: 402-301-9575 N1.2 ALPHA LONGITUDE: —92' 20' 20.49" EMAIL: DANA.KELLY47®T—MOBILE.COM ; �7 �>� BETA LATITUDE: 3,V 44' 38.45" CM CONTACT: MIKE HAANPAA f { I+" N2.0 BETA LONGITUDE —92' 20' 20.04" PHONE: 218-209-1001 N2.1 GAMMA LATITUDE. 34' 44' 38.46" EMAIL'MICHAEL.HAANPAA®T—MOSILE.COM BUILDING OWNER: SITE N3,0 GAMMA LONGITUDE —92' 20' 20.41" GROUND ELEVATION: ±345' AMSL RPM MANAGEMENT COMPANY INC. N4.0 JURISDICTION: CITY OF LITTLE ROCK VICKI BROWN PHONE: 501.666.6133 1 N4.1 SCOPE OF WORK ENGINEER: 1) THIS WIRELESS COMMUNICATIONS FACILITY IS NOT INTENDED FOR HUMAN OCCUPANCY 2) THIS FACILITY DOES NOT REQUIRE POTABLE WATER AND WILL NOT PRODUCE ANY SEWAGE. 3) THE SCOPE OF WORK CONSISTS OF PROPOSED KGI WIRELESS INC. BUILDING THREE, SUITE 370 805 LAS CIMAS PKWY. WIRELESS INSTALLATION: A. INSTALLATION OF (6) PROPOSED ANTENNAS AUSTIN, TX 78746 CONTACT: TYLER BOLINGER APPROVALS B. INSTALLATION OF (12) PROPOSED RRUS PRINCIPAL ENGINEER (REMOTE RADIO UNITS) PHONE: 512.334.3256 C. INSTALLATION OF (3) COVPS D. INSTALLATION OF (3) HYBRID CABLES POWER PROVIDER: PROPERTY OWNER OR REP. DATE ENTERGY 1-800—ENTERGY APPLICABLE CODES & STANDARDS RF ENGINEER DATE — INTERNATIONAL BUILDING CODE, 2012 EDITION AS ADOPTED BY LOCAL JURISDICTION LAND —USE PLANNER DATE — NATIONAL ELECTRICAL CODE, 2014 EDITION AS ADOPTED BY LOCAL JURISDICTION TELCO. AT&T ZONING AND REAL ESTATE DATE CONSTRUCTION MANAGER DATE r Know what's below. T—MOBILE DATE } Call before you dig. THE ABOVE PARTIES HEREBY APPROVE AND ACCEPT THESE DOCUMENTS AND AUTHORIZE CONTRACTOR TO PROCEED WITH THE CONSTRUCTION DESCRIBED HEREIN. ALL DOCUMENTS ARE SUBJECT TO REVIEW BY THE LOCAL BUILDING DEPARTMENT AND MAY IMPOSE CHANGES OR MODIFICATIONS. C1.0 C1.1 C1.2 C2.0 C2,1 RF1.0 RF2.0 RF3.0 RF4.0 RF4.1 E1.0 E1.1 E2.0 E3.0 E3.1 E4.0 E4.1 EQ 1. EQ 1. EQ1. EQ 1. EQ 1. EQ1, GENERAL SHEETS TITLE SHEET GENERAL NOTES GENERAL NOTES SYMBOLS & ABBREV. CIVIL NOTES CIVIL NOTES RF NOTES ELECTRICAL NOTES ELECTRICAL NOTES CIVIL SHEETS SITE PLAN PLATFORM DETAIL CIVIL DETAILS BUILDING ELEVATION ROOFTOP ANTENNA PLAN RF SHEETS ANTENNA/EQUIPMENT KEY PLUMBING DIAGRAM ANTENNA ONE —LINE DIAGRAM EQUIPMENT DETAILS EQUIPMENT DETAILS ELECTRICAL SHEETS OVERALL UTILITY PLAN PLATFORM UTILITY PLAN ONE —LINE DIAGRAM OVERALL GROUNDING PLAN PLATFORM GROUNDING PLAN GROUNDING DETAILS GROUNDING DETAILS EQUIPMENT DETAILS EQUIPMENT DETAILS EQUIPMENT DETAILS EQUIPMENT DETAILS EQUIPMENT DETAILS EQUIPMENT DETAILS REVISION 0 0 0 0 0 0 0 0 NOTE: DRAWING SCALES ARE FOR 11"X17" SHEETS UNLESS OTHERWISE NOTED. 0 0 0 0 0 0 0 _o 0 0 0 cETi1 MATH AHD gN. I IImry vmnFY TV AT TL9 SEALED DOP31p f Ms PREPARE9 of WE OIL UNWA W DEM CCNfRDL NW PV*OkN SUPFRYi•M AW I AM R liCUpiD PAOFiS . UriNUF tALM THE Mrs OF THE b7 M OF AMCW"..AS 1 1 a 11 06/2017 MER D. 90LIEWER, OCM ?WWSM 16825 RENE'NiL Dcse l5: li%S1f2410 rosS-vATE 6';1 WN ARIHSAS LICENSED PROFESSIONAL ENGINEER NO.16826 A WFZ fW.. AWAM FLU NO. 2&% RVOrAL DATE T - 4/lo Ile ■a T—MOBILE 12980 S FOSTER ST., SUITE 200 OVERLAND PARK, KS 66213 KGI WIRELESS, INC. ENGINEERING 605 LAS LIMAS PKWY BUILDING THREE, SUITE 370 AUSTIN, TX 78746 512.345.9595 SITE NAME: FREEWAY MEDICAL SITE NUMBER: AR01151 A SITE ADDRESS: 5800 W 10TH ST LITTLE ROCK, AR 72204 ROOF` 0P OWNER: FREEWAY MED9CAL TOWER HPR CONTROL CARD REVISION ISSUED FOR: DATE A REVIEW 09 05 2 B REVIEW 09 21 2 C REVIEW 09/27 2 0 REVIEW 10 17 2 p 1 CONSTRUCT1oN 11/05/2 SHEET TITLE: TITLE SHEET SHEET NUMBER: T1 IINI AN? SEA: UMMY INW 'FM SCK= Oi% WOR WAS 81 W OR UNDER W P11.ECT WFffROL Akl] skIPCRa610N AM I Al A IXEI PRC1E52�7GWL UMM MlZ tAn OF 'ME Wffll OF AnANS&S M7E "mm a1fOlmmx LMOGE wumm R: m211 MM& atm t5: 12/SltaIIs fTl 00l' 5- AT E 6 %� A lU A�] SAS LICENSED PROFESSIONAL ENGINEER NO.16826 r 4� EXISTING ROOFTOP n (2) PROPOSED 2" CONDUIT �{r BBoll,��{, PENETRATIONS TO EXISTING 9TH FLOOR STACKED ELECTRICAL ROOM KGI MMMS. INC., AWAWAS FM NO, 25H MEWAL PROPOSED STEPDOWN TRANSFORMER DATE 12/3 172015 PROPOSED ALPHA SECTOR EXISTING DISH T ®q�11111 j�� PROPOSED 878' ANTENNAS AND EQUIPMENT T-V,!MOBILE 'EQUIPMENT PLATFORM 12980 S FOSTER ST., SUITE 200 IF {3} PROPOSED T-MOBILE COUP EXISTING 9TH FLOOR OVERLAND PARK, KS 66213 HYBRID DL57R18UTION BOXES _ _ STACKED ELECTRICAL ROOM PROPOSE©1 T-MOBILE SSC PROPOSED PPC ENCLOSURE "I STING ELEVATOR MECHANICAL ROOM J EXISTING ROOFTOP PROPOA GPS ANTENNA PENTHOUSE - - EXISTING UPPER PENTHOUSE ROOF STAIRCASE EXISTING VENT KGI WIRELESS, INC. "1 (2) PROPOSED 6'x6" JUNCTION ENGINEERING BOXES INSTALLED ON INTERIOR OF PENTHOUSE WALL 805 LAS C1MA5 PKWY BUILDING THREE, SUITE 370 AUSTIN, TX 78746 EXISTING VENT 512,345.9595 (TYp•) o EXISTING DISH SITE NAME (2) PROPOSED 2" CONDUIT o PENETRATIONS ON EXISTING FREEWAY MEDICAL PENTHOUSE WALL WITH (2) PROPOSED 6"x6" JUNCTION BOXES SITE NUMBER: AR01151 A o PROPOSED PVC SLEEPERS TO SUPPORT CONDUIT SITE ADDRESS: EVERY 3'-0" O.C. MAX 5800 W 10TH ST (TYP') EXISTING DISH LITTLE ROCK, AR 72204 ROOFTOP OWNER: (3) PROPOSED 1.584" HIGH FREEWAY MEDICAL TOWER HPR CAPACITY HCS HYBRID CABLES PROPOSED BETA SECTOR CONTROL CARD PROPOSED GAMMA SECTOR ANTENNAS AND EQUIPMENT ANTENNAS AND EQUIPMENT PROPOSED CABLE TRAY REVISION ISSUED FOR: DATE (np) A REVIEW 09 O5 2017 B 1 REVIEW 09/21 /2017 EXISTING BUILDING PROPOSED SITE PLAN I - SCALE: 1/16"= t-O" 0 2' 4' 8' 16' 32' 48' NOTE: THIS SITE PLAN WAS DRAWN WITHOUT THE BENEFIT OF A CIVIL SURVEY OR SITE WALK; THEREFORE, THE CONTRACTOR SHALL VERIFY ALL EXISTING CONDITIONS, QUANTITIES AND DIMENSIONS BEFORE STARTING ANY WORK. NOTIFY THE CONSTRUCTION MANAGER OF ANY DISCREPANCIES OR INCONSISTENCIES BEFORE PROCEEDING WITH CONSTRUCTION. D SITE PLAN (3) PROPOSED 1.584" HIGH CAPACITY HCS HYBRID CABLES EXISTING ROOFTOP -` PROPOSED PVC SLEEPERS TO SUPPORT CONDUIT EVERY S-6" D.C. MAX (TYP•) (1) PROPOS�U 1-5/8" UNISTRUT FRAMING AND DIAGONAL BRACING AS REQUIRED TO MOUNT PROPOSED EQUIPMENT (TYP.) (3) PROPOSED COVP HYBRID DISTRIBUTION BOXES PROPOSED SYSTEM MODULES ON RRU MOUNTING PLATE ABOVE PROPOSED SSC PROPOSED SSG PROPOSED OVERHEAD MAXLITE LED WORK LIGHT MODEL #MLFL45LED50(W) (TYP. OF 2) PROPOSED 8'X8' T-MOBILE PLATFORM (COMMSCOPE PART # EO-POB08-8 OR SIMILAR) I j PROPOSED CABLE TRAY PROPOSED DISBURSEMENT LEGS FOR PLATFORM (COMMSCOPE PART I EQ-P-DF) (2) PROPOSED 12"X12`X4" NEMA TYPE 3 JUNCTION BOXES ♦� �i�����.�r�l PROPOSEDPROPOSEDENCLOSURE COVER `fir■ PROPOSED PROPOSED 24' ICE BRIDGE (LENGTH: 8'-8') I I PROPOSED 24`I ICE BRIDGE PRTSE'LCSIO" i ENCLOSURE \�rRC9OSM'GPS ANTENNA I I PROPOSED PLATFORM DETAILS SCALE: 1 /2"= 1'-0" 0 3" 6" 1' 2' 4' 6' EXISTING UPPER PENTHOUSE ROOF STAIRCASE ME ME RENEWAL UAW M' 12/31/2010 up A.RI ?.SAS LICENSED PROFESSIONAL ENGINEER NO.16826 A Of NFZEUW, M, AM01405 FM NO. =1 Ruff# L w3r 17/31/2015 T � ®Dddoile T-MOBILE 12980 S FOSTER ST., SURE 200 OVERLAND PARK, KS 66213 KGI WIRELESS, INC. ENGINEERING 805 LAS CIMAS PKWY BUILDING THREE, SURE 370 AUSTIN, TX 78746 512.345.9595 SITE NAME: FREEWAY MEDICAL SITE NUMBER: AR01151 A SITE ADDRESS: 5800 W 10TH ST LITTLE ROCK, AR 72204 ROOFTOP OWNER: FREEWAY MEDICAL TOWER HPR CONTROL CARD REVISION ISSUED FOR: DATE A REVIEW 09 05/2D17 B REVIEW 109 21 2017 C REVIEW 109 27 2017 D REVIEW 10/17 2017 O CONSTRUCTION 11/06/2017 PLATFORM DETAIL NUMBER: C1.1 EXISTING BUILDING CEtiI1RC MM MO Svu. I HERW CEAUFY'PJW'M$ SEALED PMUVDn RAS PROWM 9I W OR UIIOFR W OGIEOT MRM AMD PEHsauE SUPMVIS H ANO I Au A LK$ SU PAOii� EHCi M UNOFRi THE LAWS OF TNY 510.1Z OF ARK095AS (3) PROPOSED T-MOBILE COVP HYBRID DISTRIBUTION BOXES 11 OS 2017 otir� EXISTING PENTHOUSE PROPOSED SSC ON PROPOSED PLATFORM 125'-0" AGL Tnm a 0ouH0Ea tka+sE NUMOm tsaza PROPOSED T-MOBILE ANTENNAS RENEWAL DATE IS: 12/-3I/2015 ---�,i■■ - � � •+ f +: � iii i il���� '������1�■■■■■■lam � � �� �i Ilesson MINIM I I I MEMM07mmmIMEN 120'ROO AROOFTOP GL TOP OF ���T Er O F rr��it SAS ,t * * OMM5COPE FHH-65C-R3 LTE-AWS PANEL ANTENNA PANEL ANTENNA LICENSED COMMSCOPE -65C-R3 UMTS-PCSALTE-PCSA700 � PROFESSIONAL STANDOFF ARMS OVP HYBRID DISTRIBUTION BOX ® ENGINEER k * * OKIA FRBG RRU OKIA FRIJ RRU �.�N � OKIA FHFB RRU OKIA FHOA RRUR NO.16826 KGI W9>f.LE56, M, AWR S MM NO. 2335 REMW& DATE 12/31/201E T m -M—o11 mile T-MOBILE 12980 S FOSTER ST., SUITE 200 OVERLAND PARK, KS 66213 I PROPOSED BUILDING ELEVATION N.T:S INC. KGI WIRELESS, ENGINESCALE: 805 LAS CIMAS PKWY BUILDING THREE, SUITE 370 AUSTIN, TX 78746 512,345.9595 (3) PROPOSED T-MOBILE COVP HYBRID DISTRIBUTION BOXES PROPOSED SSG ON PROPOSED PLATFORM GAMMA 5E'TOR EQUIPMENT (1) PROPOSED T-MOBILE COMMSCOPE FHH-65C-R3 LTE-AWS PANEL ANTENNA (1) PROPOSED T-MOBILE COMMSCOPE FHH-65C-R3 UMTS-PCSATE-PCSA700 PANEL ANTENNA (2) PROPOSED T-MOBILE STANDOFF ARMS (1) PROPOSED T-MOBILE COUP HYBRID DISTRIBUTION BOX (1) PROPOSED T-MOBILE NOKIA FROG RRU (1) PROPOSED T-MOBILE NOKIA FRIJ RRU (1) PROPOSED T-MOBILE NOKIA FHFB RRU (1) PROPOSED T-MOBILE NOMA FHOA RRU EXISTING BUILDING 1 BETA SECTOR EQUIPMENT (1) PROPOSED T-MOBILE COMMSCOPE FHH-65C-R3 LTE-AWS PANEL ANTENNA (1) PROPOSED T-MOBILE COMMSCOPE FHH-65C-R3 UMTS-PCS/LTE-PCSA700 PANEL ANTENNA (2) PROPOSED T-MOBILE STANDOFF ARMS (1) PROPOSED T-MOBILE GOVP HYBRID DISTRIBUTION BOX (1) PROPOSED T-MOBILE NOKIA FROG RRU (1) PROPOSED T. MOBILE NOKIA FRIJ RRU (1) PROPOSED T-MOBILE NOKIA FHFB RRU (1) PROPOSED T-MOBILE NOKIA FHOA RRU PROPOSED r MOBELE N AGL Af�TFNNAS 12&-0° AGL,• 1. l TOP OF ROOFTOP SITE NAME: FREEWAY MEDICAL SITE NUMBER: AR01151 A SITE ADDRESS: 5800 W 10TH ST LITTLE ROCK, AR 72204 ROOFTOP OWNER: FREEWAY MEDICAL TOWER HPR CONTROL CARD REVISION ISSUED FOR: DATE A REVIEW W/O 2017 B REVIEW 09 21 2017 C REVIEW 109 27 2017 D REVIEW 10 17 2017 O CONSTRUCTION 11 O6 2017 SHEET TITLE: BUILDING ELEVATION PROPOSED BUILDING ELEVATION SCALE: N.T.S. SHEET NUMBER: C2