HomeMy WebLinkAboutZ-9265 Staff AnalysisOctober 26, 2017
ITEM NO.: 7 (Cont.
FILE NO.: Z-9265
in depth with a minimum driveway width of 20 feet. The plan indicates
parking stalls 18 feet in depth with a 20 foot driveway. This results in
a shortage of 4 feet in required depth across the northern and southern
parking lots.
4. SCREENING AND BUFFERS:
Site plan must comply with the City's minimal landscape and buffer
ordinance requirements.
A perimeter planting strip is required along any side of a vehicular use
area that abuts adjoining property or the right-of-way of any street. This
strip shall be at least nine (9) feet wide. One (1) tree and three (3) shrubs
or vines shall be planted for every thirty (30) linear feet of perimeter
planting strip. Perimeter planting strips are partially deficient on the south
and west sides of the property. Perimeter planting strips are deficient.
Screening requirements will need to be met for the vehicular use areas
adjacent to street right-of-ways. Provide screening shrubs with an average
linear spacing of not less at three (3) feet within the required landscape
area. Provide trees with an average linear spacing of not less than thirty
(30) feet.
Eight percent (8%) of the vehicular use area must be designated for green
space; this green space needs to be evenly distributed throughout the
parking area(s). The minimum size of an interior landscape area shall be
one hundred fifty (150) square feet for developments with one hundred
fifty (150) or fewer parking spaces. Interior islands must be a minimum
of seven and one half (7 1/2) feet in width. Trees shall be included in
the interior landscape areas at the rate of one (1) tree for every twelve
(12) parking spaces.
Landscape areas shall be provided between the vehicular use area used
for public parking and the general vicinity of the building, excluding truck
loading or service areas not open to public parking. These shall be
provided at the rate equivalent to planter strip three (3) feet wide along the
vehicular use area. One (1) tree and four (4) shrubs shall be planted in the
building landscape areas for each forty (40) linear feet of vehicular use
area abutting the building. Landscape areas will need to be added for the
commercial building.
An automatic irrigation system to water landscaped areas shall be
required for developments of one (1) acre or larger.
2
October 26, 2017
ITEM NO.: 7 (Cont.) FILE NO.: Z-9265
The development of two (2) acres or more requires the landscape plan to
be stamped with the seal of a Registered Landscape Architect.
The City Beautiful Commission recommends preserving as many existing
trees as feasible on this site. Credit toward fulfilling Landscape Ordinance
requirements can be given when preserving trees of six (6) inch caliper
or larger.
5. PUBLIC WORKS-
1 . Repair or replace any curb and gutter or sidewalk that is damaged in
the public right-of-way prior to occupancy.
2. A grading permit in accordance with section 29-186 (c) & (d) will be
required prior to any land clearing or grading activities at the site.
Other than residential subdivisions, site grading and drainage plans
must be submitted and approved prior to the start of construction.
Are the apartments proposed to construct in phases. If so, is an
advanced grading permit being requested to advance grade future
phases with Phase 1?
3. Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
4. Storm water detention ordinance applies to this property. Show the
proposed location for stormwater detention facilities on the plan.
Maintenance of the detention pond and all private drainage
improvements is the responsibility of the developer and/or property
owner.
5. If disturbed area is 1 or more acres, obtain a NPDES storm water
permit from the Arkansas Department of Environmental Quality prior
to the start of construction.
6. Hauling of fill material on or off site over municipal streets and roads
requires approval prior to a grading permit being issued. Contact
Public Works Traffic Engineering at 621 S. Broadway, (501) 379-1805
(Travis Herbner) for more information.
7. Driveway locations and widths do not meet the traffic access and
circulation requirements of Sections 30-43 and 31-210. Driveway
spacing on a commercial street is 250 ft. from driveways and
intersections and 125 ft. from side property lines. Variances must be
requested for the proposed driveway locations.
8. Provide a letter prepared by a registered engineer certifying the
intersection sight distance at the intersection(s) comply with 2004
AASHTO Green Book standards.
3
October 26, 2017
ITEM NO.: 7 (Cont.) FILE NO.: Z-9265
9. Damage to public and private property due to hauling operations or
operation of construction related equipment from a nearby construction
site shall be repaired by the responsible party prior to issuance of a
certificate of occupancy.
6. UTILITY, FIRE DEPT. AND CATA COMMENTS:
Little Rock Water Reclamation Authority: Sewer Available to this site.
Existing easements must be retained. Capacity Fee Required for multi-
family. No pool drain to sewer.
Entergy: Entergy does not object to this proposal. A single phase power
line exists along the west side of Wilson Road on the eastern edge of
this property. Both proposed driveways appear to be fairly close to
existing power poles. Care should be used so that all OSHA and NESC
clearances are met and maintained during and after the construction of
this project. Contact Entergy in advance to discuss electrical service
requirements, or adjustments to existing facilities (if any) as this project
proceeds.
Centerpoint Energy: No comments received.
AT&T: No comment.
Water: NO OBJECTIONS; All Central Arkansas Water requirements in
effect at the time of request for water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per
Appendix D of the 2012 Arkansas Fire Prevention Code Vol. 1 Section
D103.1 Access road width with a hydrant. Where a fire hydrant is
located on a fire apparatus access road, the minimum road width shall be
26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.2 Grade. Fire
apparatus access roads shall not exceed 10 percent in grade except as
approved by the fire chief.
Loading
CI
October 26, 2017
ITEM NO.: 7 (Cont.
9I4:801[61WALO -V
Maintain fire apparatus access road design as per Appendix D of the
2012 Arkansas Fire Prevention Code Vol. 1 Section D102.1 Access
and loading. Facilities, buildings or portions of buildings hereafter
constructed shall be accessible to fire department apparatus by way of
an approved fire apparatus access road with an asphalt, concrete or
other approved driving surface capable of supporting the imposed load
of fire apparatus weighing at least 75,000 pounds.
Building Codes:
Project is subject to full commercial plan review and approval prior to
issuance of a building permit. For information on submittal requirements
and the review process, contact a commercial plans examiner:
Curtis Richey at 501.371.4724; criche Iittlerock. q ov or
Mark Alderfer at 501.371.4875; malderfer@Iittlerock.gov .
County Planning: No comment.
7. TRANSPORTATION AND PLANNING:
Rock Region METRO: Location would be served by Route 3 Baptist
Medical Center along Kanis Road. We have no objections to proposed
improvements.
Planning Division: No comment.
BDIVISION COMMITTEE COMMENT: (OCTOBER 4, 2017)
The applicant was present. Staff presented the item and noted that a great deal
of additional information was needed regarding specifics of the development.
Staff outlined the areas where additional information was needed.
Public Works Comments were discussed. In response to a question, the
applicant stated the development would be constructed in one phase. The
applicant stated the driveways would not be gated and a variance would be
requested to allow the proposed driveway locations. Staff also requested a
sketch grading and drainage plan.
Landscape Comments were discussed. It was noted that the plan did not allow
for required minimum landscape and buffer areas. The applicant stated he had
already been working on a revision to the plan to address those issues.
5
October 26, 2017
ITEM NO.: 7 (Cont.) FILE NO.: Z-9265
Other Agency Comments were noted.
The applicant was and used to respond to staff's issues by October 11, 2017,
The Committee then forwarded the item to the full Commission.
STAFF ANALYSIS:
The applicant is requesting approval of a conditional use permit to allow for
development of a three building, 72 unit multifamily project on this undeveloped,
2.5 acre, 0-3 zoned tract. 0-3 does allow as a conditional use, multifamily as
per the R-5 district. R-5 establishes the allowable density, based on lot size.
For lots in excess of 1 acre, 1,200 square feet of land area per dwelling (unit)
is required. A 2.5 acre lot could allow up to 90 dwellings (units).
The development is proposed to consist of 3, 3-story apartment buildings; each
containing 24 units. A centralized common area will contain the office building,
a pool and a dog park. The site will be enclosed on three sides with a 6-foot tall
black vinyl fence. The site will not be gated.
The buildings will be 35 feet in height. Construction materials are brick and
Hardie panels with a 1/2 /12 pitched roof. There will be 54, 2-bedroom units
(1,100 sq. ft. each) and 18, 3-bedroom units (1,350 sq. ft. each).
Signage will consist of a single, monument -style sign meeting multifamily district
standards. The dumpster is indicated to be placed at the northwest corner of the
site. It will be screened to meet Code Standards.
Access to the site is via 2 driveways off of Wilson road. The driveways are
located nearer the north and south property lines than typically permitted. Staff
is supportive of a variance to allow the driveway locations. A 72-unit multifamily
development requires 108 parking spaces. 108 spaces are proposed. The
parking design as proposed does not meet code standards. The code requires
a parking stall depth of 20 feet and a minimum driveway width of 20 feet. The
applicant is proposing 18 foot deep parking stalls off each side of a 20 foot
driveway. This results in a 4 foot shortage in required overall depth for the
parking spaces located in the north and south parking lots.
The applicant has indicated perimeter and interior landscape areas to comply
with Landscape Code Standards.
With the exception of the parking lot design, the revised site plan addresses most
of the issues raised at Subdivision Committee.
101
October 26, 2017
ITEM NO.: 7 (Cont.) _ FILE NO.. Z-9265
Staff does have reservations about the appropriateness of the development
at this location. As noted earlier, the property is located in an area that is
developing as a small office park; primarily medical offices and clinics.
Multifamily is not a permitted by -right use in 0-3. It is a conditional use. The
Commission is to determine the appropriateness of each proposed conditional
use. That includes determining if the proposed use is compatible with other
properties in the area where the use is proposed to be located. It is staff's
opinion that this site is not appropriate for the proposed use.
The bill of assurance provide by the applicant does not address use issues.
It states "...all buildings shall be constructed in conformance with the Building
Code and Zoning Ordinance of the City of Little Rock."
STAFF RECOMMENDATION:
Staff recommends denial of the application.
PLANNING COMMISSION ACTION: (OCTOBER 26, 2017)
The applicants were present. There were two objectors present. E-mails and
letter of opposition had been received from eight area property owners and
businesses. Staff presented the item and a recommendation of denial.
Mike Marlar, of Marlar Engineering, addressed the commission. He presented
renderings of the elevations of the proposed buildings. He stated this same
applicant was building a multifamily project one block to the west, on Aldersgate
Road. Mr. Marlar stated there was a need for new multifamily in the area to
serve persons working in the area.
Gwen Gilbert addressed the commission. She stated they were building a
50-unit development on the west side of Aldersgate Road. She stated a smaller
multifamily development appealed to some people who did not want to live in a
large development, such as those being built along Bowman Road. Ms. Gilbert
stated they were providing housing closer to the hospital and offices to serve those
persons working at those businesses. She stated there had been no new office
development in the area for several years. She stated this proposed development
was in close proximity to services.
Dr. Robert Rice, of 1301 Wilson Road, spoke in opposition. He stated he had
spoken with all other professional offices in the area and there was no support for
the proposed multifamily development. He stated he had gone door-to-door along,
Wilson, Nichols and Perry Streets, south to 18t" Street to visit with residents and
they also want the property to remain office, not multifamily. He noted the office
uses were not open in the evenings and most weekends whereas multifamily
7
October 26, 2017
ITEM NO.: 7 (Cont.) FILE NO.: Z-9265
would have activity 24/7. Dr. Rice stated multifamily would add to the already
congested traffic on Kanis Road.
Ruth Bell, of the League of Women Voters of Pulaski County, spoke in
opposition. She stated this neighborhood was experiencing a resurgence
with new residential and quality office development. She stated this was a
very attractive location for new office development. Ms. Bell stated persons
who buy property is an area expect surrounding properties to be developed as
they are zoned and planned, including office owners. She stated this proposed
multifamily was an inappropriate use for this site.
Mike Marlar responded that an office development would generate more traffic
concentrated in peak hours where a multifamily development would spread that
traffic throughout the day.
In response to a question from Commissioner Dillon, Mr. A. J. Gilbert stated the
units would range in size from about 900 square feet to 1,200 square feet.
In response to a question from Commissioner Hamilton, Mr. Gilbert showed a
photograph of his project on the west side Aldersgate Road, which is currently
under construction. Mr. Gilbert described the energy efficiency of his
development. There was a discussion then of his proposed energy -efficiency
plan.
Commissioner Laha expressed his support for the project. He stated there was
a need for housing in close proximity to the office uses and there had been no
new office development in the area.
In response to a question from Vice -chair Bubbus, Mr. Gilbert stated his project
cost was $14,000,000, including a proposed expansion of his development on
Aldersgate Road. Vice -chair Bubbus stated there did not appear to be a lot of
neighborhood opposition present in the room. He voiced his support for the
project.
Commissioner Latture stated it appeared to be a quality development but it was
on the wrong site, in the middle of an office park.
In response to a question from Chairman Berry, Vince Floriani of Public Works
stated improvements to Kanis Road were planned for west of Shackleford road.
In response to a questions from Commissioner Dillon, Mr. Gilbert stated rental
rates were in the $800 - $1,000 range.
Zoning and Subdivision Manager Dana Carney said staff acknowledged the
quality of Mr. Gilbert's proposed development but that wasn't the only issue.
He stated the question before the commission was primarily a use -issue. He
October 26, 2017
ITEM NO.: 7 (Cont.) FILE NO.: Z-9265
reiterated Ms. Bell's statement that business owners had bought their properties
assuming they would be located in an office park. He said the statements that
there had not been new office development in a while did not mean there would
not ever be new office development. He stated this area had been planned for
office development.
Commissioner May stated the commission should stick with the plan and he
could not support the multifamily development.
Vice -chair Bubbus stated he understood the need to depend on the plan but
there needs to be room to have the flexibility to make exceptions.
A motion was made to approve the item with all staff comments and conditions
except the recommendation of denial. The motion failed with a vote of 5 ayes,
6 noes and 0 absent. The item was denied.
SUBDIVISION COMMITTEE COMMENTS
OCTOBER 4, 2017
ITEM NO.: 7. LOT 9 BAPTIST HEALTH — KANIS SOUTH ADDITION MULTI -FAMILY
CONDITIONAL USE PERMIT
WEST SIDE OF 1300 BLOCK OF WILSON ROAD Z-9255
Planning Staff Comments:
1. Provide a copy of the existing bill of assurance for Lot 9, Baptist Health — Kanis South Addition
2. Provide agent authorization
3. Provide building height and explain how that measurement was obtained.
4. Provide information on building design; exterior materials, roof materials and pitch
5. Provide signage age plan; building and ground
6. Provide height and materials of proposed fencing
7. Provide dimensions of parking stalls
8. Provide dimensions of perimeter landscape strips.
9. Locate and describe site lighting; should be low-level and directional, shielded downward and into
the site
10. Provide breakdown and numbers of types of units; 1, 2 or 3 bedroom
11. Provide size of units.
12. Will there be other outside uses such as a dog park area or an area for picnics, cookouts, playground
area? If so, indicate.
13. Confirm that the entrances will not be gated.
Variance/Waivers:
None requested.
Public Works:
1. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior
to occupancy.
2. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. Are the apartments
proposed to constructed in phases. If so, is an advanced grading permit being requested to advance
grade future phases with Phase I?
3. Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
4. Storm water detention ordinance applies to this property. Show the proposed location for
stormwater detention facilities on the plan. Maintenance of the detention pond and all private
drainage improvements is the responsibility of the developer and/or property owner.
5. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
6. Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
7. Driveway locations and widths do not meet the traffic access and circulation requirements of
Sections 30-43 and 31-210. Driveway spacing on a commercial street is 250 ft from driveways and
intersections and 125 ft from side property lines. Variances must be requested for the proposed
driveway locations.
ITEM NO.. 7. (CON'T) (Z-9265)
8. Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
9. Damage to public and private property due to hauling operations or operation of construction related
equipment from a nearby construction site shall be repaired by the responsible party prior to issuance
of a certificate of occupancy.
Utilities and Fire De artment/Qoun Planning:
Little Rock Water Reclamation Authority: Sewer Available to this site. Existing easements must be
retained. Capacity Fee Required for multi -family. No pool drain to sewer.
Entergy: Entergy does not object to this proposal. A single phase power line exists along the west side of
Wilson Road on the eastern edge of this property. Both proposed driveways appear to be fairly
close to existing power poles. Care should be used so that all OSHA and NESC clearances are met
and maintained during and after the construction of this project. Contact Entergy in advance to
discuss electrical service requirements, or adjustments to existing facilities (if any) as this project
proceeds.
Centerpoint Energy: No comments received.
AT&T: No comment.
Water: NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant. Where
a fire hydrant is located on a fire apparatus access road, the minimum road width shall be 26 feet,
exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention Code
Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in grade
except as approved by the fire chief.
Loadin
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of buildings
hereafter constructed shall be accessible to fire department apparatus by way of an approved fire
apparatus access road with an asphalt, concrete or other approved driving surface capable of
supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
ITEM NO.: 7. (CON'T1_ (2-9265)
Building Codes:
Project is subject to full commercial plan review and approval prior to issuance of a building
permit. For information on submittal requirements and the review process, contact a commercial
plans examiner:
Curtis Richey at 501.371.4724; crichey@1ittleroek.gov or
Mark Alderfer at 501.371.4875; malderfer rr,littlerock.gav .
County Planning: No comment.
Rock Region METRO: Location would be served by Route 3 Baptist Medical Center along Kanis Road.
We have no objections to proposed improvements.
Planning Division: No comment.
Landscape:
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining
property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1) tree
and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter planting
strip. Perimeter planting strips are partially deficient on the south and west sides of the property.
Perimeter planting strips are deficient.
Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-
ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within the
required landscape area. Provide trees with an average linear spacing of not less than thirty (30) feet.
Eight percent (8%) of the vehicular use area must be designated for green space; this green space
needs to be evenly distributed throughout the parking area(s). The minimum size of an interior
landscape area shall be one hundred fifty (150) square feet for developments with one hundred fifty
(150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7 1/2) feet
in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree for every
twelve (12) parking spaces.
Landscape areas shall be provided between the vehicular use area used for public parking and the
general vicinity of the building, excluding truck loading or service areas not open to public parking.
These shall be provided at the rate equivalent to planter strip three (3) feet wide along the vehicular
use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas for each
forty (40) linear feet of vehicular use area abutting the building. Landscape areas will need to be
added for the commercial building.
An automatic irrigation system to water landscaped areas shall be required for developments of one
(1) acre or larger.
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect.
ITEM NO.: 7. CON'T Z-9265
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving trees
of six (6) inch caliper or larger.
Other: Submit responses to staff issues and four (4) copies of a revised site plan (if required) no later than
Wednesday, October 11, 2017. Required notices are to be sent via certified mail to all owners of properties
located within two hundred (200) feet of the site no later than Wednesday October 11, 2017. The City
provided notices form must be used. Proof of notices is to be provided to staff no later than October 20,
2017.
SUBDIVISION COMMITTEE COMMENTS
OCTOBER 4, 2017
ITEM NO.: 7. LOT 9 BAPTIST HEALTH — KANIS SOUTH ADDITION MULTI -FAMILY
CONDITIONAL USE PERMIT
WEST SIDE OF 1300 BLOCK OF WILSON ROAD Z-9265
Planning Staff Comments:
1. Provide a copy of the existing bill of assurance for Lot 9, Baptist Health — Kanis South Addition
SEE ATTACHED
2. Provide agent authorization
SEE ATTACHED
3. Provide building height and explain how that measurement was obtained.
35' PER ARCHITECT DRAWINGS
4. Provide information on building design; exterior materials, roof materials and pitch
LISTED ON DRAWING
5. Provide signage age plan; building and ground
SEE DRAWING
6. Provide height and materials of proposed fencing
6' BLACK VINYL FENCE (STATED ON DRAWING)
7. Provide dimensions of parking stalls
SHOWN ON PLAN
8. Provide dimensions of perimeter landscape strips.
SHOWN ON DRAWING
9. Locate and describe site lighting; should be low-level and directional, shielded downward and into
the site
WALL PACK ON THE BUILDING W/ CUT-OFF LENS NOT TO EXTENT PAST THE
PARKING LOT
10. Provide breakdown and numbers of types of units; 1, 2 or 3 bedroom
54-TWO BEDROOM & 18 THREE BEDROOM (NOTED ON PLAN)
11. Provide size of units.
2 BEDROOM= 1,100 & 3 BEDROOM= 1,350
12. Will there be other outside uses such as a dog park area or an area for picnics, cookouts,
playground area? If so, indicate.
SHOWN ON DRAWING
13. Confirm that the entrances will not be gated.
ENTRANCES WILL NOT BE GATED
Variance/Waivers:
None requested.
Public Works:
1. Repair or replace any curb and gutter or sidewalk that is damaged in the public right-of-way prior
to occupancy. NOTED
2. A grading permit in accordance with section 29-186 (c) & (d) will be required prior to any land
clearing or grading activities at the site. Other than residential subdivisions, site grading and
drainage plans must be submitted and approved prior to the start of construction. Are the
apartments proposed to constructed in phases. If so, is an advanced grading permit being
requested to advance grade future phases with Phase 1?
ONLY GOING TO BE ONE PHASE
3. Provide a Sketch Grading and Drainage Plan per Sec. 29-186 (e).
WORKING ON THE SKETCH
4. Storm water detention ordinance applies to this property. Show the proposed location for
stormwater detention facilities on the plan. Maintenance of the detention pond and all private
drainage improvements is the responsibility of the developer and/or property owner.
SEE NOTE ON DRAWING
5. If disturbed area is 1 or more acres, obtain a NPDES storm water permit from the Arkansas
Department of Environmental Quality prior to the start of construction.
WILL DO
6. Hauling of fill material on or off site over municipal streets and roads requires approval prior to a
grading permit being issued. Contact Public Works Traffic Engineering at 621 S. Broadway, (501)
379-1805 (Travis Herbner) for more information.
WILL DO
7. Driveway locations and widths do not meet the traffic access and circulation requirements of
Sections 30-43 and 31-210. Driveway spacing on a commercial street is 250 ft from driveways
and intersections and 125 ft from side property lines. Variances must be requested for the
proposed driveway locations.
WE WOULD LIKE TO REQUEST THE VARIANCES FOR THE PROPOSED DRIVEWAYS
ITEM NO.: 7. (CON'T) (Z-9265)
8. Provide a letter prepared by a registered engineer certifying the intersection sight distance at the
intersection(s) comply with 2004 AASHTO Green Book standards.
WILL PROVIDE
9. Damage to public and private property due to hauling operations or operation of construction
related equipment from a nearby construction site shall be repaired by the responsible party prior
to issuance of a certificate of occupancy. NOTED
Utilities and Fire Department/County Planning
Little Rock Water Reclamation Authority: Sewer Available to this site. Existing easements must be
retained. Capacity Fee Required for multi -family. No pool drain to sewer.
Entergy: Entergy does not object to this proposal. A single phase power line exists along the west side of
Wilson Road on the eastern edge of this property. Both proposed driveways appear to be fairly
close to existing power poles. Care should be used so that all OSHA and NESC clearances are
met and maintained during and after the construction of this project. Contact Entergy in advance
to discuss electrical service requirements, or adjustments to existing facilities (if any) as this
project proceeds.
Centerpoint Energy: No comments received.
AT&T: No comment.
Water: NO OBJECTIONS; All Central Arkansas Water requirements in effect at the time of request for
water service must be met.
Fire Department:
Maintain Access:
Fire Hydrants.
Maintain fire apparatus access roads at fire hydrant locations as per Appendix D of the 2012
Arkansas Fire Prevention Code Vol. 1 Section D103.1 Access road width with a hydrant.
Where a fire hydrant is located on a fire apparatus access road, the minimum road width shall be
26 feet, exclusive of shoulders.
Grade
Maintain fire apparatus access roads as per Appendix D of the 2012 Arkansas Fire Prevention
Code Vol. 1 Section D103.2 Grade. Fire apparatus access roads shall not exceed 10 percent in
grade except as approved by the fire chief.
Loading
Maintain fire apparatus access road design as per Appendix D of the 2012 Arkansas Fire
Prevention Code Vol. 1 Section D102.1 Access and loading. Facilities, buildings or portions of
buildings hereafter constructed shall be accessible to fire department apparatus by way of an
approved fire apparatus access road with an asphalt, concrete or other approved driving surface
capable of supporting the imposed load of fire apparatus weighing at least 75,000 pounds.
ITEM NO.: 7. CON'T Z-9265
Building Codes:
Project is subject to full commercial plan review and approval prior to issuance of a building
permit. For information on submittal requirements and the review process, contact a commercial
plans examiner:
Curtis Richey at 501.371.4724; crichey@littlerock.gov or
Mark Alderfer at 501.371.4875; malderfer@littlerock.gov .
County Planning: No comment.
Rock Region METRO: Location would be served by Route 3 Baptist Medical Center along Kanis Road.
We have no objections to proposed improvements.
Planning Division: No comment.
Landscape:
Site plan must comply with the City's minimal landscape and buffer ordinance requirements.
A perimeter planting strip is required along any side of a vehicular use area that abuts adjoining
property or the right-of-way of any street. This strip shall be at least nine (9) feet wide. One (1)
tree and three (3) shrubs or vines shall be planted for every thirty (30) linear feet of perimeter
planting strip. Perimeter planting strips are partially deficient on the south and west sides of the
property. Perimeter planting strips are deficient. SHOWN ON DRAWING
Screening requirements will need to be met for the vehicular use areas adjacent to street right-of-
ways. Provide screening shrubs with an average linear spacing of not less at three (3) feet within
the required landscape area. Provide trees with an average linear spacing of not less than thirty
(30) feet. TO BE SHOWN ON LANDSCAPING PLAN BY REGISTERED LANDSCAPE
ARCHITECT
Eight percent (8%) of the vehicular use area must be designated for green space; this green space
needs to be evenly distributed throughout the parking area(s). The minimum size of an interior
landscape area shall be one hundred fifty (150) square feet for developments with one hundred
fifty (150) or fewer parking spaces. Interior islands must be a minimum of seven and one half (7
1 /2) feet in width. Trees shall be included in the interior landscape areas at the rate of one (1) tree
for every twelve (12) parking spaces. SHOWN ON PLAN
Landscape areas shall be provided between the vehicular use area used for public parking and the
general vicinity of the building, excluding truck loading or service areas not open to public
parking. These shall be provided at the rate equivalent to planter strip three (3) feet wide along the
vehicular use area. One (1) tree and four (4) shrubs shall be planted in the building landscape areas
for each forty (40) linear feet of vehicular use area abutting the building. Landscape areas will
need to be added for the commercial building. TO BE SHOWN ON LANDSCAPING PLAN BY
REGISTERED LANDSCAPE ARCHITECT
An automatic irrigation system to water landscaped areas shall be required for developments of
one (1) acre or larger. TO BE SHOWN ON LANDSCAPING PLAN BY REGISTERED
LANDSCAPE ARCHITECT
The development of two (2) acres or more requires the landscape plan to be stamped with
the seal of a Registered Landscape Architect. NOTED
ITEM NO.: 7. CON'T Z-9265
The City Beautiful Commission recommends preserving as many existing trees as feasible on this
site. Credit toward fulfilling Landscape Ordinance requirements can be given when preserving
trees of six (6) inch caliper or larger.
Other: Submit responses to staff issues and four (4) copies of a revised site plan (if required) no later than
Wednesday, October 11, 2017. Required notices are to be sent via certified mail to all owners of
properties located within two hundred (200) feet of the site no later than Wednesday October 11, 2017.
The City provided notices form must be used. Proof of notices is to be provided to staff no later than
October 20, 2017.